• Title/Summary/Keyword: High Heating Value

Search Result 386, Processing Time 0.023 seconds

Study on Combustion and Explosion Hazard of Rice Bran Dusts (쌀겨 분진의 연소 및 폭발 위험성에 관한 연구)

  • 이창우;현성호;이한철;허윤행
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.93-98
    • /
    • 1999
  • We had investigated combustion properties of rice bran dusts. Decomposition of rice bran dusts with temperature were investigated using DSC and the weight loss according to temperature using TGA in order to find the thermal hazard of rice bran dusts, and the properties of dust explosion in variation of their dust with the same particle size. Using Hartman's dust explosion apparatus which estimate dust explosion by electric ignition after making dust disperse by compressed air, dust explosion experiments have been conducted by varying concentration and size of rice bran dust.According to the results for thermodynamic stability of rice bran dust, there are little change of initiation temperature of heat generation and heating value for used particle size. But initiation temperature of heat generation decreased with high heating rate whereas decomposition heat increased with particle size. Average maximum explosion pressure was $10kgf/cm^2$ for 60/70 mesh and $1.5mg/cm^2$ dust concentration.

  • PDF

Eating Qualities of Frozen Cooked Rice on the Thawing Condition (해동조건에 따른 냉동밥의 밥맛 비교)

  • 오명숙
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.2
    • /
    • pp.147-157
    • /
    • 1997
  • It attempted to determine the effect of various thawing methods, such as pressure cooking, conventional cooking, microwave heating and thawing at room temperature, on the quality of frozen cooked rice using Nongan variety of rice. These effects were analysed at three different periods-after 10 days, 30 days and 90 days. It conducted a physico-chemical analysis(moisture content, dehydration rates, color value and texture) and sensory evaluation o the frozen-thawed cooked rice. The study showed that there were no significant differences on the frozen-thawed cooked rice. The study showed that there were no significant differences on the quality characteristics of frozen-thawed cooked rice during the storage of 90 days. However, the thawing method of pressure cooking caused high moisture content and decrease in hardness on the cooked rice, the desirability for the rice didn't diminish compared with the cooked rice just after cooking. the quality characteristics of the cooked rice after frozen-thawing by conventional cooking and microwave heating were similar with that of the cooked rice just after cooking. thawing at room temperature caused a significant decrease in quality characteristics.

  • PDF

Performance Analysis of Solar Heating System for High Solar Fraction using TRNSYS (태양열 온수급탕 시스템의 TRNSYS 열성능 분석)

  • Sohn, Jin-Gug
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.59-67
    • /
    • 2012
  • In this paper, performances of solar hot water supply systems are parametrically analyzed with the variations of solar collector area, slope of collector and volume of storage. All simulations are conducted by using TRNSYS computer program. Average solar fractions, collector efficiencies and temperatures of storage are investigated monthly as well as annually. For system analysis, the maximum value of monthly average solar fractions has a limitation of 90 percent. As a result, the designed solar thermal system with $6m^2$ collector area, $50^{\circ}$ slope and $0.36m^2$ storage volume could provide almost an annual average solar fraction of 72 percent. By increasing the storage volume to $0.42m^2$, the annual solar fraction of system increases up to 73 percent.

Strip temperature control for the heating furnace in the continuous-annealing line (냉연 연속 소둔로 가열대 판온제어)

  • 정호성;유석환;백기남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.779-782
    • /
    • 1990
  • Recently batch type cold rolling processes have been replaced by continuous annealing type processes for cold rolled sheets of mild steel and high strength steel in order to obtain higher productivity, labor saving. In the continuous annealing line, it is very important to maintain the target steel strip temperature at the exit side of each furnace. The automation system of continuous annealing line is based on a hierachical composition. This paper shows how to preset the set value of furnace temperature control for the heating section in a continuous annealing line. Saying in other words, this paper presents the development of an adaptive control approach to control the exit strip temperature in the continuous annealing line. There are three parts in this approach; one is a process modelling and another is recursive parameter estimation and the other is a design of temperature controller.

  • PDF

SYNERGISTIC INTERACTION OF ENVIRONMENTAL TEMPERATURE AND MICROWAVES: PREDICTION AND OPTIMIZATION

  • Petin, Vladislav G.;Kim, Jin-Kyu;Kolganova, Olga I.;Zhavoronkov, Leonid P.
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • A simple mathematical model of simultaneous combined action of environmental agents has been proposed to describe the synergistic interaction of microwave and high ambient temperature treatment on animal heating. The model suggests that the synergism is caused by the additional effective damage arising from an interaction of sublesions induced by each agent. These sublesions are considered to be ineffective if each agent is taken individually. The additional damage results in a higher body temperature increment when compared with that expected for an independent action of each agent. The model was adjusted to describe the synergistic interaction, to determine its greatest value and the condition under which it can be achieved. The prediction of the model was shown to be consistent with experimental data on rabbit heating. The model appears to be appropriate and the conclusions are valid.

Hemi-cube algorithm and its application to thermal analysis of crystal growth furnace (반정육면체 알고리즘 및 단결성 성장로의 열해석에의 응용)

  • Lee, Seung-Bok;Jeong, Jin-Su;Go, Sang, Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.7
    • /
    • pp.905-914
    • /
    • 1998
  • View factor determination is very important in thermal analysis problems with surface radiation but it is very difficult to determine view factors for complex geometries. Exact calculation of view factors for crystal growth furnace is essential due to not only its high surface temperature but the radiation shield, complicated heating system. In this study, view factor calculation algorithm is introduced and applied to cylindrical crystal growth furnace. This algorithm is based on the Hemi-Cube Algorithm and the results obtained with this algorithm show good agreements with those of analytical solution. As an application of this algorithm, temperature profiles and heating value distributions for various furnaces are calculated and the shape criteria for better furnace are suggested.

The Development and Performance Test of a Small Wood Boiler (소형 화목보일러의 개발 및 성능시험)

  • Kim, Sa-Ryang;Lee, Jong-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.491-497
    • /
    • 2002
  • In the present study, a new wood boiler was developed through the performance test. The efficiency of the boiler was obtained up to about 63.7%, which is 67% higher than that of conventional wood boiler, about 38.2%. The structure of the new boiler is more complicated than the conventional boiler. The passage of combustion gas is sufficiently long to exchange heat well with heating water. Therefore, the obtained efficiency is so high, and the temperature of exhaust gas was lower than 200$^{\circ}C$, which is as low as that of light oil boiler. The composition of exhaust gas was measured, and the CO gas concentration was obtained more than 3000 ppm. So, it seems that more study is needed to lower the concentration of CO gas.

A Study on Mechanical Properties of Concrete at Elevated Temperatures (고온에서의 콘크리트 재료 역학적 특성에 관한 연구)

  • Park, Chan-Kyu;Kim, Gyu-Yong;Lee, Seung-Hoon;Park, Ju-Heon;Kim, Young-Sun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.769-772
    • /
    • 2006
  • The effects of high temperature on strength, elastic modulus and strain at peak stress of concrete were experimentally investigated. The type of test was the stressed test that a preload was applied to the specimen prior to heating and the load was sustained during the heating period. In this study, the level of preload was 25% of compressive strength at room temperature. All tests were conducted at various temperatures(20,100, 200, 300, 400, 500, 600 and $700^{\circ}C$) for concretes made with W/B ratios 46% and 32%. Test results showed that on the whole, the relative values of strength and elastic modulus, and the real strain value at peak stress were not influenced by the W/B ratio.

  • PDF

A Study on Contaminant Emission and Combustion of Anthracite-Bituminous Coal Blend in a Fluidized Bed Coal Combustor (유동층 연소로에서 유$cdot$무연탄 혼합 연소시 대기오염물질 배출에 관한 연구)

  • 조상원;정종현;손병현;김영식;오광중
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.28-36
    • /
    • 1996
  • The objects of this study were to investigate emissions of air pollutant the particles as well as the combustibility of the low grade domestic anthracite coal and imported high-calorific bituminous coal in the fluidized bed coal combustor. The production of air pollution from anthracite-bituminous coal blend combustion in a fluidized bed coal combustor was evaluated. The effects of air velocity and anthracite fraction on the reaching time of steady state condition was also evaluated. We used coal samples the domestic low grade anthracite coal with heating value of 2,010 kcal/kg and the imported high grade bituminous coal with heating value of 6,520 kcal/kg. The experimental results are presented as follows. The time of reaching to steady state was affected by the temperature variation. The steady state time was about 120 minute at 0.3 m/s which was the fastest. It has been found that $O_2$ and $CO_2$ concentration were reached steady state at about 100 minute. As the height of fluidized bed becomes higher, the concentration s of $SO_2$ and $NO_x$ mainly increased. The concentration of freeboard was the highest and emission concentration was diminished. Also, as anthracite fraction increased, the emission of $SO_x$ concentration was increased. But, it has been found that the variation of $NO_x$ concentration with anthracite fraction was negligible and the difference of emission concentration according to air flow rates was negligible, too. It has been found that $O_2$ concentration decreased and $CO_2$ concentration increased as the height of fluidized bed increased. As anthracite fraction increased, the mass of elutriation particles increased, and $CO_2$ concentration decreased. Also, as air velocity increased, $O_2$ concentration decreased and $CO_2$ concentration increased. Regardless-of anthracite fraction and flow rate, the combustible weight percentage in elutriation particles were high in the case of fine particles.

  • PDF

Study on Movement of Wood (목재(木材)의 치수변동(変動)에 관(關)한 연구(硏究))

  • Jung, Hee-Suk;Lee, Phil-Woo;Lee, Nam-Ho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.36-42
    • /
    • 1986
  • Both the control and heated specimen of oak, hornbean, alder, poplar, red pine and pitch pine among domestic commercial species and taun imported were used for radial and tangential shrinkage and movement that occurred on changing the relative humidity of the atmosphere from 90 percent to 60 percent at $25^{\circ}C$. The results of this study were as follows. 1. The radial and tangential shrinkage of the control and heated hornbean and oak wood, except alder, of high specific gravity showed greater than species with low specific gravity. The ratio of tangential to radial shrinkage was 1.46 for taun to 2.70 for alder. Green volume specific gravity of the heated and soaked specimen of all species except poplar decreased 1.5 to 3.1 percent. Shrinkage of the heated specimen increased more than that of the control specimen, and antishrink efficiency of all timbers except alder had negative value. Shrinkage from green to air dry of treated specimens increased more than case of total shrinkage, and radial shrinkage of those specimen increased greater than tangential shrinkage. 3. The movement of the heating specimen for 120 hours decreased than those of the control and the heating specimen for 240 hours. The movement of heating oak, poplar, red pine and pitch pine (or 240 hours increased rather than those of the control specimen.

  • PDF