• 제목/요약/키워드: Henderson-Hasselbalch equation

검색결과 3건 처리시간 0.021초

담배 중 pH와 Nicotine 함량에 의한 Free nicotine 측정 (Calculation of Free Nicotine by Determination of pH and Nicotine in Tobacco)

  • 이정민;장기철;황건중;김용하;이문수
    • 한국연초학회지
    • /
    • 제27권2호
    • /
    • pp.219-225
    • /
    • 2005
  • Characterizing nicotine delivery from tobacco products is important in the understanding of their addictive potential. Most previous studies report total nicotine and have not differentiated between nicotine in its protonated or free-base form. The amount of free nicotine calculated by determining pH and nicotine contents. The pH and nicotine contents in smokeless tobacco product, tobacco products and tobacco leaves were analyzed by Health Canada-Official Method T-310 and CORESTA Recommended Method $N^{\circ}62$. The content of free nicotine was calculated according to the Henderson-Hasselbalch equation and the value of $\alpha_{fb}$(the fraction of nicotine that is in the free base form) by using a pKa value of 8.02 for nicotine. The percentage of free nicotine then was calculated by dividing the free nicotine content by total nicotine content. The pH value and percentage of free nicotine ranged from 5.01 to 5.45 and $0.10\%\;to\;0.27\%$ in cut tobacco and 5.10 to 7.10 and $0.12\%\;to\;10.73\%$ in tobacco leaves, respectively.

H$^+$ 선택성 막 전극을 이용한 바이오센서의 감응 특성 (Characteristic Responses of Biosensor Based on $H^+$-Selective Membrance Electrode)

  • 김기묘;박성배;황명석;허문회;안문규
    • 약학회지
    • /
    • 제40권6호
    • /
    • pp.625-631
    • /
    • 1996
  • The $H^+$-selective membrane consists of tridodecylamine, 2-nitrophenyl octyl ether and a little amount of additive in carboxylated PVC matrix, where penicillinase(Pcase ) and glutaraldehyde may be covalently attached to the matrix. When the $H^+$-selective electrode was used as a detector of biosensor, calibration curve calculated from Nernst equation was not linear. So we investigated the characteristic responses of the $H^+$-selective electrode to the product H+ from hydrolysis of penicillin-G(Pc-G) and plotted calibration curve correlating potential to concentration of Pc-G linearly. The optimal concentration of buffer solution was theoretically calculated and was also experimented. We tried to explain the linear curve of potential to concentration of Pc-G by using Henderson-Hasselbach equation. This method is more effective in calibration curve plotting than any other previous methods. The results obtained may help in further developing pH electrodes with improved analytical preformance.

  • PDF

임상용 MR에서 pH 측정을 위한 동물 실험용 $^1H-^{31}P$ RF 코일 개발 (Development of $^1H-^{31}P$ Animal RF Coil for pH Measurement Using a Clinical MR Scanner)

  • 김은주;김대홍;이상우;허단;이영한;서진석
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권1호
    • /
    • pp.52-58
    • /
    • 2014
  • 목적: 임상용 MRI에서 마우스 종양의 pH 측정을 위한 $^1H-^{31}P$ RF 코일 시스템을 개발하고 팬텀을 이용하여 pH 값의 정확도를 시험하고자 한다. 대상과 방법: 마우스 종양 연구를 위한 표면형 $^1H$$^{31}P$ radio frequency (RF) 코일을 개발하였다. 두 코일을 서로 수직이 되도록 설치하여 두 코일간의 상호인덕턴스를 0으로 하였다. 다양한 pH 값을 가진 팬텀으로부터 $^{31}P$ MR 스펙트럼을 얻어 Henderson-Hasselbalch equation을 이용하여 pH를 구하였다. $^{31}P$ 스펙트럼으로부터 얻은 pH값은 pH meter를 사용하여 직접 구한 pH값과 비교한다. 결과: $^1H-^{31}P$ RF 코일 상호간 coil coupling (S12)은 각각 -73.0, -62.3 dB로 충분히 분리 되었다. 균일한 팬텀으로부터 얻은 $^1H$ 영상의 signal-to-noise ratio (SNR)는 약 300 이상이며, in vivo 고해상도 마우스 영상을 얻을 수 있었다. $^1H$ 신호가 분리된 $^{31}P$ MR 스펙트럼으로부터 얻은 pH값은 pH meter로 직접 측정하여 얻은 값과 약 97% 상관관계를 가졌다. 결론: 본 연구에서 개발한 임상 MRI 장비용 $^1H-^{31}P$ RF 코일 시스템으로부터 정확한 pH를 구할 수 있었다. 본 코일 시스템은 31P 이외의 다른 핵 MRS 혹은 MRI에 적용 가능할 것으로 기대된다.