• Title/Summary/Keyword: High Frequency

Search Result 18,855, Processing Time 0.056 seconds

Review on Gallium Nitride HEMT Device Technology for High Frequency Converter Applications

  • Yahaya, Nor Zaihar;Raethar, Mumtaj Begam Kassim;Awan, Mohammad
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.36-42
    • /
    • 2009
  • This paper presents a review of an improved high power-high frequency III-V wide bandgap (WBG) semiconductor device, Gallium Nitride (GaN). The device offers better efficiency and thermal management with higher switching frequency. By having higher blocking voltage, GaN can be used for high voltage applications. In addition, the weight and size of passive components on the printed circuit board can be reduced substantially when operating at high frequency. With proper management of thermal and gate drive design, the GaN power converter is expected to generate higher power density with lower stress compared to its counterparts, Silicon (Si) devices. The main contribution of this work is to provide additional information to young researchers in exploring new approaches based on the device's capability and characteristics in applications using the GaN power converter design.

A Study on the Efficiency Improvement of Boost Converter for Power Factor Correction (PFC용 부스트 컨버터의 효율 개선에 관한 연구)

  • Jeon, Nae-Suck;Jeon, Su-Kyun;Lee, Sung-Geun;Kil, Guyng-Suk;Kim, Yoon-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1094-1096
    • /
    • 2002
  • A new technique for improving the efficiency of single-phase high-frequency boost converter is proposed. This converter includes an additional low-frequency boost converter which is connected to the main high-frequency switching device in parallel. The additional converter is controlled at lower frequency. Most of the current flows in the low-frequency switch and so, high-frequency switching loss is greatly reduced accordingly. Both switching device are controlled by a simple method; each controller consists of a comparator, a frequency generator and an error amplifier. The converter works cooperatively in high efficiency and acts as if it were a conventional high-frequency boost converter with one switching device, The proposed method is verified by simulation and experiment. This paper describes the converter configuration and design, and discusses the steady-state performance concerning the switching loss reduction and efficiency improvement.

  • PDF

Research for the Effect of Accumulator and the High Frequency-Hydraulic System of Frequency Characteristics by Experimental Method (고주파 유압시스템의 주파수 특성과 축압기 효과의 실험적 연구)

  • Park, Nam-Eun;Kim, Jae-Soo;Kim, Yang-Soo;Kim, Jong-Rok;Rho, Hyung-Woon;Jeon, Seung-Bae;Na, Hong-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.3 s.20
    • /
    • pp.51-57
    • /
    • 2003
  • Characteristics of the high frequency pulsatile flow have been investigated experimentally to understand the flow phenomena in the hydraulic system. One axis fatigue test bed, which is widely used for automobile field test, is used. Four pressure transducers, an amplifier and a A/D convertor are used to obtain the high frequency pulsatile pressure waveform in hydraulic system. The characteristics of frequency are analyzed by power spectrum method. According to the variations of pump input pressure and actuator acceleration frequency, the pressure is measured with or without an accumulator. The amplitude of pressure with accumulator is very lower than those without accumulator due to absorbing function of accumulator. As the frequency of actuator acceleration is increased, the effect of accumulator become very important to decrease the amplitude of pulsatile pressure waveform with high frequencies.

Design and Implementation of Medical Compound Stimulator Using Low/High Frequency and Cooling Stimulation (저주파/고주파와 냉자극을 이용한 의료용 조합 자극기의 설계 및 구현)

  • Yoon, Wan-Oh;Kang, Suk-Youb;Jung, Jin-Ha;Choi, Sang-Bang
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.1
    • /
    • pp.82-87
    • /
    • 2008
  • In this paper, the study was carried out to design and implement the medical compound stimulator based on the preexisting individual medical stimulators with Low frequency, High frequency and cooling stimulation. The proposed equipment is designed to compound all the functions including a cooling stimulation with a range of $0{\sim}20^{\circ}C$ and the verified low and high frequencies of 250Hz, 500Hz, 1KHz and 1MHz respectively from the previous clinical experiment with a consideration of its credibility and efficiency. Also, it was constructed by using a new technique, thermoelectricity semiconductor with a consideration of miniaturization and stability. In accordance with patients' treatment purpose, the hand piece of low frequency/cooling stimulation and High frequency/cooling stimulation were separately designed for convenience. The frequency, accuracy and other factors of implemented medical compound stimulator was satisfied according to its measurement. It was also tested by Korean Testing Laboratory (KTL) for its stability and efficacy and it confirmed that the medical compound stimulator is suitable for use as it fits in with the medical equipment standards.

The analgesic effect of combined electroacupuncture at Hoku (LI4) and Zusanli (ST36) using TFL (합곡혈(合谷穴)과 족삼리혈(足三里穴) 병용자극(倂用刺戟)이 TEL에 미치는 영향)

  • Baek, Kyong-Won;Ko, Eun-Sang;Min, Byung-Il;Park, Dong-Suk
    • Journal of Acupuncture Research
    • /
    • v.18 no.1
    • /
    • pp.76-87
    • /
    • 2001
  • Objective : Zusanli(ST36) and Hoku(Li4) are analgesic acupuncture points frequently used for acupuncture in Oriental medicine. The present study was conducted to see the antinociceptive effects produced by electroacupuncture combined two frequencies(Low, High) and two different acupuncture points(LI4, ST36) in the rat tail flick test. Method : In this study the Rats (Sprague-Dawley, 250-300g) were partially anesthetized with thiopental sodium(40mg/kg, i.p.). The basal reaction time for the tail-flick was 3${\pm}$0.5 sec. Low frequency(3Hz, 5V, biphasic) and high frequency(100Hz, 5V, biphasic) were applied to the inserted needle for the period of insertion(twenty minutes). Experimental groups are divied as follow; a) electroacupuncture stimulation groups at Hoku with or high frequency(L-EA, H-EA), b) electroacupuncture stimulation groups at Zusanli with low or high frequency(1-EA, h-EA), c) low frequency at Hoku and Zusanli(LIEA), d) low frequency at Hoku and high frequency at Zusanli(LhEA), e) high frequency at Hoku and low frequency at Zusanli(HIEA), f) high frequency at Hoku and Zusanli(HhEA) Results : The individual stimulation at either Hoku or Zusanli with low frequency has stronger and longer analgesic effect than high frequency stimulation. In addition, the combined stimulation at Hoku and Zusanli with low frequency has superior effect to individual stimulation with low frequency. LhEA and LIEA have superior effect to other stimulation groups among the combined groups. In order to determine the involvement of opioid system on the different antinociceptive effects, Naloxone, an opioid antagonist, was used in the combined groups. LIEA is the most sensitive when naloxone was administrated among study groups. HhEA is the least sensitive in the administration of naloxone. Conclusion : From results, this study confirmed that the opioid system is involved in analgesic effect of low frequency stimulation of acupuncture point, and we also can suggest the stronger analgesic effect of combining stimulation points is due to the theory of spatial summation in the nervous system.

  • PDF

A Study on Low Phase Noise Frequency Synthesizer Design with Compact Size for High Frequency Band (고주파용 소형 저 위상잡음 주파수 합성기 설계에 관한 연구)

  • Kim, Tae-Young
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.450-457
    • /
    • 2012
  • In this paper, we designed low phase noise frequency synthesizer with compact size for High frequency band (Ku-band). The paper addresses merits and demerits of single loop and dual loop frequency synthesizer. The phase noise characteristics of the phase-locked loop frequency synthesizer were predicted based on the analysis for phase noise contribution of noise sources. The proposed model in this paper more accurately predicts the low phase noise frequency synthesizer with compact size for high frequency band.

Association between eating habits, sweet taste assessment, and high-sugar food consumption among elementary school students in Daegu: a descriptive study (대구지역 초등학생의 식습관, 단맛 미각 판정 및 당류 급원 식품 섭취 간 상관성 연구)

  • Min-Jung, Kim;Eun-Kyung, Shin;Yeon-Kyung Lee
    • Korean Journal of Community Nutrition
    • /
    • v.28 no.2
    • /
    • pp.104-113
    • /
    • 2023
  • Objectives: The purpose of this study was to analyze high-sugar food consumption habits frequency among elementary school students, and their correlations with eating habits and sweet taste assessment. Methods: The participants of the study were 164 elementary school students in Daegu, in the fifth or sixth grade, along with their parents. A questionnaire investigated eating habits, high-sugar food consumption habits and frequency, and sweet taste assessment. Results: The average eating habits score for elementary school students was determined to be 71.7 out of 100. Students with higher eating habits scores had lower high-sugar food consumption habits and frequency compared to those with lower eating habits scores. Sweet taste assessment revealed that students who preferred less sweetness chose a 5% sugar concentration, those with a preference for normal sweetness chose a 10% sugar concentration, and those who preferred sweeter tastes chose a 20% sugar concentration. Sweet taste assessment showed that students who tended to prefer less sweetness had the highest eating habits scores and the lowest scores for high-sugar food consumption habits and frequency. In addition, eating habits scores were found to be negatively correlated with high-sugar food consumption habits, high-sugar food consumption frequency, and sweet taste assessment. The sweet taste assessment was positively correlated with high-sugar food consumption habits and frequency. Conclusions: Our results indicate that students with good eating habits had more desirable overall sugar intake habits, and when the preference for sweetness was high, the frequency of high-sugar food consumption was also high. Our study highlights the importance of educating elementary school students and their parents about the harmful effects of excessive sugar consumption, as well as the benefits of adopting healthy eating habits and creating supportive environments.

Development of High Strength Center-pillar by High Frequency Induction Heating (고주파유도가열에 의한 고강도 센터필라 개발)

  • Son, Jin-Hyug;Yum, Young-Jin;Kim, Won-Hyuck;Hwang, Jung-Bok;Kim, Sun-Ung;Yoo, Seung-Jo;Lee, Hyun-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.6
    • /
    • pp.533-539
    • /
    • 2008
  • An high frequency induction hardening technology of vehicle body press-formed of thin sheet steel has been developed to increase the strength of vehicle body parts locally by high frequency induction heating, thereby eliminating the need for reinforcements. And this technique for increasing the tensile strength of sheet steel was practically applied to the front floor cross member and center pillar reinforcement of a passenger car. The side impact behavior has been investigated when induction hardening technology is applied to the conventional low-carbon steel and weight reduction of an automotive body is expected. In this paper, basic experiments were performed for the hat-shaped specimen under high frequency induction heating process. Martensitic transformation was found in the heating zone through microscopic observation which showed higher hardness. In addition, the hardness and strength of the center-pillar specimen made of boron steel increased remarkably by high frequency induction heating.

High Frequency and High Luminance AC-PDP Sustaining Driver

  • Choi Seong-Wook;Han Sang-Kyoo;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.73-82
    • /
    • 2006
  • Plasma display panels (PDPs) have a serious thermal problem, because the luminance efficiency of a conventional PDP is about 1.5 1m/W and it is less than $3\~5\;lm/W$ of a cathode ray tube (CRT). Thus there is a need for improving the luminance efficiency of the PDP. There are several approaches to improve the luminance efficiency of the PDP and we adopted a driving PDP at high frequency range from 400kHz up to over 700kHz. Since a PDP is regarded as an equivalent inherent capacitance, many types of sustaining drivers have been proposed and widely used to recover the energy stored in the PDP. However, these circuits have some drawbacks for driving PDPs at high frequency ranges. In this paper, we investigate the effect of the parasitic components on the PDP itself and on the driver when the reactive energy of the panel is recovered. Various drivers are classified and evaluated based on their suitability for high frequency drivers. Finally, a current-fed driver with a DC input voltage bias is proposed. This driver overcomes the effect of parasitic components in the panel and driver. It fully achieves a ZVS of all full-bridge switches and reduces the transition time of the panel polarity. It is tested to validate the high frequency sustaining driver and the experimental results are presented.

Utililty-Interfaced High-Frequency Flyback Transformer Linked Sinewave Pulse Modulated Inverter for a Small Scale Renewable Energy Conditioner

  • Chandhaket, Srawouth;Koninish, Yoshihiro;Nakaoka, Mutsou
    • Journal of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.112-123
    • /
    • 2002
  • This paper presents a novel prototype of the utility AC power interfaced soft-switching sinewave pulse modulated inverter using the high-frequency flyback for the small scale distributed renewable energy power conditioner. The proposed cricuit with a high-frequency isolation link has a funtion of electrical isolation, which is more cost-effective and reliable for the small-scale distributed renwal energy utilization system from a safety point of riew. The discontinuous conduction mode(DCM) operation of the high-frequency flyback transformer is adopted to establish a simple and low-cost circuit configuration and control scheme. For the simplicity, the circuit operating principle is described on the basis of the modified conventional full bridge inverter, whitch is the typical conventional high-frequency full-bridge inverter employing the high requency flyback transformer to eanble the effictive function of the electrical isolation. Than, the new circuit topology of the unility-interfaced soft-switching sinewave pulse modulated inverter using IGBTs is proposed. The proposed cricuit topology is additionally composed of the auxiliary power regenerating snubber cricuits, which are also mathematically analyzed for the parameter desigen settings. Finally, the performance of the propose inverter is evaluated on the basis of computer-aid simulation. It is noted that the sinewave pulse modulated output current of the inverter is synchronous to the AC main voltage.