• 제목/요약/키워드: Helium gas

검색결과 315건 처리시간 0.022초

30(kVA) 초전도발전기 제작 및 특성 (Fabrication and Characteristics of 30〔kVA〕 Superconducting Generator)

  • 손명환;권영길;백승규;박도영;이언용;조영식;류강식
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권2호
    • /
    • pp.32-38
    • /
    • 2001
  • A 30[kVA] superconducting generator (SCG) is built and tested at Korea Electrotechnology Research Institute (KERI) in Korea. This superconducting generator has an air-gap winding instead of the typical steel teeth structure. The rotor has 4 field coils of race-track type with NbTi superconducting wired. The rotor is composed of two dampers and a liquid helium composed of two dampers and a liquid helium container in which the field poles reside. The space between the outermost damper and the container is vacuum insulated. A ferrofluid seal is used between the stationary part connected to the couping and the rotor. A helium transfer coupling(HTC) has 3 passages of the recovered heilum gas and a gas flow control system. The open circuit test and sustained short circuit test are preformed to obtain the open circuit characteristics (OCC) and short circuit characteristics (SCC) Also. the test results usder the light load (up to 3.6[kW]) are given. The structure, manufacturing and basis test of the 30[kVA]SCG are discussed.

  • PDF

Effect of a Series Connection of a Bi-Electrolyte Hydrogen Sensor in a Leak Detector

  • Han, Hyeuk Jin;Park, Chong Ook;Hong, Youngkyu;Kim, Jong Suk;Yang, Jeong Woo;Kim, Yoon Seo
    • 센서학회지
    • /
    • 제24권1호
    • /
    • pp.6-9
    • /
    • 2015
  • Conventional leak detectors are widely based on helium gas sensors. However, the usage of hydrogen sensors in leak detectors has increased because of the high prices of helium leak detectors and the dearth in the supply of helium gas. In this study, a hydrogen leak detector was developed using solid-state hydrogen sensors. The hydrogen sensors are based on Park-Rapp probes with heterojunctions made by oxygen-ion conducting Yttria-stabilized zirconia and proton-conducting In-doped $CaZrO_3$. The hydrogen sensors were used for determining the potential difference between air and air balanced 5 ppm of $H_2$. Even though the Park-Rapp probe shows an excellent selectivity for hydrogen, the sensitivity of the sensor was low because of the low concentration of hydrogen, and the oxygen on the surface of the sensor. In order to increase the sensitivity of the sensor, the sensors were connected in series by Pt wires to increase the potential difference. The sensors were tested at temperatures ranging from $500-600^{\circ}C$.

헬륨가스 분사에 의한 액체질소 냉각에 관한 연구

  • 정용갑;조남경;길경섭;송이화;김유;조광래
    • 항공우주기술
    • /
    • 제3권1호
    • /
    • pp.205-212
    • /
    • 2004
  • 본 연구에서는 액체로켓의 극저온 추진제 공급부에서 요구되는 추진제의 공급 온도를 맞추기 위한 헬륨 가스 분사 냉각에 대한 수류 실험을 수행하여, 헬륨가스 분사에 의한 온도 저감에 대한 실험적 연구를 통한 온도 저감 특성을 고찰하였다. 수류 실험에 사용된 극저온 액체는 액체 질소를 사용하였으며, 냉각을 위한 가스로는 헬륨가스를 사용하였다. 헬륨 분사에 의한 액체 질소 과냉각 현상을 확인할 수 있었으며, v/vL≒0.8min-¹ 조건에서 대략 4분 이내에 최대로 과냉각(subcooling)됨을 알 수 있었다.

  • PDF

기체공급계 재순환배관의 성능시험 및 계산 (Performance Test and Calculation of Recirculation Line in Propellant Feeding System)

  • 권오성;조남경;정용갑;한상엽;김영목
    • 한국추진공학회지
    • /
    • 제11권2호
    • /
    • pp.9-17
    • /
    • 2007
  • 기체공급계 추진제공급시스템의 재순환배관에 대하여 성능시험을 수행하였다. 극저온 추진제로 액체 산소를 사용하고 재순환촉진용 분사가스로는 헬륨을 사용하여 탱크 얼리지가 대기압 상태인 경우와 4 bars로 가압된 경우에 대하여 시험하였다. 자연재순환의 발생여부와 헬륨분사량에 따른 액체산소의 재순환량 변화 및 배관 내부 온도분포를 파악하였고, 주어진 규격의 배관시스템에 대한 적정 헬륨분사량과 터보펌프 전단의 추진제 온도상승 정도를 살펴보았다. 시험데이터를 이용하여 재순환배관의 성능계산을 위한 프로그램을 작성하고 시험과 계산결과를 비교하였다.

Evaluation Method on Destruction and Removal Efficiency of Perfluorocompounds from Semiconductor and Display Manufacturing

  • Lee, Jee-Yon;Lee, Jin-Bok;Moon, Dong-Min;Souk, Jun-Hyung;Lee, Seung-Yeon;Kim, Jin-Seog
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권8호
    • /
    • pp.1383-1388
    • /
    • 2007
  • Recently, the semiconductor and display industries have tried to reduce the emissions of perfluorocompounds (PFCs) from the globally environmental regulation. Total amount of PFC emission can be calculated from the flow rate and the partial pressures of PFCs. For the precise measurement of PFC emission amount, the mass flow controlled helium gas was continuously injected into the equipment of which scrubber efficiency is being measured. The partial pressures of PFCs and helium were accurately measured using a mass spectrometer in each sample extracted from inlet and outlet of the scrubber system. The flow rates are calculated from the partial pressures of helium and also, PFC destruction and removal efficiency (DRE) of the scrubber is calculated from the partial pressure of PFC and the flow rate. Under this method, the relative expanded uncertainties of the flow rate and the partial pressures of PFCs are ± 2% (k = 2) in case the concentrations of NF3 and SF6 are as low as 100 μmol/mol.

CFD Analysis of Natural Convection Flow Characteristics of Various Gases in the Spent Fuel Dry Storage System

  • Shin, Doyoung;Jeong, Uiju;Jeun, Gyoodong;Kim, Sung Joong
    • 한국유체기계학회 논문집
    • /
    • 제19권4호
    • /
    • pp.19-28
    • /
    • 2016
  • Objective of this study is to compare the inherent characteristics of natural convection flow inside the canister of spent fuel dry storage system with different backfill gases by utilizing computational fluid dynamics (CFD) code. Four working fluids were selected for comparison study. Helium currently used backfill gas for canister, air, nitrogen, and argon are frequently used as coolant in many heat transfer applications. The results indicate that helium has very distinct conductive behavior and show very weak natural convective flow compared to the others. Argon showed the strongest natural convective flow but also the worst coolability. Air and nitrogen showed similar characteristics to each other. However, due to difference in Prandtl number, nitrogen showed more effective natural convective flow. These results suggest that experimental validation for the nitrogen is needed to investigate the potential coolability other than currently commercially used helium.

헬륨을 냉매로 사용한 1/4파장 열음향 냉동기의 성능 평가 (The Performance Investigation of 1/4 Wavelength Thermoacoustic Refrigerator with Helium Refrigerant)

  • 송규조;박종호;이성노
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.52-57
    • /
    • 2002
  • In this study, a thermoacoustic refrigerator, using a resonant standing acoustic wave. has been built. The refrigerant is helium gas. The description of thermoacoustic refrigerator was Presented. The temperature ratio (cold part temperature over hot part temperature) and the COP (Coefficient of Performance) that normalized by carnot's COP are plotted versus the thermal load applied to the cold end, for- various speaker power.

수소액화용 직접냉각장치의 설계 및 성능시험 (Design and Performance Test of a Direct Cooling Equipment for Hydrogen Liquefaction)

  • 백종훈;강병하;장호명
    • 한국수소및신에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.121-128
    • /
    • 1996
  • 수소액화를 위한 직접냉각장치를 개발하고, 이의 성능특성을 시험하였다. 직접냉각장치는 액화용기, 복사쉴드, 저온조와 GM냉동기 등으로 구성하였다. 개발된 액화장치의 cool-down 및 warm-up특성이 상세하게 규명되었다. 본 냉각장치에서 냉각이 시작된지 약 45분 후, 액화용기내의 수소가 액화되기 시작함을 확인하였다. 또한 동일한 실험을 기체헬륨에 대하여 수행하였으며, 기체헬륨은 주어진 작동조건에서 액화되지 않으므로 수소의 경우와는 다른 cool-down 및 warm-up 특성을 보였다. 충전된 기체의 자연대류현상의 영향을 고찰하기 위하여 액화용기내에 진공상태를 유지하면서 시험하였다. 이때 진공상태에서의 액화용기의 냉각시간은 현저히 증가함을 보였다.

  • PDF

액체헬륨을 이용한 위성시험용 극저온패널 냉각시스템 개발 및 검증 (Development and Validation of Cryopanel Cooling System Using Liquid Helium for a Satellite Test)

  • 조혁진;문귀원;서희준;이상훈;홍석종;최석원
    • 대한기계학회논문집B
    • /
    • 제34권2호
    • /
    • pp.213-218
    • /
    • 2010
  • 인공위성 적외선 탑재체의 열싱크 역할을 위해, 액체헬륨을 이용하여 극저온패널(가로 약 800 mm, 세로 약 700 mm)을 4.2 K까지 냉각시키는 시스템을 설계, 개발, 검증하였다. 유효직경 8 m, 유효 깊이 10 m의 대형열진공챔버에서 검증된 본 냉각시스템은 500리터 용량의 액체헬륨용기 두 개(극저온 패널로의 액체헬륨 또는 저온헬륨가스 주 공급용기 및 주공급용기로의 재충진용기)를 사용하였는데, 목표인 극저온패널의 냉각 및 온도제어는 주 공급용기 내부의 미세압력조절을 통해 액체헬륨 공급유량을 제어함으로써 이루었다. 극저온패널에 공급된 후 배기되는 저온 헬륨가스는 특별히 설계, 제작된 사중진공배관의 제3층을 흐르며 열차단막의 역할을 수행함으로써, 액체헬륨 공급 라인인 제1층(중심배관)으로의 열유입을 최소화하였다. 극저온패널을 상온에서 40 K(합성표준불확도 194 mK)까지 냉각시키는데 약 3시간이 소요되었으며, 20 W의 열을 발산하는 극저온패널을 40 K 주변 온도에서 1 K 이내의 온도균일도를 가지며 유지할 수 있었다.

Design and simulation of a blanket module with high efficiency cooling system of tokamak focused on DEMO reactor

  • Sadeghi, H.;Amrollahi, R.;Zare, M.;Fazelpour, S.
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.323-327
    • /
    • 2020
  • In this study, the neutronic calculation to obtain tritium breeding ratio (TBR) in a deuterium-tritium (D-T) fusion power reactor using Monte Carlo MCNPX is done. In addition, by using COMSOL software, an efficient cooling system is designed. In the proposed design, it is adequate to enrich up to 40% 6Li. Total tritium breeding ratio of 1.12 is achieved. The temperature of helium as coolant gas never exceed 687℃. As regards the tolerable temperature of beryllium (650℃), the design of blanket module is done in the way that beryllium temperature never exceed 600℃. The main feature of this design indicates the temperature of helium coolant is higher than other proposed models for blanket module, therefore power of electricity generation will increase.