• Title/Summary/Keyword: High Linearity

Search Result 1,069, Processing Time 0.026 seconds

Formation and humidity-sensing properties of porous silicon oxide films by the electrochemical treatment (전기화학적 처리에 의한 다공질 실리콘 산화막의 형성과 감습 특성)

  • 최복길;민남기;류지호;성영권
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.1
    • /
    • pp.93-99
    • /
    • 1996
  • The formation properties and oxidation mechanism of electrochemically oxidized porous silicon(OPS) films have been studied. To examine the humidity-sensitive properties of OPS films, surface-type and bulk-type humidity sensors were fabricated. The oxidized thickness of porous silicon layer(PSL) increases with the charge supplied during electrochemical humidity sensor shows high sensitivity at high relative humidity in low temperature. The sensitivity and linearity can be improved by optimizing a porosity of PSL. (author). refs., figs.

  • PDF

A Study on the Mechanical and Hand Properties of the Lining Fabrics (의복 안감의 역학적 특성 및 태 평가)

  • Kim, Myung-Ok;Uh, Mi-Kyung;Park, Myung-Ja
    • Fashion & Textile Research Journal
    • /
    • v.8 no.3
    • /
    • pp.357-362
    • /
    • 2006
  • This study is to evaluate the objective sensibility of the commercial lining fabrics. Five kinds of the linings were collected by adding taffetas with four kinds of fibers (polyester, nylon, rayon, and acetate) to one polyester stretch fabric. The six basic mechanical and hand properties were studied by using KES-FB system (Kawabata Evaluation System). The result of measuring the mechanical properties shows that polyester has high bending rigidity (B), that polyester-stretch has a high value of linearity of load-extension curve (LT), tensile energy (WT), tensile resilience (RT), and coefficient of friction (MIU) and a low value of bending rigidity(B), shear property, and geometrical roughness (SMD). The nylon has a high value of bending rigidity (B), shear property, and compression resilience (RC). The rayon has a high value of coefficient of friction (MIU) and linearity of compression-thickness curve (LC) and a low value of shear property, and the acetate has a low value of shear property. The result of hand value shows that polyester, nylon, and acetate are a high value of KOSHI (stiffness), NUMERI (smoothness), and FUKURAM (fullness & softness), and they feel stiff and massive, that rayon has a low value of NUMERI and FUKURAMI. The total result of hand value shows that polyester taffeta and polyester stretch fabric are about the same as the best material for the lining of a woman's dress for spring and summer, and the next thing is acetate, but nylon and rayon are somewhat inferior materials. This provides a fundamental data for the comfortable clothing production of a higher value-added product through the study on the mechanical and hand properties of the lining as well as the right side of fabrics.

The Feasibility Study of photoconductor materials for the use of a dosimeter in Radiotherapy (광도전체 물질의 치료 방사선 선량계 적용을 위한 가능성 연구)

  • Jang, Giwon;Shin, Jungwook;Oh, Kyungmin;Park, Sungkwang;Kim, Jinyoung;Park, Jikoon;Nam, Sanghee
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.81-84
    • /
    • 2013
  • The use of the dosimetry have been increasingly recognized as high radiation energy and radiation treatment planning(RTP) have rapidly developed in radiotherapy. There are many types of detectors for the dosimetry such as ionization chamber, film, TLD, diode, and etc. Among such detectors, the diode detector uses a photoconductor materials that generate electrical signals by the incident radiation energy. Though many research groups are recently interested in such materials, there is few experimental results except for silicon in the radiation therapy field. In this study, the feasibility of photoconductor materials was verified as a dosimeter through the evaluation of response properties at a high radiation energy. For the fabricated detectors based on $HgI_2$ and $PbI_2$, reproducibility, linearity, and pulse-rate response were analyzed. Such evaluations are essential factors for the use of dosimeter. From results, linearity and reproducibility of the fabricated $HgI_2$ detector indicated about 7% error. The fabricated $PbI_2$ detector showed 1.7% error in linearity, and 12.2% error in reproducibility.

Design for Dispersion Map in Submarine Optical Network (장거리 해저 광전송망 분산보상 설계 및 구현)

  • Yoo, Jae-Duck;Park, Hong-Tae;Shin, Hyun-Sik;Kim, Chun-Suk;Shin, Yun-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.1 no.1
    • /
    • pp.56-62
    • /
    • 2006
  • Currently, Most of the Backhual and Submarine's networks are being installed using DWDM and EDFA to deal with dramatically increasing internet traffic. In a conventional type optical system, the so-called 3R repeater, fiber non- linearity was not significant factor but it is one of the most important consideration when designing new DWDM network based on the EDFAs. To minimize the signal pulse distortion in long-haul optical network, Zero-dispersion fiber is indispensable but causes the fiber non-linearity. Therefore this conflicting problems should be managed to transmit a high-speed capacity traffic. In this paper, key technologies in DWDM submarine optic network were found out for a high capacity traffic and introduced the dispersion management way for solving the conflicting problems between Zero-dispersion and non-linearity. Lastly designed a dispersion map in section between Korea and Hong-kong.

  • PDF

Image Evaluation of Resolution Parameter and Reconstitution Filter in 256 Multi Detector Computed Tomography by Using Head Phantom (256 다중 검출기 전산화단층촬영에서 두개부 전용 팬톰을 이용한 분해능 파라메터와 재구성 필터의 영상 평가)

  • Gu, Bon-Seung;Seoung, Youl-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.814-821
    • /
    • 2011
  • The purpose of this study was to evaluate of resolution parameter and reconstitution filter in the 256 multi detector computed tomography(MDCT) by using the head phantom. We used 256 MDCT, and head phantom of philips system. We evaluated to image quality by using Extended Brilliance Workspace. The protocol were axial scan method with 120 kVp, 0.5 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of field of view(FOV), $512{\times}512$ of matrix size, 1.0 of pitch, $128{\times}0.625$ mm of collimations. The resolution parameter was applied for 'Standard', 'High' and 'Ultrahigh'. The reconstitution filters were changed to seven type of 'A', 'B', 'C', 'D', 'UA', 'UB', 'UC'. The assesment factors of image quality were the uniformity, the noise, the linearity and 50% and 10% of the modulation transfer function(MTF). Finally The good image quality in 'High' resolution parameter showed at the uniformity, the linearity and 50% and 10% of MTF. The 'UA', 'UB' reconstitution filter showed at the good image quality of the uniformity and the noise and 'C' reconstitution filter showed at the same result of the linearity and 50% and 10% of MTF.

Fabrication of IMT-2000 Linear Power Amplifier using Current Control Adaptation Method in Signal Cancelling Loop (신호 제거 궤환부의 전류 제어 적응형 알고리즘을 이용한 IMT-2000용 선형화 증폭기 제작)

  • 오인열;이창희;정기혁;조진용;라극한
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.1
    • /
    • pp.24-36
    • /
    • 2003
  • The digital mobile communication will be developed till getting multimedia service in anyone, any where, any time. Theses requiring items are going to be come true via IMT-2000 system. Transmitting signal bandwidth of IMT-2000 system is 3 times as large as IS-95 system. That is mean peak to average of signal is higher than IS-95A system. So we have to design it carefully not to effect in adjacent channel. HPA(High Power Amplifier) located in the end point of system is operated in 1-㏈ compression point(Pl㏈), then it generates 3rd and 5th inter modulation signals. Theses signals affect at adjacent channel and RF signal is distorted by compressed signal which is operated near by Pl㏈ point. Then the most important design factor is how we make HPA having high linearity. Feedback, Pre-distorter and Feed-forward methods are presented to solve theses problems. Feed-forward of these methods is having excellent improving capacity, but composed with complex structure. Generally, Linearity and Efficiency in power amplifier operate in the contrary, then it is difficult for us to find optimal operating point. In this paper we applied algorithm which searches optimal point of linear characteristics, which is key in Power Amplifier, using minimum current point of error amplifier in 1st loop. And we made 2nd loop compose with new structure. We confirmed fabricated LPA is operated by having high linearity and minimum current condition with ACPR of -26 ㏈m max. @ 30㎑ BW in 3.515㎒ and ACLR of 48 ㏈c max@${\pm}$㎒ from 1W to 40W.

A New Small Size Digital Optical Ozone Monitor Using CCD Array as a UV Detector (UV 감지기로서 CCD어레이를 사용한 소형 디지털 광 오존모니터)

  • Chung, Wan-Young;Lee, Seung-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.158-163
    • /
    • 2008
  • Ozone monitor based on UV techniques has been widely used due to their signal stability. The high concentration ozone monitor for real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source and a photo multiplier tube as UV detector. The structure could be very useful for low price high concentration ozone monitor and showed good linearity to ozone in the concentration range between 0.05 and 2wt%. For accurate ambient ozone monitoring, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector. The optical signal form the CCD array was converted to digital signal, and the digital signal was displayed on screen using PC interface. The developed system showed good linearity and sensitivity in relatively low measuring range between 10ppm and 10,000ppm, and showed some feasibility of hish resolution ozone monitor using CCD array as a photodetecor.

Assaying of SNM using Simultaneous Detection of Fission Neutrons and Gammas by Employing a Novel Phoswich Detector

  • Sonu;Mohit Tyagi;A. Kelkar;A. Sahu;M. Sonawane;P.S. Sarkar;A. Pandey;D.B. Sathe;G.D. Patra;T. Vincent;S.G. Singh;R.B. Bhatt
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2662-2669
    • /
    • 2023
  • For the precise measurements of special nuclear materials (SNM) including Pu and Am isotopes, we have used phoswich detector combination of two single crystal scintillators of Gd3Ga3Al2O12:Ce and CsI:Tl. High detection efficiency and sensitivity along with high figure of merit for the discrimination of these phoswich detectors ensures the detection and discrimination of thermal neutrons and gammas from spontaneous fission of Pu and other isotopes in presence of high gamma background. Using this detector, the low energy gammas, which is stopped completely in 1mm thick disc of GGAG, can be also discriminated from high energies gamma and shows linearity in wide range of sample quantities. By changing only the appropriate shielding, the similar setup was used for thermal neutron detection and shows a very good linearity over wide range. The quantity of a test sample was also calculated accurately by using the measured calibrated plot.

Assessment of Atmospheric Greenhouse Gas Concentration Equipment Performance (대기 중 온실가스 농도 관측 장비 성능 비교 검증)

  • Chaerin Park;Sujong Jeong;Seung-Hyun Jeong;Jeong-il Lee;Insun Kim;Cheol-Soo Lim
    • Atmosphere
    • /
    • v.33 no.5
    • /
    • pp.549-560
    • /
    • 2023
  • This study evaluates three distinct observation methods, CRDS, OA-ICOS, and OF-CEAS, in greenhouse gas monitoring equipment for atmospheric CO2 and CH4 concentrations. The assessment encompasses fundamental performance, high-concentration measurement accuracy, calibration methods, and the impact of atmospheric humidity on measurement accuracy. Results indicate that within a range of approximately 500 ppm, all three devices demonstrate high accuracy and linearity. However, beyond 1000 ppm, CO2 accuracy sharply declines (84%), emphasizing the need for caution when interpreting high-concentration CO2 data. An analysis of calibration methods reveals that both CO2 and CH4 measurements achieve high accuracy and linearity through 1-point calibration, suggesting that multi-point calibration is not imperative for precision. In dynamic atmospheric conditions with significant CO2 and CH4 concentration variations, a 1-point calibration suffices for reliable data (99% accuracy). The evaluation of humidity impact demonstrates that humidity removal devices significantly reduce air moisture levels, yet this has a negligible effect on dry CO2 concentrations (less than 0.5% relative error). All three observation method instruments, which have integrated humidity correction to calculate dry CO2 concentrations, exhibit minor sensitivity to humidity removal devices, implying that additional removal devices may not be essential. Consequently, this study offers valuable insights for comparing data from different measurement devices and provides crucial information to consider in the operation of monitoring sites.

Development of the High Temperature Silicon Pressure Sensor (고온용 실리콘 압력센서 개발)

  • Kim, Mi-Mook;Nam, Tae-Chul;Lee, Young-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.175-181
    • /
    • 2004
  • A pressure sensor for high temperature was fabricated by using a SDB(Silicon-Direct-Bonding) wafer with a Si/$SiO_{2}$/ Si structure. High pressure sensitivity was shown from the sensor using a single crystal silicon of the first layer as a piezoresistive layer. It also was made feasible to use under the high temperature as of over $120^{\circ}C$, which is generally known as the critical temperature for the general silicon sensor, by isolating the piezoresistive layer dielectrically and thermally from the silicon substrate with a silicon dioxide layer of the second layer. The pressure sensor fabricated in this research showed very high sensitivity as of $183.6{\mu}V/V{\cdot}kPa$, and its characteristics also showed an excellent linearity with low hysteresis. This sensor was usable up to the high temperature range of $300^{\circ}C$.