• Title/Summary/Keyword: Hemodynamic

Search Result 854, Processing Time 0.035 seconds

The Respiratory and Hemodynamic Effect of Prone Position in Patients with ARDS (급성호흡부전증후군에서 Prone Position의 호흡 및 혈류역학적 효과)

  • Lim, Chae-Man;Koh, Youn-Suck;Jung, Bok-Hyun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1105-1113
    • /
    • 1997
  • Background : Prone position improves oxygenation in some patients with ARDS. According to some authors, prone position can also improve the deteriorated hemodynamics induced by PEEP. But these respiratory and hemodynamic effects of prone position has not yet been fully established. Methods : Twentythree consequtive patients with ARDS(M : F= 11 : 12, $62.1{\pm}20.8yrs$) were the subjects for this study. ABGA, static compliance of the respiratory system, mean arterial pressure and pulse rate were obtained in supine position and at 5min, 0.5h and 2h of prone position. Positive respiratory response was defined as 20mmHg or more increase in $PaO_2/FIO_2$ within 2h of prone position. Early of late respiratory responses were defined if the positive response was observed within of after 3 day of ARDS onset, respectively. Positive hemodynamic response was defined as 10mmHg or more increase in mean arterial pressure at 5min of prone position. Results : Fifteen patients (65%) showed positive respiratory response. In the respiratory responders, $PaO_2$ was $69.8{\pm}17.6mmHg$ in supine position, $83.2{\pm}22.6mmHg$ in prone position 0.5h, $96.8{\pm}22.7mmHg$ in prone position 2h(p<0.001), and $PaO_2/FIO_2$ was $108{\pm}41mmHg$, $137{\pm}57mmHg$, $158{\pm}50mmHg$, respectively(p=0.001). Age, sex, cause of ARDS, supine $PaO_2$ and $PaO_2/FIO_2$ were not different between the respiratory responders and the nonresponders. The respiratory responders, however, showed higher mean arterial pressure than the nonresponders($91.1{\pm}13.1mmHg$ vs. $76.0{\pm}18.7mmHg$, p=0.035), and tendency of higher survival rate(9/15 vs. 2/8, p=0.074). Static compliance of the respiratory system was decreased in prone position 0.5h($28.4{\pm}7.9ml/cm$ $H_2O$ vs. $23.8{\pm}7.6ml/cm$ $H_2O$, p=0.007). The overall rate of early response(n=23) and late response(n=11) were similar(14/23 vs. 7/11, p>0.05). But patient without early response showed late response only in 25%(1/4), while patient with early response showed late response in 85.7%(6/7)(p=0.072). Five patients(22%) showed positive hemodynamic response, two of them being respiratory nonresponders. There were no differences in the baseline mean arterial pressure or the level of PEEP applied in supine between the hemodynamic responders and the hemodynamic nonresponders. Conclusions : Prone position either improved oxygenation or increased arterial pressure in significant proportion of patients with ARDS. And the respiratory response to prone position was thought to be determined in the early stage of ARDS.

  • PDF

Comparison of the hemodynamic effects of propofol and ketamine as anesthetic induction agents during high-dose remifentanil administration: a single-center retrospective comparative study

  • Sanuki, Takuro;Mishima, Gaku;Kurata, Shinji;Watanabe, Toshihiro;Kiriishi, Kensuke;Tachi, Mizuki;Ozaki, Yu;Okayasu, Ichiro;Kawai, Mari;Matsushita, Yuki;Miura, Keiichiro;Ayuse, Takao
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.3
    • /
    • pp.129-134
    • /
    • 2015
  • Background: We hypothesized that ketamine, when administered as the anesthetic induction agent, may prevent cardiovascular depression during high-dose remifentanil administration, unlike propofol. To test our hypothesis, we retrospectively compared the hemodynamic effects of ketamine, during high-dose remifentanil administration, with those of propofol. Methods: Thirty-eight patients who underwent oral surgery at the Nagasaki University Hospital between April 2014 and June 2015 were included in this study. Anesthesia was induced by the following procedure: First, high-dose remifentanil ($0.3-0.5{\mu}g/kg/min$) was administered 2-3 min before anesthesia induction;next, the anesthetic induction agent, either propofol (Group P) or ketamine (Group K), was administered. Mean arterial pressure (MAP) and the heart rate were recorded by the automated anesthesia recording system at four time points: immediately before the administration of high-dose remifentanil (T1);immediately before the administration of propofol or ketamine (T2);2.5 min (T3), and 5 min (T4) after the administration of the anesthetic induction agent. Results: In Group P, the MAP at T3 ($75.7{\pm}15.5mmHg$, P = 0.0015) and T4 ($68.3{\pm}12.5mmHg$, P < 0.001) were significantly lower than those at T1 ($94.0{\pm}12.4mmHg$). However, the MAP values in the K group were very similar (P = 0.133) at all time points. The heart rates in both Groups P (P = 0.254) and K (P = 0.859) remained unchanged over time. Conclusions: We showed that ketamine, when administered as the anesthetic induction agent during high-dose remifentanil administration, prevents cardiovascular depression.

Hemodynamic evaluation of the Ionescu-Shiley pericardial xenograft heart valve (Ionescue-Shiley 인조판막을 이용한 판막대치술의 혈류역학적 성적)

  • Jeong, Won-Sang;Kim, Geun-Ho
    • Journal of Chest Surgery
    • /
    • v.17 no.2
    • /
    • pp.223-230
    • /
    • 1984
  • Since January 1977 to the end of September 1982, total 60 Ionescu-Shiley pericardial xenograft heart valves were implanted for valve replacement in 50 patients at the Han Yang University Hospital. The operative procedures were as follow: Mitral valve replacement [MVR] in 25 patients, Mitral valve replacement [MVR] and Tricuspid valve [TV] annuloplasty in 7 patients, Aortic valve replacement [AVR] in 8 patients, Aortic valve replacement [AVR] and Mitral valve replacement [MVR] in 8 patients. Aortic valve replacement [AVR] and Mitral valve replacement [MVR] and Tricuspid valve [TV] annuloplasty in 2 patients. To evaluate the immediate hemodynamic changes after valve replacements, the pressures of each cardiac chamber and ulmonary artery were checked before and after valve replacement on the operation table. Right ventricle [RV] pressure was decreased from 52.09\ulcorner6.71 to 45.57\ulcorner5.03 mmHg, Pulmonary artery [PA] pressure was decreased from 45.97\ulcorner2.69 to 41.00\ulcorner3.99 mmHg, and Left atrium [LA] pressure was decreased from 30.33\ulcorner13.02 to 22.76\ulcorner.97 mmHg before and after valve replacement. In MVR group, RV pressure was decreased from 49.17\ulcorner7.89 to 43.14\ulcorner4.14 mmHg, PA pressure was decreased from 44.67\ulcorner3.18 to 38.67\ulcorner2.85 mmHg, and LA pressure was decreased from 31.46\ulcorner13.47 to 21.91\ulcorner.17 mmHg. In AVR group, RV pressure was decreased from 53.0\ulcorner7.44 to 44.71 \ulcorner3.24 mmHg, PA pressure was decreased from 34.83\ulcorner0.73 to 31.86\ulcorner.36 mmHg, and LA pressure was not changed. In double valve replacement [MVR and AVR] group, RV pressure was decreased from 57.50\ulcorner3.82 to 42.50\ulcorner.80 mmHg, PA pressure was decreased from 51.17\ulcorner1.42 to 43.33\ulcorner4.53mmHig, and LA pressure was decreased from 34.33\ulcorner2.09 to 25.50\ulcorner0.21 mmHg. But in the group where MVR and TV annuloplasty were performed, preoperative RV and PA pressure were markedly increased and no pressure decrease in RV and PA noticed after valve replacement. This study shows good immediate postoperative hemodynamic results after valve replacement using Ionescu-Shiley xenograft valve except in the cases of MVR and TV annuloplasty and advanced disease with pulmonary hypertension.

  • PDF

Clinical Analysis Of Ventricular Septal Defect (심실중격결손증의 외과적 고찰)

  • Seong, Suk-Hwan;Suh, Kyung-Pill
    • Journal of Chest Surgery
    • /
    • v.15 no.1
    • /
    • pp.90-97
    • /
    • 1982
  • Two hundred one patients of ventricular septal defect, which were operated at Seoul National University Hospital, were analysed on clinical background during the period from January, 1975 to December, 1980. The results were as follows: 1. Of the 201 patients, 118 patients were male [58.7%] and 83 patients were female [41.3%]. Their age ranged from 15 months to 40 years, and the mean age was 8.7 years. 40% of the patients were between 4 and 8 years. 2. The most common symptoms showed frequent U RI and exertional dyspnea. 3. On Kirklin`s anatomical classification, type I constituted 26.9%, type II 58.2%, type III 12.4%, and type IV 1.0%. We showed marked increased incidence of type I VSD as compared to Caucasians* 4. 46 cases were associated with other congenital cardiac diseases. They were PDA [13 cases], AI[11 ], ASD[6], PS[10], MI[4], and Double aortic arch [1]. 5. In 128 patients, who had complete hemodynamic data and were not associated with other congenital cardiac diseases, an attempt was made to correlate the EKG findings with the hemodynamic data, and defect size with the hemodynamic data. The children had variable distribution of PA syst. pr. and Rp/Rs. But most of adults had $R_P$/$R_S$of 0.15 or less. As $P_P$/$P_S$increased, the rate of operative complication increased also. 6. When a normal EKG pattern was present, $Q_P$/$Q_S$and $R_P$/$R_S$and $P_P$/$P_S$were relatively low. When EKG findings were LVH pattern, there was diastolic volume overload to left ventricle. As RVH, there was systolic pressure overload to right ventricle. And as BVH, there was mixed pattern of diastolic volume overload to left ventricle and systolic pressure overload to right ventricle. 7. Among patients in defect was less than 1 $cm^2$ per $M^2$ of BSA, $Q_P$/$Q_S$was less than 2:1, and $R_P$/$R_S$less than 0.25, and PAsyst. pr. less than 50 mmHg, and $P_P$/$P_S$was less than 0.5. But patients with the defect greater than 1 $cm^2$ per $M^2$ of BSA had no correlationship between $Q_P$/$Q_S$, $R_P$/$R_S$, PAsyst. pr. and defect size in each other. Most of patients with the defect greater than 2 $cm^2$/$M^2$ BSA, $R_P$/$R_S$was greater than 0.5. 8. Operative mortality rate was 9.5% [19 cases] among 201 patients. And complication rate including mortality rate was 22.9% [46 cases].

  • PDF

The Second Animal Tests of Artificial Heart Valves (인공심장판막의 개발과 동물실험 -인공심장판막의 2차 동물실험-)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.23 no.4
    • /
    • pp.617-621
    • /
    • 1990
  • A heart supplies blood of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to accomplish these enormous work of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of blood. In an attempt to eliminate the affliction of heart valves, the operative method to replace with artificial heart valves has developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. New artificial heart valves have been developed in Korea Advanced Institute of Science and Technology since early 1980`s. The first developed valve was designed with a free-floating pyrolytic carbon disk that is suspended in a titanium cage. The design of the valve was tested in vitro, and in animals in 1987. The results from this study was that the eccentrically placed struts creates a major and minor orifice when the disc opens and stagnation of flow in the area of the minor orifice has led to valve thrombosis. In this work, the design of the valve was changed from a single - leaflet valve to double - leaflet one in order to resolve the problems observed in the first - year tests. Morphological and hemodynamic studies were made for the newly designed valves through the in vitro and in vivo tests. The design and partial materials of the artificial heart valve was improved comparing with first - year`s model. The disc in the valve was modified from single - leaflet to bi - leaflet, and the material of the cage was changed from titanium metal to silicon - alloyed pyrolytic carbon. A test was made for the valve in order to examine its mechanical performance and stability. Morphological and hemodynamic studies were made for the valve that had been implanted in tricuspid position of mongrel dogs. All the test animals were observed just before the deaths. A new artificial heart valve was designed and fabricated in order to resolve the problems observed in the old model. The new valve was verified to have good stability and high resistance to wear through the performance tests. The hemodynamic properties of the valve after implantation were also estimated to be good in animal tests. Therefore, the results suggest that the newly designed valve in this work has a good quality in view of the biocompatibility. However, valve thrombosis on valve leaflets and annulus were found. This morphological findings were in accordance with results of surface polishing status studies, indicating that a technique of fine polishing of the surface is necessary to develop a valve with higher quality and performance.

  • PDF

Effects of changing position on cardiac output & on patient's discomforts after cardiac surgery (개심술을 받은 환자의 체위에 따른 심박출량 및 불편감에 관한 연구)

  • Yu Mi;Kwon Eun-Ok;Choi Yun-Kyoung;Kang Hyun-Ju;Oh Se-Eun
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.2
    • /
    • pp.256-270
    • /
    • 2000
  • Invasive hemodynamic monitoring has become a valuable assessment parameters in critical care nursing in patients undergoing open heart surgery patients. During cardiac surgery, the Swan Ganz catheter is placed in the pulmonary artery. Critical care nurses routinely obtain cardiac output, cardiac index, and pulmonary arterial pressure in these patients. Traditionally, patients are positioned flat and supine for cardiac output measurement. Numerous studies have dealt with the effects of changing position on the hemodynamic variables. However, there are a few studies dealing with patients who undergo cardiac surgery in Korea. Thus, the purpose of this study was to determine the effects of changing position on cardiac output, PAP, CVP, BP, HR and discomfort in patients after cardiac surgery. A sample of 21 adults who had CABG and/or valve replacement with Swan Ganz catheters in place was studied. The data were collected in the cardiac ICU of a university hospital in Seoul during the period from July 28, 1999 to August 30. 1999. In this study, the independent variable is patient position in the supine, 30 degree, and 45 degree angles. Dependent variables are C.O., C.I., CVP, PAP, MAP, HR and patients' perceived discomforts. Subject discomfort was measured subjectively by visual analogue scale. Other hemodynamic data where collected by the thermodilution method and by direct measurement. The data were analyzed by percentile, t-test, ANOVA, Linear regression analysis using SPSS-/WIN program. The results are as follows : 1) Changes in cardiac output were absent in different angle positions, 0, 30. 45 degrees(F=.070, P=.932). Changes in cardiac index were absent in different angle positions, 0. 30, 45 degrees(P>.05). 2) Changes in central venous pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 3) PAP had no change in different angle 0, 30, 45 degree positions; systolic PAP(P>.05), diastolic PAP(P>.05). 4) Changes in systolic blood pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 5) Changes in heart rates were absent in different angle positions, 0, 30, 45 degree(P>.05). 6) Patients' perceived discomfort was absent in different angle positions, 0, 30, 45 degree(p<.05). In conclusion, critical care nurses can measure C.O., C.I., PAP, BP, & CVP in cardiac surgery patients at 30 degree or 45 degree positions. This can improve the patients' comfort.

  • PDF

Blood Flow Simulation in Bifurcated Geometry of Abdominal and Iliac Arteries Based on CT Images (CT영상에 기반한 복부대동맥과 장골동맥 분기관 모델의 혈류유동 해석)

  • Hong Y. S.;Kim M. C.;Kang H. M.;Lee C. S.;Kim C. J.;Lee J. M.;Kim D. S.;Lee K.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.497-503
    • /
    • 2004
  • Numerical simulation of blood flow has been conducted based on real vessel geometries generated front DICOM medical images of abdominal and iliac bifurcated arteries of a healthy man. A program was developed to read cross sectional images of the three dimensional arteries and smoothly extract boundary coordinates of vessels. Commercial programs were employed for mesh generation and flow simulation. Pressures, velocities, and flow distributions were found to lie within normal physiological ranges. Peak velocity measured in the iliac artery by ultrasound was 20% smaller than that obtained by simulation. The trend of velocity variation in a cardiac cycle was fairly similar between the simulation and the ultrasonic measurements. Simulation based on real vessel geometry of individual patient provides information on pressure, velocity, and its distribution in the diseased arteries or arteries to be surgically treated. The results of simulation may help surgeons to better understand hemodynamic status and surgical need of the patient by revealing variation of the hemodynamic parameters. Futhermore, they may serve as basic data for surgical treatment of arteries. This research is expected to develop to a program in the future that early diagnose atherosclerosis by showing distribution of a hemodynamic index closely related to atherosclerosis in arteries.

Intra-aortic Balloon Pump Therapy for Hemodynamic Instability during Off-pump Coronary Artery Bypass Surgery (심폐바이패스를 사용하지 않는 관상동맥우회술 중 발생한 혈역학적 불안정에 대한 대동맥내 풍선펌프 치료)

  • Jeong, Dong-Seop;Kim, Ki-Bong;Choi, Eun-Seok
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.704-709
    • /
    • 2009
  • Background: We assessed the efficacy of intraoperative intra-aortic balloon pump therapy for achieving hemodynamic instability during off-pump coronary artery bypass surgery. Material and Method: We studied seven hundred ninety-six patients who underwent off-pump coronary artery bypass between January 2000 and December 2006. The patient were divided into group I (n=39), which received intraoperative intra-aortic balloon pump therapy, and group II (n=757), which did not receive intraoperative intra-aortic balloon pump therapy. Result: There were no differences in the operative mortalities (2.6%, 1/39 vs 0.8%, 6/757; p=0.195) and morbidities such as atrial fibrillation (p=0.691), stroke (p=0.908) and mediastinitis (p=0.781) between the 2 groups, although the ventilator support time, the length of the intensive care unit stay and the length of the hospital stay were longer in group I than in group II (p<0.05). Multivariate analysis failed to prove that group I was a high risk group for operative mortality (p=0.549). There were 3 intraoperative intra-aortic balloon pump-related complications in group I (7.9%). However, no longer complications occurred after 2003, when the surgeons began using a smaller sized 8 F catheter that was inserted using a sheathless technique. Conclusion: Intraoperative intra-aortic balloon pump therapy for achieving hemodynamic instability during off-pump coronary artery bypass surgery can be performed safely and it showed comparable clinical results to that of not using intraoperative intra-aortic balloon pump therapy.

Development and in Vivo Test of an Electrohydraulic Total Artificial Heart at the National Cardiovascular Center in Japan (일본 국립 순환기 센타형 전기유압식 인공심장의 개발과 동물실험)

  • 손영상
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.163-170
    • /
    • 1998
  • The ultimate goal of total artificial heart is permanent substitute for a failed heart in a patient without any other therapeutic modality. Until now, infection has been the main problem related to the mechanical circulatory support system. The best way to solve this catastrophic complication and to improve the quality of life of TAH patients in terms of tethering must be implantation of TAH totally. The EH-TAH has been developed in NCVC from 1987 for this purpose. The system consists of an energy converter and pumps, which are designed to be placed in abdomen and pericardial space separately for a good anatomical fit. To evaluate the anatomical fit and hemodynamic performance of the EH-TAH, in vivo test was done. General condition of the animal and hemodynamic status had been stable until the TAH stopped on the 11th pumping day. The estimated cardiac output was about 7.7L/min. The values of mean aortic pressure, left and right atrial pressure were 93$\pm$10, 19$\pm$3 and 15$\pm$4 mmHg, respectively. The correlation coefficient between left and right atrial pressure was 0.96, which represents the dynamic function of the interatrial shunt in controlling left-right imbalance of cardiac output. During pumping days, the temperature on the surface of actuator had been maintained at 39.7$\pm$0.4$^{\circ}C$, less than 1$^{\circ}C$ higher than the rectal temperature. The TAH stopped on the 11th day due to mechanical problems. We concluded that the EH-TAH possessed satisfactory basic performance including anatomic fit and hemodynamic adequacy, although there were several mechanical problems to be solved yet.

  • PDF

Application of Near-Infrared Spectroscopy in Neurological Disorders: Especially in Orthostatic Intolerance (신경계 질환에서 근적외선분광분석법의 적용: 기립불내증을 중심으로)

  • Kim, Yoo Hwan;Paik, Seung-ho;Phillips V, Zephaniah;Seok, Hung Youl;Jeon, Nam-Joon;Kim, Beop-Min;Kim, Byung-Jo
    • Journal of the Korean neurological association
    • /
    • v.35 no.1
    • /
    • pp.8-15
    • /
    • 2017
  • Near-infrared spectroscopy (NIRS), a noninvasive optical method, utilizes the characteristic absorption spectra of hemoglobin in the near-infrared range to provide information on cerebral hemodynamic changes in various clinical situations. NIRS monitoring have been used mainly to detect reduced perfusion of the brain during orthostatic stress for three common forms of orthostatic intolerance (OI); orthostatic hypotension, neurally mediated syncope, and postural orthostatic tachycardia syndrome. Autonomic function testing is an important diagnostic test to assess their autonomic nervous systems for patients with symptom of OI. However, these techniques cannot measure dynamic changes in cerebral blood flow. There are many experimentations about study of NIRS to reveal the pathophysiology of patients with OI. Research using NIRS in other neurologic diseases (stroke, epilepsy and migraine) are ongoing. NIRS have been experimentally used in all stages of stroke and may complement the established diagnostic and monitoring tools. NIRS also provide pathophysiological approach during rehabilitation and secondary prevention of stroke. The hemodynamic response to seizure has long been a topic for discussion in association with the neuronal damage resulting from convulsion. One critical issue when unpredictable events are to be detected is how continuous NIRS data are analyzed. Besides, NIRS studies targeting pathophysiological aspects of migraine may contribute to a deeper understanding of mechanisms relating to aura of migraine. NIRS monitoring may play an important role to trend regional hemodynamic distribution of flow in real time and also highlights the pathophysiology and management of not only patients with OI symptoms but also those with various neurologic diseases.