• 제목/요약/키워드: High Contact

검색결과 4,007건 처리시간 0.031초

고속전철용 레일-휠 접촉에서 응력분포에 관한 유한요소해석 (Finite Element Analysis on the Stress Distributions in Rail-Wheel Contacts of High Speed Trains)

  • 김청균;김기환
    • Tribology and Lubricants
    • /
    • 제13권3호
    • /
    • pp.93-101
    • /
    • 1997
  • The numerical results on the stress distributions of rail-wheel contact problems are presented for three models in a high-speed rail system. These models which have straight and tapered (1:40 and 1:20) contact geometries between the wheelset and rail are analyzed using the finite element approach. From the simulation results we found that the tapered geometry (1:20) of railwheel contact base line showed very stable contact stress distributions for a whole contact position between the wheel and rail in a curved rail section. The FEM computed results may present an optimized slope geometry of rail-wheel contact in a high-speed railway system.

수동필터를 이용한 고속전철 이선현상에 의한 전원외란 저감 (Reduction of Power Disturbance by Contact Loss Phenomenon of a High Speed Electric Train Using Passive Filters)

  • 장진영;진강환;강정남;박동규;김윤호
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.206-211
    • /
    • 2010
  • Since high-speed train is a dynamic load in which electric power is externally supplied, contact loss between the catenary and pantograph occurs. This phenomena including vibrations generates frequently irregular arcs, which, in turn causes EMI. Thus it is very important to develop the approach to reduce arc phenomenon by contact loss, as speed of electric railway vehicle increases. In case of an electric railway vehicle using electrical power, compared with diesel rolling stock, Power Line Disturbance(PLD) such as harmonics, transient voltage and current, Electromagnetic Interference(EMI), and dummy signal injection etc usually occur. In this study, the dynamic characteristics of a contact wire and a pantograph suppling electrical power to high-speed train are investigated with an electrical response point. To implement power line disturbance induced by contact loss phenomenon for high speed train operation, a hardware simulator which considers contact loss between contact wire and pantograph as well as contact wire deviation is developed. It is confirmed by the experiments that contact loss effect is largely dependent on voltage conditions when the contact loss occurs. Also, a passive filter is designed to reduce power disturbance and the designed system is verified by experiment.

Behaviors of turn-to-turn contact resistance (Rc) of various REBCO CC tapes according to applied contact pressure

  • Jeong, Chanhun;Shin, Hyung-Seop
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권3호
    • /
    • pp.15-20
    • /
    • 2018
  • No-insulation (NI) pancake magnets are fabricated using Rare earth-Barium-Copper Oxide (REBCO) coated conductor (CC) tapes, which enabled a very compact magnet in the aspects of high critical current density ($J_c$) and high mechanical strength by removing insulation and allowing thinner stabilizer. They have also advantages such as self-quench protection. Therefore, it does not need quench detection and protection that can be very challenging in a high critical temperature ($T_c$) superconducting magnet technology. Recently, it was reported that the NI REBCO CC magnets have some drawbacks of long charging time and high field ramp loss which will be a concern in the operation of cryocooled magnets. These issues are related to the turn-to-turn contact resistivity and can be released by managing it. This is also closely related to the activity of reducing the contact joint resistance in the case of CC joints for long length CC fabrication. Therefore, in this study, the turn-to-turn contact resistance ($R_c$) at the CC contact part of differently stabilized CC tapes was measured. The behaviors of $R_c$ at CC contact parts according to the applied contact pressure were investigated. The range of $R_c$ measured for CC tapes adopted will provide fundamental data for design and fabrication of the CC NI coils.

전원외란 시뮬레이터를 이용한 고속전철 이선현상과도 특성 연구 (Transient Characteristic Study on Contact Loss of High Speed Electric Railway Using a Power Line Disturbance Simulator)

  • 김재문;김양수
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.427-431
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI(Electromagnetic Interference), dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

고속 주축베어링의 볼 접촉각 변동을 고려한 주축 설계공차 (Design Tolerance of High Speed Spindle considering the Variation of Ball Contact Angle in the Angular Contact Ball Bearings)

  • 이찬홍
    • 한국생산제조학회지
    • /
    • 제19권5호
    • /
    • pp.609-615
    • /
    • 2010
  • Angular contact ball bearings in a high speed spindles are under the extreme conditions, such as high temperature, big centrifugal force and thrust cutting forces. So, the assembly contacts between spindle shaft and inner ring bearings, bearing housing and outer ring of bearings are occasionally unstable at high speed revolution. Furthermore, the ball contact angle of a bearing, which influence stiffness and lifetime of bearings, are changed according to loads and rotational speed. To analyze internal forces of a bearing under high speed revolution, the ball contact are calculated using nonlinear equations in consideration of rotational speed, thrust loads and raceway form. Diameter increase of inner and outer ring by influence factors, such as internal forces to inner and outer ring, centrifugal force and temperature of inner and outer rings are calculated to establish stable state in bearing assembly in high speed spindle. Finally, contribution ratio of influence factor to assembly design tolerance of inner and outer rings are shown and the stable assembly design tolerance are proposed.

A Study on the Measurement of Contact Force of Pantograph on High Speed Train

  • Seo, Sung-Il;Cho, Yong-Hyun;Mok, Jin-Yong;Park, Choon-Soo;Kim, Ki-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1374-1378
    • /
    • 2005
  • Appropriate upward force is crucial for the pantograph on high speed train to collect current from the catenery system without separation. However, at high speed, large aerodynamic lifting force is generated by the contact plate and the arms of pantograph, which may cause wear of the contact wire. In this study, to confirm the interface performance of the pantograph on Korea High Speed Train, a method to measure the contact force of the pantograph was proposed and the related measurement system was developed. The forces acting on the pantograph were clarified and a procedure to calculate the aerodynamic lifting force was proposed. A special device was invented and applied to measure the lifting force. Measured contact forces were displayed by the developed system and evaluated according to the criteria. Countermeasures were also taken to reduce the contact force based on the results.

  • PDF

드롭퍼 위치를 고려한 고속전철 전력선과 급전기의 접촉 분리 해석 (Analysis of Contact and Separation between the Catenary and the Pantograph of a High-speed Electrical Train Considering the Dropper Positions)

  • 이기수
    • 한국소음진동공학회논문집
    • /
    • 제17권5호
    • /
    • pp.427-436
    • /
    • 2007
  • The catenary of a high-speed electrical train is modeled by the finite elements with the upper suspension wire, lower contact wire, and droppers, and the dynamic contact between the catenary and the pantograph is numerically analyzed by solving the whole equations of motion of the pantograph and the catenary system subjected to the contact condition. For the stability of the numerical solution, with the cubic spline interpolation of the catenary displacement, the velocity and acceleration constraints as well as the displacement constraint are imposed on the contact point. Through the various numerical examples, it is shown that the dropper positions as well as the static deflection are crucial to determine the contact and separation of the pantograph of a high-speed train.

반복 제어를 이용한 접촉력 제어 (Repetitive Control of Contact Force)

  • 전도영;정일용
    • 한국정밀공학회지
    • /
    • 제13권4호
    • /
    • pp.122-128
    • /
    • 1996
  • In high speed and high precision assembly systems such as a surface mounting device and robotend effector, the contact force control is required. As the operation repeats, the repetitive control is applied to reduce the periodic contact force errors. Since high order unmodelled dynamics are easily excited in contact force control, a Q filter was introduced and its robust stability was analyzed. Simulation and Experimental results show the effectiveness of the algorithm.

  • PDF

전원외란 시뮬레이터를 이용한 고속전철 이선현상 모의 실험 (The Simulation Implementation on contact loss of high speed electric railway using a Power Line Disturbance simulator)

  • 김재문;김양수;장진영;안정준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2152_2153
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI, dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

  • PDF

고속전철 주행에 따른 이선현상 모의 시뮬레이터 개발 (Development of simulator by induced contact loss phenomenon for high-speed train operation)

  • 김재문;김양수;김철수;장진영;김윤호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.499-503
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI, dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

  • PDF