• Title/Summary/Keyword: Hemodialysis system

Search Result 45, Processing Time 0.019 seconds

The Development of patient classification system for hemodialysis (혈액투석환자 중증도 분류체계 개발)

  • Kim, Moon-Sil;Yoon, Ji-Sook
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.8 no.4
    • /
    • pp.633-643
    • /
    • 2002
  • Purpose : This study was conducted to develop a patient classification system for hemodialysis and to test its validity and reliability. Method : The process of the system development was as below. The lists of hemodialysis nursing activities were collected from literature and hemodialysis practice guideline and they were classified into 10 factors and 16 elements. And then, 4 classification levels were identified for each element. The content validity and interrater reliability of developed patient classification system were tested. Result & Conclusion : 10 factors of patient classification system for hemodialysis were consisted of psychosocial support, mobility, access, teaching, assessment, stability, supportive therapy, test, general nursing during hemodialysis, hemodialysis room management. According to validity and reliability results and experts' opinions, 4 classification levels revised to 3 classification levels and 2 elements were deleted. Finally, patient classification system were consisted of 10 factors, 14 elements, 3 classification levels, 3 categories.

  • PDF

Simulation of Cardiovascular System for an Optimal Sodium Profiling in Hemodialysis

  • Lim, K.M.;Min, B.G.;Shim, E.B.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.2 no.2
    • /
    • pp.16-26
    • /
    • 2004
  • The object of this study is to develop a mathematical model of the hemodialysis system including the mechanism of solute kinetics, water exchange and also cardiovascular dynamics. The cardiovascular system model used in this study simulates the short-term transient and steady-state hemodynamic responses such as hypotension and disequilibrium syndrome (which are main complications to hemodialysis patients) during hemodialysis. It consists of a 12 lumped-parameter representation of the cardiovascular circulation connected to set-point models of the arterial baroreflexes, a kinetic model (hemodialysis system model) with 3 compartmental body fluids and 2 compartmental solutes. We formulate mathematically this model in terms of an electric analog model. All resistors and most capacitors are assumed to be linear. The control mechanisms are mediated by the information detected from arterial pressoreceptors, and they work on systemic arterial resistance, heart rate, and systemic venous unstressed volume. The hemodialysis model includes the dynamics of urea, creatinine, sodium and potassium in the intracellular and extracellular pools as well as fluid balance equations for the intracellular, interstitial, and plasma volumes. Model parameters are largely based on literature values. We have presented the results on the simulations performed by changing some model parameters with respect to their basal values. In each case, the percentage changes of each compartmental pressure, heart rate (HR), total systemic resistance (TSR), ventricular compliance, zero pressure filling volume and solute concentration profiles are represented during hemodialysis.

  • PDF

Application of Pediatric Hemodialysis System to Experimental Renal Failure in Dogs (실험적으로 유발한 신부전 개에서 소아용 혈액투석기의 적용에 관한 연구)

  • 신현호;김완희;이충호;남치주;권오경
    • Journal of Veterinary Clinics
    • /
    • v.17 no.2
    • /
    • pp.340-345
    • /
    • 2000
  • The purpose of the present study was to evaluate the possibility of application of pediatric hemodialysis system to dogs weighing less than 6 kg. Six healthy dogs (B .W, 3-6 kg) were used_ Experimental end-stage renal failure was induced by bilateral nephrectomy or bilateral ligation of ure-ters. Hemodialysis was performed when blood urea nitrogen (BUN) value increased over 90 mg/dl and every other day thereafter. Daily investigated parameters included clinical clinical signs such as vomiting, fecal appearance and activity and laboratory data such as PCV, WBC, RBC, BUN, creatinine, Ca, P, $Na^+ Cl^-and K^+$During hemodialysis treatment, BUN and creatinine values were measured hourly. Severe vomiting and inappetence were shown 2 days after infliction of kidney disorder and melena and mucous faces were observed 3 days. The signs were not corrected by hemodialysis treatment. Avel- age hemodialysis treatment time was $5.5 {\times} 0.7$,/TEX> hours until BUN value decreased to normal range. Abnor- mal hematological and electrolytes values were reduced within normal levels after hemodialysis treatments. The complications oft hemodialysis included vomiting, nausea, obstruction of intravascular catheter, tremor, seizure, temporary visual loss and continued decrease in PCV It is suggested that pediatric hemedialysis system can be applied to acute renal failure and acute toxicity. Further works on improvements in maintaining patency of catheter and in managing the complications of hemo- dialysis should be conducted.

  • PDF

The Development of Hemodialysis System Based on Embedded System (임베디드 시스템 기반의 혈액 투석기 시스템의 개발)

  • Ji, Jung-Ho;Lee, Kyoung-Joung;Kim, Young-Ho;Park, Kwang-Li
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.11
    • /
    • pp.521-527
    • /
    • 2002
  • The Hemodialysis system is the device for the patients who have suffered from end stage renal failure as the kidney which removes the waste products in a human body. The existing hemodialysis is based on a 8-bit micro-controller and it is not a touch-screen type but a manual type. This paper is focused on hemodialysis system based on high control and expension embedded system. The whole system consists of main control unit and sub control unit(dialysis control unit, blood control unit, monitoring control unit, networking unit). The dialysis control unit, blood control unit, monitoring control unit are processed by 3 microcontrollers and network unit is for monitoring a renal failure patient's condition. For the evaluation of the system performance, the saline was pured into blood unit and then water removal rate, conductivity and temperature of hemodialysis liquid were measured 10 times in an each state suing the UF pump in the fluid unit varing the quantity of saline to 1000cc, 2000cc, 3000cc and 4000cc. As a result, the rates of water removal are 98.6% in condition of 000cc saline, 96.9% in 2000cc, 98.9% in 3000cc and 98.3% in 4000cc. The conductivities of hemodialysis liquid are 99.6% in the first to third condition and 99.7% in the forth condition. The temperatures of hemodialysis liquid are 99.8% in the first to third condition and 99.6% in th forth condition.

Association of Hemodialysis and Sarcopenia : A systematic review (혈액투석과 근감소증의 연관성에 관한 문헌고찰)

  • Kyoung-Wook Choi;Hwa-Gyeong Lee;Soo-Ah Kim;Yun-Jae Oh
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.3
    • /
    • pp.185-194
    • /
    • 2023
  • Purpose : This study aimed to investigate the relationship between the characteristics of hemodialysis patients and the occurrence of sarcopenia through a comprehensive literature review. Methods : A systematic literature search was conducted to identify eligible studies in the Cochrane library, PubMed and Embase. In this review, we included all papers published since the initiative's inception and summarized results as of december 2022. Studies that investigated association between sarcopenia diagnosis and hemodialysis patients (aged≥18 years) were included. Ultimately, 16 studies met our selection criteria. The risk of bias was assessed using the Newcastle-Ottawa scale. Results : Fourteen of the sixteen studies (88 %) reported that significant association between sarcopenia diagnosis and hemodialysis patients. However, two studies reported no association between sarcopenia diagnosis and hemodialysis patients. As a factor statistically related to sarcopenia in hemodialysis patients, Mortality (6 studies, 38 %), age (5 studies, 31 %), body composition (4 studies, 25 %), physical activity (2 studies, 13 %), diabetes (2 studies, 13 %), cardiovascular abnormalities (1 studies, 6 %), nutritional status (3 studies, 19 %), and gender (3 studies, 19 %). Conclusion : Our findings highlight the necessity of developing a physical therapy program that accurately reflects the health status of hemodialysis patients. To further investigate the association between the diagnosis of sarcopenia and hemodialysis patients, it is recommended to conduct large-scale longitudinal studies using standardized diagnostic criteria and evaluation methods, as well as analyze potential risk factors. Consequently, this study emphasizes the importance and potential of developing physical therapy programs that effectively address the health consequences associated with hemodialysis. The significance of this research lies in its ability to provide valuable insights and lay the foundation for future studies focused on developing preventive and therapeutic interventions targeting muscle wasting syndrome resulting from hemodialysis.

Prevalence of Musculoskeletal Pain in Patients With End-Stage Renal Failure Receiving Hemodialysis (말기 신부전 환자의 근골격계 통증 발생 실태 -혈액투석 환자를 대상으로-)

  • Park, Hee-Jung;Kim, Suhn-Yeop
    • Journal of Korean Physical Therapy Science
    • /
    • v.17 no.3_4
    • /
    • pp.1-9
    • /
    • 2010
  • Purpose: The objectives of this study were to investigate the current status of the pain in and the dysfunction related to the musculoskeletal system experienced by patients with end-stage renal failure receiving hemodialysis. Methods: A questionnaire survey was given to 107 patients undergoing hemodialysis in M Hospital. The survey was conducted by using a brief pain inventory(BPI) to investigate the body parts in pain, degree of pain, difficulty in daily life, correlation with hemodialysis and the degree of satisfaction with their own health. Results: The investigation of the patients undergoing hemodialysis showed that 89(83.2%) of the 107 patients experienced pain in their musculoskeletal system. Their pain's incidence was highest in the knees(46.1%) and 68.5% of the patients reported that the most severe pain they had experienced within the past 24 hours was at a level between "moderate" and "severe." The limitation of daily life by pain is high most as 47.7% in the accomplishment of works. Conclusion: Most hemodialysis patients experience musculoskeletal related pain that affects their daily life. Hemodialysis patient management programs should include an assessment and management of such pain.

  • PDF

The Experience of Fluid Management in Hemodialysis Patients (혈액투석 환자의 수액관리 경험)

  • Kim, Yoonsoo;Kim, Miyoung
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.5
    • /
    • pp.773-782
    • /
    • 2015
  • Purpose: The purpose of this study was to explore the experience of fluid management in hemodialysis patients by describing how they manage fluid intake and what affects fluid management. Methods: Purposive sampling yielded 11 patients who have received hemodialysis for one year or longer in one general hospital. Data were collected through in-depth interviews and analysed using Giorgi's phenomenological method. Data collection and analysis were performed concurrently. Results: The findings regarding how hemodialysis patients manage fluid intake were classified into four constituents: 'recognizing the need for fluid control', 'observing the status of fluid accumulation', 'controlling fluid intake and output', 'getting used to fluid management'. The factors that affect fluid management of hemodialysis patients were revealed as 'willpower', 'change in the mindset', 'support system', and 'emotional state'. Conclusion: The study results show that hemodialysis patients manage fluid intake through food and exercise as well as interpersonal relationships. These findings suggest that strategies in the development of nursing interventions for hemodialysis patients should be directed at assisting them in familiarization with fluid management based on an understanding of their sociocultural contexts.

Effect of Dialysis Nurses' Perception of Patient Safety Risk Factors and Patient Safety Competency on Safety Nursing Activities (혈액투석실 간호사의 환자안전에 대한 위험요인 인식과 역량이 안전간호활동에 미치는 영향)

  • Lee, Jae Jung;Jeon, Mi Yang;Lee, Jung Ja;Kim, Gha Na;Jeong, Da In
    • Journal of Korean Clinical Nursing Research
    • /
    • v.27 no.2
    • /
    • pp.210-219
    • /
    • 2021
  • Purpose: The study was conducted to investigate the correlation between perception of patient safety risk factors, patient safety competency, and safety nursing activities of nurses in hemodialysis units and identify factors affecting patient safety activities. Methods: The participants were 146 nurses from 16 hemodialysis units located in Gyeongsangnam-do. Data were analyzed using descriptive statistics, independent t-test, one-way ANOVA, Pearson correlation coefficient, and multiple regression analysis using the SPSS, version 24.0. Results: The mean safety nursing activity score was 3.47±0.38. safety nursing activities of the participants were significantly correlated with patient safety competency. The characteristics showing significant differences in safety nursing activities were educational level, hospital type, hospital work experience, number of hemodialysis treatment per day, number of hemodialysis treatment per nurse, educational experience of patient safety, presence of a patient safety incident report registration system, and direct registration of patient safety incident report. The multiple regression analysis revealed that the factors influencing safety nursing activities were patient safety incident report, patient safety competency, and number of daily hemodialysis treatment (<5~7 times/day) per nurse (R2=.34). Conclusion: The results of this study suggest that the safety nursing activities of hemodialysis unit nurses should be intensified. In addition, the registration system of patient safety incident report and nurses' competency on patient safety should be improved, and the number of hemodialysis per nurse should be fewer than 7 times per day.

Adaptation Process of The Family with Hemodialysis (혈액투석 환자 가족의 적응 과정)

  • Lee, Young-Ae
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.2 no.2
    • /
    • pp.184-192
    • /
    • 1999
  • Hemodialysis is a way of treatment for the patients with acute and chronic renal failure. "Marginal man" depicts the enormous amount of stress that hemodialytic patients suffer. It is known that family with chronic illness get stressed along with the patients and they need nursing care also. This qualitative study was conducted in order to identify the family adaptation process in patients with hemodialysis. 6 dyads of hemodialytic patients and caregivers were interviewed for this research. By way of grounded theoretical strategy the data was collected from October 20, 1999 to November 20, 1999. at a hemodialytic unit that was located in Iksan, Chonbuk by the researcher. The main research questions were "What's the adaptation experience of a patient since after being received with hemodialysis?" to the patients, and "What's the family adaptation experience of hemodialysis?" to the caregivers. The collected data was analyzed by grounded theoretical strategy built by Glaser & Strauss in 1967. Results were as follows; 7 grounded concepts were observed from the patients with hemodialysis and 4 grounded concepts were found from the caregivers. Two categories were derived ; 1) Holding hope that is related with treatment 2) Changing a value system.

  • PDF

Design of An Autobalancing System for Hemodiafiltration (인공신장투석여과기용 자동밸런스 장치의 설계)

  • 이병채;이효철;이명호
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.11
    • /
    • pp.47-55
    • /
    • 1993
  • This paper is to design an autobalancing system based-on microprocessor for hemodiafiltration (HDF) system. The proposed system consist of motor control part, thermostatic control part, alarm system and electronic scale which ar automatically controlled by microprocessor. Conventional hemodialysis system can not remove medium molecular articles but hemodialysis system with the proposed system can remove and infuse substitute to the patient. This system can be easily interfaced with any other conventional HD system. The results obtained from performance evaluation of the proposed system are suitable for clinical supporting system.

  • PDF