• Title/Summary/Keyword: High Radio-Frequency

Search Result 832, Processing Time 0.041 seconds

The Early Results of Endovenous Radiofrequency Ablation Using the 7 Fr. VNUS $ClosureFAST^{(R)}$ System in Varicose Veins (혈관 내 고주파열치료법인 7 Fr. VNUS $ClosureFAST^{(R)}$ System을 이용한 하지 정맥류 치료의 조기 결과)

  • Ryu, Sang-Woo;Oh, Hye-Ryung;Kim, Mi-Kyung;Moon, Seung-Ho;CheKar, Jay-Key;Yun, Ju-Sik;Hong, Seong-Beom
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.238-243
    • /
    • 2009
  • Background: Radiofrequency obliteration and endovenous laser therapy of the greater saphenous vein have recently been introduced as alternative, minimally invasive techniques for the treatment of saphenous vein incompetence. The 7 Fr. VNUS $ClosureFAST^{(R)}$ radiofrequency obliteration system was introduced in Gwang-Ju Veterans hospital. The purpose of this study is to evaluate the efficacy and complications of radiofrequency obliteration using the 7 Fr. VNUS $ClosureFAST^{(R)}$ system. Material and Method: Between May 2, 2007 and May 31, 2008, we performed radiofrequency obliteration on 90 patients. The number of males was 67 and their mean age was $57.9{\pm}11.0$ (range: $23{\sim}78$) years old. The patients underwent follow up exams at 3 weeks after the procedures and then every 3 months. The effects of treatment and the complications were reviewed. Result: The postoperative complications were ecchymosis (94.4%), pain (27.8%), paresthesia (25.6%), bullous formation (8.9%), edema (6.7%) and phlebitis (2.2%). One patient showed good blood flow after 3 weeks and one patient showed good blood flow after 3 months. The one-year success rate of radiofrequency obliteration in varicose veins was 97.6%. Conclusion: Our data showed acceptable operative results and short-term clinical results for treating varicose veins with radio frequency obliteration. Long-term follow-up and comparison of radio frequency obliteration with high ligation and stripping, previous radiofrequency ablation and endovenous laser therapy are needed in the future.

Development of $^1H-^{31}P$ Animal RF Coil for pH Measurement Using a Clinical MR Scanner (임상용 MR에서 pH 측정을 위한 동물 실험용 $^1H-^{31}P$ RF 코일 개발)

  • Kim, Eun Ju;Kim, Daehong;Lee, Sangwoo;Heo, Dan;Lee, Young Han;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2014
  • Purpose : To establish a pH measurement system for a mouse tumor study using a clinical scanner, to develop the $^1H$ and 31P radio frequency (RF) coil system and to test pH accuracy with phantoms. Materials and Methods: The $^1H$ and the $^{31}P$ surface coils were designed to acquire signals from mouse tumors. Two coils were positioned orthogonally for geometric decoupling. The pH values of various pH phantoms were calculated using the $^1H$ decoupled $^{31}P$ MR spectrum with the Henderson-Hasselbalch equation. The calculated pH value was compared to that of a pH meter. Results: The mutual coil coupling was shown in a standard $S_{12}$. Coil coupling ($S_{12}$) were -73.0 and -62.3 dB respectively. The signal-to-noise ratio (SNR) obtained from the homogeneous phantom $^1H$ image was greater than 300. The high resolution in vivo mice images were acquired using a $^{31}P$-decoupled $^1H$ coil. The pH values calculated from the $^1H$-decoupled $^{31}P$ spectrum correlated well with the values measured by pH meter ($R^2$=0.97). Conclusion: Accurate pH values can be acquired using a $^1H$-decoupled $^{31}P$ RF coil with a clinical scanner. This two-surface coil system could be applied to other nuclear MRS or MRI.

Magnetoresistance of Bi Nanowires Grown by On-Film Formation of Nanowires for In-situ Self-assembled Interconnection

  • Ham, Jin-Hee;Kang, Joo-Hoon;Noh, Jin-Seo;Lee, Woo-Young
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2010.06a
    • /
    • pp.79-79
    • /
    • 2010
  • Semimetallic bismuth (Bi) has been extensively investigated over the last decade since it exhibits very intriguing transport properties due to their highly anisotropic Fermi surface, low carrier concentration, long carrier mean free path l, and small effective carrier mass $m^*$. In particular, the great interest in Bi nanowires lies in the development of nanowire fabrication methods and the opportunity for exploring novel low-dimensional phenomena as well as practical application such as thermoelectricity[1]. In this work, we introduce a self-assembled interconnection of nanostructures produced by an on-film formation of nanowires (OFF-ON) method in order to form a highly ohmic Bi nanobridge. A Bi thin film was first deposited on a thermally oxidized Si (100) substrate at a rate of $40\;{\AA}/s$ by radio frequency (RF) sputtering at 300 K. The sputter system was kept in an ultra high vacuum (UHV) of $10^{-6}$ Torr before deposition, and sputtering was performed under an Ar gas pressure of 2m Torr for 180s. For the lateral growth of Bi nanowires, we sputtered a thin Cr (or $SiO_2$) layer on top of the Bi film. The Bi thin films were subsequently put into a custom-made vacuum furnace for thermal annealing to grow Bi nanowires by the OFF-ON method. After thermal annealing, the Bi nanowires cannot be pushed out from the topside of the Bi films due to the Cr (or $SiO_2$) layer. Instead, Bi nanowires grow laterally as a mean s of releasing the compressive stress. We fabricated a self-assembled Bi nanobridge (d=192 nm) device in-situ using OFF-ON through annealing at $250^{\circ}C$ for 10hours. From I-V measurements taken on the Bi nanobridge device, contacts to the nanobridge were found highly ohmic. The quality of the Bi nanobridge was also proved by the high MR of 123% obtained from transverse MR measurements. These results manifest the possibility of self-assembled nanowire interconnection between various nanostructures for a variety of applications and provide a simple device fabrication method to investigate transport properties on nanowires without complex patterning and etching processes.

  • PDF

Artifactual Perfusion Defects due to the Parameters of Reconstruction Filter in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT 영상에서 재구성 필터에 의한 인위적 관류결손에 관한 연구)

  • Kwark, Cheol-Eun;Lee, Kyung-Han;Lee, Dong-Soo;Park, Yong-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • Tc-99m-MIBI(Sestamibi) myocardial SPECT along with T1-201 tomographic imaging has demonstrated wide application and high image qualify sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow, The qualitative values of myocardial SPECT with Tc-99m-MIBI as well as the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection(FBP) is the common standard for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it Is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected filter parameters such as cutoff frequencies and order(Butterworth case). The cutoff frequencies basically remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable thresh-old of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Nyquist frequency would reveal severe degradation of radio-active distribution near inferior and/or Inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

An Analysis on the Characteristics of Work Items for RFID Technology Application Possibility Valuation (RFID 기술적용 가능성 평가를 위한 각 공종별 주요자재 특성분석)

  • Koo, Do-Hyung;Yoon, Su-Won;Chin, Sang-Yoon;Kim, Yea-Sang;Kwon, Soon-Wook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.2
    • /
    • pp.159-169
    • /
    • 2008
  • Recently, domestic construction projects Have become more high-rised, bigger, sophisticated, so necessity of logistics and progress management through application of various management theories has also been increased and development of IT technologies like RFID can help to improve management method, although the existing logistics and progress management studies are applied only to single progress or important material. It is a basic research for integrated framework for logistics and progress management. An analysis on the characteristics of RFID tech was performed for major materials or components of each work item in office building projects. This paper will make foundation of integrated framework for logistics and progress management in construction project, utilizing RFID technology by analysing materials type like materials which can be chased and measured, materials which can be chased and measured by certain methodologies, materials which can be chased and measured by future technologies, materials which are difficult to be chased and measured. So we can effectively control logistics and progress management, appling the optimum RFID technology to each construction project, and we need to study out solution in order to overcome RFID technology limitation through development of specification counterproposal about delicate materials of the RFID technology application.

60 GHz Band Non-Radiative Dielectric Waveguide Mixer having the Waveguide Directional Coupler (도파관 방향성 결합기를 갖는 60 GHz 대역 Non-Radiative Dielectric 도파관 혼합기)

  • Yoo, Young-Geun;Choi, Jae-Ha
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.4
    • /
    • pp.397-403
    • /
    • 2008
  • In this paper, the mixer was implemented in the non-radiative dielectric waveguide that is the main component of 60 GHz band radio telecommunications equipment which a demand increases for the purpose of point-to-point communication network. As to the manufacture of the non-radiative dielectric waveguide mixer, it was the implementation of the dielectric line combiner to be most difficult. The thing which that gives shape to the curvature which is the dielectric line determined and the to place in the exact interval thing are easy. For this reason, it was very difficult to make in order to have the regular performance in the case of the mixer having the dielectric line combiner. In this paper, since the dielectric line combiner was replaced with the waveguide directional coupler and the manufacture was possible through a processing it had the characteristic that a combiner is fixed. In result, the productivity of a mixer was innovatively improved. The design frequency of the mixer implemented through this paper RF and LO are $51{\sim}64\;GHz$. IF Is $DC{\sim}\;GHz2$. The down conversion loss toward the RF input of $60{\sim}62\;GHz$ was measured by $10{\pm}1\;dB$ in the condition that LO is 10 dBm, 60 GHz.

Use of Unmanned Aerial Vehicle for Multi-temporal Monitoring of Soybean Vegetation Fraction

  • Yun, Hee Sup;Park, Soo Hyun;Kim, Hak-Jin;Lee, Wonsuk Daniel;Lee, Kyung Do;Hong, Suk Young;Jung, Gun Ho
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.126-137
    • /
    • 2016
  • Purpose: The overall objective of this study was to evaluate the vegetation fraction of soybeans, grown under different cropping conditions using an unmanned aerial vehicle (UAV) equipped with a red, green, and blue (RGB) camera. Methods: Test plots were prepared based on different cropping treatments, i.e., soybean single-cropping, with and without herbicide application and soybean and barley-cover cropping, with and without herbicide application. The UAV flights were manually controlled using a remote flight controller on the ground, with 2.4 GHz radio frequency communication. For image pre-processing, the acquired images were pre-treated and georeferenced using a fisheye distortion removal function, and ground control points were collected using Google Maps. Tarpaulin panels of different colors were used to calibrate the multi-temporal images by converting the RGB digital number values into the RGB reflectance spectrum, utilizing a linear regression method. Excess Green (ExG) vegetation indices for each of the test plots were compared with the M-statistic method in order to quantitatively evaluate the greenness of soybean fields under different cropping systems. Results: The reflectance calibration methods used in the study showed high coefficients of determination, ranging from 0.8 to 0.9, indicating the feasibility of a linear regression fitting method for monitoring multi-temporal RGB images of soybean fields. As expected, the ExG vegetation indices changed according to different soybean growth stages, showing clear differences among the test plots with different cropping treatments in the early season of < 60 days after sowing (DAS). With the M-statistic method, the test plots under different treatments could be discriminated in the early seasons of <41 DAS, showing a value of M > 1. Conclusion: Therefore, multi-temporal images obtained with an UAV and a RGB camera could be applied for quantifying overall vegetation fractions and crop growth status, and this information could contribute to determine proper treatments for the vegetation fraction.

A Study on the Use of Supplementary Teaching Materials and Implements in the High School Home Economics Education (고등학교 가정과 교육에서 보조학습 교재.교구의 활용실태 연구)

  • 조은경;김용숙
    • Journal of Korean Home Economics Education Association
    • /
    • v.9 no.1
    • /
    • pp.1-17
    • /
    • 1997
  • This study was conducted to obtain basic materials to improve the teaching method of Home Economics by theoretically looking into the supplementary teaching materials or implements usable in teaching Costume History area. And based on these data, the types and the applications of the supplementary teaching materials or implements highschool owned were examined. The subjects of this study were 111 Home Economics and Housework curriculum highschool teachers who give a lecture in the country by using self-administered questionnaires. SAS program was used to calculate frequency, percentage, average, standard deviation, and $\chi$(sup)2-test analysis. The results of the study were as follows; 1. Most of the highschool teachers used the school expenses for experiments in preparing the supplementary teaching materials or implements. 2. Of the supplementary teaching materials and implements concerning Costume History, visual implements such as slides and pictures were the mostly owned. CD and audio implements as cassette-tapes were not used. 3. Most of the teachers recognized the importance of the audio-visual teaching materials and implements concerning Costume History. 4. Among the audio-visual materials and implements concerning Costume History by which can be made by school teachers of Home Economics and Housework curriculum, the mostly used one was ‘cutting pictorials from magazines and newspapers’, and the next were ‘orbital materials’, and ‘copy the pictorials’, and the least was ‘recording from the radio’. 5. Most of the annual expenses assigned to the department of Home Economics was used in cooking practice, and the least of the expenses was assigned in buying audio-visual teaching materials and implements. 6. Time assigned to the area of Home Economics was for the most part one or two hours per week, and among this, time assigned to the history of western costume and the history ok korean costume was for the most part five to eight hours. 7. The areas that the highschool teachers felt difficulties mostly during clothing and textiles curriculum were ‘textiles’and the next were ‘knitting’, ‘western costume history’, and ‘korean clothing construction’. 8. The difficulties the highschool teachers faced while teaching Costume History were mostly that ‘the pictorials in the text is not fully explainable’, the next were ‘most of the supplementary teaching materials or implements are not owned’, ‘have to explain very much in a short time’, and ‘the lectural explanation is insufficient’. 9. The solution for the difficulties that the highschool teachers faced while teaching Costume History was mostly ‘the information, on which audio-visual materials and implements are distributed in the market, should be easy to obtain’, the next opinions were ‘the school should provide enough experiment and practice expenses to buy audio-visual materials and implements’, and ‘education facilities of the Home Economics Department should be the main aspects in improving the teaching methods and should give special lectures about it’.

  • PDF

Control of electrical types in the P-doped ZnO thin film by Ar/$O_2$ gas flow ratio

  • Kim, Young-Yi;Han, Won-Suk;Kong, Bo-Hyun;Cho, Hyung-Koun;Kim, Jun-Ho;Lee, Ho-Seoung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.11-11
    • /
    • 2008
  • ZnO has a very large exciton binding energy (60 meV) as well as thermal and chemical stability, which are expected to allow efficient excitonic emission, even at room temperature. ZnO based electronic devices have attracted increasing interest as the backplanes for applications in the next-generation displays, such as active-matrix liquid crystal displays (AMLCDs) and active-matrix organic light emitting diodes (AMOLEDs), and in solid state lighting systems as a substitution for GaN based light emitting diodes (LEDs). Most of these electronic devices employ the electrical behavior of n-type semiconducting active oxides due to the difficulty in obtaining a p-type film with long-term stability and high performance. p-type ZnO films can be produced by substituting group V elements (N, P, and As) for the O sites or group I elements (Li, Na, and K) for Zn sites. However, the achievement of p-type ZnO is a difficult task due to self-compensation induced from intrinsic donor defects, such as O vacancies (Vo) and Zn interstitials ($Zn_i$), or an unintentional extrinsic donor such as H. Phosphorus (P) doped ZnO thin films were grown on c-sapphire substrates by radio frequency magnetron sputtering with various Ar/ $O_2$ gas ratios. Control of the electrical types in the P-doped ZnO films was achieved by varying the gas ratio with out post-annealing. The P-doped ZnO films grown at a Ar/ $O_2$ ratio of 3/1 showed p-type conductivity with a hole concentration and hole mobility of $10^{-17}cm^{-3}$ and $2.5cm^2/V{\cdot}s$, respectively. X-ray diffraction showed that the ZnO (0002) peak shifted to lower angle due to the positioning of $p^{3-}$ ions with a smaller ionic radius in the $O^{2-}$ sites. This indicates that a p-type mechanism was due to the substitutional Po. The low-temperature photoluminescence of the p-type ZnO films showed p-type related neutral acceptor-bound exciton emission. The p-ZnO/n-Si heterojunction LEO showed typical rectification behavior, which confirmed the p-type characteristics of the ZnO films in the as-deposited status, despite the deep-level related electroluminescence emission.

  • PDF

Design and Implementation of 5G mmWave LTE-TDD HD Video Streaming System for USRP RIO SDR (USRP RIO SDR을 이용한 5G 밀리미터파 LTE-TDD HD 비디오 스트리밍 시스템 설계 및 구현)

  • Gwag, Gyoung-Hun;Shin, Bong-Deug;Park, Dong-Wook;Eo, Yun-Seong;Oh, Hyuk-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.5
    • /
    • pp.445-453
    • /
    • 2016
  • This paper presents the implementation and design of the 1T-1R wireless HD video streaming systems over 28 GHz mmWave frequency using 3GPP LTE-TDD standard on NI USRP RIO SDR platform. The baseband of the system uses USRP RIO that are stored in Xilinx Kintex-7 chip to implement LTE-TDD transceiver modem, the signal that are transceived from USRP RIO up or down converts to 28 GHz by using self-designed 28 GHz RF transceiver modules and it is finally communicated HD video data through self-designed $4{\times}8$ sub array antennas. It is that communication method between USRP RIO and Host PC use PCI express ${\times}4$ to minimize delay of data to transmit and receive. The implemented system show high error vector magnitude performance above 25.85 dBc and to transceive HD video in experiment environment anywhere.