• 제목/요약/키워드: Hemodynamic failure

검색결과 108건 처리시간 0.026초

소경정맥 판막도관을 이용한 우심실 유출로 재건술 (Right Ventricular Outflow Tract Reconstruction with Bovine Jugular Venous Valved Conduit.)

  • 박형주
    • Journal of Chest Surgery
    • /
    • 제33권10호
    • /
    • pp.830-833
    • /
    • 2000
  • Homograft has been the conduit of choice in various types of congenital malformations which require right ventricular outflow tract reconstruction. However it has been proven to be less than ideal in young age group because of early failure of the conduite due to valve dysfunction and calcification. Furthermore limitation of availability of homograft particularly small sized conduits for neonates and infants is the most serious problem. A 19 month old female patient with pulmonary atresia and ventricular septal defect was operated on with a bovine jugular venous valved conduit as an alternative to the homograft for her right ventricular outflow tract reconstruction. Postoperative hemodynamic performance of the conduit was excellent without pressure gradient or valve regurgitation. With this early result bovine jugular venous valved conduit seems to be another excellent conduit because of good hemodynamics and size availability but long term follow up is necessary.

  • PDF

혈액 투석 시 주사침에서의 투석량에 따른 인조혈관 내부 유동 특성에 관한 수치해석 연구 (Numerical Study on Blood Flow Characteristics in a Arteriovenous Graft with Delivered dose During Hemodialysis)

  • 김재열;노경철;유홍선
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.469-476
    • /
    • 2011
  • Hemodialysis is essential for patients with end stage renal failure. It is important to improve the patency rate and to minimize occurrence of the stenosis. Also, the blood flow to the artificial kidney can affect the blood flow characteristics though arteriovenous graft. Thus, the delivered dose are important factors for analyzing hemodynamic characteristics during hemodialysis access. In this study, the numerical analysis was performed for the effect of the delivered dose during hemodialysis access on the blood flow through the graft. As a result, The adverse pressure gradient occurred in case of a larger delivered dose through a catheter than standard dose and the flow instability increased. Also the circulation flow appeared largely at anastomotic site of the vein when the delivered dose was exceeded about half blood flow of inlet blood flow.

  • PDF

한국산 잡견에서의 실험적 심장이식술 (I) (Experimental Cardiac Transplantation in the Mongrel Dogs)

  • 전태국
    • Journal of Chest Surgery
    • /
    • 제22권6호
    • /
    • pp.936-943
    • /
    • 1989
  • We underwent 21 cases of orthotopic heart transplantation in the mongrel dogs from May, 1988, to April, 1989. The preoperative hematologic and hemodynamic results were similar to those of the previous reports except glucose and albumin. The exposure of operative field was excellent under the median sternotomy. All the cases died within 48 hours and the mean survival time excluding 4 operative deaths was 11.23*9.36 hours [\ulcorner.D., range 0.3-35.5 hours] We speculated the main cause of death was low cardiac output due to the myocardial failure. At autopsy, there was feature of intramyocardial hemorrhage and coagulation necrosis suggesting poor myocardial protection. Now our team is ready to do heart transplantation in man but we need more precise experiences, especially on the immunosuppression and myocardial protection. Recently we continue further experiments with improving results.

  • PDF

송아지를 이용한 한국형 인공심장의 동물실험에 관한 보고 (Experimental Study of the "Korean Artificial Heart" in Calf)

  • 서경필
    • Journal of Chest Surgery
    • /
    • 제22권2호
    • /
    • pp.202-211
    • /
    • 1989
  • We experienced a series of animal experimental studies of the total artificial heart in 1988. So called, "Korean Heart* was used in this study, which is developed and fabricated in the Department of Biomedical Engineering, College of Med., S.N.U.. "Korean Heart" is a Rolling-Cylinder Motor-Driven type which is a newly developed electromechanical heart over the shortcomes of the previous artificial hearts, especially pneumatic type. The advantages of the "Korean Heart" are total implantability, quiet and smooth movement, small size fittable in oriental people, etc. The animal experiments were performed two times, as an assist device in sheep and total artificial heart implant experiment in calf weighing 100 kg. After total implantation, the artificial heart was well functioned in movement and hemodynamic control. So that, the calf was recovered excellently, which was able to stand up by herself and take an oral intake. Total survival time was 100 hours and the cause of death was a sudden pumping failure [electrical connection problem]. Several postoperative laboratory results almost within normal limits and no hemolysis, but in autopsy, the multiple thromboembolic findings were seen at the lung and kidney.n at the lung and kidney.

  • PDF

이차공형 심방중격 결손중 (Secundum Type Atrial Septal Defect)

  • 박표원
    • Journal of Chest Surgery
    • /
    • 제14권3호
    • /
    • pp.241-246
    • /
    • 1981
  • A series of 132 consecutive cases of secundum type atrial septal defect operated from 1963 to 1980 in the department of Thoracic Surgery of Seoul National University Hospital is analysed. The ages of the patients ranged from 12 months to 57 years and the ratio of men to women was 1 to 1.4. Clinical analysis revealed 33 patients [26%] were asymptomatic and 15 patients [12%]had congestive heart failure. Hemodynamic analysis revealed that severe pulmonary hypertension which is the most serious risk factor is ASD developed in 10 patients [9%] and pulmonary artery pressure significantly increased after the age of 20 years. There were 10 patients with sinus venosus defect and 7 patients with partial anomalous pulmonary venous return. The operative mortality was 2.2%.

  • PDF

Anesthetic management of a patient with branchio-oto-renal syndrome

  • Tsukamoto, Masanori;Yokoyama, Takeshi
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제17권3호
    • /
    • pp.215-217
    • /
    • 2017
  • Branchio-oto-renal syndrome (BOR) is a rare autosomal dominant disorder. The features include branchial cysts, hearing loss, ear malformation, preauricular pits, retrognathia, congenital heart disease, and renal abnormalities. However, anesthetic management of these patients has seldom been reported. We report a case in which general anesthesia was performed for dental treatment in a patient with BOR. Airway management, renal function, and hemodynamic changes can be of critical concern during anesthetic management. A 13-year-old girl diagnosed with BOR had severe right hearing loss, right external ear malformation, renal abnormalities, and postoperative patent ductus arteriosus (PDA). Dental extraction under general anesthesia was scheduled for a supernumerary tooth. The procedure was completed with sufficient urine volume, adequate airway management, and stable hemodynamics.

Pulmonary stenosis and pulmonary regurgitation: both ends of the spectrum in residual hemodynamic impairment after tetralogy of Fallot repair

  • Yoo, Byung Won;Park, Han Ki
    • Clinical and Experimental Pediatrics
    • /
    • 제56권6호
    • /
    • pp.235-241
    • /
    • 2013
  • Repair of tetralogy of Fallot (TOF) has shown excellent outcomes. However it leaves varying degrees of residual hemodynamic impairment, with severe pulmonary stenosis (PS) and free pulmonary regurgitation (PR) at both ends of the spectrum. Since the 1980s, studies evaluating late outcomes after TOF repair revealed the adverse impacts of residual chronic PR on RV volume and function; thus, a turnaround of operational strategies has occurred from aggressive RV outflow tract (RVOT) reconstruction for complete relief of RVOT obstruction to conservative RVOT reconstruction for limiting PR. This transformation has raised the question of how much residual PS after conservative RVOT reconstruction is acceptable. Besides, as pulmonary valve replacement (PVR) increases in patients with RV deterioration from residual PR, there is concern regarding when it should be performed. Regarding residual PS, several studies revealed that PS in addition to PR was associated with less PR and a small RV volume. This suggests that PS combined with PR makes RV diastolic property to protect against dilatation through RV hypertrophy and supports conservative RVOT enlargement despite residual PS. Also, several studies have revealed the pre-PVR threshold of RV parameters for the normalization of RV volume and function after PVR, and based on these results, the indications for PVR have been revised. Although there is no established strategy, better understanding of RV mechanics, development of new surgical and interventional techniques, and evidence for the effect of PVR on RV reverse remodeling and its late outcome will aid us to optimize the management of TOF.

한국산 잡견에서의 실험적 심장 이식술 (II) (Experimental cardiac transplantation in the mongrel dogs (II))

  • 이정렬
    • Journal of Chest Surgery
    • /
    • 제23권5호
    • /
    • pp.844-853
    • /
    • 1990
  • We have performed 27 cases of orthotopic homologous cardiac transplantation using Korean mongrel dogs and one case of sham operation for the evaluation of harmful effect of cardiopulmonary bypass itself on the dog from April, 1989 to June, 1990. Our previous reports have already demonstrated basal hemodynamic and hematologic data on the canine homologous heart transplantation and the fundamental principles of transplantation of the heart. The mean body weight of recipients was 13.2$\pm$1.2kg with a rage of 11 ~ 15kg, and the hemodynamic and hematologic pictures were almost same as the result of previous reports from our hospital, except marked decrease in postoperative platelet count[from 3.18 $\pm$0.80x106/mm3 to 1.41$\pm$0 37x 106/mm3]. Mean survival time was 24.82$\pm$49.40 hours with the longest survival of 264 hours. Donor cardiectomy included coronary vasodilatation with diltiazem, potassium arrest, and the rapid cooling of the heart suspending in the specially designed ice-bath. Median sternotomy provided excellent exposure of the surgical field. 6 \ulcorner0 prolene suture was used for the anastomosis of both atrial cuffs and the great arteries, and we found the fact that stenosis, bleeding, thrombus formation around the anastomotic site could be decreased with the use of everted horizontal mattress suture techniques. Immunosuppression was done with a combination of lower dose Cyclosporin-A, Azathioprine, methyl-prednisolone, but our cases still showed too short survival to worry about graft rejection. Still poor was our quality control of experimental animal, we had much difficulties in postmortem evaluation of the dogs. Low cardiac output due to biventricular failure, intractable supraventricular or ventricular tachyarrhythmia, postoperative massive bleeding, sepsis were most frequent findings that could be thought as a cause of death. A few cases showed subendocardial patch hemorrhage in both ventricular cavity or atrial septum at autopsy, suggesting acute subendocardial infarction. Although our team overcome most of the technical problems of orthotopic heart transplantation, we should pile up further knowledges about donor heart preservation, quality control of animal, infection, rejection, the effect of the cardiopulmonary bypass to improve the results.

  • PDF

말기신질환에서 혈액투석에 따르는 좌우심실용적 및 기능변화에 관한 연구 (Effect of Hemodialysis on Left and Right Ventricular Volume and Function)

  • 한진석;고창순
    • 대한핵의학회지
    • /
    • 제19권2호
    • /
    • pp.43-50
    • /
    • 1985
  • With the improvement of hemodialysis, the course of the disease in patient with endstage renal disease has been clearly improved. Nevertheless, among several shortcomings to our present mode of renal replacement therapy, cardiovascular complications have been the leading cause of morbidity and mortality. Several factors such as anemia, arteriovenous shunting of blood, intermittent extracorporeal circulation and hypertension may be contributing. But little is known about the quantitative cardiac hemodynamic characteristics occurred during hemodialysis. The purpose of this study is to observe the sequential hemodynamic changes before, during and after the hemodialysis and to investigate reliable parameters in the detection of ventricular dysfunction. In the present study, equilibrium radionuclide cardiac angiography was performed and left and right ventricular volume indices, ejection phase indices of both ventricular, performance were measured in the 16 stable patients with chronic renal failure treated with maintenance hemodialysis sequentially i.e. before, during (early and late phase) and after the hemodialysis. The results obtained were as follows; 1) The indices of the left ventricular function were not changed during the hemodialysis but increased after the hemodialysis. 2) The indices of the right ventricular function(EF, SVI) were significantly decreased in the early phase (15, 30 minutes after starting extracorporeal circulation) but recovered after the hemodialysis. 3) The ratio of right ventricular to left ventricular ejection fraction was significantly decreased in the early phase and the lung volume indices were significantly increased at the same phase. As a conclusion, hemodialysis improves left ventricular function maybe due to increased contractility, and effects on the right ventricular function maybe due to the increased lung volume in the early phase of hemodialysis.

  • PDF

웹 기반 인공심장 모니터링 시스템의 설계와 구현 (Design and Implementation of the Web-based Monitoring System for an Artificial Heart)

  • 정진한;최재순;이지훈;민병구
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권2호
    • /
    • pp.131-137
    • /
    • 2002
  • 이동 작동기형 인공 심장의 원격 모니터링을 위한 시스템을 설계, 구현하였다 동물 실험이나 환자에의 임상 실험 후 인공 심장 동작 상황에 대한 원격 모니터링은 필수적이다. 본 논문에서는 담당자가 환자로부터 멀리 떨어진 곳에 있을 때에도 인터넷을 통해 간편하게 인공 심장의 동작 상황과 혈류역학 정보를 확인할 수 있는 시스템을 제안하여 그 성능을 확인하였다. 기존의 시스템과 쉽게 연결하여 사용할 수 있도록. 또 쉬운 관리와 기능 향상을 위하여 COM(Component Object Model) 기술 기반의 콤포넌트 모듈로 데이터 전송 부분을 구현하였고. 범용의 브라우저를 이용하여 인터넷에 연결, 확인토록 자바 애플릿을 이용하여 실행되도록 하였다. 또한 정해진 룰에 따라 판단하여 인공 심장의 이상 동작시 관리자에게 알려주도록 하였다. 구현된 시스템을 1개월 이상 생존하는 동물에 적용하여 본 결과 아무런 문제없이 정상 동작함을 확인하였다.