• 제목/요약/키워드: Hemoglobin A1c

Search Result 459, Processing Time 0.025 seconds

Relationship between the Self-Reported Oral Health Status and Hemoglobin A1c Level among Diabetic Patients (일부 당뇨병 환자에서 당화혈색소 수치와 주관적 구강건강상태와의 연관성)

  • Choi, Jun-Seon
    • Korean Journal of Health Education and Promotion
    • /
    • v.25 no.1
    • /
    • pp.55-69
    • /
    • 2008
  • Objective: This study was to investigate the relationship between hemoglobin A1c level and self-reported oral health status. Methods: The subjects of this study were 150 diabetic patients (60 male patients and 90 female patients) who went to the internal and family medicine departments of clinic. This study used the questionnaire and NYCOCARD$\square$ READERII to quantify hemoglobin A1c. Results: The proportion of well controlled diabetes subjects was 31.3%. When hemoglobin A1c levels became higher, subjects perceived that there were more decay teeth, bleeding, swollen gums, mobility teeth, and oral disease symptoms. In comparison with the well glycemic control group, poor glycemic control group perceived that the overall oral health status was worse, and had more bleeding teeth, swollen gums and mobility teeth. Conclusion: These results show that hemoglobin A1c level is related to the self-reported oral health status. Therefore, dental professionals should emphasize more the necessity of maintaining the hemoglobin A1c of normal range and monitoring it periodically, and the practice of thorough oral hygiene care in order to promote diabetic patients' oral health.

Optimization of Enzyme Digestion Conditions for Quantification of Glycated Hemoglobin Using Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry

  • Jeong, Ji-Seon
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.52-56
    • /
    • 2014
  • Glycated hemoglobin (HbA1c) is used as an index of mean glycemia over prolonged periods. This study describes an optimization of enzyme digestion conditions for quantification of non-glycated hemoglobin (HbA0) and HbA1c as diagnostic markers of diabetes mellitus. Both HbA0 and HbA1c were quantitatively determined followed by enzyme digestion using isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) with synthesized N-terminal hexapeptides as standards and synthesized isotope labeled hexapeptides as internal standards. Prior to quantification, each peptide was additionally quantified by amino acid composition analysis using ID-LC-MS/MS via acid hydrolysis. Each parameter was considered strictly as a means to improve digestion efficiency and repeatability. Digestion of hemoglobin was optimized when using 100 mM ammonium acetate (pH 4.2) and a Glu-C-to-HbA1c ratio of 1:50 at $37^{\circ}C$ for 20 h. Quantification was satisfactorily reproducible with a 2.6% relative standard deviation. These conditions were recommended for a primary reference method of HbA1c quantification and for the certification of HbA1c reference material.

Factors Associated with Hemoglobin A1c among Patient Aged 40 years over with Diabetes Mellitus: 2012 Korea Health and Nutrition Examination Survey (40대 이상 당뇨환자의 당화혈색소 조절 상태에 영향을 미치는 요인: 2012 국민건강영양조사결과를 바탕으로)

  • Ji, Eun Joo
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.22 no.4
    • /
    • pp.433-441
    • /
    • 2015
  • Purposes: This study was done to identify factors associated with uncontrolled hemoglobin A1c among patient with diabetes mellitus. Method: The sample was 412 Koreans with diagnosed diabetes aged 40 years or older who participated in the Fifth Korea Health and Nutrition Examination survey, which was a nationwide, cross-sectional survey. Data was analyzed using logistic regression. Uncontrolled hemoglobin A1c rate was 55%. Results: There was a difference between controlled and uncontrolled group in hemoglobin A1c as follows: duration of diabetes, BMI(Body Mass Index), hypertriglyceridemia, vitamin D, sleep duration. After adjusting for confounding factor, longer duration of diabetes (>7 years vs. ${\leq}7$)(Adjusted OR=2.277, 95% CI [1.277-4.060]), presence of hypertriglyceridemia (Adjusted OR=4.019, 95% CI [1.871-8.634]), lower vitamin D level (<20ng/mL vs. ${\geq}20$)(Adjusted OR=2.487, 95% CI[1.411-4.381]), longer sleep duration (6-8 hours vs >8 hours)(Adjusted OR=6.831, 95% CI [1.877-24.855]) were significantly associated with increased odds of uncontrolled hemoglobin A1c. Conclusions: Results show that duration of diabetes, hypertriglyceridemia, vitamin D and sleep duration are significantly related to hemoglobin A1c. Therefore, considering these factors it would be helpful to develop strategies to improve blood glucose control in patients with diabetes.

Optimization of Microwave-Assisted Method for Accelerated Glycated Hemoglobin Quantification from Amino Acids to Proteins

  • Tran, Thi Thanh Huong;Jeong, Ji-Seon
    • Mass Spectrometry Letters
    • /
    • v.8 no.3
    • /
    • pp.53-58
    • /
    • 2017
  • Glycated hemoglobin ($HbA_{1c}$) has been commonly used to screen and diagnose for patients with diabetes mellitus. Here the accelerated procedure of microwave-assisted sample treatment from acid hydrolysis to enzyme digestion followed by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) was optimized and applied to measure $HbA_{1c}$ in an effort to speed up analysis time. First, two signature peptides of $HbA_{1c}$ and hemoglobin $A_0$ were certified with amino acid analysis by setting optimized acid hydrolysis conditions to $150^{\circ}C$, 1.5 h and $10{\mu}M$ sample concentration in 8 M hydrochloric acid. Consequently, the accurate certified peptides above were used as calibration standards to implement the proteolytic procedure with endoproteinase Glu-C at $37^{\circ}C$, 700 W for 6 h. Compared to the traditional method, the microwave heating not only shortened dramatically sample preparation time, but also afforded comparable recovery yields. The optimized protocol and analytical conditions in this study are suitable for a primary reference method of $HbA_{1c}$ quantification with full SI-traceability and other similar proteins in complex biological samples.

Effect of Pretense (Subtilisin Carlsberg) on the Removal of Blood Protein Soil (I) -The Hydrolysis of Hemoglobin by Subtilisin Carlsberg- (Protease(Subtilisin Carlsberg)가 혈액 단백질 오구의 제거에 미치는 영향(I) -Subtilisin Carlsberg에 의한 헤모글로빈의 가수분해율-)

  • 이정숙;김성연
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.3
    • /
    • pp.550-559
    • /
    • 1996
  • The Effect of protease (subtilisin Carlsberg) on the removal of hemoglobin as protein soil was studied. The hydrolysis characteristics of subtilisin Carlsberg was examined by electrophoretic techniques. The fragmentation patterns of hemoglobin were analyzed by SDS-PAGE. The hydrolysis efficiency was evaluated by analysis of protein bands shown on gels before and after hydrolysis by using densitometer. 1. The hydrolysis of hemoglobin by subtilisin Carlsberg was increased markedly with the increase of the enzyme concentration. 2. The hydrolysis of hemoglobin by subtilisin Carlsberg was effectively increased in proportion to increasing of the hemoglobin concentration up to a certain point, but it began to decrease above the point. 3. The hydrolysis of hemoglobin by subtilisin Carlsberg followed the first order kinetics, yielding a rate constant of $4.05\time10^{-4}S^{-1}s$. 4. The hydrolysis of hemoglobin by subtilisin Carlsberg was highest at $50^{\circ}C$ and was decreased markedly at $80^{\circ}C$. 5. The hydrolysis of hemoglobin was comparatively low at pH 7.0~8.0, and highest at pH 11.0.

  • PDF

Novel Detection Technology for Glycated Hemoglobin using Gold Nanoparticles (금 나노입자를 이용한 새로운 당화혈색소의 검출 기술)

  • Lee, Soo Suk
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.435-439
    • /
    • 2016
  • We report a novel detection technology for glycated hemoglobin (HbA1c) that is measured primarily to identify the three-month average plasma glucose concentration. In enzymatic measuring of glycated hemoglobin, the generated hydrogen peroxide was then used as a reducing agent of gold (III) for the synthesis of gold (0). Gold nanoparticles obtained from this novel approach were measured by optical and piezoelectric methods. In optical method, we have developed polymer based film-type sensor cartridge filled with all the reagents for glycated hemoglobin analysis and the cartridge worked very well having the detection limit of 0.53% of glycated hemoglobin. On the other hand, quartz crystal microbalance (QCM) sensors also have been developed to determine the abilities of surface modified QCM sensors at various levels of the concentration of glycated hemoglobin to bind gold nanoparticles and limit of detection was 0.90%. Finally, despite of relatively lower sensitivities of QCM sensor and film-type optical sensor than well-plate based optical detection, these two sensors were available to measure the glycated hemoglobin level for diabetes patients and normal person.

Studies on Types of Hemoglobin, Albumin and Transferrin in Dogs (개의 Hemoglobin, Albumin 및 Transferrin의 형(型)에 관(關)한 연구(硏究))

  • Kim, Woo Kwon
    • Korean Journal of Veterinary Research
    • /
    • v.14 no.2
    • /
    • pp.191-200
    • /
    • 1974
  • Hemoglobin, albumin and transferrin phenetypes observed in a population of 255 dogs of various breeds by agar gel electrophoresis for hemoglobin and albumin, and by starch gel electrophoresis, for transferrin. The results obtained were as follows: 1. The hemoglobin phenotypes were classified as HbAA, HbAB and HbBB and the frequencies of appearence were 91.77, 6.27 and 1.96%, respectively. Gene frequency studies of $Hb^A$ and $Hb^B$ showed the $Hb^A$ gene to have a frequency of 94.9% and $Hb^B$ gene to have a frequency of 5.1. The frequency of hemoglobin phenotypes of the Korean Jindo dog (ylelow) was HbAA 76.19%, HbAB 17.46% and HbBB 6.35% and HbBB was recognized only in the Korean Jindo dogs. 2. The albumin phenotypes were calssified as AlbAA, AlbAB and AlbBB and the frequencies of appearence were 28.71, 43.57 and 27.72% respectively. Gene frequency stduies of $Alb^A$ and $Alb^B$ showed the $Alb^A$ gene to hate a frequency of 50.50% and $Alb^B$ gene to have a frequency of 49.50. The frequency of albumin phenotypes of the Korean Jindo dog was 26.32% for AlbAA, 34.21% for AlbAB and 39.47% for AlbBB. The frequency of albumin phenotypes of the Korean Jindo dog was slightly different from others and gene frequency of $Alb^B$ was 56.58. 3. Transferrin studies resulted in findings of 10 different phenotypes and frequencies of transferrin phenotype were 30.08% for $TfA_1A_1$, 8.02 for $TfA_2A_2$, 2.11 for TfBB, 4.64 for $TfC_1C_1$, 1.69 for $TfA_1B$, 41.35 for $TfA_1C_1$, 5.49 for $TfA_2C_1$, 0.84 for $TfA_2C_2$ and 3.79 for $TfBC_1$. Gene frequency studies of $Tf^A$, $Tf^B$ and $Tf^C$ showed the gene to have a frequency of 63.08% for $Tf^A$, 4.85 for $Tf^B$ and 32.07 for $Tf^C$ 4. Transferrin studies revealed two different band patterns on starch gels with a strong and weaker stained one. The $TfC_2C_2$ and $TfA_2A_2$ which were found in the Korean Jindo dog only showed a weaker stained band and the gene frequency of $TfA_1A_1$ was highly recognized in this dog.

  • PDF

Effect of Pretense (Subtilisin Carlsberg) on the Removal of Blood Protein Soil (II) -The Detergency of Hemoglobin from Cotton Fabics- (Protease (Subtilisin Carlsberg) 가 혈액 단백질 오구의 제거에 미치는 영향(II) -헤모글로빈 오구포의 세척성-)

  • 이정숙;김성연
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.4
    • /
    • pp.655-666
    • /
    • 1996
  • The effect of protease (subtilisin Carlsberg) on the removal of hemoglobin as protein soil was studied. The relation between the renloval and the hydrolysis of hemoglobin by subtilisin Carlsberg was discussed. The soiled babric was prepared by spotting of hemoglobin solution evenly on the cotton fabric and was denatured by steaming. The soiled fabric was washed by using Terg-0-Tometer at various conditions. The removal efficiency was evaluated by analysis of protein on the fabrics before and after washing by means of copper-Folin method. 1. The removal of hemoglobin was increased in proportion to increasing of the enzyme concentration up to a certain point, but it began to decrease above the point. 2. The hemoglobin was removed effectively by adding of subtilisin Carlsberg, and more effectively removed by adding of AOS in the enzyme solution. 3. The removal of hemoglobin deviated from the first order reaction in detergency. 4. The renloval of hemoglobin was highest at $50^{\circ}C$ in detergency, Even at low temperature the removal efficiency of enzyme was relatively higher compared with the hydrolysis of hemoglobin by the enzyme. However the removal of hemoglobin was apparently decreased with the increase of temperature over $60^{\circ}C$. 5. The removal of hemoglobin was relatively high at pH 7.0~8.0 and increased continuously with the increase of pH in detergency 6. In detergency, the removal mechanism of hemoglobin by subtilisin Carlsberg could be explained as follows: Fisrt of all, the enzyme hydrolyzed hemoglobin substrates partially by forming E-S complex at the surface of hemoglobin on the cotton fiber, and decomposed cooperative binding of hemoglobin. Subsequently, the fragments of hemoglobin were easily removed by washing. According as the enzyme penetrated to inner part of hemoglobin gradually, the hemoglobin on the cotton fiber was effectively removed by the repetition of these process. The removal of hemoglobin was more effectively increased by adding both the enzyme and AOS in the washing solution. Therefore, it was regarded that AOS molecules were adsorbed at the hydrophobic surface of denatured hemoglobin, subsequently, decomposed more effectively cooperative binding of hemoglobin, and the fragments of hemoglobin were removed more efficiently by means of the interfacial reaction of AOS.

  • PDF

The Study Related to Perceived Stress, Stress Coping Method, Self-Care Behavior and Hemoglobin $A_1c$ of Elderly Diabetic Mellitus Patients (노인 당뇨병환자의 스트레스 지각, 스트레스 대처방식, 자가간호행위 및 당화혈색소와의 관계)

  • Park, Mi-Yon;Kim, Kyung-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.15 no.2
    • /
    • pp.186-194
    • /
    • 2008
  • Purpose: The purpose of this studγ is to understand relations among perceived stress, stress coping method, self-rare behavior and Hemoglobin $A_1c$ of elderly diabetic mellitus patients. Method: Participants were 128 patients who were under medical treatment in outpatient department at C university hospital. The collected data were analyzed using technical statistics, frequency, percentage, T-test, ANOVA and person's correlation coefficient by SPSS 12.0. Result: There were positive correlation between self-care behavior and coping method based on emotions under the lower category of stress coping method. Hemoglobin $A_1c$ of patients had a negative correlation with physical exorcise of self coping method under the lower category. Perceived stress had also a negative correlation with emotions as coping method in the lower category and medication of self-care behavior. Conclusion: It was noted that elderly diabetic mellitus patients didn't much use a coping method based mainly problems and another method based emotions in case of perceived stress. The findings of this study will be useful for developing an nursing intervention program focused on elderly diabetic mellitus patients.

  • PDF

Analysis of Electronic Endoscopic Image of Intramucosal Gastric Carcinoma Using Hemoglobin Index

  • Kim Gwang-Ha;Lim Eun-Kyung;Kim Kwang-Baek
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.16 no.3
    • /
    • pp.332-337
    • /
    • 2006
  • It has been suggested that the endoscopic color of intramucosal gastric carcinoma is correlated with mucosal vascularity within the carcinomatous tissue. The development of electronic endoscopy has made it possible to quantitatively measure the mucosal hemoglobin volume, using a hemoglobin index. The aim of this study was to make a software program to calculate the hemoglobin index (IHb) and then investigate whether the mucosal IHb determined from the electronic endoscopic data is a useful marker for evaluating the color of intramucosal gastric carcinoma, in particular with regard to its value for discriminating between the histologic types. The mean values of IHb for the carcinoma (IHb-C) and the mean values of IHb for the surrounding non-cancerous mucosa (IHb-N) were calculated in 75 intestinal-type and 34 diffuse-type gastric carcinomas. Then, we analyzed the ratio of the IHb-C to IHb-N. The mean IHb-C/IHb-N ratio in the intestinal-type carcinoma group was higher than that in the diffuse-type carcinoma group (1.28$\pm$0.19 vs. 0.81$\pm$0.18, respectively, p<0.001). When the cut-off point of the C/N ratio was set at 1.00, the accuracy rate, the sensitivity, the specificity, and the positive and negative predictive values of a C/R ratio below 1.00 for the differential diagnosis of diffuse-type carcinoma from intestinal-type carcinoma were 94.5%, 94.1%, 94.7%, 88.9% and 97.3%, respectively. IHb is useful for quantitative measurement of the endoscopic color in intramucosal gastric carcinoma and the IHb-C/IHb-N ratio would be helpful in distinguishing diffuse-type carcinoma from intestinal-type carcinoma.