• 제목/요약/키워드: Hemiplegic gait

검색결과 137건 처리시간 0.021초

골반운동이 뇌졸중 환자의 보행특성에 마치는 효과 (A Study on the Effect of Pelvic Tilting Exercise in Hemiplegic Patients)

  • 이정원
    • 한국전문물리치료학회지
    • /
    • 제5권2호
    • /
    • pp.23-38
    • /
    • 1998
  • The objective of this study was to identify the effects of pelvic tilting exercise on gait patterns of hemiplegic patients. The subjects of this study were 31 hemiplegic in- and out-patients of the Rehabilitation Hospital, Yonsei University Medical Center, from September 24, 1997 through November 5, 1997. Pre- and post-treatment change in gait patterns were measured using a ink foot-print. The data were analyzed by the paired t-test, one-way ANOVA, and independent t-test. The findings were as follows: The difference in gait patterns between pre- and post-treatment was statistically significant, with an increase in gait velocity to 7.98 cm/sec post-treatment; an increase in cadence to 7.29 steps/min; a narrowing of the base of support to 1.33 cm; an increase in step length of 3.92 cm on the less affected side and 3.73 cm on the more affected side; an increase in stride length of 5.82 cm on the less affected side and 5.92 cm on the more affected side(statistically not significant in foot angle). In relation to sex, age, cause of stroke, and laterality of paralysis, the difference in gait patterns between pre- and post-treatment was not statistically significant. Where there was no significant difference of the effects of pelvic exercise regarding the degree of spasticity, the presence of a decrease in proprioception, and the duration of treatment. In conclusion, hemiplegic pelvic tilting exercise was found to have transmitting positive effect in improving gait patterns.

  • PDF

편마비 보행 :속도에 따른 관절 운동학적 변수 비교 (Hemiplegic gait : comparison of kinematic variables related to Bait speed)

  • 권영실;최진호;정병옥;채윤원;김진상
    • The Journal of Korean Physical Therapy
    • /
    • 제11권1호
    • /
    • pp.95-102
    • /
    • 1999
  • In hemiplegic gait, walking speed is an important factor to evaluate treatment effect. The purpose of this study was to describe and compare kinematic variables during differant speed hemiplegic gaits. Six hemiplegic patients(47-69 years old) after stroke and age - matched six volunteers in good health(51-61 years old) were studied. The patients were sorted into two groups, depending on their self - speed of walking : fast speed group(3 patients, $0.74\pm0.14m/s$) and slow speed group(3 patients, $0.29\pm0.09m/s)$. The results were following. 1. In the hip joint, the fast group had lower mean value than normal but had similar pattern to normal. The slow group had continuous flexed pattern. 2. In the knee joint, the fast group had similar mean value and pattern to normal. The slow group had continuous flexed pattern. 3. In the ankle joint, the two group had dorsiflexed pattern. The fast group had similar pattern to normal. Thus, the fast group was similar gait pattern to normal.

  • PDF

직선 및 회전 보행 시 편마비에 따른 고령자의 보행 특성 변화 (Alteration of Gait Characteristics in Hemiplegic Elderly during Straight and Revolution Gaits)

  • 정호현;이범기;전경진;임도형
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권2호
    • /
    • pp.26-34
    • /
    • 2014
  • Little information is available about the characteristics in revolution gait of hemiplegic elderly, which is frequently represented in daily life. It is also hard to elucidate purely the characteristics due to hemiplegia because of no consideration of aging factors. The aim of study is to identify the alteration characteristics of lower extremity joint angles in both straight and revolution gaits together due to hemiplegia through comparing healthy with hemiplegic elderly. Following Institutional Review Board approval, twelve healthy and hemiplegic elderly were participated and the center of body mass (COM) and lower extremity joint angles were measured during straight and revolution gaits using a computer-aided video motion capture system. The results showed that the gait characteristics were generally altered in both straight and revolution gaits due to hemiplegia (p < 0.05). The gait characteristics were then different between the straight and revolution gaits each other. This study may be valuable by identifying for the first time the alterations of the lower extremity joint angles in both straight and revolution gaits due to pure hemiplegia through comparing healthy elderly with hemiplegic elderly.

뇌졸중 환자에서 보행의 시공간적 특징 (Spatiotemporal characteristics of stroke patients gait)

  • 이상관;최산호;오재건;이일석;박기언;홍해진;성강경
    • 대한중풍순환신경학회지
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 2013
  • The following study reviewed the walking patterns of stroke patients with hemiplegia, which is called hemiplegic gait of stroke patients. Focusing is given to the changes in the distance and temporal factors of walking, which is called spatiotemporal characteristics, throughout the walking cycle. First, we introduced the definitions of essential terms related to gait and its measure. Second, we reviewed the spatiotemporal characteristics of hemiplegic gait. A main issue was that hemiplegic gait showed significant deviations from normal healthy gait. Although hemiplegia is primarily associated with unilateral motor disorder, changes in almost all spatiotemporal parameters used to assess walking were evident on both the involved and uninvolved sides of the body. Last, we reviewed the changes of spatiotemporal parameters of hemiplegic gait according to the prognosis or status of stroke patients, which may help to give a specific intervention for rehabilitation of stroke.

  • PDF

Development of a Portable Gait Phase Detection System for Patients with Gait Disorders

  • Ahn Seung Chan;Hwang Sung Jae;Kang Sung Jae;Kim Young Ho
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권3호
    • /
    • pp.145-150
    • /
    • 2005
  • A new gait detection system using both FSR (force sensing resistor) sensors and a gyrosensor was developed to detect various gait patterns. FSR sensors were put in self-designed shoe insoles and a gyrosensor was attached to the heel of a shoe. An algorithm was also developed to determine eight different gait transitions during four gait phases: heel-strike, foot-flat, heel-off and swing. The developed system was evaluated from nine heathy mans and twelve hemiplegic patients. Healthy volunteers were asked to walk in various gait patterns: level walking, fore-foot walking and stair walking. Only the level walking was performed in hemiplegic patients. The gait detection system was compared with a optical motion analysis system and the outputs of the FSR sensors. In healthy subjects, the developed system detected successfully more than $99\%$ for both level walking and fore-foot walking. For stair walking, the successful detection rate of the system was above$97\%$. In hemiplegic patients, the developed system detected approximately 98% of gait transitions. The developed gait phase detection system will be helpful not only to determine pathological gait phases but also to apply prosthetics, orthotics and functional electrical stimulation for patients with various gait disorders.

보행주기 검출용 모션 센서 시스템의 비교 (Comparison of Motion Sensor Systems for Gait Phase Detection)

  • 박선우;손량희;류기홍;김영호
    • 한국정밀공학회지
    • /
    • 제27권2호
    • /
    • pp.145-152
    • /
    • 2010
  • Gait phase detection is important for evaluating the recovery of gait ability in patients with paralysis, and for determining the stimulation timing in FES walking. In this study, three different motion sensors(tilt sensor, gyrosensor and accelerometer) were used to detect gait events(heel strike, HS; toe off, TO) and they were compared one another to determine the most applicable sensor for gait phase detection. Motion sensors were attached on the shank and heel of subjects. Gait phases determined by the characteristics of each sensor's signal were compared with those from FVA. Gait phase detections using three different motion sensors were valid, since they all have reliabilities more than 95%, when compared with FVA. HS and TO were determined by both FVA and motion sensor signals, and the accuracy of detecting HS and TO with motion sensors were assessed by the time differences between FVA and motion sensors. Results show of that the tilt sensor and the gyrosensor could detect gait phase more accurately in normal subjects. Vertical acceleration from the accelerometer could detect HS most accurately in hemiplegic patient group A. The gyrosensor could detect HS and TO most accurately in hemiplegic patient group A and B. Valid error ranges of HS and TO were determined by 3.9 % and 13.6 % in normal subjects, respectively. The detection of TO from all sensor signals was valid in both patient group A and B. However, the vertical acceleration detected HS validly in patient group A and the gyrosensor detected HS validly in patient group B. We could determine the most applicable motion sensors to detect gait phases in hemiplegic patients. However, since hemiplegic patients have much different gait patterns one another, further experimental studies using various simple motion sensors would be required to determine gait events in pathologic gaits.

만성 뇌졸중 환자의 보행에 보행보조기가 미치는 영향 (The Effect of Walking Aid on Chronic Hemiplegic Gait)

  • 김원호
    • 한국전문물리치료학회지
    • /
    • 제13권3호
    • /
    • pp.67-74
    • /
    • 2006
  • The purpose of this study was to investigate the effects of walking aid on hemiplegic gait of chronic stroke patients. Twelve stroke patients participated in this study. Physiological cost index (PCI), gait speed, and climbing stairs with and without walking aid were measured and analyzed. The results showed that walking with walking aid significantly improved gait speed and reduced physiological cost index and time needed to climb stair (height 7 cm) in comparison with a walking without walking aid. In conclusion, walking aid may improve the speed and efficiency of hemiplegic gait in chronic stroke patients.

  • PDF

편마비 환자의 단하지 보조기 착용유무에 따른 하지 체중지지율과 보행특성의 변화에 관한 연구 (A study on the immediate effects of weight distribution and gait patterns of hemiplegic patients through PLS on and off)

  • 김택훈;구애련;김종만
    • 한국전문물리치료학회지
    • /
    • 제3권2호
    • /
    • pp.55-76
    • /
    • 1996
  • The objective of this study was to identify the immediate effects of the short leg brace on the weight bearing distribution and gait patterns of hemiplegic patients. The subjects of this study were 18 hemiplegic patients who had been hospitalized or visited out-patient department of Rehabilitation Hospital, Yonsei University College of Medicine, from January 5, 1996 through March 23, 1996. PLS(Posterior Leaf Spring) on and off changes in gait patterns were measured using ink foot print as well as by recording weight bearing distribution using a limb load monitor. The data were analyzed by the correlation and paired t-test. The findings were as follows: 1. Eighteen subjects were more weighted on the affected leg when PLS was put off(42.74%) than on(40.08%). 2. The defference in gait patterns between PLS on and off was statistically significant, with an increase in step length by 1.7cm on the involved side; a decrease in foot angle by 4.41 degree on the involved side; and a narrowing of base of support by 1.46cm when PLS were off. In conclusion, this study showed that PLS did not affect the weight bearing distribution and gait patterns of hemiplegic patients. Since, the evaluation method used in this study has limitations in regard to temporal distance gait values. Further studies are required to numerous experiments for subject and extensive study.

  • PDF

보바스치료와 일반적치료가 성인 편마비 환자의 보행능력에 미치는 영향 (The Effect of Bobath and Conventional Method in Gate of Adult Hemiplegic Patients)

  • 이근희;김형수;한동욱;김병조
    • 대한물리의학회지
    • /
    • 제3권4호
    • /
    • pp.277-284
    • /
    • 2008
  • Purpose : The purpose of this study was to identify the influence of Bobath and conventional method has an effect on gait of adult hemiplegic patients. Methods : The data were collected by each 15 adult stroke patients. The treatment was based on Bobath and conventional approach. Temporal and spatial parameters of gait were analysed for using the computerized GAITRite system. Results : The gait step (p<.05), gait velocity (p<.05), cadence (p<.05) and step length (p<.05) was significantly different with the Bobath method. The Gait step (p<.05) and gait velocity (p<.05) was significantly different with the conventional method. But the cadence and step length was not significantly increased in the conventional method. Conclusion : The Bobath method is more useful to improve the gait in hemiplegic patients than conventional method.

  • PDF

고유수용성신경근촉진법이 편마비 환자의 보행능력에 미치는 영향 (The Effects of Proprioceptive Neuromuscular Facilitation on Gait Ability in Hemiplegic Patients)

  • 황인걸;한미란;손경현;임재헌;이문규
    • PNF and Movement
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 2009
  • Purpose : The aim of this study was to determine the effect of Proprioceptive Neuromuscular Facilitation (PNF) on gait ability in hemiplegic patients. Method : The subjects of this study were 11 hemiplegic patients. Each subject was taken PNF exercise with 3 times per week for 4 weeks. Pre- and post-intervention change in gait ability were measured using an 6m walking test, stride length, and step length. The data were analyzed using the paired t-test. Results : The results of this study showed significantly improvement in 6m walking test, stride length, and step length after intervention. Conclusion : These results suggest that the PNF coordination exercise is an effective way of improving gait ability for hemiplegic patients.

  • PDF