• 제목/요약/키워드: Height and location

검색결과 677건 처리시간 0.03초

Factors Affecting Cage Obliquity and the Relationship between Cage Obliquity and Radiological Outcomes in Oblique Lateral Interbody Fusion at the L4-L5 Level

  • CheolWon Jang;SungHwan Hwang;Tae Kyung Jin;Hyung Jin Shin;Byung-Kyu Cho
    • Journal of Korean Neurosurgical Society
    • /
    • 제66권6호
    • /
    • pp.703-715
    • /
    • 2023
  • Objective : This retrospective study investigated the factors that affect cage obliquity angle despite orthogonal maneuvers performed during oblique lateral interbody fusion (OLIF) and assessed the relationship between cage obliquity angle and radiological outcomes post-surgery. Methods : Twenty-nine males who underwent L4-L5 OLIF for lumbar degenerative disease between 2019 and 2021 with a followup duration greater than 12 months were analyzed. Radiological parameters were measured including psoas muscle volume, total psoas area index (total psoas muscle area [cm2]/height squared [m2]), distance from the iliac artery to the origin of the psoas muscle (DIAPM), angle between the origin of the psoas muscle and the center of the vertebral disc (APCVD), iliac crest height, disc height, lumbar flexibility (lumbar flexion angle minus extension angle), cage location ratio, cage-induced segmental lumbar lordosis (LL) (postoperative index level segmental LL minus used cage angle), foraminal height changes, fusion grade. Results : DIAPM, APCVD, iliac crest height, postoperative index level segmental LL, and cage-induced segmental LL were significantly correlated with OLIF cage obliquity angle. However, other radiological parameters did not correlate with cage obliquity. Based on multiple regression analysis, the predictive equation for the OLIF cage obliquity angle was 13.062-0.318×DIAPM+0.325×1APCVD+0.174×iliac crest height. The greater the cage obliquity, the smaller the segmental LL compared to the cage angle used. Conclusion : At the L4-L5 level, OLIF cage obliquity was affected by DIAPM, APCVD, and iliac crest height, and as the cage obliquity angle increases, LL agnle achievable by the used cage could not be obtained.

The Radiation Exposure of Radiographer Related to the Location in C-arm Fluoroscopy-guided Pain Interventions

  • Chang, Young Jae;Kim, Ah Na;Oh, In Su;Woo, Nam Sik;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • 제27권2호
    • /
    • pp.162-167
    • /
    • 2014
  • Background: Although a physician may be the nearest to the radiation source during C-arm fluoroscope-guided interventions, the radiographer is also near the fluoroscope. We prospectively investigated the radiation exposure of radiographers relative to their location. Methods: The effective dose (ED) was measured with a digital dosimeter on the radiographers' left chest and the side of the table. We observed the location of the radiographers in each procedure related to the mobile support structure of the fluoroscope (Groups A, M and P). Data about age, height, weight, sex, exposure time, radiation absorbed dose (RAD), and the ED at the radiographer's chest and the side of the table was collected. Results: There were 51 cases for Group A, 116 cases for Group M and 144 cases for Group P. No significant differences were noted in the demographic data such as age, height, weight, and male to female ratio, and exposure time, RAD and ED at the side of the table. Group P had the lowest ED ($0.5{\pm}0.8{\mu}Sv$) of all the groups (Group A, $1.6{\pm}2.3{\mu}Sv$; Group M, $1.3{\pm}1.9{\mu}Sv$; P < 0.001). The ED ratio (ED on the radiographer's chest/ED at the side of the table) of Group A was the highest, and the ED radio of Group P was the lowest of all the groups (Group A, $12.2{\pm}21.5%$; Group M, $5.7{\pm}6.5%$; Group P, $2.5{\pm}6.7%$; P < 0.001). Conclusions: Radiographers can easily reduce their radiation exposure by changing their position. Two steps behind the mobile support structure can effectively decrease the exposure of radiographers by about 80%.

Empirical Correlations for Breakup Length of Liquid Jet in Uniform Cross Flow-A Review

  • No, Soo-Young
    • 한국분무공학회지
    • /
    • 제18권1호
    • /
    • pp.35-43
    • /
    • 2013
  • The empirical correlations for the prediction of breakup length of liquid jet in uniform cross flow are reviewed and classified in this study. The breakup length of liquid jets in cross flow was normally discussed in terms of the distances from the nozzle exit to the column breakup location in the x and y directions, called as column fracture distance and column fracture height, respectively. The empirical correlations for the prediction of column fracture distance can be classified as constant form, momentum flux ratio form, Weber number form and other parameter form, respectively. In addition, the empirical correlations for the prediction of column fracture height can be grouped as momentum flux ratio form, Weber number form and other parameter form, respectively. It can be summarized that the breakup length of liquid jet in a cross flow is a basically function of the liquid to air momentum flux ratio. However, Weber number, liquid-to-air viscosity ratio and density ratio, Reynolds number or Ohnesorge number were incorporated in the empirical correlations depending on the investigators. It is clear that there exist the remarkable discrepancies of predicted values by the existing correlations even though many correlations have the same functional form. The possible reasons for discrepancies can be summarized as the different experimental conditions including jet operating condition and nozzle geometry, measurement and image processing techniques introduced in the experiment, difficulties in defining the breakup location etc. The evaluation of the existing empirical correlations for the prediction of breakup length of liquid jet in a uniform cross flow is required.

고령자 및 장애인을 위한 승강형 주방 상부장 설계 (Design of lift-down kitchen cabinet for elderly and disabled)

  • 심기범;심훈;임건혁;장지원;김상현
    • 문화기술의 융합
    • /
    • 제10권1호
    • /
    • pp.465-470
    • /
    • 2024
  • 주방 상부장은 수납공간이 넓고 작업 공간 활용도가 높다는 장점으로 인해 널리 사용되고 있지만 높은 곳에 설치되어 있어 고령자나 장애인이 접근하기 어려운 단점이 있다. 따라서 본 논문에서는 기존 상부장의 기능을 유지하면서 더욱 쉽고 안전하게 사용할 수 있도록 개별 층의 높이가 조절되는 새로운 방식의 상부장 구조를 제안한다. 효율적인 주방 공간 활용을 위한 상부장 설치 범위와 신체적 약자들이 접근할 수 있는 최대 높이를 고려하여 상부장 필요 하강 범위를 설정하였으며 선택한 개별 층이 최적의 경로를 따라 안전하게 하강할 수 있도록 기구설계 과정을 통해 적절한 복합 링크기구 형상과 치수 및 링크 구동 방법을 선정하였다. 또한, 모터 및 소프트웨어를 추가하여 간단한 버튼 조작으로 사용자가 원하는 높이로 내려올 수 있게 하였으며 실제 제작을 통해 제시된 승강형 링크기구의 안정성 및 높이 조절 성능을 검증하였다.

날개형 및 격막형 배플을 이용한 유체저장탱크 내부의 슬로싱 저감 연구 (A Study on the Reduction of the Sloshing of Storage Tank Using Wing and Diaphragm Baffle)

  • 이영신;김현수;이재형;김영완;고성호
    • 대한기계학회논문집A
    • /
    • 제27권12호
    • /
    • pp.2039-2046
    • /
    • 2003
  • Storage tank filled with fluid has unique dynamic characteristics compared to general structures, due to the interaction between fluid and structure. The oscillation of the fluid surface caused by external forces is called sloshing, which occurs in moving vehicles with contained liquid masses, such as trucks, railroad cars, aircrafts, and liquid missles. In this study, the evaluation method for the reduction of sloshing, the optimized size and location of wing and diaphragm baffles are suggested based on the experimental results. The experimental device can simulate the translation motion. A rectangular tank and various baffles are fabricated to study on the sloshing characteristics. The forces measured using the load cell at tank wall and those are compared with each other through the Fourier transformation for various conditions. The study of the sloshing of the rectangular tank equipped with baffles is conducted under the same conditions with non-baffled rectangular tank experiment. From the experimental results, the sloshing reduction effect by the baffles is observed. In conclusion in case of diaphragm baffles, the optimized size ratio of the width of baffle to the water height is 0.44 and the installation location has no effect to the damping of sloshing. In case of wing baffles, the optimized size ratio of the width of baffle to the length of a rectangular tank is 0.1 and the optimized location ratio of the baffle to the water height is 0.9.

지상기준점 선점 위치에 따른 DSM 높이 정확도 분석 (Quality Assessment of Digital Surface Model Vertical Position Accuracies by Ground Control Point Location)

  • 이종필
    • 지적과 국토정보
    • /
    • 제51권1호
    • /
    • pp.125-136
    • /
    • 2021
  • 최근 초경량무인비행장치(UAV)의 활용과 영상처리 기술 발달로 인해 정사영상과 수치모형 등을 활용한 응용 분야가 다양해지고 있다. 특히 토지측량분야에서도 이러한 결과물을 활용하여 위험지역분석과 같은 공간정보 활용이 활발해지고 있다. 본 연구에서는 UAV 고해상도 영상을 활용하여 고저차가 심한 경사지에서 정사영상의 위치정확도와 수치표면모델의 수직위치 정확도를 분석하고자 하였다. 연구 결과 대상지역 전역에 고르게 분포한 지상기준점(GCP)인 경우 2차원 정사영상에서 평면위치 오차는 크지 않았다. DSM의 수직위치의 경우 GCP의 선점위치를 점 간 고도차를 약 10m, 20m, 30m, 40m로 구분하여 전체를 포괄하는 각 8점의 GCP와 검사점을 대상으로 분석한 결과 비행코스별 고르게 분포되고 GCP 점 간 높이차가 30m일 경우(RMSEZ=0.07m) 가장 높은 정확도를 보였다. 본 연구지역과 유사한 대상지역을 UAV를 활용하여 수치모형을 제작할 경우 GCP 위치선정과 수직위치 정확도 향상에 도움이 될 수 있기를 기대한다.

단일 단순수직통로의 연돌효과와 중성대에 관한 수치해석 연구 (A Numerical Study on the Stack Effect and the Neutral Plane of a Single Simplified Shaft)

  • 전흥균;최영상;추홍록
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.143-152
    • /
    • 2009
  • 초고층건물의 수직통로에서 발생하는 연돌효과의 기체역학적 특성과 관련된 차압과 중성대의 위치 계산 및 연돌효과 발생의 가시화를 위하여 3가지 형태의 개구부를 갖는 단일 단순수직통로에 대하여 CFD 모델을 사용하여 수치해석을 하였다. 연돌효과의 차압은 이론식 계산 결과와 비교 시 수직통로의 높이가 높아질수록 차이가 커진다. 중성대 위치는 연돌효과 초기(t = 10s)에 Type A의 경우 수직통로의 높이가 30m 미만인, Type B의 경우 30m 이상인 모델에서 이론식 계산 결과와의 편차가 5% 미만으로 잘 일치한다. 따라서 수직통로 높이가 30m 이상인 다중개구부 수직통로(Type B)의 경우 CFD 모델을 사용하여 중성대 위치를 계산하는 것이 가능하다. 연돌효과의 가시화를 통하여 연돌효과의 공기 유동 현상을 쉽게 이해할 수 있다.

초음파 펄스 에코 패턴으로 용접 결함 식별 방법 연구 (Study of the Weld Defects Identification Method by Ultrasonic Pulse Echo Patterns)

  • 김원중
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6114-6118
    • /
    • 2013
  • 본 연구에서는 초음파 탐상시험의 펄스 반사법으로 각각 용접결함에 따른 초음파 펄스파형모형을 연구하였다. 균열은 예리하고 선명한 신호들을 발생한다. 탐촉자를 결함주위로 이동하면 에코높이는 변한다. 긴 균열에서는 탐촉자가 결함 주위를 원형으로 목돌림주사법을 사용하여 탐상하면 에코높이는 급격히 감소한다. 그 에코 봉우리는 바늘과 같이 얇고 날카롭다. 기공은 단일 결함으로부터 발생하는 에코는 예리하고 선명하다 하지만 집단의 기공들은 다수의 반사들이 중첩되고 트레이스가 들쭉날쭉한 에코가 발생한다. 슬래그 개재물은 크랙과 슬래그 결함위치에서 각각 목돌림 주사법을 사용하여 탐상하면 그 에코형상은 어느 정도 차이를 볼 수 있었다. crack은 그 에코높이가 급격히 변하는 반면에 슬래그 개재물은 증가${\rightarrow}$감소${\rightarrow}$증가${\rightarrow}$감소된다. 또한 다수 밀집된 기공의 위치에서 결함은 대표적 에코형상과 같은 잡다한 에코형상은 슬래그에서는 볼 수 없었다. 용입불량은 결함의 에코형상은 크랙과 같이 날카롭고 예리하게 나타났고, crack과 비슷한 에코형상은 갖고 있었다.

COMPARISON OF DRYOUT POWER DATA BETWEEN CANFLEX MK-V AND CANFLEX MK-IV BUNDLE STRINGS IN UNCREPT AND CREPT CHANNELS

  • JUN JI SU;LEUNG L.K.H.
    • Nuclear Engineering and Technology
    • /
    • 제37권6호
    • /
    • pp.565-574
    • /
    • 2005
  • The CANFLEX Mk-V bundle is designed to improve upon the critical heat flux (CHF) characteristics of the CANFLEX Mk-IV bundle. The main difference between these two bundles is an increase in bearing pad height of about 0.3 mm in the CANFLEX Mk-IV bundle. This change in bearing pad height leads to an increase in gap flow at the bottom of the bundle, primarily eliminating the localized narrow-gap effect that limits the CHF of the CANFLEX Mk-IV bundle. The objective of this paper is to examine the effects of bearing pad height and pressure tube creep on the sheath-temperature distribution, dryout power, and dryout location, as observed ken full-scale bundle tests, between CANFLEX Mk-IV and Mk-V bundles In uncrept and crept channels. A comparison of surface-temperature differences between the top and bottom elements of the bundles showed that increasing the bearing pad height has led to a more homogeneous enthalpy distribution in subchannels of the bundle. Initial dryout locations of the CANFLEX Mk-V bundle were mainly observed at the mid-spacer plane of either the $10^{th}$ (about $80\%$) or $11^{th}$ ($20\%$) bundle in the 12-bundle string, as compared to the mid-spacer and downstream-button planes for the CANFLEX Mk-IV bundle. Dryout power and boiling-length-average (BLA) CHF values exhibit consistent trends and little scatter with varying flow conditions for both types of CANFLEX bundles in uncrept and crept channels. An increase in pressure tube creep has led to a reduction in dryout power (about $20\%$ far the $3.3\%$ crept channel and $27\%$ for the $5.1\%$ crept channel as compared to dryout powers for the uncrept channel). Increasing the bearing pad height of the CANFLEX bundle has led to an increase in the dryout power. Overall, the dryout power of the CANFLEX Mk-V bundle is 7 to $10\%$ higher than that of the CANFLEX Mk-IV bundle at the inlet temperature range of interest (i.e., between 243 and $290^{\circ}C$).

강판셀 호안의 변형특성 (Deformation Characteristics of Steel Plate Cellular Bulkhead)

  • Jeong Wook Kang
    • 한국해안해양공학회지
    • /
    • 제9권4호
    • /
    • pp.165-175
    • /
    • 1997
  • 본 연구에서는 재하높이와 근입비를 달리하는 근입식 강판셀의 모형실험을 실시하여 셀 구조물의 변형특성에 미치는 재하높이와 근입비의 영향을 정성적으로 검토하였다. 또한, 채움재로 알루미늄 봉을 이용한 2차원 모형실험을 수행하여 채움재의 전단거동에 미치는 재하높이의 영향을 검토하고, Hansen의 토압이론에 근거하여 실험치와 이론치를 비교·검토하였다. 그 결과, 재하높이와 근입비에 따라 셀의 항복모벤트가 달라진다는 사실을 확인할 수 있었으며, 활동면은 재하높이가 낮아짐에 따라 셀 내부의 보다 낮은 곳에 위치함을 알 수 있었다. 그리고 Hansen의 토압이론에 의하여 이론적인 고찰을 수행한 결과, 실험치와 이론치는 비교적 잘 일치하였으며, 재하높이에 따른 활동면의 위치변화에 대해서는 동일한 결과를 얻었다.

  • PDF