• Title/Summary/Keyword: High Dose Rate

Search Result 896, Processing Time 0.032 seconds

High-Dose-Rate Brachytherapy for Uterine Cervical Cancer : The Results of Different Fractionation Regimen (자궁경부암의 고선량률 근접치료 : 분할선량에 따른 결과 비교)

  • Yoon, Won-Sup;Kim, Tae-Hyun;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.228-236
    • /
    • 2002
  • Purpose : Although high-dose-rate (HDR) brachytherapy regimens have been practiced with a variety of modalities and various degrees of success, few studies on the subject have been conducted. The purpose of this study was to compare the results of local control and late complication rate according to different HDR brachytherapy fractionation regimens in uterine cervical cancer patients. Methods and Materials : From November 1992 to March 1998, 224 patients with uterine conical cancer were treated with external beam irradiation and HDR brachytherapy. In external pelvic radiation therapy, the radiation dose was $45\~54\;Gy$ (median dose 54 Gy) with daily fraction size 1.8 Gy, five times per week. In HDR brachytherapy, 122 patients (Group A) were treated with three times weekly with 3 Gy to line-A (isodose line of 2 cm radius from source) and 102 patients (Group B) underwent the HDR brachytherapy twice weekly with 4 or 4.5 Gy to line-A after external beam irradiation. Iridium-192 was used as the source of HDR brachytherapy. Late complication was assessed from grade 1 to 5 using the RTOG morbidity grading system. Results : The local control rate (LCR) at 5 years was $80\%$ in group A and $84\%$ in group B (p=0.4523). In the patients treated with radiation therapy alone, LCR at 5 years was $60.9\%$ in group A and $76.9\%$ in group B (p=0.2557). In post-operative radiation therapy patients, LCR at 5 years was $92.6\%$ In group A and $91.6\%$ in group B (p=0.8867). The incidence of late complication was $18\%$ (22 patients) and $29.4\%$ (30 patients), of bladder complication was $9.8\%$ (12 patients) and $14.7\%$ (15 patients), and of rectal complication was $9.8\%$ (12 patients) and $21.6\%$ (22 patients), in group A and B, respectively. Lower fraction sized HDR brachytherapy was associated with decrease in late complication (p=0.0405) (rectal complication, p=0.0147; bladder complication, p=0.115). The same result was observed in postoperative radiation therapy patients (p=0.0860) and radiation only treated patients (0=0.0370). Conclusion : For radiation only treated patients, a greater number of itemized studies on the proper fraction size of HDR brachytherapy, with consideration for stages and prognostic factors, are required. In postoperative radiation therapy, the fraction size of HDR brachytherapy did not have much effect on local control, yet the incidence of late complication increased with the elevation in fraction size. We suggest that HDR brachytherapy three times weekly with 3 Gy could be an alternative method of therapy.

Disinfection of E. coli from Wastewater using a Non-contact type UV Photoreactor and Log Inactivation Index (비접촉식 자외선 광반응조를 이용한 하수 대장균의 살균과 Log 불활성화율 지표)

  • Kim, Sunghong;Kim, Kyungmyun;Kim, Gwangil;Choe, Jaewan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.2
    • /
    • pp.139-145
    • /
    • 2016
  • Disinfection of microorganisms using UV light is widely used in the field of water supply and wastewater treatment plant, In spite of high germicidal effect and relatively clean by-product, UV disinfection has fundamental defeat that is accumulation of fouling materials at the interface of water and lamp sleeve. Non-contact type of UV photoreactor which can avoid this fouling generation was developed and the experimental performance evaluation of the system was carried out in this study. Log inactivation rate of E. coli was selected as a disinfection index. The concentration of E. coli of second clarifier effluent was $8.2{\times}10^1-8.2{\times}10^3$ colony per mL and was well inactivated by the non-contact type of UV photoreactor. Under the UV intensity condition of $2.1-2.5mW/cm^2$, E. coli removal rate was observed in the range of 54 - 95% when the HRT was increased from 10 to 52 seconds. Experimental results showed that log inactivation of E. coli was proportional to UV dosage and $200mJ/cm^2$ of UV dose is expected for the 2.0 log inactivation of E. coli from the second clarifier effluent. Between the two parameters of UV intensity and contact time which are consist of UV dose, UV intensity was 4 times more effective than contact time.

A Study of Small Radiation Dosimeter by Using Microfilm and Carbon Elecrtode (마이크로필름과 탄소막 전극을 이용한 소형방사선측정기 개발에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.59-62
    • /
    • 2004
  • We developed very small parallel plate radiation detector by using our existing experience of mating radiation dosimeter and capability of analyzing characteristics of dosimeter. The radiation detector was consisted of microfilm and carbon electrode. The detector was parallel plate type of all-filled ionization chamber. The ionization chamber had been fabricated using an acrylic plate for the air cavity and carbon coated microfilm for electrical configuration. The alr gap between two electrodes was 0.48 mm. The diameters of collect electrode and guard electrode were 3.3 mm, 5 mm respectively. The diameter of high voltage electrode was 5 mm. Nominal sensitive volume of the chamber was 0.016 ㎤. The major parameters of the chamber characteristics such as leakage current, reproducibility, dose rate effect, and polarity effect were measured. The experimental results were as followings. Leakage current was 0.1 pA. Standard deviation of reproducibility was less than 0.1%. Dose rate effect was less than 1.5%. Polarity effect was less than 2.4%. These data were comparable to those of commercially available dosimetric system for QA-purpose. As the result, we found that the radiation detector consisting of the ionization chamber, microfilm and carbon electrode, was satisfactory for the purpose of the small field dosimetry in size and characteristics. In the future, We will try to refine the dosimeter for use in very small volume.

  • PDF

The Role of High Dose Rate (HDR) Intracavitary Radiation Therapy for the Management of Nasopharyngeal Carcinoma (비인강암 환자의 고선량 강내 방사선 치료의 효과)

  • Cho, Jeong-Gill;Chang, Hye-Sook;Choi, Eun-Kyung
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.91-96
    • /
    • 1993
  • From September 1989 to June 1992,22 patients with nasopharyngeal carcinoma were treated in Asan Medical Center with an external beam of 60 Gy followed by a boost dose of 15 Gy HDR brachytherapy. There were 5 females and 17 males with median age of 44 years (range: 20-69 years). All patients were histologically confirmed and staged by physical examination, CT scan and/or MRI. By the AJCC TNM staging system, there were 2 patients with stge II (T2NO), 4 with stage III (T3NO, T1-3N1), and 16 with stage IV (T4 or N2-3). Four patients received chemotherapy with 5-FU and cisplatin prior to radiotherapy. All patients were followed up periodically by a telescopic examination and radiologic imaging study of CT scan or MRI with a median follow-up time of 13 months (range: 3-34 months). Twenty one patients showed a complete response ore month after completing therapy and one patient showed a complete response after three months. At the time of this analysis, seventeen patients remain alive without evidence of disease, but four patients developed distant metastasis and one patient died a month after treatment. The local control rate was $100{\%}$ in a median follow-up time of 13 months. The two year overall and disease free survival rates by the Kaplan-Meier method were $94{\%}$ and $67{\%}$, respectively. Serious radiation sequelae have not been observed yet. Although longer follow-up is needed, this retrospective analysis suggests that HDR brachytherap. given as a boost therapy for nasoharyngeal carcinoma may improve the local control. To reduce the incidence of distant metastasis, we need to develop a more effective systemic chemotherapy.

  • PDF

Effect of Gamma Irradiation on Water Uptake Rate and Gelatinization of Brown Rice (감마선 조사가 현미의 수화속도 및 호화양상에 미치는 영향)

  • Lee, You-Seok;Shu, Chung-Sik;Lee, Ju-Woon;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.900-904
    • /
    • 2004
  • Effects of gamma irradiation on brown rice quality were evaluated. Brown rice was irradiated at absorbed dose of 1, 3 or 5 kGy, and ground. Water uptake, pasting properties, and physicochemical characteristics of flour samples were tested. Water uptake rates of irradiated samples were higher than that of control, and were dose-dependent. Hydration capacity decreased in sample irradiated at 5 kGy due to leaching out of soluble compounds, whereas no differences were observed among other irradiated samples and control. Irradiation significantly decreased pasting properties as determined by amylograph. Gamma irradiation accelerated water evaporation at high temperatures (over $300^{\circ}C$) in test of weight-loss profile with thermogravimetric analyzer.

General Pharmacology of SB-31$\circledR$ (SB-31$\circledR$의 일반약리작용)

  • 박우규;천혜경;권경자;윤여생;신화섭;공재양
    • Biomolecules & Therapeutics
    • /
    • v.5 no.4
    • /
    • pp.369-375
    • /
    • 1997
  • General pharmacological effects of SB-31$^{R}$, the extracts of Pulsatilla koreana, were investigated in mice, rats and guinea-pigs. Intravenous injection of SB-31 (3 and 6 ml/kg) produced almost no effect on central nervous system no effects on the general symptom and behaviors of mice, spontaneous locomotor activity, pentobarbital- induced sleeping time , rotared performance , electroshock and pentylenetertrazole -induced seizures, acetic acid-induced writhing and normal body temperature in mice. SB-31 showed little effects on the spontaneous movement of the isolated ileum and contraction induced by agonists in isolated ileum, suggesting no influence on autonomic nervous system. Administration of SB-31 also did not show any effect on blood pressure in conscious rats. However, a slight decrease in heart rate was observed at high doses (6 and 10 ml/kg) of SB-31 in conscious rats. Similarly, a slight increase in respiratory rate was observed at 6 m1/kg of SB-31 in anesthetized rats. SB-31 did not produce any effect at the dose of 3 ml/kg, but showed a tendency to increase the urinary volume at 6 ml/kg, and produced a decrease in urinary excretions of N $a_{+}$and $K_{+}$at 6 ml/kg. However, transport capacity within the gastrointestinal tract and the secretion of the gastric juice were not influenced by 6 ml/kg of SB-31. In conclusion, these results suggest that SB-31 did not pro-duce any acute effects on the central nervous system, autonomic nervous system, respiratory and circulatory systems, digestive system and kidney function at the dose of below 3 ml/kg.ml/kg.

  • PDF

Performance Analysis of Low-level Radiation Shielding Sheet with Diamagnetic Nanoparticles

  • Cho, Jae-Hwan;Kim, Myung-Sam
    • Journal of Magnetics
    • /
    • v.20 no.2
    • /
    • pp.103-109
    • /
    • 2015
  • In this study, the authors attempted to produce a medical radiation shielding fiber that can be produced at a nanosize scale and that is, unlike lead, harmless to the human body. The performance of the proposed medical radiation shielding fiber was then evaluated. First, diamagnetic bismuth oxide, an element which, among elements that have a high atomic number and density, is harmless to the human body, was selected as the shielding material. Next, 10-100 nm sized nanoparticles in powder form were prepared by ball milling the bismuth oxide ($Bi_2O_3$), the average particle size of which is $1-500{\mu}m$, for approximately 10 minutes. The manufactured bismuth oxide was formed into a colloidal solution, and the radiation shielding fabric was fabricated by curing after coating the solution on one side or both sides of the fabric. The thicknesses of the shielding sheets prepared with bismuth oxide were 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, and 1.0 mm. An experimental method was used to measure the absorbed dose and irradiation dose by using the lead equivalent test method of X-ray protection goods presented by Korean Industrial Standards; the resultant shielding rate was then calculated. From the results of this study, the X-ray shielding effect of the shielding sheet with 0.1 mm thickness was about 55.37% against 50 keV X-ray, and the X-ray shielding effect in the case of 1.0 mm thickness showed shielding characteristics of about 99.36% against 50 keV X-ray. In conclusion, it is considered that nanosized-bismuth radiation shielding fiber developed in this research will contribute to reducing the effects of primary X-ray and secondary X-ray such as when using a scattering beam at a low level exposure.

Analysis of Cholangitis Rates with Extended Perioperative Antibiotics and Adjuvant Corticosteroids in Biliary Atresia

  • Goh, Lynette;Phua, Kong Boo;Low, Yee;Chiang, Li Wei;Yong, Chen;Chiou, Fang Kuan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.24 no.4
    • /
    • pp.366-376
    • /
    • 2021
  • Purpose: There is no consensus regarding adjuvant therapies following Kasai portoenterostomy (KP) for biliary atresia (BA). This study aimed to analyze the effect of extended perioperative intravenous antibiotics (PI-Abx) and adjuvant corticosteroid on cholangitis and jaundice clearance rates in the 3 years post-KP in children with BA. Methods: Data of patients who underwent KP between 1999-2018 at a single center were retrospectively analyzed. Group A (1999-2010) received PI-Abx for 5 days, Group B (2010-2012) received PI-Abx for 5 days plus low-dose prednisolone (2 mg/kg), and Group C (2012-2017) received PI-Abx for 14 days plus high-dose prednisolone (5 mg/kg). Results: Fifty-four patients were included with groups A, B, and C comprising 25, 9, and 20 patients, respectively. The number of episodes of cholangitis was 1.0, 1.6, and 1.3 per patient (p=NS) within the first year and 1.8, 2.3, and 1.7 (p=NS) over 3 years in Groups A, B, and C, respectively. The jaundice clearance rate at 6 months was 52%, 78%, and 50% (p=NS), and the 3-year native liver survival (NLS) rate was 76%, 100%, and 80% (p=NS) in Groups A, B, and C, respectively. A near-significant association was observed between the incidence of cholangitis within the first year and decompensated liver cirrhosis/death at 3 years post KP (p=0.09). Persistence of jaundice at 6 months was significantly associated with decompensated cirrhosis/death at 3 years (p<0.001). Conclusion: The extended duration of PI-Abx and adjuvant corticosteroids was not associated with improved rates of cholangitis, jaundice clearance, or NLS in patients with BA.

50-300 keV X-ray Transmission Ratios for Lead, Steel and Concrete

  • Tae Hwan Kim;Kum Bae Kim;Geun Beom Kim;Dong Wook Kim;Sang Rok Kim;Sang Hyoun Choi
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.164-171
    • /
    • 2022
  • The number of facilities using radiation generators increases and related regulations are strengthened, the establishment of a shielding management and evaluation technology has become important. The characteristics of the radiation generator used in previous report differ from those of currently available high-frequency radiation generators. This study aimed to manufacture lead, iron, and concrete shielding materials for the re-verification of half-value layers, tenth-value layers, and attenuation curve. For a comparison of attenuation ratio, iron, lead, and concrete shields were manufactured in this study. The initial dose was measured without shielding materials, and doses measured under different types and thicknesses of shielding material were compared with the initial dose to calculate the transmission rate on 50-300 kVp X-ray. All the three shielding materials showed a tendency to require greater shielding thickness for higher energy. The attenuation graph showed an exponential shape as the thickness decreased and a straight line as the thickness increased. The difference between the measurement results and the previous study, except in extrapolated parts, may be due to the differences in the radiation generation characteristics between the generators used in the two studies. The attenuated graph measured in this study better reflects the characteristics of current radiation generators, which would be more effective for shield designing.

Improvement of PM10 Forecasting Performance using Membership Function and DNN (멤버십 함수와 DNN을 이용한 PM10 예보 성능의 향상)

  • Yu, Suk Hyun;Jeon, Young Tae;Kwon, Hee Yong
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.9
    • /
    • pp.1069-1079
    • /
    • 2019
  • In this study, we developed a $PM_{10}$ forecasting model using DNN and Membership Function, and improved the forecasting performance. The model predicts the $PM_{10}$ concentrations of the next 3 days in the Seoul area by using the weather and air quality observation data and forecast data. The best model(RM14)'s accuracy (82%, 76%, 69%) and false alarm rate(FAR:14%,33%,44%) are good. Probability of detection (POD: 79%, 50%, 53%), however, are not good performance. These are due to the lack of training data for high concentration $PM_{10}$ compared to low concentration. In addition, the model dose not reflect seasonal factors closely related to the generation of high concentration $PM_{10}$. To improve this, we propose Julian date membership function as inputs of the $PM_{10}$ forecasting model. The function express a given date in 12 factors to reflect seasonal characteristics closely related to high concentration $PM_{10}$. As a result, the accuracy (79%, 70%, 66%) and FAR (24%, 48%, 46%) are slightly reduced in performance, but the POD (79%, 75%, 71%) are up to 25% improved compared with those of the RM14 model. Hence, this shows that the proposed Julian forecast model is effective for high concentration $PM_{10}$ forecasts.