• Title/Summary/Keyword: HgS

Search Result 1,001, Processing Time 0.029 seconds

A Carbazole-Attached NO2S2-Macrocycle Exhibiting Hg2+ and Cu2+ Selectivity

  • Lee, Seul-Gi;Kang, Eun-Ju;Lee, Shim Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.5
    • /
    • pp.1429-1434
    • /
    • 2013
  • A synthesis and cation-induced fluorescent behavior of the carbazole-attached $NO_2S_2$-macrocycle (L) is described and structurally characterized by single crystal X-ray analysis. The photoluminescence spectrum of L in 80% $CH_3CN/CH_2Cl_2$ displays a peak maximum at 431 nm (blue emission). In the metal-induced fluorometric experiment, L showed a drastic chelation-enhanced fluorescence quenching (CHEQ) effect only with $Hg^{2+}$ and $Cu^{2+}$. In ESI-mass study, a 1:1 stoichiometry for complexation of L with $Hg^{2+}$ was confirmed, suggesting the unique sensing behavior of the proposed ligand L due to the selective complexation affinity for $Hg^{2+}$. The observed results indicate that L is a promising turn-off type fluoroionophore for $Hg^{2+}$ and $Cu^{2+}$ detections. Additionally, the $Ag^+$ complex of the precursor macrocycle was prepared and its solid structure was crystallographically characterized.

Negative Pressure Cavitation Acetone-Pentane Fractional Precipitation for the Purification of Paclitaxel from Taxus chinensis (Taxus chinensis로부터 파클리탁셀 정제를 위한 음압 캐비테이션 아세톤-펜테인 분별침전)

  • Min, Hye-Su;Kim, Jin-Hyun
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.544-549
    • /
    • 2022
  • This study presents the negative pressure cavitation acetone-pentane fractional precipitation to dramatically improve the precipitation efficiency of paclitaxel from Taxus chinensis. When paclitaxel was precipitated under a negative pressure of -200 mmHg, most paclitaxel (>99.9%) could be recovered in a short precipitation time (5 min). The precipitation rate constant increased by 1.512~5.073 times (at -50 mmHg to -200 mmHg) compared to the control. The activation energy decreased by -3,737~-6,536 J/mol due to negative pressure, which increased the precipitation rate. With the introduction of negative pressure, the precipitate size decreased by 5.3 times, and the diffusion coefficient of paclitaxel increased by 7.0 times.

HgTe/Cdte superlattices grown on CdZnTe(211)B by MBE

  • Kang, T.W.;Jeong, C.S.;Leem, J.H.;Ryu, Y.S.;Hyun, J.K.;Jeon, H.C.;Lee, H.Y.;Han, M.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.34-42
    • /
    • 1997
  • Hg-Te-CdTe superlattices have received much interests over the last several years as a potential material for its applications for detecting devices and optoelectronics. We have grown the HgTe-CdTe superlattice using MBE. in our lab. We have carried out DCRC spectroscopy after growth of HgTe-CdTe superlattice with varying the superlattice periods and controlling the barrier thickness and we have that the presence of the main peak and the satellite peaks. We obtained 20 arcsec of FWHM over 100 periods of superlattice. We also note that high peak intensity shows the high quality of the sample and each layer of superlattice has abrupt interfaces. The angular separation between the main peak(m=0) and the first satellite peak(m=$\pm$1) is increased when the barrier layer thickness in superlatice layers are decreased. The separation between the first setellite peak(m=$\pm$1) and the second satellite peak(m$\pm$2) is increased similarly. The number of the satellite peak is a qualitative measure of the interfacial abruptness of the superlattice.

  • PDF

Study on the Relationship between Vascular Perfusion and Interface Pressure under the Ischial Tuberosity in the Sitting Posture (앉은 자세에서 좌골결절의 접촉압력과 혈류량과의 관계에 대한 연구)

  • Heo H.;Bae T.S.;Lee S.M.;Kim S.K.;Kim K.H.;Mun M.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.645-646
    • /
    • 2006
  • Pressure-induced decubitus is a serious disease among the elderly people. Interface pressure occluding vascular perfusion is known to be a cause of decubitus. Therefore, it is essential to quantify the relationship between vascular perfusion and interface pressure among the elderly people. Nine elderly normal people ($57.8{\pm}5.6\;years,\;63.3{\pm}7.0kg,\;1.68{\pm}0.05m$) were participated. Pressure was applied on the ischial tuberosity in the sitting posture from 0mmHg to 135mmHg as capillary vascular perfusion was recorded. The average interface pressure to occlude vascular perfusion under the ischial tuberosity is 120mmHg. Vascular perfusion values at the capillary occlusion is often lower than 60% of the vascular perfusion at 15mmHg. Higher sampling number is required to have more accurate results.

  • PDF

Genetic Vadation and Systematics of the Sticklebacks (Pisces, Gasterosteidae) in Korea (한국산 큰가시고기와 어류의 지리적 변이 및 계통적 유연관계)

  • 양서영;민미숙
    • The Korean Journal of Zoology
    • /
    • v.33 no.4
    • /
    • pp.499-508
    • /
    • 1990
  • Surveys of elecirophoretic variations in isozymes and proteins encoded by 25 persumtive loci were conducted to estimate the degree of genic variation and to assess species recognition for three species of the Family Gasterosteidae (Pisces) in Korea. The average degree of genic variation of Gasterosteus aculeatus was HD = 0.086, HG = 0.084, and P =36% and it was similar to Pungitius sinensis (HD = 0.080, HG = 0.091, P = 29%). But P.kaibarae was less variable than these species (HD = 0.034; HG = 0.034, P = 13%). The average genetic similarities among the populations in each species of Gasterosteus aculeatus pungitius sinensis and P. kaibarae were S = 0.963, S = 0.953 and S = 0.800 respectively.Yongchon and Kyongiu populations of P. kaibarae were genetically remote from the rest of the conspecific populations (S = 0.690). Chae (1988) also observed morphological differences between them. The value of genetic similariiy coefficients of S = 0.606 between P. sinensis and P. kaibarae is low enough to consider as specific level of genetic difference, but moderate rate of hybridization (44%) between them at a synpatric area of Kangnung indicates that isolating mechanism is incomplete. Therefore it is concluded that P. sinensis and P. kaffarae are semispecitic status. Intergeneric genetic similarities between the genus Gasrerosteus and Pungitius were S = 0.052 and this value is the lowest estimate up to date in freshwater fishes.

  • PDF

Some Statistical Considerations for the Estimation of Urinary Mercury Excretion in Normal Individuals (정상인의 요중 수은배설량 추정의 통계학적 연구)

  • Park, Hee-Sook;Chung, Kyou-Chull
    • Journal of Preventive Medicine and Public Health
    • /
    • v.13 no.1
    • /
    • pp.27-34
    • /
    • 1980
  • Purpose of this study is to find out proper means of estimating the urinary mercury excretion in the normal individuals. Whole void volume was collected every 2 hours beginning from 6 o'clock in the morning until 6 o'clock next morning. Mercury excretion in each urine specimen was measured by NIOSH recommended dithizone colorimetric method (Method No.: P & CAM 145). Urinary concentration of mercury was adjusted by two means: specific gravity of 1.024 and a gram of creatinine excretion per liter of urine comparing the data with the unadjusted ones. Mercury excretion in 24-hour urine specimen was calculated by adding the amounts measured with the hourly collected specimens of each individual. Statistical analysis of the urinary mercury excretion revealed the following results: 1. Frequency distribution curve of mercury excreted in urine of hourly specimens was best fitted to power function expressed in the form of $y=ax^b$. Adjustment of the urinary mercury concentration by creatinine excretion was shown to be superior($y=1674x^{-1.52},\;r^2=0.95$) over nonadjustment($y=2702x^{-1.57},\;r^2=0.92$) and adjustment by specific gravity of 1.024($y=4535x^{-1.66},\;r^2=0.93$). 2. Both log-transformed mercury excretion in hourly voided specimens and mercury excretion itself in 24 hour specimens showed the normal distributions. 3. The frequency distribution of mercury adjusting the urinary concentration of mercury by creatinine excretion was best fitted to a theoretical normal distribution with the sample means and standard deviation than those unadjusted or adjusted with specific gravity of 1.024. 4. Average urinary mercury excretions in 24-hour urine specimen in an individual were as follows: a) Unadjusted mercury excretion mean and standard deviation : $$18.6{\pm}13.68{\mu}gHg/l$$. median : $$16.0\;{\mu}gHg/l$$. range : $$0.0-55.10\;{\mu}gHg/l$$. b) Adjusted with specific gravity mean : $$20.7{\pm}11.76\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ median : $$20.7\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ range : $$0.0-52.9\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ c) Adjusted with creatinine excretion mean and standard deviation : $$10.5{\pm}6.98\;{\mu}gHg/g$$ creatinine/l median : $$9.4\;{\mu}gHg/g$$ creatinine/l range : $$0.0-26.7\;{\mu}gHg/g$$ creatinine/l 5. No statistically significant differences were found between means calculated from 24-hour urine specimens and those from hourly specimens transformed into logarithmic values. (P<0.05).

  • PDF

Experimental Studies on Extracorporeal Circulation by Sarns Heart-Lung Machine with Total Prime of Hartman's Solution (Sarns 심폐기의 혈희석 체외순환에 관한 실험적 연구)

  • 김근호
    • Journal of Chest Surgery
    • /
    • v.8 no.2
    • /
    • pp.135-142
    • /
    • 1975
  • Total body perfusion using Sarns Heart-Lung-Machine, five head pump motor system with Travenol disposable bubble oxygenator was attempted in the dogs by the hemodilution method with total prime of buffered Hartman`s solution under moderate hypothermia. The first of all, the functions of Sarns Heart-Lung-Machine and effects of the hemodilution perfusion by buffered Hartman`s solution was studied. At the same time the changes of pressure of artery and vein, gas contents of the blood, and influence on the blood pictures were observed before, during, and after perfusion in 1-2 days. Hemodilution rates were the ranges of 85.0ml/kg to 97.3ml/kg and perfusion flow rates were maintained with the average 80. 5ml/kg/min [the ranges of 73.3ml/kg/min to 92.8ml/kg/min]. Hypothermia was employed between $35^{\circ}C$ and $31^{\circ} of the esophageal temperature. The total body perfusion was continued for 50-60 minutes. In the total cardiopulmonary bypass, atriotomy, ventriculotomy, and atrioventriculotomy were performed respectively. Arterial pressure was ranged approximately between 50 mmHg and 140 mmHg, but generally, it was maintained over 75 mmHg. Venous pressure was measured between 3.8 cm$H_2O$ and 16.0 cm$H_2O$. Optimum oxygenation could be achieved when oxygen flow into the oxygenator was maintained approximately at 5. 5L/min. In this way, the $pO_2$, $pCO_2$, and oxygen saturation were measured before, during, and afterperfusion in 1-2 days. The $pCO_2$ ranged approximately between 26.0 mmHg and 38.5 mmHg, but generally, it was maintained in the average 30.9-32.5mmHg. The $pO_2$ was ranged between 73.0mmHg and 332.2 mmHg, but it was maintained in the average 103.0-219.0 mmHg. Oxygen saturation was measured over 95. 0% during and after extracorporeal circulation respectively. Erythrocyte count, hemoglobin, hematocrit, and leucocyte count were decreased to 49.2%, 49.0%, 49.4%, and 21. 1% of the preoperative value during extracorporeal circulation respectively and these reductions were not recovered until 1-2 days after perfusion. These. resulted from relatively high degree of hemodilution rate and operative bleeding during these experimental studies. The platelets count was also decreased about to 71% during perfusion, on the contrary, it was increased progressively after perfusion and in 1-21 days after perfusion, the value was returned to preoperative contro1 level. Three dogs were all recovered after extracorporeal circulation.

  • PDF

Heavy Metal Analysis of Inhabitants from City of the Seoul, Korea (서울지역 거주 성인 모발의 유해 중금속 함량 분석)

  • Im, Eun-Jin;Ha, Byung-Jo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.35 no.1
    • /
    • pp.27-32
    • /
    • 2009
  • Human hair is an excretory system for trace metals and thus metal content in human hair can reflect the body status. The investigation of trace elements in human hair has been correlated with the diagnosis of various diseases as well as the monitoring of deficiency statues in nutrition. Many chronic diseases may be related to mineral status, some may be related to toxic mineral. Hair samples were collected from 120 inhabitants of the city of Seoul, Korea. In this study the concentrations of 10 elements (Hg, Pb, Cd, Al, As, U, Bi, Sb, Ba, Be) in hair were determined by inductively coupled plasma mass spectroscopy (ICP-MS). The conclusions showed that people in Seoul, Korea were affected by some kinds of toxic minerals. The Hg concentrations of male are higher than those of female and reference range. The mean concentration of Sb was higher in the female than male and reference range. In age distribution, the mean concentration of Hg was in 40's are higher than 20's and 30's and reference range. The concentrations of Al were the highest in the 20's. After analyzing, we concluded that a compounded treatment should be conducted, which considers the variety of factors related to detoxification.

A study on the characteristics of double insulating layer (HgCdTe MIS의 이중 절연막 특성에 관한 연구)

  • 정진원
    • Electrical & Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.463-469
    • /
    • 1996
  • The double insulating layer consisting of anodic oxide and ZnS was formed for HgCdTe metal insulator semiconductor(MIS) structure. ZnS was evaporated on the anodic oxide grown in H$_{2}$O$_{2}$ electrolyte. Recently, this insulating mechanism for HgCdTe MIS has been deeply studied for improving HgCdTe surface passivation. It was found through TEM observation that an interface layer is formed between ZnS and anodic oxide layers for the first time in the study of this area. EDS analysis of chemical compositions using by electron beam of 20.angs. in diameter and XPS depth composition profile indicated strongly that the new interface is composed of ZnO. Also TEM high resolution image showed that the structure of oxide layer has been changed from the amorphous state to the microsrystalline structure of 100.angs. in diameter after the evaporation of ZnS. The double insulating layer with the resistivity of 10$^{10}$ .ohm.cm was estimated to be proper insulating layer of HgCdTe MIS device. The optical reflectance of about 7% in the region of 5.mu.m showed anti-reflection effect of the insulating layer. The measured C-V curve showed the large shoft of flat band voltage due to the high density of fixed oxide charges about 1.2*10$^{12}$ /cm$^{2}$. The oxygen vacancies and possible cationic state of Zn in the anodic oxide layer are estimated to cause this high density of fixed oxide charges.

  • PDF

Fabrication and Its Characteristics of HgCdTe Infrared Detector (HgCdTe를 이용한 Infrared Detector의 제조와 특성)

  • 김재묵;서상희;이희철;한석룡
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.227-237
    • /
    • 1998
  • HgCdTe Is the most versatile material for the developing infrared devices. Not like III-V compound semiconductors or silicon-based photo-detecting materials, HgCdTe has unique characteristics such as adjustable bandgap, very high electron mobility, and large difference between electron and hole mobilities. Many research groups have been interested in this material since early 70's, but mainly due to its thermodynamic difficulties for preparing materials, no single growth technique is appreciated as a standard growth technique in this research field. Solid state recrystallization(SSR), travelling heater method(THM), and Bridgman growth are major techniques used to grow bulk HgCdTe material. Materials with high quality and purity can be grown using these bulk growth techniques, however, due to the large separation between solidus and liquidus line on the phase diagram, it is very difficult to grow large materials with minimun defects. Various epitaxial growth techniques were adopted to get large area HgCdTe and among them liquid phase epitaxy(LPE), metal organic chemical vapor deposition(MOCVD), and molecular beam epitaxy(MBE) are most frequently used techniques. There are also various types of photo-detectors utilizing HgCdTe materials, and photovoltaic and photoconductive devices are most interested types of detectors up to these days. For the larger may detectors, photovoltaic devices have some advantages over power-requiring photoconductive devices. In this paper we reported the main results on the HgCdTe growing and characterization including LPE and MOCVD, device fabrication and its characteristics such as single element and linear array($8{\times}1$ PC, $128{\times}1$ PV and 4120{\times}1$ PC). Also we included the results of the dewar manufacturing, assembling, and optical and environmental test of the detectors.

  • PDF