• Title/Summary/Keyword: Helical segment

Search Result 10, Processing Time 0.027 seconds

Investigation of Prior Technology and Development Case for Consecutive Excavation Technique of Shield TBM (연속굴착 쉴드 TBM 기술 관련 해외기술 및 개발사례 조사)

  • Mun-Gyu Kim;Jung-Woo Cho;Hyeong-seog Cha
    • Tunnel and Underground Space
    • /
    • v.33 no.5
    • /
    • pp.299-311
    • /
    • 2023
  • Continuous excavation technologies are developed to improve the excavation rate of shield TBM. Continuous excavation is a technology that provides thrust to segments, excluding being installed one, to reduce tunneling downtime. This paper investigated the prior technology related to continuous excavation segments. The main technology was classified into helical segment, honeycomb segment, and conventional segment methods. The helical segment method has not been applied in actual construction yet, and the honeycomb segment method has not succeeded in commercialization. The continuous excavation method using conventional segments has been successfully demonstrated. The thrust force and operation method of the thrust jacks for the semi-continuous technology were analyzed. Continuous excavation TBM research is also progressing in Korea, and through the analysis of successful cases, the need to develop independent continuous excavation methods has been identified.

Continuous Excavation Type TBM Parts Modification and Control Technology for Improving TBM Performance (TBM 굴진향상을 위한 연속굴착형 TBM 부품개조 및 제어기술 소개)

  • Young-Tae, Choi;Dong-Geon, Lee;Mun-Gyu, Kim;Joo-Young, Oh;Jung-Woo, Cho
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.345-352
    • /
    • 2022
  • The existing NATM (New Austrian Tunneling Method) has induced civil compliants due to blasting vibration and noise. Machanized excavation methods such as TBM (Tunnel Boring Machine) are being adopted in the planning and construction of tunneling projects. Shield TBM method is composed of repetition processes of TBM excavation and segment installation, the machine has to be stopped during the later process. Consecutive excavation technology using helical segment is under developing to minimize the stoppage time. The modification of thrust jacks and module are planned to ensure the advance force acting on the inclined surface of helical segment. Also, the integrated system design of hydraulic circuit will be remodeled. This means that the system deactivate the jacks on the installing segment while the others automatically act the thrusting forces on the existing segments. This report briefly introduces the mechanical research part of the current consecutive excavation technological development project of TBM.

Successful replantation of an amputated helical rim with microvascular anastomosis

  • Seo, Bommie Florence;Choi, Hyuk Joon;Lee, Min Cheol;Jung, Sung-No
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.4
    • /
    • pp.304-308
    • /
    • 2018
  • Replantation using microvascular anastomosis is considered to be the optimal method in treating the amputated ear in terms of resulting color, texture, and shape. Only a few cases of ear replantation have been reported because it is anatomically difficult to identify suitable vessels for anastomosis. We successfully replanted the amputated helical rim of the ear using single arterial anastomosis. A 37-year-old man had his helical rim amputated by a human bite. The amputee was about $4{\times}1cm$ in dimension, composed of skin and soft tissue including auricular cartilage. Replantation was performed anastomosing a small artery of the amputee with a terminal branch of the posterior auricular artery. After replantation, intravenous heparinization was performed and prostaglandin E1 and aspirin were administered. Venous congestion was decompressed by stab incisions applied with heparin solution soaked gauze. Venous congestion of the amputee slowly began to resolve at 4 days after the operation. The amputated segment of the helical rim survived completely with good aesthetic shape and color. The authors propose that performing microvascular anastomosis should be attempted especially if it is possible to detect vessels on cut surfaces of ear amputee and stump. Proper postoperative care for venous congestion, arterial insufficiency, and infection should be followed for amputee survival.

Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography (64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가)

  • Seoung, Youl-Hun;Kim, Yong-Ok;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • The purpose of this study was to evaluate the usefulness of reducing of craniofacial radiation dose using automatic exposure control (AEC) technique in the 64 multi-detector computed tomography (MDCT). We used SOMATOM Definition 64 multi-detector CT, and head of whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd). The protocol were helical scan method with 120 kVp, 1 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of FOV, $512{\times}512$ of matrix size, $64{\times}0.625\;mm$ of collimation, and 1 of pitch. The evaluation of dose reducing effect was compared the fixed tube current of 350 with AEC technique. The image quality was measured the noise using standard deviation of CT number. The range of craniofacial bone was to mentum end from calvaria apex, which devided three regions: calvaria~superciliary ridge (1 segment), superciliary ridge~acanthion (2 segment), and acanthion~mentum (3 segment). In the fixed tube current technique, CTDIvol was 57.7 mGy, DLP was $640.2\;mGy{\cdot}cm$ in the all regions. The AEC technique was showed that 1 segment were 30.7 mGy of CTDIvol, 340.7 $mGy{\cdot}cm$ of DLP, 2 segment were 46.5 mGy of CTDIvol, $515.0\;mGy{\cdot}cm$ of DLP, and 3 segment were 30.3 mGy of CTDIvol, $337.0\;mGy{\cdot}cm$ of DLP. The standard deviation of CT number was 2.622 with the fixed tube current technique and 3.023 with the AEC technique in the 1 segment, was 3.118 with the fixed tube current technique and 3.379 with the AEC technique in the 2 segment, was 2.670 with the fixed tube current technique and 3.186 with the AEC technique in the 3 segment. The craniofacial radiation dose using AEC Technique in the 64 MDCT was evaluated the usefulness of reducing for the eye, the parotid and thyroid with high radiation sensitivity particularly.

Identification of an antimicrobial peptide from human methionine sulfoxide reductase B3

  • Kim, Yong-Joon;Kwak, Geun-Hee;Lee, Chu-Hee;Kim, Hwa-Young
    • BMB Reports
    • /
    • v.44 no.10
    • /
    • pp.669-673
    • /
    • 2011
  • Human methionine sulfoxide reductase B3A (hMsrB3A) is an endoplasmic reticulum (ER) reductase that catalyzes the stereospecific reduction of methionine-R-sulfoxide to methionine in proteins. In this work, we identified an antimicrobial peptide from hMsrB3A protein. The N-terminal ER-targeting signal peptide (amino acids 1-31) conferred an antimicrobial effect in Escherichia coli cells. Sequence and structural analyses showed that the overall positively charged ER signal peptide had an Argand Pro-rich region and a potential hydrophobic ${\alpha}$-helical segment that contains 4 cysteine residues. The potential ${\alpha}$-helical region was essential for the antimicrobial activity within E. coli cells. A synthetic peptide, comprised of 2-26 amino acids of the signal peptide, was effective at killing Gram-negative E. coli, Klebsiella pneumoniae, and Salmonella paratyphi, but had no bactericidal activity against Gram-positive Staphylococcus aureus.

Structural investigation on the intrinsically disordered N-terminal region of HPV16 E7 protein

  • Lee, Chewook;Kim, Do-Hyoung;Lee, Si-Hyung;Su, Jiulong;Han, Kyou-Hoon
    • BMB Reports
    • /
    • v.49 no.8
    • /
    • pp.431-436
    • /
    • 2016
  • Human papillomavirus (HPV) is the major cause of cervical cancer, a deadly threat to millions of females. The early oncogene product (E7) of the high-risk HPV16 is the primary agent associated with HPV-related cervical cancers. In order to understand how E7 contributes to the transforming activity, we investigated the structural features of the flexible N-terminal region (46 residues) of E7 by carrying out N-15 heteronuclear NMR experiments and replica exchange molecular dynamics simulations. Several NMR parameters as well as simulation ensemble structures indicate that this intrinsically disordered region of E7 contains two transient (10-20% populated) helical pre-structured motifs that overlap with important target binding moieties such as an E2F-mimic motif and a pRb-binding LXCXE segment. Presence of such target-binding motifs in HPV16 E7 provides a reasonable explanation for its promiscuous target-binding behavior associated with its transforming activity.

A Study on Performance Analysis of the Helically Coiled Evaporator with Circular Minichannels

  • Kim Ju-Won;Im Yong-Bin;Kim Jong-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.7
    • /
    • pp.1059-1067
    • /
    • 2006
  • In order to develop a compact evaporator, experiments that show characteristics of evaporating heat transfer and pressure drop in the helically coiled minichannel were performed in our previous research. This study was focused on the performance analysis of helically coiled heat exchangers with circular minichannels with an inner diameter=1.0 mm. The working fluid was R-22, and the properties of R-22 were estimated using the REFPROP program. Numerical simulation was performed to compare results with the experimental results of the helically coiled heat exchanger. As the heat transfer rate and pressure drop were calculated at the micro segment of the branch channels, the performance of the evaporator was evaluated. The following conclusions were obtained through the numerical simulations of the helically coiled heat exchanger. It showed good performance when the flow rate of each branch channels was suitable to heat load of air-side. The numerical simulation value agreed with experimental results within ${\pm}15%$. In this study, a numerical simulation program was developed to estimate the performance of a helically coiled evaporator. And, an optimum helically coiled minichannels evaporator was designed.

Computational Hemodynamics in the Intracranial Aneurysm Model (뇌동맥류 모델에 대한 혈류역학 해석)

  • Seo, Taewon;Byun, Jun Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.10
    • /
    • pp.927-932
    • /
    • 2013
  • The intracranial aneurysm model is extracted based on the Computed Tomography (CT) scan images. Computational fluid dynamics simulations were conducted under both steady and realistic flow conditions in ANSYS-FLUENT. The minimum wall shear stress in the intracranial aneurysm tended to occur in the aneurysmal region. The magnitude of wall shear stress along inner wall of the curvature in the right M1 segment of middle cerebral artery is approximately 20 times higher than that along both the proximal and distal walls. However, the magnitudes of the wall shear stress at the aneurysm region were considerably low. The blood flow has the complex distribution in the aneurysmal region during the systolic period. Complex helical flow patterns are observed inside the aneurysm. Through an analysis of the hemodynamic characteristics, one may predict the rupture of the cerebral aneurysms.

Electrical Stimulation Causes Endothelium-Dependent Relaxation in Isolated Aortic Vessels of the Rabbit (토끼 흉부 대동맥 절편의 전기자극에 대한 수축 및 이완반응)

  • Lee, Seok-Gi;Choe, Hyeong-Ho;Lee, Jong-Un
    • Journal of Chest Surgery
    • /
    • v.28 no.8
    • /
    • pp.742-746
    • /
    • 1995
  • The present study was aimed at investigating possible transmitter mechanisms in the endothelial cell layer in regulating the tone of the vascular smooth muscle. The thoracic aorta was isolated from the anesthetized male white rabbits and its helical strips were prepared. Electrical field stimulation was delivered to platinum wire electrodes positioned parallel to the vessel segment preconstricted with phenylephrine [3.5x10-6 mol/L at a distance of 1.5-2.0 mm. The electrical stimulation [70 V, 5 msec, 0.5-200 Hz caused either relaxation only [34% or a biphasic response [prolonged relaxation following a weak and transient contraction, 66% . The relaxation response was frequency- dependent, and at 200 Hz a complete relaxation was noted. Mechanical rubbing of the endothelial layer abolished or greatly attenuated the relaxation. The relaxation was also markedly attenuated in the presence of NG-nitro- L-arginine methyl ester [10-3mol/L or procaine hydrochloride [3.5x10-4mol/L . Tetrodotoxin,guanethidine, atropine or indomethacin failed to block or enhance the relaxation response to electrical field stimulation. It is concluded that the vascular endothelium in the aorta contains diffusible substances that regulates the function of the smooth muscle layer, in which relaxation is more prominent than contraction. Their release by the electrical stimualtion in vitro may not involve classic neuronal transmitter release mechanisms or metabolism of arachidonic acids by cyclooxygenase. The release of the relaxing agents may require an increase in cytosolic calcium level. The chemical nature of the relaxant may be, to a large extent, nitric oxide.

  • PDF

Replication origins oriGNAI3 and oriB of the mammalian AMPD2 locus nested in a region of straight DNA flanked by intrinsically bent DNA sites

  • Balani, Valerio Americo;De Lima Neto, Quirino Alves;Takeda, Karen Izumi;Gimenes, Fabricia;Fiorini, Adriana;Debatisse, Michelle;Fernandez, Maria Aparecida
    • BMB Reports
    • /
    • v.43 no.11
    • /
    • pp.744-749
    • /
    • 2010
  • The aim of this work was to determine whether intrinsically bent DNA sites are present at, or close to, the mammalian replication origins oriGNAI3 and oriB in the Chinese hamster AMPD2 locus. Using an electrophoretic mobility shift assay and in silico analysis, we located four intrinsically bent DNA sites (b1 to b4) in a fragment that contains the oriGNAI3 and one site (b5) proximal to oriB. The helical parameters show that each bent DNA site is curved in a left-handed superhelical writhe. A 2D projection of 3D fragment trajectories revealed that oriGNAI3 is located in a relatively straight segment flanked by bent sites b1 and b2, which map in previously identified Scaffold/Matrix Attachment Region. Sites b3 and b4 are located approximately 2 kb downstream and force the fragment into a strong closed loop structure. The b5 site is also located in an S/MAR that is found just downstream of oriB.