• 제목/요약/키워드: Helical mode

검색결과 64건 처리시간 0.028초

Free vibration analysis of a uniform beam carrying multiple spring-mass systems with masses of the springs considered

  • Wu, Jia-Jang
    • Structural Engineering and Mechanics
    • /
    • 제28권6호
    • /
    • pp.659-676
    • /
    • 2008
  • The reports regarding the free vibration analysis of uniform beams carrying single or multiple spring-mass systems are plenty, however, among which, those with inertia effect of the helical spring(s) considered are limited. In this paper, by taking the mass of the helical spring into consideration, the stiffness and mass matrices of a spring-mass system and an equivalent mass that may be used to replace the effect of a spring-mass system are derived. By means of the last element stiffness and mass matrices, the natural frequencies and mode shapes for a uniform cantilever beam carrying any number of springmass systems (or loaded beam) are determined using the conventional finite element method (FEM). Similarly, by means of the last equivalent mass, the natural frequencies and mode shapes of the same loaded beam are also determined using the presented equivalent mass method (EMM), where the cantilever beam elastically mounted by a number of lumped masses is replaced by the same beam rigidly attached by the same number of equivalent masses. Good agreement between the numerical results of FEM and those of EMM and/or those of the existing literature confirms the reliability of the presented approaches.

마이크로파 자유전자 레이저의 제작 및 동작특성 연구 (Construction of a microwave free electron laser and studies of its characteristics)

  • 이관철;정기형
    • 한국광학회지
    • /
    • 제3권1호
    • /
    • pp.43-49
    • /
    • 1992
  • Marx generator와 진공 다이오드, Bifilar helical wiggler, 인도자장 솔레노이드 등을 이용하여 마이크로파 영역의 자유전자 레이저를 설계 제작하였다. Bifilar helical wiggler의 자장분포를 분석하였고 공간전하의 수직성분 효ㅗ가를 고려하여 계산한 전자궤적 모의실험을 통하여 Wiggler자장이 전자빔 입사에 적합함을 확인하였다. Wiggler자장 300G, 인도자장 4.4kG, 전자빔 에너지 170keV일때 분산방정식에 의하여 계산된 출력 주파수는 약 11GHz였고 실험 결과 나타난 출력 주파수의 점위는 9.78GHz-11.7GHz로 추정되었다. 전자 속도의 축방향 퍼짐을 고려하여 이론적으로 이득을 계산하였다.

  • PDF

스월제트에 관한 헬리컬 불안정파 자극 (Helical Instability Wave Excitation of Swirling Jets)

  • 이원중
    • 한국항공우주학회지
    • /
    • 제33권1호
    • /
    • pp.48-53
    • /
    • 2005
  • 본 연구의 목적은 기계적인 전단층 자극방법을 이용 스월제트 혼합향상의 가능성을 고찰함에 있다. 이를 위해 기계적 자극장치가 설계, 제작되었다. 주요 구성품으로는 두개의 아음속 노즐, 스월 발생기, 그리고 유동 자극기 등이다. 실험은 다음과 같은 다양한 헬리컬 모드들에서 수행되었다; m=+0, m=$\pm$1, m=$\pm$2, m=$\pm$3, m=$\pm$4. 열선유속계를 이용한 plane 파동과 헬리컬 파동 자극에 따른 제트속도 측정이 이루어 졌다. 다양한 헬리컬 모드에서의 결과 값들이 기준 값(plane-wave)과 비교되었다. 획득된 결과는 3-D mesh plot 과 2-D contour plot으로 표현되었다. 이로써 새로 고안된 장치는 헬리컬 불안정파 자극에 대한 효과를 입증하였고 또한 결과적으로 스월제트의 혼합을 증진시켰다.

단말기 T-DMB용 안테나로 사용될 수 있는 Open Stub를 가지는 소형 Two-Wire Helical 안테나 (A Compact Two-Wire Helical Antenna with an Open Stub for a T-DMB Antenna of Mobile Devices)

  • 이동현;박세현;김영일;박위상
    • 한국전자파학회논문지
    • /
    • 제18권2호
    • /
    • pp.151-157
    • /
    • 2007
  • 본 논문에서는 모바일 장치의 T-DMB 안테나로 사용될 수 있는 급전 반대편에 open stub를 가지는 소형 two-wire helical 안테나를 제안하였다. Open stub의 길이를 조절하거나 open stub에 유전 물질을 발라 T-DMB 대역인 200 MHz에서 높이가 8 cm(200 MHz에서 0.053 $\lambda$임)인 안테나의 입력 임피던스를 쉽게 매칭시킬 수 있다. 이 안테나의 unbalanced 모드와 balanced 모드의 등가 회로를 이용하여 이 안테나의 등가 회로를 나타내고, 동작 원리를 설명하였다. 등가 회로의 해석을 토대로 open stub의 영향을 검증했다. 몇 가지 다른 파라미터 값을 가지는 안테나를 제작하였으며, 이 안테나의 $S_{11}$$S_{21}$을 측정하였다. 제작된 안테나의 임력 임피던스 대역폭($S_{11}{\leq}-10dB$)은 $196{\sim}204$ MHz(8 MHz)로 T-DMB의 한 채널(6 MHz)을 만족한다. 이 안테나의 측정된 $S_{21}$은 -38.6 dB로 동일한 높이의 모노폴 안테나와 open stub를 가지지 않은 two-wire helical 안테나의 $S_{21}$보다 약 17 dB 높다.

Mode Identification in the Design of Wideband Cylindrical Monopole Antenna

  • Chun, Joong-Chang;Kim, Sang-Youl;Jeung, Deuk-Soo
    • Journal of information and communication convergence engineering
    • /
    • 제7권3호
    • /
    • pp.263-267
    • /
    • 2009
  • Cylindrical monopole antenna is one of most promising candidates for multi-band applications such as PCS, WLAN, DMB, and UWB wireless services. In this research, we demonstrate that there exist two types of current distributions according to the exciting frequency in a double band cylindrical monopole antenna, in which double resonance is achieved by adjusting the coupling structure of the antenna base. The operating modes of current distributions are identified from CST software simulations, the standing wave mode in a lower band and the traveling wave mode in a higher band. Also it is noticed that the mode behavior is quite similar to a helical antenna, a standing-wave (resonance) mode and a traveling-wave (non-resonance) mode according to the electrical dimensions of antenna. The effective ranges for operating modes and design formulas of the double band antenna are derived from simulation and measured results.

Analysis of the solution structure of the human antibiotic peptide dermcidin and its interaction with phospholipid vesicles

  • Jung, Hyun-Ho;Yang, Sung-Tae;Sim, Ji-Yeong;Lee, Seung-Kyu;Lee, Ju-Yeon;Kim, Ha-Hyung;Shin, Song-Yub;Kim, Jae-Il
    • BMB Reports
    • /
    • 제43권5호
    • /
    • pp.362-368
    • /
    • 2010
  • Dermcidin is a human antibiotic peptide that is secreted by the sweat glands and has no homology to other known antimicrobial peptides. As an initial step toward understanding dermcidin's mode of action at bacterial membranes, we used homonuclear and heteronuclear NMR to determine the conformation of the peptide in 50% trifluoroethanol solution. We found that dermcidin adopts a flexible amphipathic $\alpha$-helical structure with a helix-hinge-helix motif, which is a common molecular fold among antimicrobial peptides. Spin-down assays of dermcidin and several related peptides revealed that the affinity with which dermcidin binds to bacterial-mimetic membranes is primarily dependent on its amphipathic $\alpha$-helical structure and its length (>30 residues); its negative net charge and acidic pI have little effect on binding. These findings suggest that the mode of action of dermcidin is similar to that of other membrane-targeting antimicrobial peptides, though the details of its antimicrobial action remain to be determined.

터보압축기의 진동 특성에 관한 해석적 연구 (An Analytical Investigation on Vibrational Characteristics of Turbo Compressor)

  • 이형우;이동환;박노길
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1069-1077
    • /
    • 1998
  • A dynamic model of turbo compressor having helical gear pairs is developed. The model accounts for the shaft and bearing flexibilities, gyroscopic effects and the force couplings among the transverse, torsion. and axial motions due to gearings. For the mode analysis of turbo compressor, a transfer matrix method is used. The excitation sources caused by the mass unbalances of the rotors and misalignment of the shafts, the transmitted errors of the gearings. and the vane passing frequencies of the Impeller are studied qualitatively. By introducing the perturbation method, the generated forcing frequencies are defined and devided into three groups. With the field data, two critical speeds are analytically found and the corresponding modal characteristics are examined.

  • PDF

Conformation and Biological Activity of Mastoparan B and Its Analogs I

  • 박남규;서정길;구희정;이산나무;Gohsuke Sugihara;김광호;박장수;강신원
    • Bulletin of the Korean Chemical Society
    • /
    • 제18권1호
    • /
    • pp.50-56
    • /
    • 1997
  • The mode of action of mastoparan B, an antimicrobial cationic tetradecapeptide amide isolated from the hornet Vespa basalis, toward phospholipid bilayers was studied with synthetic mastoparan B and its analogs with individual Ala instead of hydrophobic amino acids (1-Ile, 3-Leu, 6-Leu, 7-Val, 9-Trp, 13-Val, 14-Leu) in mastoparan B. Mastoparan B and its analogs were synthesized by the solid-phase method. Circular dichroism spectra showed that mastoparan B and its analogs adopted an unordered structure in buffer solution. In the presence of neutral and acidic liposomes, most of the peptides took an α-helical structure. The calcein leakage experiment indicated that mastoparan B interacted strongly with neutral and acidic lipid bilayers than its analogs. Mastoparan B also showed a more or less highly antimicrobial activity and hemolytic activity for human erythrocytes than its analogs. These results indicate that the hydrophobic face in the amphipathic α-helix of mastoparan B critically affect biological activity and helical contents.

토모테라피를 이용한 3차원 입체 조형 치료의 임상적 적용 분석 (Clinical Application Analysis of 3D-CRT Methods Using Tomotherapy)

  • 조강철;김주호;김훈겸;안승권;이상규;윤종원;조정희;이종석;유병규
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권4호
    • /
    • pp.327-335
    • /
    • 2013
  • 토모테라피를 이용한 3D-CRT의 임상적 적용 사례를 Helical mode와 Direct mode로 구분하여 치료목적에 따라 주 치료목적 및 보조적 치료 목적으로 적용된 사례에 대해 선량학적 평가를 시행하였고 기존의 라이낙을 이용한 기법과 종양의 발생 부위별 선량학적 분포의 차이를 비교, 분석하였다. 선량 분석은 육종, 뇌척수조사, 유방, 뇌, 췌장, 척추 전이, 상대정맥 증후군, 식도에 토모테라피를 이용한 3차원 입체조형 방사선치료로 치료받는 환자 8명을 대상으로 Helical mode와 Direct mode, 라이낙 기반 치료 기법 사이의 치료 계획 간 비교하였으며, 선량분석은 선량 체적 히스토그램과 등선량 곡선을 이용했다. Direct mode로 치료한 육종, 뇌척수 조사 환자의 경우 체적 길이에 대한 영향을 받지 않아 Junction effect 없는 선량적 결과를 보여주었고, 유방 환자는 D 99%와 D 95%의 선량에서 $49.2{\pm}0.4$ Gy와 $49.9{\pm}0.4$ Gy, V 105%와 V 110%에서 0%로 나타났다. Helical mode로 치료한 뇌, 췌장, 척추 전이 환자에서 dosimetric block을 이용해 정상조직의 선량을 효과적으로 줄일 수 있었고, 상대정맥 증후군 환자는 선량 제한(dose limitation)을 통해 방사선 치료를 재 실시해도 척수선량을 38 Gy이하로 효과적으로 제한할 수 있었다. 식도 환자에서는 기존에 다른 기법과 함께 추가조사 목적으로 사용하여 총 척수선량을 45 Gy 이하로 하고 폐의 V 20%을 20% 이하로 제한할 수 있었다. 토모테라피를 이용한 3차원 입체조형치료는 기존 선형가속기를 이용한 3차원 입체조형 방사선치료에 비해 선량적으로 제한되는 부분을 개선해주고 임상적으로 적절한 선량분포를 구현하는데 효과적인 방법 중의 하나라고 사료된다.

팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰 (A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom)

  • 최재혁;정도형;최계숙;장요종;김재원;이희석
    • 대한방사선치료학회지
    • /
    • 제19권2호
    • /
    • pp.123-129
    • /
    • 2007
  • 목 적: 전산화 단층촬영방법(Computed Tomography, CT)에 따라 고식적(Axial), 나선식(Helical), 연속(Cine) 주사방법으로 획득되어진 영상은 주사방법이 다르므로 각각의 재현되는 이미지 상에서 차이가 존재한다. 각각의 전산화 단층촬영 주사방법(scan type)이 움직임을 얼마나 정확히 묘사하는지 알아보고자 구동 팬톰을 이용하여 재현성에 대해 고찰해 보고자 한다. 대상 및 방법: 상 하 방향, 위 아래 방향 움직임을 재현하기 위해 자체 제작한 구동 팬톰과 호흡동조 구동 motor를 이용한다. 구동 motor 위에 표지자를 올려놓고 전산화 단층촬영 시 움직임을 구별하기 위해 표지자에 위치 표시를 위한 방사선 비투과성 물질(Localizer)을 부착한다. 자체 제작한 구동 팬톰을 이용하여 위 아래 움직임은 1.3 cm (16회/1분당)으로 고정 시키고, 호흡동조 구동 motor을 이용하여 상 하 움직임은 0.2 cm (8 rot/1분당)으로 고정 한다. 각각의 움직임을 고정 시키고 난 후, 전산화 단층 촬영 방법에 따라 고식적(Axial), 나선식(Helical), 연속(Cine) 주사방법으로 촬영한다. RPT 장비를 이용하여 움직임을 나타내는 표지자에 부착한 방사선 비투과성 물질과 볼륨 재현성이 정확한지 비교, 분석 한다. 결 과: 표지자의 전체 체적은 88.2 $cm^3$로 위 아래 방향 3 cm, 상 하 방향 0.3 cm 이동을 고려했을 때는 전체 체적이 184.3 $cm^3$이었다. 각각의 전산화 단층촬영방법에 따른 전체 체적은 고식적 주사방법에서는 135 $cm^3$, 나선식 주사방법에서는 164.9 $cm^3$, 연속 주사방법에서는 181.7 $cm^3$였다. 움직임에 대한 재현성을 나타내는 데 있어 연속 주사방법에서 가장 근접하게 표지자를 묘출하였다. 또한, 표지자에 부착한 방사선 비투과성 물질의 재현성에서도 연속 주사방법에서 가장 근접하게 나타내었다. 결 론: 전산화 단층촬영방법에 따른 고식적, 나선식, 연속 주사방법은 움직임에 영향을 많이 받는 장기를 촬영할 때, 움직임에 따른 정확한 장기 묘사 및 종양 조직의 움직임을 재현해야 한다. 본 실험에서 사용한 구동 팬톰을 이용한 표지자를 재현하는데 있어 전산화 단층촬영 시 연속 주사방법에서 촬영 할 때 가장 재현성이 높았다. 하지만, 임상 적용 시 환자의 호흡이나 움직임이 팬톰처럼 일정하지 않기 때문에 이를 위한 환자 교육 및 호흡을 일정하게 해줄 수 있는 장치의 사용 및 개발이 필요하며, 각각의 전산화 단층촬영방법에 대한 피폭선량에 대해서도 고려해야 할 것이라 사료 된다.

  • PDF