• Title/Summary/Keyword: Hg

Search Result 3,633, Processing Time 0.034 seconds

Temperature-dependent Structural and Magnetic Properties of Diamagnetic $HgI_2$

  • Park, C.I.;Jin, Zhenlan;Hwang, I.H.;Yeo, S.M.;Han, S.W.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.291.1-291.1
    • /
    • 2013
  • We examined the temperature-dependent structural and magnetic properties of HgI2 in the temperature range of 300~400 K. HgI2 is a diamagnetic material and can be used for X-ray or γ-ray detectors. DCmagnetization measurements on HgI2 showed that there is a small but distinguishable change in its diamagnetic properties near 375 K. The magnetic property change is not expected because Hg and I are known as nonmagnetic elements. X-ray diffraction (XRD) measurements revealed a structural transition in the temperature of 350~400 K. Temperature-dependent x-ray absorption fine structure (XAFS) demonstrated that the chemical valence states of both Hg and I did not changed in the temperature range of 300~400 K. However, XAFS revealed that the bond-length disorder was slightly increased in the temperature range, particularly, near Hg atoms. The structural changes of HgI2 are likely related to its diamagnetic property change. We will discuss the relation between the diamagnetic properties and local structural properties of HgI2 in detail.

  • PDF

Mercury Ions Mediated Phosphorus Containing Carbon Dots as Fluorescent Probe for Biothiols Screening

  • Du, Han;Xu, Hu;Zhao, Yun;Li, Dan;Wang, Yuhong
    • Nano
    • /
    • v.13 no.10
    • /
    • pp.1850116.1-1850116.14
    • /
    • 2018
  • In this study, we report the mercury ions ($Hg^{2+}$) mediated phosphorus-containing carbon dots (PCDs) as a selective "off-on" fluorescence probe for glutathione (GSH), cysteine (Cys) and homocysteine (Hcys). PCDs obtained by hydrothermal reaction are sensitive to $Hg^{2+}$ ions and its fluorescence can be significantly quenched owing to the electron transfer from the lowest unoccupied molecular orbital (LUMO) of PCDs to $Hg^{2+}$. Interestingly, the weak fluorescence of $Hg^{2+}$-mediated PCDs could be gradually recovered with the addition of GSH, Cys and Hcys. This can be attributed to the formation of $Hg^{2+}-S$ complex due to the super affinity of $Hg^{2+}$-sulfydryl bond. The formation of $Hg^{2+}-S$ complex extremely reduces the oxidation ability of $Hg^{2+}$ that inhibits the electron transfer from LUMO of PCDs to $Hg^{2+}$ and re-opens the native electron transition from LUMO to the highest occupied molecular orbital (HOMO) of PCDs. Thus, the green fluorescence of PCDs is switched on. Furthermore, the present $Hg^{2+}$-mediated PCDs assay exhibits a high selectivity for GSH, Cys and Hcy and has been successfully used to detect the total biothiols content in human urine samples.

Hg2+-Selective Chemosensor Derived from 8-Hydroxyquinoline Having Benzothiazole Function in Aqueous Environment

  • Youk, Jin-Soo;Kim, Young-Hee;Kim, Eun-Jin;Youn, Na-Jin;Chang, Suk-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.869-872
    • /
    • 2004
  • Newly synthesized 8-hydroxyquinoline based benzothiazole derivative 2 showed a distinctive $Hg^{2+}$-selectivity over other transition metal ions in aqueous solution. The fluorescence emission at 455 nm of 2 was completely quenched upon interaction with $Hg^{2+}$ ions in dioxane-$H_2O$ system (9 : 1, v/v). The selectivity was decreased in the order of $Hg^{2+}\;>>\;Cu^{2+}\;>\;Cd^{2+}\;>\;Pb^{2+}\;{\thickapprox}\;Zn^{2+}\;{\thickapprox}\;Ni^{2+},\;and\;Hg^{2+}$ concentration dependent fluorescence quenching profile was observed in the presence of common interfering metal ions as background. The fluorescence behavior of 2 suggests that the prepared compound could be used as a fluorescent signaling subunit for the construction of new $Hg^{2+}$-sensitive ON-OFF type supramolecular switching systems.

Photo current Characteristic of CdTe/HgTe/CdTe Structured Nanoparticles (CdTe/HgTe/CdTe구조 나노입자의 광전류 특성)

  • Kim, Dong-Won;Cho, Kyoung-Ah;Kim, Hyun-Suk;Park, Byoung-Jun;Kim, Sang-Sig
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.139-140
    • /
    • 2005
  • The photocurrent characteristics of CdTe/HgTe/CdTe structured nanoparticles are studied. CdTe/HgTe/CdTe multilayer structured nanoparticles were synthesized by colloidal method. CdTe/HgTe/CdTe multilayer structured nanoparticles were characterized by x-ray diffraction, high-resolution transmission electron microscopy(HRTEM), absorbance and photoluminescence(PL). PL spectrum of CdTe/HgTe/CdTe multilayer structured nanoparticles exhibits a strong exciton bond in the near infrared range. The I-V curves and photoresponses revealed that CdTe/HgTe/CdTe multilayer structured nanoparticles are very prospective materials for the photodetectors.

  • PDF

Computer Simulation of the Effect of Pressurized/Depressurized Distillation Process on the Reduction of Separation Energy of Ethanol from Alcohol Fermented Broth (가압/감압 증류 공정이 발효 알콜의 분리 에너지 절감 효과에 미치는 영향에 관한 전산 모사)

  • 허병기;배천순;김휘동
    • Journal of Energy Engineering
    • /
    • v.2 no.1
    • /
    • pp.123-132
    • /
    • 1993
  • This work is focussed on the reduction of ethanol separation energy from alcohol fermented broth and categorized into the development of a computer program for the design of the pressurized/depressurized distillation process which has been regarded as one of the energy-reducing models for the conventional distillation process, the optimization of operating conditions of distillation towers by means of the developed program, and the evaluation of the total annual energy cost of pressurized/depressurized distillation columns compared with that of the conventional single distillation columns. The operating pressures are, in case of pressurized/depressurized distillation, 3103/760 mmHg, 3103/450 mmHg, 3103/160 mmHg, and in case of conventional distillation, 760 mmHg. The optimum reflex rations which the sum of the annual energy cost and the annual fixed cost for each process becomes minimum are 3.7475/2.9111 for the operating pressures of 3103/760 mmHg, 3.814/2.9712 for 3103/450 mmHg, 3.0783/2.2400 for 3103/150 mmHg, and 3.8544 for the atmospheric operating pressure. And the annual energy cost of pressurized/depressurized distillation process for the above-mentioned operating pressures is distributed between 42% and 47% of that of conventional distillation process.

  • PDF

Variation of Vital Sign according to Time in Full Immersion of Hot and Cool Bath (온.냉욕 전신침수욕시 기간에 따른 vital sign의 변화)

  • Yi, Seung-Ju
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.3
    • /
    • pp.35-49
    • /
    • 1996
  • This study was conducted to see variation of vital sign of hot and cool bath according to time, a questionnair survey and measurement was carried out for 32 students(sophomore) of department of physical therapy Andong Junior College on the 27th of June, 1995. The result were as follows: The average systolic blood pressure(SBP) of stability for 32 college students who were measured was 105.3mmHg, the average diastolic blood pressure(DBP) was 67.3mmHg, the average pulse frequency(PF) was 70.7(frequency/min), the average respiratory frequency (RF) was 15.6 (frequency/min), and the body temperature(BT) was $36.6^{\circ}C$. As time went on, SBP for 32 students who were measured in hot bath according to stability, 3 min, 6 min, 9 min, and 12 min was decreased(105.15 mmHg, 104.69mmHg, 104.24 mmHg, 103.03 mmHg, and 96.69 mmHg)(P=0.3006). SBP was decreased in cool bath, too(105.15 mmHg, 103.33 mmHg, 103.33 mmHg, and 100.91 mmHg), but it at 12 min was a little higher(l03.09 mmHg)(P=0.7566). As time went on, DBP according to stability, 3 min, 6 min, 9 min, and 12 minutes was decreased in hot bath(66.82 mmHg, 65.45 mmHg, 64.54 mmHg, 63.03 mmHg, and 59.39 mmHg)(P=0.0906). It was similar in cool bath(66.82 mmHg, 67.87 mmHg, 68.48 mmHg, 67.87 mmHg, and 68.78)(P=0.9654). As time went on, PF was significantly increased in hot bath(70.42 times, 86.96 times, 93.57 times, 99.30 times, and 101.78 times)(P=0.0001). It was a little increased in cool bath, too (70.42 times, 70.85 times, 71.63 times, 71.06 times, and 71.45 times)(P=0.9803). As time went on, RF was significantly increased in hot bath(15.75 times, 19.09 times, 22.09 times, 24.94 times, and 26.48 times)(P=0.0001). I t in cool bath of stability, 3 min, and 6 min was a little increased(15.75 times, 19.30 times, 19.39 times), but it in 9 min(18.67 times), and 12 min(18.09 times) was a little decreased(P=0.0176). As time went on, BT was significantly increased in hot bath($36.63^{\circ}C,\;37.45^{\circ}C,\;37.81^{\circ}C,\;38.12^{\circ}C,\;38.33^{\circ}C$)(P=0.0001). It was a little increased in cool bath of stability and 3 min($36.63^{\circ}C,\;37.40^{\circ}C$), but others are similar($37.33^{\circ}C,\;37.37^{\circ}C$, and $37.36^{\circ}C$)(P=0.0001). It was revealed by this study, SBP and DBP according to time in hot and cool bath were decreased. PF, RF, and BT in hot bath were higher, RF and BT in cool bath were higher too. but PF was similar.

  • PDF

Effect of Mercuric Chloride (In Vitro) on the Function of Human Polylnorphonuclear Leukocytes(PMNs) (수은이 시험관내 사람 다형핵백혈구의 기능에 미치는 영향)

  • 한형미;윤은이;김순한;김옥연;김효정;선우연
    • Biomolecules & Therapeutics
    • /
    • v.1 no.2
    • /
    • pp.131-136
    • /
    • 1993
  • In the present study, the effect of $HgCl_2$on the function of human peripheral polymorphonuclear leukocytes(PMNs) was examined. PMNs were isolated from human peripheral blood with density centrifugation in Ficoll-Paque. The cells were then incubated with $0.5{\sim}5{\mu}M\;HgCl_2$and glass adherence, chemotactic activity and erythrocyte-antibody rosette forming activity were measured. $HgCl_2$ decreased the function of PMNs in all three aspects tested. $HgCl_2$significantly diminished glass adherence(40.5 {\mu}M: 92{\pm}12%$ (percentage of control, $mean{\pm}$ S.D.); 41 {\mu}M: 46{\pm}11%,$ P<0.01; $3{\mu}M: 35{\pm}7%,$P<0.01;$5{\mu}M:49{\pm}10%,$ P<0.01). Similarly, significant differences were observed in chemotactic activity after $HgCl_2$treatment compared with control (control: $0.95{\pm}0.14mm; 0.5 {\mu}M: 0.91{\pm}0.11 mm; 1 {\mu}M: 0.77{\pm}0.16mm, P<0.05; 3{\mu}M: 0.61{\pm} 0.06mm, P<0.01; 5{\mu}M: 0.15{\pm}0.03 mm, P<0.01).$ Also, 4HgCl_2$decreased the percentage of rosette-forming PMNs, indicating diminished phagocytic activity of PMNs upon $HgCl_2$ exposure compared with control (control: $58{\pm}4%; 1{\mu}M: 53{\pm}4%, p<0.05; 3{\mu}M: 49{\pm}3%, P<0.01; 5{\mu}M: 46{\pm}3%, P<0.01).$ Cell viability was not antered after $HgCl_2$treatment (483{\pm}5%$ viability in control PMNs versus $81{\pm}8%$ viability in $5{\mu}M$ Hg-treated PMNs), suggesting that the impaired PMN function after $HgCl_2$treatment was not due to nonspecific cytotoxicity induced by $HgCl_2$. $HgCl_2$-induced decrease in the function of PMNs may have some implications in depressed host susceptibilityupon bacterial challenge after mercury exposure.

  • PDF

Hg(II) ion- Selective Electrodes with Neutral Carriers of Macrocycles (거대고리 중성 운반체를 갖는 Hg(II)이온 선택성 전극)

  • 정오진
    • Journal of Environmental Science International
    • /
    • v.5 no.2
    • /
    • pp.211-220
    • /
    • 1996
  • New thin-and diselena-crown ethers containing two suffer and selenium donor atoms have been prepared. And then, mercury ($Hg^{2+}$) ion-selective electrodes with PVC-plasticizer (STPB) based on some macrocycles as neutral carriers were also made. The electrochemical selectivities for various ions, and the effects for macrocycles, matrix of membranes, ratio of plasticizer to macrowcles, concentration and pH of test solution were investigated on the $Hg^{2+}$ ion-selective electrodes. The 1, 10-diselena-18-crown-6-PVC-STPB (sodium tetraphenylborate) exhibited good linear responses of ${28.2}\pm{0.6}$ decade-1 for $Hg^{2+}$ ion in the conientration ranges of $10^{-2}~10^{-6}$ M $Hg^{2+}$ ion. This electrode exhibited comparatively good selectivities for $Hg^{2+}$ ion in comparison with alkali and alkaline earth metal ions, some heavy metal ions and rare earth metal ion in the range of pH 2.5~6.0. In addition, this electrode was applied as a sensor in the titration of $Hg^{2+}$ ion with $1^-$ ion in water.

  • PDF

The change in blood pressure and factors affecting the change in blood pressure for Korean children: A six-year follow-up study (국민학생의 6년간 혈압의 변화양상과 혈압변화와 관련된 요인 분석)

  • Suh, Il;Lee, Soon-Young;Nam, Chung-Mo;Kim, Il-Soon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.1 s.41
    • /
    • pp.96-109
    • /
    • 1993
  • For the purposes of analyzing the distribution and the change in blood pressure according to age and determining the factors affecting the change in blood pressure, a follow-up study had been conducted for 6 years from 1986 to 1991 for 430 primary school children aged 6 years old in 1986 in Kangwha County, Korea. The mean blood pressure increased according to age. Specifically mean systolic blood pressure increased from 97.3 mmHg for male and 96.4mmHg for female (at 6 years of age) to 108.8mmHg fur male and 112.1mmHg for female (at 11 years of age). Mean diastolic blood pressure increased from 60.0mmHg for male and 61.8mmHg for female (at 6 years of age) to 72.9mmHg for male and 73.8mmHg for female (at 11 years of age). The average annual increase in blood pressure was 2.3mmHg (in systolic blood pressure) and 2.6 mmHg (in diastolic blood pressure) for male : and 3.1mmHg (in systolic blood pressure) and 2.4mmHg (in diastolic blood pressure) for female, respectively. To determine the factors affecting the change in blood pressure, the stepwise regression analysis was conducted. Children were divided into the three groups(low, middle, and upper) according to the level of systolic and diastolic blood pressure at the age of 6, and the regression analysis was performed in each group. For the change in systolic blood pressure, the changes in weight and skinfold thickness or initial skinfold thickness fer male, and the change in weight for female were selected as significant factors for children in middle and upper group. For the change of blood pressure in diastolic blood pressure, no variables was significant.

  • PDF

Fabrication and Test of a $HgI_2$ Gamma Ray Detector (감마선 검출용 $HgI_2$ 소자 제작 및 특성 평가)

  • Choi, Myung-Jin;Lee, Hong-Kyu;Kang, Young-Il;Lim, Ho-Jin;Choi, Seung-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.1-6
    • /
    • 1991
  • The $HgI_2$ single crystal which can be used for the ${\gamma}-ray$ detector at room temperature was grown by Temperature Oscillation Method. The low temperature photoluminescence, specific resistivity and trap concentration of $HgI_2$ single crystal were investigated. Three main luminescence bands were observed at 2.30eV, 2.20eV and 2.00eV at 20K, related to the excitons, I-vacancies and impurities, respectively. The specific resistivity and trap concentration of $HgI_2$ single crystal were $10^{11}{\Omega}\;cm\;and\;1.8{\times}10^{14}/cm^3$ at room temperature, respectively. Also the radiation detecting system was deviced by $HgI_2$ ${\gamma}-ray$ detector, one chip microprocessor, LCD module and personal computer. The prepared $HgI_2$ ${\gamma}-ray$ detector showed a good linearity of ${\gamma}-radiation$ dose for standard ${\gamma}-ray$.

  • PDF