• Title/Summary/Keyword: Hero Shaper ProFile

Search Result 7, Processing Time 0.029 seconds

Comparison of shaping ability between various hybrid instrumentation methods with ProTaper (ProTaper를 사용한 다양한 hybrid instrumentation methods의 근관성형 효율 비교)

  • Hong, Eun-Sook;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.11-19
    • /
    • 2006
  • The purpose of this study was to compare and evaluate the shaping abilities of various hybrid instrumentation method using constant tapered file systems with $ProTaper\^{(R)}$ S1 and the difference between experts and inexperienced clinicians in use of NiTi file. Three hybrid methods used in this study were composed of $ProTaper\^{(R)}\;S1\;and\;K-Flexofile\^{(R)}\;(group S),\;ProTaper\^{(R)}\;S1\;and\;HeroShaper\^{(R)}\;(group\;H),\;and\;ProTaper\^{(R)}\;S1\;and\;ProFile\^{(R)}\;(group\;P)$respectively. The $ProTaper\^{(R)}$-alone method (group C) was introduced as a control group. After canal preparation, the lapse of time was recorded. The images of pre- and post-operative canal were scanned and superimposed. Amounts of instrumented canal widths and centering ratio were measured at apical 1, 2 and 3 mm levels and statistical analysis was performed In this study. both of the group C and S took more time to prepare canals than other groups, Inexperienced operators required more time for the entire preparation with the groups C and H than the experienced (p<0.05). And the centering ratio of group P were preferable to $ProTaper\^{(R)}$-alone method or the hybrid technique using stainless steel files. As such, within experienced operators, group H also showed better results in addition to the group P. Under these condition, the hybrid methods of each the $ProFile^{(R)}$ system and $HeroShaper^{(R)}$ with ProTaper are recommendable comparative to $ProTaper\^{(R)}$-alone method. According to the results, the hybrid instrumentation method is a more appropriate method of canal preparation than single file system for narrow or curved canals.

Comparison of screw-in effect of three NiTi file systems used by undergraduates (학생들이 사용한 세 종류 NiTi file systems의 screw-in effect 비교)

  • Oh, Seung-Hei;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.477-484
    • /
    • 2006
  • The purposes of this study were to compare the apical terminus width of simulated curved root canal prepared with three NiTi file systems used by undergraduates for evaluation the effects of flute angle and pitch or radial land on reducing screw-in effect and to determine more safe NiTi file system for inexperienced operators. Fifty inexperienced undergraduate students prepared 150 simulated curved root canals in resin blocks with three NiTi file systems ; ProFile$^{(R)}$, Hero Shaper$^{(R)}$, K3$^{TM}$. The electric motor set at a speed of 300 rpm and torque of 30 in a 16 : 1 reduction handpiece was used. The simulated root canal was prepared to ISO #25 sizes with each file system. The scanned images of pre- and post-instrumented canal of resin block were superimposed. To evaluate the screw-in effect of three NiTi file systems, apical terminus width of root canal was measured from superimposed images and statistical analysis was performed. There were significant differences in three NiTi flle systems. ProFile$^{(R)}$ had significantly smaller width than Hero Shaper$^{(R)}$ and K3$^{TM}$"" (P < 0.05), but no significant difference was observed between K3$^{TM}$ and Hero Shaper$^{(R)}$. Under the condition of this study, active file system (Hero SHaper$^{(R)}$, K3$^{TM}$) with variable pitch and helical angle had more screw-in effect than passive file system (ProFile$^{(R)}$) with constant pitch and helical angle. It seems that the radial lands play more important role in reducing screw-in effect.

COMPARISON OF SHAPING ABILITY OF ROTARY Ni-Ti FILE SYSTEMS USED BY UNDERGRADUATES (학생들이 사용한 엔진 구동형 Ni-Ti file systems의 근관 성형 효율 비교)

  • Kang, Mun-Seong;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • The purpose of this study was to compare the shaping ability of three Ni-Ti file systems used by dental students or the experts and consequently to aid in choosing a proper systems for educational courses of dental students and beginners. Fifty students and ten dentists who have clinical experience over two years prepared 180 simulated root canals in resin blocks with three Ni-Ti systems; $ProFile^{(R)}\;(PF),\;HeroShaper^{(R)}\;(HS),\;K3^{TM}\;(K3)$. After preparation, the Ni-Ti files were evaluated for distortion and canal preparation time was recorded. The images of pre- and post-instrumented canals were scanned and superimposed. Amounts of increased canal widths, deviation, and centering ratio were calculated at apical 1, 3 and 5 mm levels and statistical analysis was performed The results were as follows : 1. HS showed the shortest preparation time and instrumented canal width in K3 was significantly larger than other groups (P<0.05). 2. At 1 and 3mm levels, all groups had outward deviation. In student group, at the 1mm level, PF had the least deviation (P<0.05). 3. In the centering ratio, the PF had the best centering ability compared to the others at 5mm level. At 1 and 3mm levels, HS and PF had better abilities than K3. Student group had better ratio than the expert at 3mm level with PF (P<0.05). Based on the results, it is surmised that the $ProFile^{(R)}$ is the safest and most ideal instrument for students and beginners.

THE EFFECT OF DIFFERENT FLUTE DESIGN AND TORQUE-CONTROLLED MOTOR ON THE SHAPING ABILITY OF SIMULATED RESIN ROOT CANALS (엔진의 토크 조절 능력과 니켈-티타늄 파일의 삭제 성향이 근관 성형에 미치는 영향)

  • Roh, Hyoung-Mee;Huh, Bock;Kim, Hyeon-Cheol;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.486-492
    • /
    • 2005
  • The purpose of this study was to compare the shaping ability of the two different Ni-Ti file systems and the two different engine systems in simulated canals. A total of four groups of each 10 were tested. Each group was instrumented with HeroShaper and Endo-Mate2 (Croup HE), HeroShaper and Tecnika (Croup HT), ProFile and Endo-Mate2 (Group PE), and ProFile and Tecnika (Croup PT). Canal preparation time was recorded. The images of pre- and post- instrumented root canals were scanned and superimposed. The amounts of increased width and centering ratio were measured and calculated at apical 1, 3 and 5mm levels. These data were statistically analyzed with one-way ANOVA and Duncan's multiple range test The results of this study were as fellows ; 1. Canal preparation time of HT group was the shortest (p<0.05). 2. The amount of increased canal width in HE group was significantly larger than PT group at apical 1mm level (p<0.05) At apical 3mm level, PT group was significantly smaller than other groups (p<0.05). At apical 5mm level, PE group was significantly larger than PT group (p<0.05). 3. The amount of centering ratio in HE group was significantly larger than other groups (p<0.05). At apical 5mm level, HT group was significantly larger than PE group and PT group (p<0.05). Under the condition of this study, torque-controlled endodontic motor is safer than no torque controlled motor, especially when the active file is used.

COMPARATIVE STUDY ON MORPHOLOGY OF CROSS-SECTION AND CYCLIC FATIGUE TEST WITH DIFFERENT ROTARY NITI FILES AND HANDLING METHODS (수종의 NiTi 전동 파일 단면 형태 비교 및 pecking motion의 사용방법이 피로 파절에 미치는 영향)

  • Kim, Jae-Gwan;Kum, Kee-Yeon;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.96-102
    • /
    • 2006
  • There are various factors affecting the fracture of NiTi rotary files. This study was performed to evaluate the effect of cross sectional area, pecking motion and pecking distance on the cyclic fatigue fracture of different NiTi files. Five different NiTi $files-Profile^{(R)}$ (Maillefer, Ballaigue, Switzerland), $ProTaper^{TM}$(Maillefer, Ballaigue, Switzerland), $K3^{(R)}$ (SybronEndo. Orange, CA) , Hero $642^{(R)}$ (Micro-mega, Besancon, France), Hero $Shaper^{(R)}$ (Micro-mega, Besancon, France)-were used. Each file was embedded in temporary resin, sectioned horizontally and observed with scanning electron microscope. The ratio of cross-sectional area to the circumscribed circle was calculated. Special device was fabricated to simulate the cyclic fatigue fracture of NiTi file in the curved canal,. On this device, NiTi files were rotated (300rpm) with different pecking distances (3 mm or 6 mm) and with different motions (static motion or dynamic pecking motion) . Time until fracture occurs was measured. The results demonstrated that cross-sectional area didn't have any effect on the time of file fracture. Among the files, $Profile^{(R)}$ took the longest time to be fractured. Between the pecking motions, dynamic motion took the longer time to be fractured than static motion. There was no significant difference between the pecking distances with dynamic motion, however with static motion, the longer time was taken at 3mm distance. In this study, we could suggest that dynamic pecking motion would lengthen the time for NiTi file to be fractured from cyclic fatigue.

Comparison of shaping ability using various Nickel-Titanium rotary files and hybrid technique (다양한 전동 니켈 티타늄 파일과 혼합사용법에 의한 근관 성형 효율 비교)

  • Kim, Jung-Won;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.530-541
    • /
    • 2007
  • Currently, various Nickel-Titanium rotary files are used in endodontic treatment, but there is no one perfect system that can be applied to any clinical situation. Therefore, the combined uses of various file systems which can emphasize the advantages of each system are introduced as hybrid instrumentation. The ProTaper system is efficient in body shaping and apical pre-enlargement but is reported to have more possibility of transportation and produce more aberrations and deformation in more or less severe curved canals. Recently, new ProTaper system(ProTaper Universal) with different configuration and cross-sectional design to overcome the week points of ProTaper have been marketed. The purpose of this study was to compare and evaluate the shaping abilities of ProTaper, ProTaper Universal system, and two hybrid methods using S-series of ProTaper Universal and Hero Shaper or ProFile. The time lapses for instrumentation were measured and the used files were inspected for distortion. The pre- and post-instrumented root canals were scanned and superimposed to evaluate the aberrations and reduction of root canal curvature and change of radius of canal curvature. The increased canal width and apical centering ratio were calculated at 1, 2, 3, 4 and 5 mm levels from apical foramen. Under the conditions of this study, the ProTaper Universal seems to have better shaping ability than ProTaper in terms of instrumented width and instrumentation time. It may be suggested that the ProTaper Universal system is efficient as much as hybrid instrumentation using ProTaper and other constant-tapered NiTi file systems in highly experienced operators.

EFFECT OF CROSS-SECTIONAL AREA OF 6 NICKEL-TITANIUM ROTARY INSTRUMENTS ON THE FATIGUE FRACTURE UNDER CYCLIC FLEXURAL STRESS: A FRACTOGRAPHIC ANALYSIS (반복 굽힘 스트레스 하에서 전동식 니켈-티타늄 파일의 단면적의 크기가 피로파절에 미치는 영향 : 파절역학 분석)

  • Hwang, Soo-Youn;Oh, So-Ram;Lee, Yoon;Lim, Sang-Min;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.424-429
    • /
    • 2009
  • This study aimed to assess the influence of different cross-sectional area on the cyclic fatigue fracture of Ni-Ti rotary files using a fatigue tester incorporating cyclical axial movement. Six brands of Ni-Ti rotary files (ISO 30 size with. 04 taper) of 10 each were tested: Alpha system (KOMET), HeroShaper (MicroMega), K3 (SybronEndo), Mtwo (VDW), NRT (Mani), and ProFile (Dentsply). A fatigue-tester (Denbotix) was designed to allow cyclic tension and compressive stress on the tip of the instrument. Each file was mounted on a torque controlled motor (Aseptico) using a 1:20 reduction contra-angle and was rotated at 300 rpm with a continuous, 6 mm axial oscillating motion inside an artificial steel canal. The canal had a $60^{\circ}$ angle and a 5 mm radius of curvature. Instrument fracture was visually detected and the time until fracture was recorded by a digital stop watch. The data were analyzed statistically. Fractographic analysis of all fractured surfaces was performed to determine the fracture modes using a scanning electron microscope. Cross-sectional area at 3 mm from the tip of 3 unused Ni-Ti instruments for each group was calculated using Image-Pro Plus (Imagej 1.34n, NIH). Results showed that NRT and ProFile had significantly longer time to fracture compared to the other groups (p < .05). The cross-sectional area was not significantly associated with fatigue resistance. Fractographycally, all fractured surfaces demonstrated a combination of ductile and brittle fracture. In conclusion, there was no significant relationship between fatigue resistance and the cross-sectional area of Ni-Ti instruments under experimental conditions.