• Title/Summary/Keyword: High Frequency Attenuation

Search Result 240, Processing Time 0.026 seconds

50-300 keV X-ray Transmission Ratios for Lead, Steel and Concrete

  • Tae Hwan Kim;Kum Bae Kim;Geun Beom Kim;Dong Wook Kim;Sang Rok Kim;Sang Hyoun Choi
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.164-171
    • /
    • 2022
  • The number of facilities using radiation generators increases and related regulations are strengthened, the establishment of a shielding management and evaluation technology has become important. The characteristics of the radiation generator used in previous report differ from those of currently available high-frequency radiation generators. This study aimed to manufacture lead, iron, and concrete shielding materials for the re-verification of half-value layers, tenth-value layers, and attenuation curve. For a comparison of attenuation ratio, iron, lead, and concrete shields were manufactured in this study. The initial dose was measured without shielding materials, and doses measured under different types and thicknesses of shielding material were compared with the initial dose to calculate the transmission rate on 50-300 kVp X-ray. All the three shielding materials showed a tendency to require greater shielding thickness for higher energy. The attenuation graph showed an exponential shape as the thickness decreased and a straight line as the thickness increased. The difference between the measurement results and the previous study, except in extrapolated parts, may be due to the differences in the radiation generation characteristics between the generators used in the two studies. The attenuated graph measured in this study better reflects the characteristics of current radiation generators, which would be more effective for shield designing.

Noise Attenuation by Vegetation (식생에 의한 소음감쇄 효과)

  • 박달곤;김용식
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.23 no.2
    • /
    • pp.205-212
    • /
    • 1995
  • The effects of noise attenuation among bare land, grassland, dominated broad-leaved (Quercus acutissima Carruth) and dominated coniferous forest (Pignus rigid Mill.) were studied For this study, the field experiment was carried out at playground, orchard grass, and school forest in Yeungnam University, Kyongsan. Sound levels of 500, 630, 800, 1,000, 1,250, 1,600, 2,000, 2,500 and 3,150 Hz, respectively, were projected into the vegetation, and the transmitted levels of sound were recorded at the distances of 1, 5, 10, 20, 30 and 50m, respectively, from the sound source. Both dominated coniferous forest (Pignus riged Mill.) and broad-leaved forest (Quercus acutissima Carruth ) are the more effective than grassland in the rates of attenuation. It is expected that dominated coniferous forest will be the more effective to attenuate sound love교 than dominated broad-leaved forest. In the low frequencies such as 500 and 630 Hz, grassland showed the more effective to attenuate sound levels than forests, while in the high frequency such as 3,150 Hz, the forests are the more effective to attenuate sound levels than grassland The present results suggested that it is the more effective to establish the tree belt for a sound barrier, with dominated coniferous tree species in the upper layer and herbaceous vegetation in the lower layer.

  • PDF

Material Charcterization of MR Fluids at High Frequencies (고주파 영역에서의 MR유체 특성연구)

  • Park, Kyoung-mi;Kim, Jae-hwan;Park, Seung-Bok;Kim, Kyung-Su
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.327.1-327
    • /
    • 2002
  • MR(Magnetorheogical) fluid composed of fine iron powders dispersed in silicon oil is utilized to many smart structures and devices because of its significant rheological property change by the application of an external magnetic field. When we deal with the shock wave attenuation of warship structures, we should be able to characterize the high frequency behavior of MR fluids. So far, however, much efforts have been focused on the material characterization of MR fluids at low frequencies below 100㎐. (omitted)

  • PDF

A New Approach on the Scattering of Electromagnetic Radiation for Spherical Raindrop by the Invariant Imbedding Method

  • 이경동;이동훈;김기홍
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.35-35
    • /
    • 2003
  • In satellite communication, attenuation, scattering, and depolarization of relatively high frequency waves such as millimeter waves are strongly influenced by rain. In order to study the rain attenuation, we introduce a new theoretical method, which enables us to obtain the reflection and transmission coefficients in arbitrary medium. We adopt this method to examine how the electromagnetic radiation is affected by homogeneous spherical raindrops. It is assumed that the raindrop shape is spherical and linearly locate in one direction. For the radiation of wave in raindrops, we consider the effective permittivity, in which the raindrop is assumed to be spherical. By adopting the invariant imbedding approach, the 1st order differential equations are derived for the reflection and transmission coefficients. We investigate the transmission and reflection of waves for various incident angles when the spherical raindrops are assumed to have random sizes.

  • PDF

New Density-Independent Model for Measurement of Grain Moisture Content using Microwave Techniques

  • Kim, Jong-Heon;Kim, Ki-Bok;Noh, Sang-Ha
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.4
    • /
    • pp.72-78
    • /
    • 1997
  • A free space transmission method using standard gain horn antennas in the frequency range from 9.0 to 10.5GHz is applied to determine the dielectric properties of grain such as rough rice ,brown rice and barley. The dielectric constant and loss factor, which depend on the moisture content of the wetted grain are obtained from the measured attenuation and phase shift by vector network analyzer. The moisture content of grain varied from 11 to 25% based on this wetted condition. The measured values of dielectric constants as a function of moisture density are compared with values of those obtained using he predicted model for estimating dielectric constants of grain. The effect of density fluctuation, high is an important parameter governing the dielectric properties of grain, on the dielectric constant and loss factor is presented. A new density-independent model in terms of measured attenuation an moisture density is proposed of reducing the effects of density fluctuation on the moisture content measurement.

  • PDF

Mechanical Properties and Ultrasonic Parameters of the Apple Flesh while in Storage (저장기간에 따른 사과 과육의 기계적 특성 및 초음파 파라미터)

  • 김기복;김만수;정현모;이상대
    • Journal of Biosystems Engineering
    • /
    • v.28 no.3
    • /
    • pp.239-244
    • /
    • 2003
  • The potential use of ultrasonic technique for firmness measurement of apples was evaluated. Mechanical properties(bioyield deformation, bioyield strength, rupture deformation, ultimate strength, and elastic modulus) and ultrasonic parameters (ultrasonic velocity, attenuation coefficient and the first peak frequency) of the apple flesh during the storage time were measured and analyzed. Ultrasonic parameters were determined from the measurement of ultrasonic wave transmission through the apple flesh specimen. Mechanical properties were obtained by universal testing machine. The bioyield strength, rupture strength, elastic modulus, ultrasonic velocity, and the first peak frequency of the apple flesh decreased with the storage time. The bioyield deformation, rupture deformation, and ultrasonic attenuation coefficient increased with the storage time. The correlation analysis between ultrasonic parameters and mechanical properties and the storage time was performed. The high correlations were found between the storage time and the ultrasonic parameters, and these relationships seem to be useful for determining the firmness of the apple flesh.

Compact Multi-harmonic Suppression LTCC Bandpass Filter Using Parallel Short-Ended Coupled-Line Structure

  • Wang, Xu-Guang;Yun, Young;Kang, In-Ho
    • ETRI Journal
    • /
    • v.31 no.3
    • /
    • pp.254-262
    • /
    • 2009
  • This paper presents a novel simple filter design method based on a parallel short-ended coupled-line structure with capacitive loading for size reduction and ultra-broad rejection of spurious passbands. In addition, the introduction of a cross-coupling capacitor into the miniaturized coupled-line can create a transmission zero at the second harmonic frequency for better frequency selectivity and attenuation level. The aperture compensation technique is also applied to achieve a strong coupling in the coupled-line section. The influence of using the connecting transmission line to cascade two identical one-stage filters is studied for the first time. Specifically, such a two-stage bandpass filter operating at 2.3 GHz with a fractional bandwidth of 10% was designed and realized with low-temperature co-fired ceramic technology for application in base stations that need high power handling capability. It achieved attenuation in excess of -40 dB up to $4f_0$ and low insertion loss of -1.2 dB with the size of 10 mm ${\times}$ 7 mm ${\times}$ 2.2 mm. The measured and simulated results showed good agreement.

The Material Constants and Microwave Absorbing Characteristics of ferroxplana Composite Microwave Absorber (복합 ferroxplana 전파흡수체의 재료정수와 전파흡수 특성)

  • 신재영;오재희
    • Journal of the Korean Magnetics Society
    • /
    • v.1 no.2
    • /
    • pp.49-54
    • /
    • 1991
  • In this study the correlation between material constants and microwave absorbing characteristics of ferroxplana composite microwave absorber used in X-band was investigated. The real part of permeability(${\mu}_{r}'$) was decreased and the imaginary part of permeability(${\mu}_{r}"$) of ferroxplana composite was increased with increaing ferroxplana loading ratio(F/R). The frequency showing maximum attenuation was shifted to lower frequency with increasing absorber thickness. The absorber 2.6 mm thick showed good band width property and 3.2 mm thick showed good attenuation property. From the apphcation of ferroxplana composite's material constants to the region of material constants which satisfy broad band width, it is found that the absorbing characteristics were estimated quantitatively. Estabhshment of material constants' region which satisfies broad band width can make practical application to design of high performance ferrite microwave absorber.

  • PDF

Issues and Improvement Methods of the Bridge Tab in Customer Premises Telecommunications Facilities for High-Speed Communication Network (초고속통신망을 위한 구내통신 설로설비의 브릿지 탭의 문제점과 개선 방안)

  • Min, Gyeong-Ju;Hong, Jae-Hwan;Nam, Sang-Sig;Kim, Jeong-Ho
    • The KIPS Transactions:PartC
    • /
    • v.13C no.7 s.110
    • /
    • pp.881-888
    • /
    • 2006
  • The position of the bridged tap is determined by that of the outlet in most modern apartments, since most of the indoor wiring utilizes the bus wiring structure when deploying the indoor communication line. These bridged taps deteriorate transmission performance in the specific frequency at the time of high-speed multimedia communication, which uses a high frequency bandwidth, since the duality of return loss worsens and line attenuation increases rapidly. As a result, analysis on this phenomenon is required. In this study, the test model is created by modeling the intercommunication facility of the apartment that is the most representative residential house type, and by understanding the structure and the environment of the indoor wiring. Also, how the bridge tap affects performance is analyzed when the VDSL service is provided, so that problems of intercommunication lines can be identified and methods for improving the proper intercommunication line can be suggested, which is suitable for accommodating high-speed multimedia service of the future.

A Study on the Diplexer Switch of High Isolation Using Varactor Diode (바랙터 다이오드를 이용한 높은 격리도를 갖는 DIPLEXER 스위치에 관한 연구)

  • Kang Myung-Soo;Park Jun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.4
    • /
    • pp.178-184
    • /
    • 2005
  • In this paper, using diplexer structure and varactor diode controlled by reverse bias voltage for diplexer switch gives possibilities to improve isolation and current characteristics. 1 have newly designed switch with high isolation by application varactor diode corresponding to capacitor of diplexer. The low-pass filter for proposed tunable diplexer passes the microwave signal in the bandwidth for wireless cellular network systems and high-pass filter passes it in the bandwidth for wireless personal communication services (PCS) network systems. As the capacitance of the low-pass filter increases, the cut-off frequency can be moved to low frequency, so that the switch is on state in cellular bandwidth and off state in the PCS bandwidth, in contrast to, as the capacitance for attenuation characteristic of high-pass filter increases, it can be moved to high frequency, so that the switch is off state and on state in the cellular bandwidth. it is possible to improve isolation and current consumption characteristics by application diplexer design methods and varactor diode. 1 expect that the tunable diplexer circuit and design methods should be able to find applications on MMIC and low temperature copired ceramic (LTCC).