Objective: This study was to investigate the relationship between hemoglobin A1c level and self-reported oral health status. Methods: The subjects of this study were 150 diabetic patients (60 male patients and 90 female patients) who went to the internal and family medicine departments of clinic. This study used the questionnaire and NYCOCARD$\square$ READERII to quantify hemoglobin A1c. Results: The proportion of well controlled diabetes subjects was 31.3%. When hemoglobin A1c levels became higher, subjects perceived that there were more decay teeth, bleeding, swollen gums, mobility teeth, and oral disease symptoms. In comparison with the well glycemic control group, poor glycemic control group perceived that the overall oral health status was worse, and had more bleeding teeth, swollen gums and mobility teeth. Conclusion: These results show that hemoglobin A1c level is related to the self-reported oral health status. Therefore, dental professionals should emphasize more the necessity of maintaining the hemoglobin A1c of normal range and monitoring it periodically, and the practice of thorough oral hygiene care in order to promote diabetic patients' oral health.
Glycated hemoglobin (HbA1c) is used as an index of mean glycemia over prolonged periods. This study describes an optimization of enzyme digestion conditions for quantification of non-glycated hemoglobin (HbA0) and HbA1c as diagnostic markers of diabetes mellitus. Both HbA0 and HbA1c were quantitatively determined followed by enzyme digestion using isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) with synthesized N-terminal hexapeptides as standards and synthesized isotope labeled hexapeptides as internal standards. Prior to quantification, each peptide was additionally quantified by amino acid composition analysis using ID-LC-MS/MS via acid hydrolysis. Each parameter was considered strictly as a means to improve digestion efficiency and repeatability. Digestion of hemoglobin was optimized when using 100 mM ammonium acetate (pH 4.2) and a Glu-C-to-HbA1c ratio of 1:50 at $37^{\circ}C$ for 20 h. Quantification was satisfactorily reproducible with a 2.6% relative standard deviation. These conditions were recommended for a primary reference method of HbA1c quantification and for the certification of HbA1c reference material.
Journal of Korean Academy of Fundamentals of Nursing
/
v.22
no.4
/
pp.433-441
/
2015
Purposes: This study was done to identify factors associated with uncontrolled hemoglobin A1c among patient with diabetes mellitus. Method: The sample was 412 Koreans with diagnosed diabetes aged 40 years or older who participated in the Fifth Korea Health and Nutrition Examination survey, which was a nationwide, cross-sectional survey. Data was analyzed using logistic regression. Uncontrolled hemoglobin A1c rate was 55%. Results: There was a difference between controlled and uncontrolled group in hemoglobin A1c as follows: duration of diabetes, BMI(Body Mass Index), hypertriglyceridemia, vitamin D, sleep duration. After adjusting for confounding factor, longer duration of diabetes (>7 years vs. ${\leq}7$)(Adjusted OR=2.277, 95% CI [1.277-4.060]), presence of hypertriglyceridemia (Adjusted OR=4.019, 95% CI [1.871-8.634]), lower vitamin D level (<20ng/mL vs. ${\geq}20$)(Adjusted OR=2.487, 95% CI[1.411-4.381]), longer sleep duration (6-8 hours vs >8 hours)(Adjusted OR=6.831, 95% CI [1.877-24.855]) were significantly associated with increased odds of uncontrolled hemoglobin A1c. Conclusions: Results show that duration of diabetes, hypertriglyceridemia, vitamin D and sleep duration are significantly related to hemoglobin A1c. Therefore, considering these factors it would be helpful to develop strategies to improve blood glucose control in patients with diabetes.
Glycated hemoglobin ($HbA_{1c}$) has been commonly used to screen and diagnose for patients with diabetes mellitus. Here the accelerated procedure of microwave-assisted sample treatment from acid hydrolysis to enzyme digestion followed by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) was optimized and applied to measure $HbA_{1c}$ in an effort to speed up analysis time. First, two signature peptides of $HbA_{1c}$ and hemoglobin $A_0$ were certified with amino acid analysis by setting optimized acid hydrolysis conditions to $150^{\circ}C$, 1.5 h and $10{\mu}M$ sample concentration in 8 M hydrochloric acid. Consequently, the accurate certified peptides above were used as calibration standards to implement the proteolytic procedure with endoproteinase Glu-C at $37^{\circ}C$, 700 W for 6 h. Compared to the traditional method, the microwave heating not only shortened dramatically sample preparation time, but also afforded comparable recovery yields. The optimized protocol and analytical conditions in this study are suitable for a primary reference method of $HbA_{1c}$ quantification with full SI-traceability and other similar proteins in complex biological samples.
Journal of the Korean Society of Clothing and Textiles
/
v.20
no.3
/
pp.550-559
/
1996
The Effect of protease (subtilisin Carlsberg) on the removal of hemoglobin as protein soil was studied. The hydrolysis characteristics of subtilisin Carlsberg was examined by electrophoretic techniques. The fragmentation patterns of hemoglobin were analyzed by SDS-PAGE. The hydrolysis efficiency was evaluated by analysis of protein bands shown on gels before and after hydrolysis by using densitometer. 1. The hydrolysis of hemoglobin by subtilisin Carlsberg was increased markedly with the increase of the enzyme concentration. 2. The hydrolysis of hemoglobin by subtilisin Carlsberg was effectively increased in proportion to increasing of the hemoglobin concentration up to a certain point, but it began to decrease above the point. 3. The hydrolysis of hemoglobin by subtilisin Carlsberg followed the first order kinetics, yielding a rate constant of $4.05\time10^{-4}S^{-1}s$. 4. The hydrolysis of hemoglobin by subtilisin Carlsberg was highest at $50^{\circ}C$ and was decreased markedly at $80^{\circ}C$. 5. The hydrolysis of hemoglobin was comparatively low at pH 7.0~8.0, and highest at pH 11.0.
We report a novel detection technology for glycated hemoglobin (HbA1c) that is measured primarily to identify the three-month average plasma glucose concentration. In enzymatic measuring of glycated hemoglobin, the generated hydrogen peroxide was then used as a reducing agent of gold (III) for the synthesis of gold (0). Gold nanoparticles obtained from this novel approach were measured by optical and piezoelectric methods. In optical method, we have developed polymer based film-type sensor cartridge filled with all the reagents for glycated hemoglobin analysis and the cartridge worked very well having the detection limit of 0.53% of glycated hemoglobin. On the other hand, quartz crystal microbalance (QCM) sensors also have been developed to determine the abilities of surface modified QCM sensors at various levels of the concentration of glycated hemoglobin to bind gold nanoparticles and limit of detection was 0.90%. Finally, despite of relatively lower sensitivities of QCM sensor and film-type optical sensor than well-plate based optical detection, these two sensors were available to measure the glycated hemoglobin level for diabetes patients and normal person.
Hemoglobin, albumin and transferrin phenetypes observed in a population of 255 dogs of various breeds by agar gel electrophoresis for hemoglobin and albumin, and by starch gel electrophoresis, for transferrin. The results obtained were as follows: 1. The hemoglobin phenotypes were classified as HbAA, HbAB and HbBB and the frequencies of appearence were 91.77, 6.27 and 1.96%, respectively. Gene frequency studies of $Hb^A$ and $Hb^B$ showed the $Hb^A$ gene to have a frequency of 94.9% and $Hb^B$ gene to have a frequency of 5.1. The frequency of hemoglobin phenotypes of the Korean Jindo dog (ylelow) was HbAA 76.19%, HbAB 17.46% and HbBB 6.35% and HbBB was recognized only in the Korean Jindo dogs. 2. The albumin phenotypes were calssified as AlbAA, AlbAB and AlbBB and the frequencies of appearence were 28.71, 43.57 and 27.72% respectively. Gene frequency stduies of $Alb^A$ and $Alb^B$ showed the $Alb^A$ gene to hate a frequency of 50.50% and $Alb^B$ gene to have a frequency of 49.50. The frequency of albumin phenotypes of the Korean Jindo dog was 26.32% for AlbAA, 34.21% for AlbAB and 39.47% for AlbBB. The frequency of albumin phenotypes of the Korean Jindo dog was slightly different from others and gene frequency of $Alb^B$ was 56.58. 3. Transferrin studies resulted in findings of 10 different phenotypes and frequencies of transferrin phenotype were 30.08% for $TfA_1A_1$, 8.02 for $TfA_2A_2$, 2.11 for TfBB, 4.64 for $TfC_1C_1$, 1.69 for $TfA_1B$, 41.35 for $TfA_1C_1$, 5.49 for $TfA_2C_1$, 0.84 for $TfA_2C_2$ and 3.79 for $TfBC_1$. Gene frequency studies of $Tf^A$, $Tf^B$ and $Tf^C$ showed the gene to have a frequency of 63.08% for $Tf^A$, 4.85 for $Tf^B$ and 32.07 for $Tf^C$ 4. Transferrin studies revealed two different band patterns on starch gels with a strong and weaker stained one. The $TfC_2C_2$ and $TfA_2A_2$ which were found in the Korean Jindo dog only showed a weaker stained band and the gene frequency of $TfA_1A_1$ was highly recognized in this dog.
Journal of the Korean Society of Clothing and Textiles
/
v.20
no.4
/
pp.655-666
/
1996
The effect of protease (subtilisin Carlsberg) on the removal of hemoglobin as protein soil was studied. The relation between the renloval and the hydrolysis of hemoglobin by subtilisin Carlsberg was discussed. The soiled babric was prepared by spotting of hemoglobin solution evenly on the cotton fabric and was denatured by steaming. The soiled fabric was washed by using Terg-0-Tometer at various conditions. The removal efficiency was evaluated by analysis of protein on the fabrics before and after washing by means of copper-Folin method. 1. The removal of hemoglobin was increased in proportion to increasing of the enzyme concentration up to a certain point, but it began to decrease above the point. 2. The hemoglobin was removed effectively by adding of subtilisin Carlsberg, and more effectively removed by adding of AOS in the enzyme solution. 3. The removal of hemoglobin deviated from the first order reaction in detergency. 4. The renloval of hemoglobin was highest at $50^{\circ}C$ in detergency, Even at low temperature the removal efficiency of enzyme was relatively higher compared with the hydrolysis of hemoglobin by the enzyme. However the removal of hemoglobin was apparently decreased with the increase of temperature over $60^{\circ}C$. 5. The removal of hemoglobin was relatively high at pH 7.0~8.0 and increased continuously with the increase of pH in detergency 6. In detergency, the removal mechanism of hemoglobin by subtilisin Carlsberg could be explained as follows: Fisrt of all, the enzyme hydrolyzed hemoglobin substrates partially by forming E-S complex at the surface of hemoglobin on the cotton fiber, and decomposed cooperative binding of hemoglobin. Subsequently, the fragments of hemoglobin were easily removed by washing. According as the enzyme penetrated to inner part of hemoglobin gradually, the hemoglobin on the cotton fiber was effectively removed by the repetition of these process. The removal of hemoglobin was more effectively increased by adding both the enzyme and AOS in the washing solution. Therefore, it was regarded that AOS molecules were adsorbed at the hydrophobic surface of denatured hemoglobin, subsequently, decomposed more effectively cooperative binding of hemoglobin, and the fragments of hemoglobin were removed more efficiently by means of the interfacial reaction of AOS.
Journal of Korean Academy of Fundamentals of Nursing
/
v.15
no.2
/
pp.186-194
/
2008
Purpose: The purpose of this studγ is to understand relations among perceived stress, stress coping method, self-rare behavior and Hemoglobin $A_1c$ of elderly diabetic mellitus patients. Method: Participants were 128 patients who were under medical treatment in outpatient department at C university hospital. The collected data were analyzed using technical statistics, frequency, percentage, T-test, ANOVA and person's correlation coefficient by SPSS 12.0. Result: There were positive correlation between self-care behavior and coping method based on emotions under the lower category of stress coping method. Hemoglobin $A_1c$ of patients had a negative correlation with physical exorcise of self coping method under the lower category. Perceived stress had also a negative correlation with emotions as coping method in the lower category and medication of self-care behavior. Conclusion: It was noted that elderly diabetic mellitus patients didn't much use a coping method based mainly problems and another method based emotions in case of perceived stress. The findings of this study will be useful for developing an nursing intervention program focused on elderly diabetic mellitus patients.
Journal of the Korean Institute of Intelligent Systems
/
v.16
no.3
/
pp.332-337
/
2006
It has been suggested that the endoscopic color of intramucosal gastric carcinoma is correlated with mucosal vascularity within the carcinomatous tissue. The development of electronic endoscopy has made it possible to quantitatively measure the mucosal hemoglobin volume, using a hemoglobin index. The aim of this study was to make a software program to calculate the hemoglobin index (IHb) and then investigate whether the mucosal IHb determined from the electronic endoscopic data is a useful marker for evaluating the color of intramucosal gastric carcinoma, in particular with regard to its value for discriminating between the histologic types. The mean values of IHb for the carcinoma (IHb-C) and the mean values of IHb for the surrounding non-cancerous mucosa (IHb-N) were calculated in 75 intestinal-type and 34 diffuse-type gastric carcinomas. Then, we analyzed the ratio of the IHb-C to IHb-N. The mean IHb-C/IHb-N ratio in the intestinal-type carcinoma group was higher than that in the diffuse-type carcinoma group (1.28$\pm$0.19 vs. 0.81$\pm$0.18, respectively, p<0.001). When the cut-off point of the C/N ratio was set at 1.00, the accuracy rate, the sensitivity, the specificity, and the positive and negative predictive values of a C/R ratio below 1.00 for the differential diagnosis of diffuse-type carcinoma from intestinal-type carcinoma were 94.5%, 94.1%, 94.7%, 88.9% and 97.3%, respectively. IHb is useful for quantitative measurement of the endoscopic color in intramucosal gastric carcinoma and the IHb-C/IHb-N ratio would be helpful in distinguishing diffuse-type carcinoma from intestinal-type carcinoma.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.