• Title/Summary/Keyword: High Design

Search Result 28,766, Processing Time 0.051 seconds

An Analysis on Layout Patterns and their Trends in the Prizewinners of Elementary.Middle.High School Design Competitions (초.중.고등학교 현상설계 당선안에 나타난 배치 계획 요소 및 경향 분석)

  • Lee, Jung-Woo;Kim, Hyung-Jin
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.19 no.3
    • /
    • pp.3-12
    • /
    • 2012
  • Owing to generalization of design competitions since 1990s, various design methods was tried in elementary middle high school design competitions. Therefore, to analyze design characteristics of elementary middle high school is very meaningful. In this context, this study is the most important purpose for analyzing layout plans and their trends in prizewinners of elementary middle high school design competitions and for furnishing basic datum for next school design. The result of this study is following : (1) The layout patterns of school buildings are classified into 12 types. (2) Entrance design is divided into 6 types(structure, column and wall, open, half structure, general, and mixed type). (3) Square design is grouped into 7 types. (4) Pedestrian mall is sorted out 6 types(straight lineal, curve, curve and square, straight lineal and curve, and straight lineal and curve and square type). (5) Entrance types of vehicle and pedestrian are classified into 4 types(parallel, ㅡ separation, ㄱ separation, and opposite separation type) Analysis shows that the best applying for layout patterns of school buildings is ㄷ type and ㅌ type, for entrance design is structure type, for square design is ${\square}$ type and ${\bigcirc}$ type, for pedestrian mall is straight lineal and square type, and for entrance types of vehicle and pedestrian is parallel type.

Overview of Performance-Based Seismic Design of Building Structures in China

  • Li, Guo-Qiang;Xu, Yan-Bin;Sun, Fei-Fei
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.3
    • /
    • pp.169-179
    • /
    • 2012
  • The development history, the current situation and the future of the performance-based seismic design of building structures in China are presented in this paper. Firstly, the evolution of performance-based seismic design of building structures specified in the Chinese codes for seismic design of buildings of the edition 1974, 1978, 1989, 2001 and 2010 are introduced and compared. Secondly, in two parts, this paper details the provisions of performance-based seismic design in different Chinese codes. The first part is about the "Code for Seismic Design of Buildings" (GB50011) (edition 1989, 2001 and 2010) and "Technical Specification for Concrete Structures of Tall Building", which presents the concepts and methods of performance-based seismic design adopted in Chinese codes; The second part is about "Management Provisions for Seismic Design of Outof-codes High-rise Building Structures" and "Guidelines for Seismic Design of Out-of-codes High-rise Building Structures", which concludes the performance-based seismic design requirements for high-rise building structures over the relevant codes in China. Finally, according to those mentioned above, this paper pointed out the imperfections of current performance-based seismic design in China and proposed the possible direction for further improvement.

Design Considerations of Resonant Network and Transformer Magnetics for High Frequency LLC Resonant Converter

  • Park, Hwa-Pyeong;Ryu, Younggon;Han, Ki Jin;Jung, Jee-Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.383-392
    • /
    • 2016
  • This paper proposes the design considerations of resonant network and transformer magnetics for 500 kHz high switching frequency LLC resonant converter. The high power density can be effectively achieved by adopting high switching frequency which allows small size passive components in the converter. The design methodology of magnetizing inductance is derived for zero voltage switching (ZVS) condition, and the design methodology of the transformer and output capacitance is derived to achieve high power density at high operating frequency. Moreover, the structure of transformer is analyzed to obtain the proper inductance value for high switching operation. To verify the proposed design methodology, simulation and experimental results will be presented including temperature of passive and active components, and power conversion efficiency to evaluate dominant power loss. In addition, the validity of magnetics design will be evaluated with operating waveforms of the prototype converter.

Behaviour and design of Grade 10.9 high-strength bolts under combined actions

  • Li, Dongxu;Uy, Brian;Wang, Jia;Song, Yuchen
    • Steel and Composite Structures
    • /
    • v.35 no.3
    • /
    • pp.327-341
    • /
    • 2020
  • The use of high-strength steel and concrete in the construction industry has been gaining increasing attention over the past few decades. With it comes the need to utilise high-strength structural bolts to ensure the design load to be transferred safely through joint regions, where the space is limited due to the reduced structural dimensions. However, research on the behaviour of high-strength structural bolts under various loading combinations is still insufficient. Most of the current design specifications concerning high-strength structural bolts were established based on a very limited set of experimental results. Moreover, as experimental programs normally include limited design parameters for investigation, finite element analysis has become one of the effective methods to assist the understanding of the behaviour of structural components. An accurate and simple full-range stress-strain model for high-strength structural bolts under different loading combinations was therefore developed, where the effects of bolt fracture was included. The ultimate strength capacities of various structural bolts obtained from the present experimental program were compared with the existing design provisions. Furthermore, design recommendations concerning the pure shear and tension, as well as combined shear and tension resistance of Grade 10.9 high-strength structural bolts were provided.

Ultra high precision Dual stage system Using Air bearing and VCM for Nano level Scanning (VCM을 이용한 나노 정밀도 스캐닝 용 초정밀 이중 스테이지)

  • Kim Ki-Hyun;Gweon Dae-Gab;Choi Young-Man;Kim Dong-Min;Nam Byoung-Uk;Lee Suk-Won;Lee Moon-Gu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.5 s.170
    • /
    • pp.103-112
    • /
    • 2005
  • This paper presents one-axis high precision scanning system and illustrates the design of modified $X-Y-{\theta}$ stage as a tracker using VCM and commercialized air bearings for it. The scanning system for 100nm resolution is composed of the 3-axis stage and one axis long stroke linear motor stage as a follower. In this study a previous proposed and presented structure of VCM for the fine stage is modified. The tracker has 3 DOF($X-Y-{\theta}$ motions by four VCM actuators which are located on the same plane. So 4 actuating forces are suggested and designed to create least pitch and roll motions. This article will show about the design especially about optimal design. The design focus of this fine stage is to have high acceleration to accomplish high throughput. The optimal design of maximizing acceleration is performed in restrained size. The most sensitive constraint of this optimal design is heat dissipation of coil. There are 5 design variables. Because the relationship between design variables and system parameters are quite complicated, it is very difficult to set design variables manually. Due to it, computer based optimal design procedure using MATLAB is used. Then, this paper also describes the procedures of selecting design variables for the optimal design and a mathematical formulation of the optimization problem. Based on the solution of the optimization problem, the final design of the stage is also presented. The results can be verified by MAXWELL. The designed stage has the acceleration of about 5 $m/s^{2}$ with 40kg total mass including wafer chuck and interferometer mirror. And the temperature of coil is increased $50^{\circ}C$. In addition, the tracker is controlled by high precision controller system with HP interferometer for it and linear scaler for the follower. At that time, the scanning system has high precision resolution about 5nm and scanning resolution about 40nm in 25mm/s constant speed

Design Characteristics Analysis for Very High Temperature Reactor Components (VHTR 초고온기기 설계특성 분석)

  • Kim, Yong Wan;Kim, Eung Seon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.85-92
    • /
    • 2016
  • The operating temperature of VHTR components is much higher than that of conventional PWR due to high core outlet temperature of VHTR. Material requirements and technical issues of VHTR reactor components which are mainly dominated by high temperature service condition were discussed. The codification effort for high temperature material and design methodology are explained. The design class for VHTR components are classified as class A or B according to the recent ASME high temperature reactor design code. A separation of thermal boundary and pressure boundary is used for VHTR components as an elevated design solution. Key design characteristics for reactor pressure vessel, control rod, reactor internals, graphite reflector, circulator and intermediate heat exchanger were analysed. Thermo-mechanical analysis of the process heat exchanger, which was manufactured for test, is presented as an analysis example.

Structural Optimization of High-rise Buildings using High-strength Steels (고강도강재의 효율적 사용을 위한 초고층건물의 최적설계기법)

  • Seo, Ji-Hyun;Kwon, Bong-Keun;Kim, Sang-Bum;Park, Hyo-Seon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.3
    • /
    • pp.277-287
    • /
    • 2009
  • Recently, the high-strength steel of 400~600MPa tensile strength is producing in the country. Use of high-strength steel member in the design of high-rise buildings is expected to increase the efficiency of structural design in the aspect of structure material weight and cost, however it has been used only a narrow extent. No efficient design method to use high-strength steel in the design of high-rise buildings has been developed. Therefore, in this study structural cost optimization technique that can minimize the structural material cost of high-rise buildings using high-strength steels is developed. The efficiency of the technique is evaluated by comparing the experience-based design for 6 high-rise building examples. As a result, the proposed techniques can save 7~21% of structural material cost compared with experienced-based design. And also, the rough guideline for effective use of high-strength steels in the structural design of high-rise buildings is introduced on the basis of results.

An Analysis of the Sustainability of High-rise Apartment Unit Design Elements (초고층아파트 단위주공간의 지속가능성 평가요소 분석)

  • Lee, Eun Jung
    • KIEAE Journal
    • /
    • v.6 no.3
    • /
    • pp.57-66
    • /
    • 2006
  • The issue of sustainability has been prevailed not only in building industry but also all other industries. It has been raised that the concept of sustainability should take into account for the design of multi-use high-rise apartments. In this study, the present situation and trends of the multi-use high-rise apartment construction have been reviewed. The definition of sustainable design of high-rise apartment has been clarified so as to perceive the related design elements through the literature survey. Finally this study has derived the sustainable design elements of high-rise apartment unit plans through the comparative analysis of sustainable design guidelines, environmentally friendly building accreditation systems and literature survey in and abroad.

A Study on the Design Characteristics based on the Distinction Strategies of Korean Main City Department Stores - through the analysis of case studies from 1990 to present - (우리나라 주요 도심 백화점의 차별화 전략에 따른 디자인 특성에 관한 연구 - 1990년대 이후 현재까지 사례분석을 중심으로 -)

  • 김현관;최상헌
    • Korean Institute of Interior Design Journal
    • /
    • no.39
    • /
    • pp.92-99
    • /
    • 2003
  • Big 3 Korean department stores - Lotte, Hyundai, and Shinsegae have pursued a differentiation strategy in order to survive the era of big-bang. This study has proposed to present a frame work with which we can recognize the character of design, which is pertinent to a differentiation strategy. The results of study are as follow ; 1) Lotte department store reveals the 3 strategies - location, composition and specialization strategy and the character of design has traditional, high class and neutral disposition. 2) Hyundai department store reveals high class strategy and the character of design has high class and modern disposition. 3) Shinsegae department store reveals high class and specialization strategies and the character of design has high class, tradition and modem disposition.

The Optimum Mix Design of 40MPa, 60MPa High Fluidity Concrete using Neural Network Model (신경망 모델을 이용한 40MPa, 60MPa 고유동 콘크리트의 최적배합설계)

  • Cho, Sung-Won;Cho, Sung-Eun;Kim, Young-Su
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.223-224
    • /
    • 2021
  • Recently, the demand for high fluidity concrete has been increased due to skyscrapers. However, it has its own limits. First of all, high fluidity concrete has large variation and through trial & error it costs lots of money and time. Neural network model has repetitive learning process which can solve the problem while training the data. Therefore, the purpose of this study is to predict optimum mix design of 40MPa, 60MPa high fluidity concrete by using neural network model and verifying compressive strength by applying real data. As a result, comparing collective data and predicted compressive strength data using MATLAB, 40MPa mix design error rate was 1.2%~1.6% and 60MPa mix design error rate was 2%~3%. Overall 40MPa mix design error rate was less than 60MPa mix design error rate.

  • PDF