A Study on Vision System Design for Automatic Inspection of Steam Generator in Nuclear Power Plants (원전 스팀 제너레이터 세관 자동검사용 비젼시스템 설계에 관한 연구)

  • 한성현;서운학;천영신;이만형
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.5
    • /
    • pp.658-665
    • /
    • 1998
  • In this paper, we propose a new approach to the development of the automatic vision system to examine and repair the steam generator tubes at remote distance. In nuclear power plants, workers are reluctant of works in steam generator because of the high radiation environment and limited working space. It is strongly recommended that the examination and maintenance works be done by an automatic system for the protection of the operator from the radiation exposure. Digital signal processors are used in implementing real time recognition and examination of steam generator tubes in the proposed vision system. Performance of the proposed digital vision system is illustrated by simulation and experiment for similar steam generator model.

  • PDF

Development of Automatic Inspection and Maintenance Technology for Steam Generator in Nuclear Power Plants (원자력 발전소 증기세관 자동검사 및 보수 기술개발)

  • Seo, W.H.;Jung, D.Y.;Lee, J.W.;Han, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.542-547
    • /
    • 2000
  • In this paper, we propose a new approach to the development of the automatic vision system to examine and repair the steam generator tubes at remote distance. In nuclear power plants, workers are reluctant of works in steam generator because of the high radiation environment and limited working space. It is strongly recommended that the examination and maintenance works be done by an automatic system for the protection of the operator from the radiation exposure. Digital signal processors are used in implementing real time recognition and examination of steam generator tubes in the proposed vision system. Performance of proposed digital vision system is illustrated by simulation and experiment for similar steam generator model.

  • PDF

A Study on Vision System Design for Automatic Inspection of Steam Generator in Nuclear Power Plants (원전 스팀제너레이터 세관 자동검사용 로봇 비젼시스템 설계에 관한 연구)

  • 서운학
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.571-578
    • /
    • 1999
  • In this paper, we propose a new approach to the development of the automatic vision system to examine and repair the steam generator tubes at remote distance. In nuclear power plants, workers are reluctant of works in steam generator because of the high radiation environment and limited working space. It is strongly recommended that the examination and maintenance works be done by an automatic system for the protection of the operator from the radiation exposure. Digital signal processors are used in implementing real time recognition and examination of steam generator tubes in the proposed vision system. Performance of proposed digital vision system is illustrated by simulation and experiment for similar steam generator model.

  • PDF

Vision System Design for Automatic Test and Repair of Steam Generator Holes in Nuclear Power Plants (원자력발전소 증기 발생기의 자동검사 및 수리를 위한 비젼시스템 설계)

  • 한성현
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.6
    • /
    • pp.5-14
    • /
    • 1998
  • In this paper we propose a new approach to the development of the automatic vision system to examine and repair the steam generator tubes at remote distance. In nuclear power plants, workers are reluctant of works in steam generator because of the high radiation environment and limited working space. It is strongly recommended that the examination and maintenance works be done by an automatic system for the protection of the operator from the radiation exposure. Digital signal processors are used in implementing real time recognition and examination of steam generator tubes in the proposed vision system. Performance of proposed digital vision system is illustrated by simulation and experiment for similar steam generator model.

  • PDF

A Design and Voltage Control of a High Efficiency Generator with PM Exciter (고효율 영구자석 여자기 구조의 발전기 설계와 전압제어)

  • Jo, YeongJun;Lee, Dong-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1827-1834
    • /
    • 2016
  • This paper presents a high efficient generator with PM(Permanent Magnet) exciter. The proposed PM exciter for the generator can produce a linear output voltage according to the engine speed. This output voltage is directly used to control the field current of the generator to adjust the generator output voltage. In the proposed generator system, since the field winding current can be supplied by the PM exciter, the generator can self-start without any battery or an external power supply due to the low residential flux. Furthermore, the operating efficiency of the generator is higher than a conventional winding exciter. The main problem of the proposed generator system, the field winding current controller has to be embedded inside the generator, and it rotates according to the generator shaft. In this paper, the proper embedded current controller is designed for the proposed generator system. Due to the embedded controller cannot be connected to the outside the generator controller, the measured instantaneous output voltage of the generator is transferred by the photo isolated communication using shaft aligned infrared transmitter and receiver to keep the constant generator output voltage. In this paper, 10kW, 380V engine generator with PM exciter and the embedded DAVR(Digital Automatic Voltage Regulator) are described. The proposed high efficiency generator is simulated and tested to verify the effectiveness.

Study on Optimization of Throttle Margin in High Pressure Turbine of Nuclear Power Plant (원자력 발전소 고압터빈의 교축여유(Throttle Margin) 최적화 연구)

  • Ko, W.S.
    • Journal of Power System Engineering
    • /
    • v.14 no.4
    • /
    • pp.43-49
    • /
    • 2010
  • In the present study, optimization of throttle margin for high pressure turbine to be retrofitted or partially modified for power uprating or life extension in nuclear power plant, has been performed to increase the electrical output. Throttle margin for high pressure turbine is required to maintain all the time the rated power by opening more of governor valves whenever inlet pressure is decreased due to the tube plugging of steam generator. If throttle margin of high pressure turbine is too much compared to remaining lifetime, loss of electrical output due to pressure drop of governor valves is inevitable. On the contrary, if it is too little, the rated power operation can not be accomplished when inlet pressure of high pressure turbine is dropped after many years operation. So, throttle margin for high pressure turbine in nuclear power plant is compromised considering for the degradation of steam generator, governor valve capacity, manufacturing tolerance of high pressure turbine, future plan of power uprating, and remaining lifetime of power plant.

Development of 30kW MF Generator for NF3 60 liter high capacity Remote Plasma Source (NF3 60 Liter급 대용량 Remote Plasma Source용 30kW MF Generator 개발)

  • Kim, Dae-Wook;Lim, Eun-Suk;Lee, Jong-Sik;Choi, Dae-Kyu;Choi, Sang-Don
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.51-52
    • /
    • 2013
  • 본 논문에서는 박막형 태양전지 및 LCD 제조공정에서 증착 공정 후 챔버 내부에 쌓이는 Si(실리콘)을 화학적으로 세정하기 위한 F(불소) RADICAL을 공급하는 원격 고밀도 플라즈마를 발생시키기 위한 고출력 Generator에 대해 소개하고자 한다. 개발되어진 Generator는 입력 직류전원을 공유하여 7kW급 단일 Power Amp Module의 상호결합 및 전력분담에 대한 편차 극복을 위한 기술과 고조파 저감비가 우수한 대전력 필터를 구현하였고, 크기 및 부피의 축소를 위하여 필터의 Q Factor의 극대화 기술이 적용되어졌다. 개발된 400kHz 30kW Generator는 NF3 60리터의 대용량 Remote Plasma Source의 리액터를 구동시킬 수 있으며, 38kW급 DC Link, 7kW급 Power Amp module, LC 필터, Controller로 구성되어 진다. 개발된 장치는 실제 플라즈마 공정에서 시험 평가한 결과를 통해 검증할 수 있었다.

  • PDF

Computations of Losses and Temperatures in the Core Ends of a High Voltage Turbo-generator

  • Liu Yujing;Hjarne Stig
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.299-305
    • /
    • 2005
  • The work described in this paper is to investigate the additional iron losses and consequent temperatures in core ends of a turbo-generator wound with high voltage cables. Electromagnetic calculations are made with 3D FE models, which include the lamination material with anisotropic properties both in magnetic permeability and electric conductivity. The models also include the geometry of the stator teeth and eventually the axial steps designated to reduce the core end losses. The 3D model of the rotor consists of field windings with straight in-slot parts and end windings. The thermal models are simplified into two dimensions and include the heat sources dumped from the 3D electromagnetic solutions. The influences of power factor on additional iron losses are studied for this cable wound machine and conventional machines. The calculation results show that the additional iron losses can be reduced to about $15\%$ by introducing some small steps around the airgap corner of core ends.

Power Control of Wind Induction Generator used SVPWM Inverter (SVPWM 인버터를 이용한 풍력발전용 유도발전기 최적전력제어)

  • Choi, Sun-Pill;Kim, Dong-Wan;Kim, Choon-Sam;Lee, Hyun-Woo;Park, Han-Suk;Woo, Jung-In
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1303-1305
    • /
    • 2002
  • In this study, We proposed high efficiency wind power generator system for induction generator used SVPWM swiching inverter. First, We suggest Equivalient Circuit for Ind Generator, it's characteristics equation, and equation of slip. In addition, we suggest Pick Traction Slip control methods. adapted variable power system. We study simulation result fo suggested system and output power by slip e and we identify SVPWM of suitable wind p system by comparison between SPWM and SVPW Consequently, we show that the control result variable wind power is suitable.

  • PDF

A Study on the Voltage Drop of Induction Generator along the Rotor Shape (회전자 형상에 따른 유도발전기 전압강하에 대한 연구)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.2
    • /
    • pp.62-66
    • /
    • 2015
  • Induction generator is easy to durability and maintenance than the synchronous generator. So, recently Induction generator has been widely applied to small-scale hydroelectric power plant. When the rotor is operating faster than synchronous speed, induction machine can generate electric power. Induction generator has a large inrush currents, such as the starting current of the induction motor. Induction motor has been designed a variety of rotor shape in order to reduce starting current. Since the occurrence of high inrush current cause a voltage drop to the system, it will need to reduce possible. Because the starting current of the squirrel-cage induction motor varies in accordance with the rotor shape, it is necessary to analyze the magnitude of inrush current in order to apply to the generator. In this study, we analyzed the inrush current and the voltage drop caused in accordance with the rotor shape of 1500kw induction generator.