• Title/Summary/Keyword: High Power Rating

Search Result 166, Processing Time 0.032 seconds

A Study on Earth Pressure Calculating Method about Shield TBM Tunnel Segments in the Rock (암반층에서 쉴드 TBM 터널 세그먼트의 작용하중 산정방법에 관한 연구)

  • Chun, Byungsik;Ki, Jungsu;Kang, Taehee;Kwag, Yunehyeong;Byun, Yoseph
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.5
    • /
    • pp.13-21
    • /
    • 2014
  • This study analyzed the differences in the analysis techniques through a comparative analysis of the various segment's modeling techniques of Shield TBM method and proposed reasonable modeling techniques. Also, this study suggested reasonable estimating methods of load to be applicable in the field through the load analysis and three-dimensional finite element analysis by estimating model of rock mass relaxation load. Estimating method of relaxation area by rock mass rating makes no odds of output in subgrade with high rock mass rating, but so the difference of output is large, that is judged to set conservative design off. In estimating result of rock mass relaxation area by three-dimensional analysis relaxation area of subgrade with low-grade soil was predicted to be positioned at medium-range of many methods, in case of designing segment in subgrade with low-grade soil it needs to actively review estimation of relaxation area through three-dimensional analysis reflecting mechanical tunnel excavation.

Prototype Development of 3-Phase 3.3kV/220V 6kVA Modular Semiconductor Transformer (3상 3.3kV/220V 6kVA 모듈형 반도체 변압기의 프로토타입 개발)

  • Kim, Jae-Hyuk;Kim, Do-Hyun;Lee, Byung-Kwon;Han, Byung-Moon;Lee, Jun-Young;Choi, Nam-Sup
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1678-1687
    • /
    • 2013
  • This paper describes a prototype of 3-phase 3.3kV/220V 6kVA modular semiconductor transformer developed in the lab for feasibility study. The developed prototype is composed of three single-phase units coupled in Y-connection. Each single-phase unit with a rating of 1.9kV/127V 2kVA consists of a high-voltage high-frequency resonant AC-DC converter, a low-voltage hybrid-switching DC-DC converter, and a low-voltage hybrid-switching DC-AC converter. Also each single-phase unit has two DSP controllers to control converter operation and to acquire monitoring data. Monitoring system was developed based on LabView by using CAN communication link between the DSP controller and PC. Through various experimental analyses it was verified that the prototype operates with proper performance under normal and sag condition. The system efficiency can be improved by adopting optimal design and replacing the IGBT switch with the SiC MOSFET switch. The developed prototype confirms a possibility to build a commercial high-voltage high-power semiconductor transformer by increasing the number of series-connected converter modules in high-voltage side and improving the performance of switching element.

3-Phase Power Quality Disturbance Generator with Phase Jump Function (위상급변 기능을 갖는 3상 전력품질 외란발생기)

  • Lee, B.C.;Choi, S.H.;Paeng, S.H.;Park, S.D.;Choi, N.S.;Kim, I.D.;Chun, T.W.;Kim, H.G.;Nho, E.C.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.463-470
    • /
    • 2006
  • This paper deals with a new 3-phase power quality disturbance generator. The proposed generator can provide phase jump as well as voltage sag, swell, outage, unbalance, and over and under voltage. The operating principle of the generator is described in each mode of disturbance. The magnitude of the phase jump is analysed and it is found that the magnitude is the function of the turn-ratios of the transformers consisting the generator. The scheme has simple structure compared with the conventional one, and the major components of the proposed scheme are SCR thyristor and transformer, which guarantees high reliability and cost-effective implementation of the generator. Furthermore, high efficiency can be obtained because there is no PWM switching of the semiconductor devices, and it is easy to control the system. Simulations are carried out to confirm the operation in each disturbance mode, and experiments has been done with 5kVA power rating. The usefulness of the proposed scheme is verified through simulation and experimental results. It is expected that the scheme can be applied to the performance test of the custom power devices such as UPS, DVR, DSTATCOM, and SSTS with cost-effective system.

The Development of Buck Type Electronic Ballast for 250W MHL and Dimming System (250W MHL용 Buck Type 전자식 안정기 및 Dimming 시스템 개발)

  • 박종연;박영길;정동열;김한수
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.30-40
    • /
    • 2002
  • This paper studies the electronic ballast development for 250w MH lamps. We have improved the input power factor using a PFC IC. To provide the rating voltage required In the lamps, we have used the buck type dc-dc converter By this method, the stress of switching devices in inverter can be reduced. The inverter is the Full-Bridge type. To eliminate the acoustic resonance phenomena of MH lamps, we have added the high frequency sinewave voltage to the low frequency square-wave voltage to the lamp. We hove developed the igniter circuit using the L, C devices. We could control dimming of the lamp by varying the output voltage of the buck converter. The time of illuminating lamps and luminous intensity could be adjusted by season and time band. The buck converter output voltage can be controlled and the no load and over current situation were Protected by the development of the microprocessor Program.

District-Level Seismic Vulnerability Rating and Risk Level Based-Density Analysis of Buildings through Comparative Analysis of Machine Learning and Statistical Analysis Techniques in Seoul (머신러닝과 통계분석 기법의 비교분석을 통한 건물에 대한 서울시 구별 지진취약도 등급화 및 위험건물 밀도분석)

  • Sang-Bin Kim;Seong H. Kim;Dae-Hyeon Kim
    • Journal of Industrial Convergence
    • /
    • v.21 no.7
    • /
    • pp.29-39
    • /
    • 2023
  • In the recent period, there have been numerous earthquakes both domestically and internationally, and buildings in South Korea are particularly vulnerable to seismic design and earthquake damage. Therefore, the objective of this study is to discover an effective method for assessing the seismic vulnerability of buildings and conducting a density analysis of high-risk structures. The aim is to model this approach and validate it using data from pilot area(Seoul). To achieve this, two modeling techniques were employed, of which the predictive accuracy of the statistical analysis technique was 87%. Among the machine learning techniques, Random Forest Model exhibited the highest predictive accuracy, and the accuracy of the model on the Test Set was determined to be 97.1%. As a result of the analysis, the district rating revealed that Gwangjin-gu and Songpa-gu were relatively at higher risk, and the density analysis of at-risk buildings predicted that Seocho-gu, Gwanak-gu, and Gangseo-gu were relatively at higher risk. Finally, the result of the statistical analysis technique was predicted as more dangerous than those of the machine learning technique. However, considering that about 18.9% of the buildings in Seoul are designed to withstand the Seismic intensity of 6.5 (MMI), which is the standard for seismic-resistant design in South Korea, the result of the machine learning technique was predicted to be more accurate. The current research is limited in that it only considers buildings without taking into account factors such as population density, police stations, and fire stations. Considering these limitations in future studies would lead to more comprehensive and valuable research.

Effect the I-T curve and electrical characteristic of fuse elements by plated tin thickness (주석 도금 두께에 따른 퓨즈 가용체의 I-T 커브 및 전기적 특성의 영향)

  • Jin, Sang-Jun;Kim, Eun-Min;Youn, Jae-Seo;Lee, Ye-Ji;Noh, Seong-Yeo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.80-87
    • /
    • 2018
  • In recent years, due to the spread of various renewable energy power sources and the pursuit of high efficiency and low-power consumption, not only trends in the electric power industry but also the consumption, control methods, and characteristics are diversified. However, in this diversified electric power industry, the fuse (which is the core part responsible for safety) has not developed significantly in classical operation mode, and thus, fires continue to occur. In this paper, the effects of low melting-point metal plating and high melting-point metal plating on operating characteristics and IT curve movement of the fuse are investigated in a cartridge fuse, which is a classic fuse manufacturing method. The effects of plating on the thickness of the fuse are investigated, and various operating characteristics of the fuse are implemented. In addition, it is suggested that the plating of the low melting-point metal moves the rated current line of the fuse to a low rating, and moves operating characteristics to characteristics of delay operation. It is possible to design various operating characteristics using this characteristic.

Comparing Quantitative EEG and Low Resolution Electromagnetic Tomography Imaging between Deficit Syndrome and Non-Deficit Syndrome of Schizophrenia (정신분열병의 결핍증후군과 비결핍증후군에서 QEEG와 sLORETA를 이용한 비교연구)

  • Lee, Sang-Eun;Yim, Seon-Jin;Lee, Mi-Gyung;Lee, Jae-Won;Han, Kyu-Hee;Lee, Jong-Il;Sim, Min-Young;Yoon, Hai-Joo;Shin, Byoung-Hak
    • Sleep Medicine and Psychophysiology
    • /
    • v.17 no.2
    • /
    • pp.91-99
    • /
    • 2010
  • Objectives: Deficit schizophrenia (DS) constitutes a disease separate from non-deficit schizophrenia (NDS). The aim of the current study was to compare the quantitative EEG and low resolution electromagnetic tomography (LORETA) imaging between DS and NDS. Methods: This study was performed by 32 channels EEG for 42 schizophrenia patients who we categorized into DS and NDS using proxy instrument deficit syndrome (PDS). We performed the absolute power spectral analyses for delta, theta, alpha, low beta and high beta activities. We compared power spectrum between two groups using Independent t-test. Partial correlation test was performed with clinical parameters. Standardized LORETA (sLORETA) was used for comparison of cortical activity, and statistical nonparametric mapping (SnPM) was applied for the statistical analysis. Results: DS showed significantly increased delta and theta absolute power in fontal and parietal region compared with NDS (p<0.05). Power spectrum showed significant correlation with 'anergia' and 'hostility/suspiciousness' subscale of brief psychiatric rating scale (BPRS)(p<0.05). sLORETA found out the source region (anterior cingulate cortex/limbic part) that delta activity was significantly increased in DS (p=0.042). Conclusions: DS showed different cortical activity compared with NDS. Our results may suggest QEEG and LORETA could be the marker in differentiating between DS and NDS.

  • PDF

An Innovative Solution for the Power Quality Problems in Induction Motor by Using Silica and Alumina Nano Fillers Mixed Enamel for the Coatings of the Windings

  • Mohanadasse, K.;Sharmeela, C.;Selvaraj, D. Edison
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1621-1625
    • /
    • 2015
  • Power quality has always been a concern of power engineers. Certainly an argument can be successfully made that most parts of power engineering have the ultimate objective to improve power quality. AC motors were widely used in industrial and domestic applications. Generally, AC motors were of two types: Induction and Synchronous motors. In motor many parameters like different load cycling, switching, working in hot weather and unbalances creates harmonics which creates major reasons for temperature rise of the motors. Due to high peak value of voltage, harmonics can weaken insulation in cables, windings and capacitors and different electronic components. Higher value of harmonics increase the motor current and decrease the power factor which will reduce the life time of the motor and increase the overall rating of all electrical equipments. Harmonics reduction of all the motors in India will save more power. Coating of windings of the motor with nano fillers will reduce the amount of harmonics in the motor. Based on the previous project works, actions were taken to use the enamel filled with various nano fillers for the coating of the windings of the different AC motors. Ball mill method was used to convert the micro particles of Al2O3, SiO2, TiO2, ZrO2 and ZnO into nano particles. SEM, TEM and XRD were used to augment the particle size of the powder. The synthesized nano powders were mixed with the enamel by using ultrasonic vibrator. Then the enamel mixed with the nano fillers was coated to the windings of the several AC motors. Harmonics were measured in terms of various indices like THD, VHD, CHD and DIN by using Harmonic analyzer. There are many other measures and indices to describe power quality, but none is applicable in all cases and in many instances, these indices may hide more than they show. Sometimes power quality indices were used as a basis of comparison and standardization. The efficiency of the motors was increased by 5 – 10 %. The thermal withstanding capacity of the motor was increased by 5º to 15º C. The harmonics of the motors were reduced by 10 – 50%.

A Study of Voltage Balancing Method in Series-Connected EDLCs for High Power Applications (다중 직렬 연결된 대용량 EDLC 모듈에 적합한 전압 밸런싱 기법에 대한 연구)

  • Cha, Dae-Joong;Baek, Ji-Eun;Ko, Kwang-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.22-27
    • /
    • 2015
  • In this paper, the problem of voltage unbalancing in series-connected multiple electric double-layer capacitors(EDLCs) is studied. Good understanding of this problem is required in order to increase reliability and stability of an energy storage system comprising EDLCs. Existing methods to settle voltage unbalancing cannot mitigate the problem enough for each cell, since most method have been applied to each module. For equalizing between cells, Zener diode which is one of passive method have been well examined in literature. However, Zener have well not used in balancing due to heating problem. In addition, It is difficult to choose Zener diode fitted rating voltage of EDLC, because of its internal resistance. Thus, we proposed passive balancing using Zener diode by analyzing parasitic element of Zener and EDLC. To experimentally confirm the balancing effect, we compared in two occasions which are with and without passive. As a result, proposed passive balancing circuit mitigated unbalanced voltage gap between EDLCs.

Development of 500W Inverter with Pure Sine Wave Output (500W급 순수사인파 인버터 설계)

  • Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.61-68
    • /
    • 2018
  • This paper is elaborates on the pure sine wave single phase inverter of 500W level which is driven by battery. The inverter is structured to raise the battery voltage to 400V by using the push-pull topology, and by using H-bridge with the high voltage, it outputs common 220VAC. This topology is utilized to use the power semiconductor device in order to design and manufacture the inverter of 500W at input voltage rating of 12VDC. As a result, the efficiency exceeds 90% in partial sections, but on average, the efficiency is approximately 89.5%, and as for output voltage, frequency fluctuation range and THD, the result can be less than ${\pm}5%$.