• Title/Summary/Keyword: Helical Coil

Search Result 80, Processing Time 0.026 seconds

Heat Transfer Characteristics of Carbon Dioxide in a Inclined Helical Coil Type Heat Exchanger with Inner Diameter Tube of 4.55 mm (내경 4.55 mm의 경사진 헬리컬 코일형 열교환기내 이산화탄소의 열전달 특성에 관한 연구)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.1-6
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during gas cooling process of $CO_2$ (R-744) in inclined helical coil copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube, which is specified as the inner diameter of 4.55 mm. The refrigerant mass fluxes were varied from 200 to $600kg/m^2s$ and the inlet pressures of gas cooler were done 7.5 to 10.0 (MPa). The heat transfer coefficients of $CO_2$ in the inclined helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows relatively good coincidence with those predicted by Ito's correlation developed for single-phase in a helical coil tube. The local heat transfer coefficient of $CO_2$ is well coincident with the correlation by Pitla et al. However, at the region near pseudo-critical temperature, the experiments indicate higher values than the Pitla et al. correlation.

  • PDF

Natural Convection Heat Transfer of an Inclined Helical Coil in a Duct (기울어진 덕트 내 헬리컬 코일의 자연대류 열전달)

  • Park, Joo-Hyun;Chung, Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.13-20
    • /
    • 2014
  • The natural convection heat transfers of a helical coil in a duct were measured experimentally varying the inclination. To achieve high Rayleigh number, mass transfer experiments instead of heat transfer experiments were performed based upon the analogy. The $Ra_D$ was fixed to $4.55{\times}10^6$. The turn numbers were 1~10. the pitch to diameter ratio were 1.3~5, and the inclination of the helical coil $0^{\circ}{\sim}90^{\circ}$. The measured $Nu_D$ for a single turn of the helical coil was very close to that from McAdams heat transfer correlation for a horizontal cylinder. The heat transfers of the helical coil were varied by the pith, number of turns, and duct height in a complex manner showing the velocity, chimney, and pre-heating effects. The results of the study contributes to the phenomenological analyses of the natural convection heat transfer of a compact heat exchanger.

Impact of Lumen Size and Helical Coil Place Change in Spring on Orthodontic Force (Spring의 lumen size와 helical coil 형성 위치 변화가 교정력에 미치는 영향)

  • Lee, Gyu-Sun;Lee, Sun-Kyoung;Kim, Bok-Dong
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.331-337
    • /
    • 2011
  • Purpose: The purpose of this study was to impact of force system change in finger spring that add helical coil one round on orthodontic force. Methods: The following conclusions were drawn from the experiment conducted after bending 90 samples with a CNC wire forming machine while changing the height and lumen size to 1mm - 3mm - 5mm and 2mm - 3mm - 4mm respectively in the coil of the force system in finger spring added with one wheel of helical coil of 18-8 stainless steel round wire (${\Phi}0.5mm$, spring hard) from Jinsung Co. in domestic market under the following conditions: Laboratory name = Instron 5942; Temperature($deg^{\circ}C$) = 18.00; Humidity(%) = 50.00; Rate 1 = 10.00000 mm/min; Compressive extension = 5.0mm. Results: When Coil height is 1, 3, 5mm and lumen size is 2, 3, 4mm reduce finger spring as mean value of compressive extension occasion maximum load(mN) increases as coil height rises, and lumen size grows to 5.0mm. And was expose that compressive load(mN) increases as coil position of finger spring rises and increase as lumen size is decrescent. Conclusion: As the adherence height of coil was raised from 1mm through 3mm to 5mm, compressive load increased. As the lumen size increased from 2mm through 3mm to 4mm, compressive load decreased. Therefore, these results suggest that it is desirable to lower the coil height and enlarge the lumen size to enhance the biomechanical efficiency of finger spring when manufacturing the finger spring for removable orthodontic devices.

Experimental Study on Compact type CO2 Gas Cooler(1) - Heat Flowrate and Pressure Drop in a Multi-Tube-In-Tube Helical Coil Type Gas Cooler - (CO2 가스쿨러용 콤팩트열교환기 개발에 관한 연구(1) -다중관식 헬리컬 코일형 가스냉각기내 CO2의 열유량과 압력강하-)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.30-36
    • /
    • 2010
  • The heat flowrate and pressure drop of $CO_2$ in a multi-tube-in-tube helical coil type gas cooler were investigated experimentally. The mass flowrate of $CO_2$ and coolant were varied from 0.06 to 0.075 [kg/s], respectively and the cooling pressure of gas cooler were from 8 to 10 [MPa]. The heat flowrate of $CO_2$ in the test section is increased with the increase in mass flowrate of coolant, the cooling pressure and mass flowrate of $CO_2$. The pressure drop of $CO_2$ is decreased with the decrease in mass flowrate of coolant and $CO_2$, but decreased with increase in cooling pressure of $CO_2$. The heat flowrate of $CO_2$ in the multi-tube-in-tube helical coil type gas cooler is greatly higher than that of $CO_2$ in the double pipe type gas cooler, while the pressure drop of $CO_2$ in the multi-tube-in-tube helical coil type gas cooler is greatly lower than that of $CO_2$ in the double pipe type gas cooler. Therefore, in case of the application of $CO_2$ at the multi-tube-in-tube helical coil type gas cooler, it is expected to carry out the high-efficiency, high-performance and compactness of gas cooler.

A Very Low-Bit-Rate Analysis-by-Synthesis Speech Coder Using Zinc Function Excitation (Zinc 함수 여기신호를 이용한 분석-합성 구조의 초 저속 음성 부호화기)

  • Seo Sang-Won;Kim Jong-Hak;Lee Chang-Hwan;Jeong Gyu-Hyeok;Lee In-Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.6
    • /
    • pp.282-290
    • /
    • 2006
  • This paper proposes a new Digital Reverberator that models Analog Helical Coil Spring Reverberator for guitar amplifiers. While the conventional digital reverberators are proposed to provide better sound field mainly based on room acoustics, no algorithm or analysis of digital reverberators those model Helical Coil Spring Reverberator was proposed. Considering the fact that approximately $70{\sim}80$ percent of guitar amplifiers are still with Helical Coil Spring Reverberator, research was performed based not on Room Acoustics but on Helical Coil Spring Reverberator itself as an effector. After performing simulations with proposed algorithm, it was confirmed that the Digital Reverberator by proposed algorithm provides perceptually equivalent response to the conventional Analog Helical Coil Spring Reverberators.

Conformational Transition of Poly(γ-benzyl-L-glutamate)-Poly(ethylene glycol) Block Copolymers in Bulk

  • Choi, Young-Wook;Park, Young-Mi;Choo, Jae-Bum;Cho, Chong-Su;Sohn, Dae-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.795-799
    • /
    • 2007
  • The bulk properties of poly(γ-benzyl-L-glutamate)-poly(ethylene glycol), PBLG-PEO, diblock copolymer were investigated. The helical transition from 7/2 to 13/5 for pure PBLG was at 120 oC while those of GE-1 and GE-2, which contain flexible PEO block 40 wt% and 60 wt% respectively, were shown at 135℃ on DSC experiments. FT-IR and XRD experiments were shown that the diblock copolymers maintained their α-helical structure in the temperature range between 25℃ and 175℃. Increasing relative size of coil part resulted in the increase of intermolecular packing distances. Due to well-maintained helical structure, lyotropic LC phases were observed for the PBLG-PEO block copolymer by the polarized optical microscope (POM). Especially, GE-3 copolymer, which has 12.5 wt% PEO contents, showed the smectic C phase. The competition of favorable aggregation energy between rod-rod and coil-coil, and unfavorable aggregation energy of rod-coil give rise to change the supramolecular structure in mixed solvent.

Design of a High Efficiency Resonator for Wireless Power Transfer (무선 전력 전송용 고효율 공진기 설계)

  • Jang, Yo-Han;Kwon, Jae-Soon;Park, Jae-Su;Choi, Jae-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.9
    • /
    • pp.820-826
    • /
    • 2011
  • In this paper, an efficiency improvement method in the wireless power transfer system based on magnetic resonance is proposed. A combined helical-spiral structure is adopted for self-resonant coil and source and device coils are designed using circular loop structure. The proposed resonator utilizing combined helical-spiral structure yields 13 % efficiency improvement over that of an existing helical type resonator when the transmitting and receiving coils are separated by 120 mm. In addition, the size can be reduced by 33 % comparing to the previous resonator.

Membrane interaction of the coiled-coil motif of HIV gp41 and its implication in the membrane fusion process

  • Jin, Bong-Suk;Yu, Yeon-Gyu
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 2003.06a
    • /
    • pp.58-58
    • /
    • 2003
  • The envelope glycoprotein of HIV, gp41, mediates the membrane fusion with human cells. The extracellular domain of gp41 has two helical regions. The N-terminus helical region (N-helix) forms trimeric coiled coil, interacts with the C-terminus helical region (C-helix) of gp41 to form a stable helical bundle structure. In this study, we have shown that the N-helix of gp41 has membrane interacting and disrupting abilities. It was localized into the interface of the lipidic phase and head group of the membrane. In contrast, the N-helix region with membrane fusion defective mutations could not bind to membrane. In addition, the N-helix bound on the membrane was released from the membrane by the C-helix, and the complex of the N- and C-helix did not interact with membrane. These results suggested that the membrane binding ability of the N-helix is necessary for the fusion activity of gp41, and such property is possibly controlled by the C-helm.

  • PDF

Study on Arrangement of Self-Resonant Coils in Wireless Power Transfer System Based on Magnetic Resonance (자기 공명 무선 전력 전송 시스템에서 공진 코일의 배열에 관한 연구)

  • Kim, Jin-Wook;Ji, Hyeon-Ho;Choi, Yeon-Gyu;Yun, Young-Hyun;Kim, Kwan-Ho;Park, Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.564-572
    • /
    • 2010
  • In this paper, characteristics on arrangement of coils in the wireless power transfer system based on magnetic resonance is presented. A helical structure is used for a self-resonant coil. To design a proper self-resonant helical coil, its inductance and capacitance are obtained. Using the finite element method, the self-resonant coil designed is simulated and characteristics of wireless power transfer with various arrangement between Tx and Rx resonant coils is analyzed. For verification, a prototype of a wireless power transfer system based on magnetic resonance is fabricated and efficiency of different arrangement such as both vertical and parallel arrangements is measured. From the measurement, transmission efficiency of 50 % for parallel arrangement is obtained within twice the diameter of the coil while for the vertical arrangement it is measured within one and a half diameter of the coil. Maximum efficiency of 84.25 % is observed at the distance 40 cm from the resonant coil in the case of parallel arrangement.

A three-region movable-boundary helical coil once-through steam generator model for dynamic simulation and controller design

  • Shifa Wu;Zehua Li;Pengfei Wang;G.H. Su;Jiashuang Wan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.460-474
    • /
    • 2023
  • A simple but accurate mathematical model is crucial for dynamic simulations and controller design of helical coil once-through steam generator (OTSG). This paper presents a three-region movable boundary dynamic model of the helical coil OTSG. Based on the secondary side fluid conditions, the OTSG is divided into subcooled region (two control volumes), two-phase region (two control volumes) and superheated region (three control volumes) with movable boiling boundaries between each region. The nonlinear dynamic model is derived based on mass, energy and momentum conservation equations. And the linear model is obtained by using the transfer function and state space transformation, which is a 37-order model of five input and three output. Validations are made under full-power steady-state condition and four transient conditions. Results show good agreements among the nonlinear model, linear model and the RELAP5 model, with acceptable errors. This model can be applied to dynamic simulations and controller design of helical coil OTSG with constant primary-side flow rate.