• Title/Summary/Keyword: Helical mode

Search Result 64, Processing Time 0.03 seconds

Free vibration analysis of a uniform beam carrying multiple spring-mass systems with masses of the springs considered

  • Wu, Jia-Jang
    • Structural Engineering and Mechanics
    • /
    • v.28 no.6
    • /
    • pp.659-676
    • /
    • 2008
  • The reports regarding the free vibration analysis of uniform beams carrying single or multiple spring-mass systems are plenty, however, among which, those with inertia effect of the helical spring(s) considered are limited. In this paper, by taking the mass of the helical spring into consideration, the stiffness and mass matrices of a spring-mass system and an equivalent mass that may be used to replace the effect of a spring-mass system are derived. By means of the last element stiffness and mass matrices, the natural frequencies and mode shapes for a uniform cantilever beam carrying any number of springmass systems (or loaded beam) are determined using the conventional finite element method (FEM). Similarly, by means of the last equivalent mass, the natural frequencies and mode shapes of the same loaded beam are also determined using the presented equivalent mass method (EMM), where the cantilever beam elastically mounted by a number of lumped masses is replaced by the same beam rigidly attached by the same number of equivalent masses. Good agreement between the numerical results of FEM and those of EMM and/or those of the existing literature confirms the reliability of the presented approaches.

Construction of a microwave free electron laser and studies of its characteristics (마이크로파 자유전자 레이저의 제작 및 동작특성 연구)

  • 이관철;정기형
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.43-49
    • /
    • 1992
  • A microwave free electron laser which consists of Marx generator, vacuum diode, bifilar helical wiggler, and guide solenoid was designed and constructed. The analysis of the magnetic field distributions of the bifilar helical wiggler and computer simulation of electron trajectories with the perpendicular effect of space charges led to the conclusion that the magnetic field distributions are suitable for the electron beam injection. Output frequency in a single $TE_{11}$

  • PDF

Helical Instability Wave Excitation of Swirling Jets (스월제트에 관한 헬리컬 불안정파 자극)

  • Lee, Won-Joong;Taghavi, Ray-R.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.1
    • /
    • pp.48-53
    • /
    • 2005
  • The purpose of this investigation is to explore the possibility of using artificial mechanical means for excitation of shear layers with application in swirling jet mixing enhancement. For this purpose, a mechanical excitation device was designed and fabricated. The major system components consist of two subsonic nozzles, one swirl generator, and the excitation device. The experiments were carried out at various helical excitation modes; i.e., m=+0, m=$\pm$1, m=$\pm$2, m=$\pm$3, and m=$\pm$4. Axial mean velocity measurements were made with plane and helical wave excitation using a hot-wire anemometer. The results are compared with the baseline (plane-wave excitation) at various helical modes. The acquired data is presented in 3-D mesh plots and 2-D contour plots. It was observed that new device was effective in excitation of the helical instability waves and resulting in mixing enhancement of the swirling jet.

A Compact Two-Wire Helical Antenna with an Open Stub for a T-DMB Antenna of Mobile Devices (단말기 T-DMB용 안테나로 사용될 수 있는 Open Stub를 가지는 소형 Two-Wire Helical 안테나)

  • Lee, Dong-Hyun;Park, Se-Hyun;Kim, Young-Eil;Park, Wee-Sang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.151-157
    • /
    • 2007
  • We have presented a compact two-wire helical antenna adopted an open stub in opposite to a feeding point, which is for a T-DMB antenna of mobile devices. By adjusting the length of the open stub or pasting a dielectric material on the open stub, the input impedance around 200 MHz, bands of the T-DMB, can be easily control, even though the total height of the antenna is less than 8 cm(0.053 $\lambda$ at 200 MHz). The operating mechanism of the antenna is explained by using equivalent circuits of two modes, an unbalanced mode and a balanced mode. Based on the analysis of the equivalent circuits, the effects of using the open stub are validated. Several proposed antennas have been fabricated and measured. One of the fabricated antennas has -10 dB impedance bandwidth of $196{\sim}204$ MHz(8 MHz) whose value covers one channel of the T-DMB(6 MHz). The measured $S_{21}$ of the antenna is -38.6 dB which is about 17 dB higher than that of a monopole antenna whose height is same with the proposed antenna.

Mode Identification in the Design of Wideband Cylindrical Monopole Antenna

  • Chun, Joong-Chang;Kim, Sang-Youl;Jeung, Deuk-Soo
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.3
    • /
    • pp.263-267
    • /
    • 2009
  • Cylindrical monopole antenna is one of most promising candidates for multi-band applications such as PCS, WLAN, DMB, and UWB wireless services. In this research, we demonstrate that there exist two types of current distributions according to the exciting frequency in a double band cylindrical monopole antenna, in which double resonance is achieved by adjusting the coupling structure of the antenna base. The operating modes of current distributions are identified from CST software simulations, the standing wave mode in a lower band and the traveling wave mode in a higher band. Also it is noticed that the mode behavior is quite similar to a helical antenna, a standing-wave (resonance) mode and a traveling-wave (non-resonance) mode according to the electrical dimensions of antenna. The effective ranges for operating modes and design formulas of the double band antenna are derived from simulation and measured results.

Analysis of the solution structure of the human antibiotic peptide dermcidin and its interaction with phospholipid vesicles

  • Jung, Hyun-Ho;Yang, Sung-Tae;Sim, Ji-Yeong;Lee, Seung-Kyu;Lee, Ju-Yeon;Kim, Ha-Hyung;Shin, Song-Yub;Kim, Jae-Il
    • BMB Reports
    • /
    • v.43 no.5
    • /
    • pp.362-368
    • /
    • 2010
  • Dermcidin is a human antibiotic peptide that is secreted by the sweat glands and has no homology to other known antimicrobial peptides. As an initial step toward understanding dermcidin's mode of action at bacterial membranes, we used homonuclear and heteronuclear NMR to determine the conformation of the peptide in 50% trifluoroethanol solution. We found that dermcidin adopts a flexible amphipathic $\alpha$-helical structure with a helix-hinge-helix motif, which is a common molecular fold among antimicrobial peptides. Spin-down assays of dermcidin and several related peptides revealed that the affinity with which dermcidin binds to bacterial-mimetic membranes is primarily dependent on its amphipathic $\alpha$-helical structure and its length (>30 residues); its negative net charge and acidic pI have little effect on binding. These findings suggest that the mode of action of dermcidin is similar to that of other membrane-targeting antimicrobial peptides, though the details of its antimicrobial action remain to be determined.

An Analytical Investigation on Vibrational Characteristics of Turbo Compressor (터보압축기의 진동 특성에 관한 해석적 연구)

  • 이형우;이동환;박노길
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1069-1077
    • /
    • 1998
  • A dynamic model of turbo compressor having helical gear pairs is developed. The model accounts for the shaft and bearing flexibilities, gyroscopic effects and the force couplings among the transverse, torsion. and axial motions due to gearings. For the mode analysis of turbo compressor, a transfer matrix method is used. The excitation sources caused by the mass unbalances of the rotors and misalignment of the shafts, the transmitted errors of the gearings. and the vane passing frequencies of the Impeller are studied qualitatively. By introducing the perturbation method, the generated forcing frequencies are defined and devided into three groups. With the field data, two critical speeds are analytically found and the corresponding modal characteristics are examined.

  • PDF

Conformation and Biological Activity of Mastoparan B and Its Analogs I

  • 박남규;서정길;구희정;이산나무;Gohsuke Sugihara;김광호;박장수;강신원
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.1
    • /
    • pp.50-56
    • /
    • 1997
  • The mode of action of mastoparan B, an antimicrobial cationic tetradecapeptide amide isolated from the hornet Vespa basalis, toward phospholipid bilayers was studied with synthetic mastoparan B and its analogs with individual Ala instead of hydrophobic amino acids (1-Ile, 3-Leu, 6-Leu, 7-Val, 9-Trp, 13-Val, 14-Leu) in mastoparan B. Mastoparan B and its analogs were synthesized by the solid-phase method. Circular dichroism spectra showed that mastoparan B and its analogs adopted an unordered structure in buffer solution. In the presence of neutral and acidic liposomes, most of the peptides took an α-helical structure. The calcein leakage experiment indicated that mastoparan B interacted strongly with neutral and acidic lipid bilayers than its analogs. Mastoparan B also showed a more or less highly antimicrobial activity and hemolytic activity for human erythrocytes than its analogs. These results indicate that the hydrophobic face in the amphipathic α-helix of mastoparan B critically affect biological activity and helical contents.

Clinical Application Analysis of 3D-CRT Methods Using Tomotherapy (토모테라피를 이용한 3차원 입체 조형 치료의 임상적 적용 분석)

  • Cho, Kang-Chul;Kim, Joo-Ho;Kim, Hun-Kyum;Ahn, Seung-Kwon;Lee, Sang-Kyoo;Yoon, Jong-Won;Cho, Jeong-Hee;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.327-335
    • /
    • 2013
  • This study investigates the case of clinical application for TomoDirect 3D-CRT(TD-3D) and TomoHelical 3D-CRT(TH-3D) with evaluating dose distribution for clinical application in each case. Treatment plans were created for 8 patients who had 3 dimensional conformal radiation therapy using TD-3D and TH-3D mode. Each patients were treated for sarcoma, CSI(craniospinal irradiaion), breast, brain, pancreas, spine metastasis, SVC syndrome and esophagus. DVH(dose volume histogram) and isodose curve were used for comparison of each treatment modality. TD-3D shows better dose distribution over the irradiation field without junction effect because TD-3D was not influenced by target length for sarcoma and CSI case. In breast case, dosimetric results of CTV, the average value of D 99%, D 95% were $49.2{\pm}0.4$ Gy, $49.9{\pm}0.4$ Gy and V 105%, V 110% were 0%, respectively. TH-3D with the dosimetric block decreased dose of normal organ in brain, pancreas, spine metastasis case. SCV syndrome also effectively decreased dose of normal organ by using dose block to the critical organs(spinal cord <38 Gy). TH-3D combined with other treatment modalities was possible to boost irradiation and was total dose was reduced to spinal cord in esophagus case(spinal cord <45 Gy, lung V 20 <20%). 3D-CRT using Tomotherapy could overcomes some dosimetric limitations, when we faced Conventional Linac based CRT and shows clinically proper dose distribution. In conclusion, 3D-CRT using Tomotherapy will be one of the effective 3D-CRT techniques.

A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom (팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰)

  • Choi, Jae-Hyock;Jeong, Do-Hyeong;Suk, Choi-Gye;Jang, Yo-Jong;Kim, Jae-Weon;Lee, Hui-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2007
  • Purpose: CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. Materials and Methods: To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Results: Total volume of a marker was 88.2 $cm^3$ considering movement of superior-inferior. Total volume was 184.3 $cm^3$. Total volume according to each CT scan protocol were 135 $cm^3$ by axial mode, 164.9 $cm^3$ by helical mode, 181.7 $cm^3$ by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. Conclusion: CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  • PDF