• Title/Summary/Keyword: Height Determination

Search Result 344, Processing Time 0.026 seconds

Development of a Site Productivity Index and Yield Prediction Model for a Tilia amurensis Stand (피나무의 임지생산력지수 및 임분수확모델 개발)

  • Sora Kim;Jongsu Yim;Sunjung Lee;Jungeun Song;Hyelim Lee;Yeongmo Son
    • Journal of Korean Society of Forest Science
    • /
    • v.112 no.2
    • /
    • pp.209-216
    • /
    • 2023
  • This study aimed to use national forest inventory data to develop a forest productivity index and yield prediction model of a Tilia amurensis stand. The site index displaying the forest productivity of the Tilia amurensis stand was developed as a Schumacher model, and the site index classification curve was generated from the model results; its distribution growth in Korea ranged from 8-16. The growth model using age as an independent variable for breast height and height diameter estimation was derived from the Chapman-Richards and Weibull model. The Fitness Indices of the estimation models were 0.32 and 0.11, respectively, which were generally low values, but the estimation-equation residuals were evenly distributed around 0, so we judged that there would be no issue in applying the equation. The stand basal area and site index of the Tilia amurensis stand had the greatest effect on the stand-volume change. These two factors were used to derive the Tilia amurensis stand yield model, and the model's determination coefficient was approximately 94%. After verifying the residual normality of the equation and autocorrelation of the growth factors in the yield model, no particular problems were observed. Finally, the growth and yield models of the Tilia amurensis stand were used to produce the makeshift stand yield table. According to this table, when the Tilia amurensis stand is 70 years old, the estimated stand-volume per hectare would be approximately 208 m3 . It is expected that these study results will be helpful for decision-making of Tilia amurensis stands management, which have high value as a forest resource for honey and timber.

Experimental Study on the Determination of Slope and Height of Curbs Considering the VRUs (교통약자를 고려한 보도의 경사도와 높이 결정을 위한 실험연구)

  • Kim, Hyunjin;Lim, Joonbeom;Choe, Byongho;Oh, Cheol;Kang, Inhyeng
    • International Journal of Highway Engineering
    • /
    • v.20 no.1
    • /
    • pp.107-115
    • /
    • 2018
  • PURPOSES : As the population of the mobility handicapped, who are classified as the disabled, the elderly, pregnant women, children, etc., has increased, the voices for guaranteeing their rights have been increasing as well. Thus, the design manuals for roads and sidewalks for the mobility handicapped were developed by the local government, such as the Ministry of Land, Transport, and Tourism, in Seoul City. However, according to the 2013 survey results of the Seoul Metropolitan City, the mobility handicapped still feel uncomfortable with the sidewalks, and particularly request for the improvement of the step and slope of the sidewalk curb. Therefore, in this study, we conducted an empirical experimental study to determine the slope of the sidewalk curb and height of the steps considering the mobility handicapped and analyzed whether there is a statistically significant difference. METHODS : The methodology of this study is an empirical experimental one. In the study, five non-disabled people, 10 wheelchair users, and 10 eye patch and stick users walked about 2-3 min on the sidewalk plates of the sloped type (0%, 5%, 6.3%, 8.3%) and stepped type (0 cm, 1 cm, 3 cm, 6 cm), and their human physiological responses, such as the skin temperature, volume of perspiration on forehead and chest, and heart rate, were measured and recorded. After combining the data, we conducted a nonparametric test, ANOVA, or t-test to determine whether there was a statistically significant difference according to each slope and step type. RESULTS : It was found that for the non-disabled, there was no significant difference in human physiological responses according to the slope and steps of the sidewalk. It can be said that the non-disabled do not feel much physiological discomfort while walking. In the case of the sloped sidewalk plate, the heart rate of the wheel chair users increased when the slope was 6.3%. In the case of the eye patch and stick users, the volume of perspiration on the chest increased at a slope of 5.0%. In general, it is judged that a sidewalk with a slope that is less than 5% does not cause a change in the physiological response. In the case of a stepped sidewalk plate, when 0 cm, 1 cm, and 3 cm were compared for wheelchair users, the amount of forehead perspiration increased from 1 cm. Meanwhile, in the case of the eye patch and stick users, when 0 cm and 6 cm were compared, the amount of perspiration on the forehead and chest as well as the heart rate all increased at 6 cm. Taken together, in the case of wheelchair users, a difference was shown when the height of the step of the sidewalk plate was 1 cm, suggesting that installing it at 0 cm does not cause any physiological discomfort. Moreover, in the case of the eye patch and stick users, when comparing only 0 cm and 6 cm, 0 cm was considered to be suitable, as there was a difference in physiological response at 6 cm. CONCLUSIONS : In this study, we set the human physiological responses such as chest skin temperature, amount of perspiration, and heart rate as evaluation items, and our study was considered to be a meaningful experiment that targeted wheelchair users as well as eye patch and stick users. The validity of the evaluation items was confirmed, as the results of human physiological responses were significant. As for the sidewalk design, according to the experiment result, it is considered that differential application should be implemented according to the type of mobility handicap, rather than uniformly applying a sidewalk step of 2 cm and sidewalk slope of 1/25, which are the current legal standards.

Allometric equations, stem density and biomass expansion factors for Cryptomeria japonica in Mount Halla, Jeju Island, Korea

  • Jung, Sung Cheol;Lumbres, Roscinto Ian C.;Won, Hyun Kyu;Seo, Yeon Ok
    • Journal of Ecology and Environment
    • /
    • v.37 no.4
    • /
    • pp.177-184
    • /
    • 2014
  • This study was conducted to develop allometric equations and to determine the stem density and biomass expansion factor (BEF) for the estimation of the aboveground and belowground biomass of Cryptomeria japonica in Jeju Island, Korea. A total of 18 trees were harvested from the 40-year-old C. japonica stands in Hannam experimental forest, Jeju Island. The mean biomass of the C. japonica was $50.4Mg\;ha^{-1}$ in stem wood, $23.1Mg\;ha^{-1}$ in root, $9.6Mg\;ha^{-1}$ in branch, $4.6Mg\;ha^{-1}$ in needle and $4.3Mg\;ha^{-1}$ in stem bark. The diameter at breast height (DBH) was selected as independent variable for the development of allometric equations. To evaluate the performance of these equations, coefficient of determination ($R^2$) and root mean square error (RMSE) were used and results of the evaluation showed that $R^2$ ranged from 71% (root biomass equation) to 96% (aboveground biomass equation) and the RMSE ranged from 0.10 (aboveground biomass equation) to 0.33 (root biomass equation). The mean stem density of C. japonica was $0.37g\;cm^{-3}$ and the mean aboveground BEF was $1.28g\;g^{-1}$. Furthermore, the ratio of the root biomass to aboveground biomass was 0.32.

Determination of Corneal Aberrations Using Corneal Shape of Topographer (각막지형검사기의 각막형상을 이용한 각막수차 구현)

  • Park, Seong-Jong;Kim, Sun-Young;Han, Kyung-Soo;Joo, Seok-Hee;Chun, Young-Yun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: In this study a program was developed to determine corneal aberrations using corneal shape of topographer and represented a wavefront and corneal aberrations using zernike polynomial. Methods: When the pupil size was 6 mm, we calculated new corneal shape data with zernike polynomials using corneal shape data of ORBSCAN topographer. We programmed the wavefront construction using ray tracing for corneal shape, then represented corneal aberrations having zernike polynomial with 6th order and 28 terms. Conclusions: We developed programs to determine a wavefront and corneal aberrations using corneal shape of ORBSCAN topographer. Theses results will be applied to a development of new topographer and prescription of contact lens and OK lens.

  • PDF

A Comparison of the Results from Somatotype Evaluation with Different Evaluation Tools

  • Choi, Wan-Suk;Choi, Jung-Hyun;Cho, Mi-Suk;Moon, Ok-Kon;Park, Joo-Hyun;Chung, Hyung-Kuk;Lee, Suk-Hee;Lee, Jung-Sook;Min, Kyung-Ok
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.1 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • Supposing that somatotype evaluation results would have significant differences between the public group with less amounts of exercises and the special group with intensive exercises for three to four times a day, this study aimed at comparing the mutual consistency between the results determined by somatotype evaluation tools such as visually calculated index(VCI), R$\ddot{o}$hrer's Index(RI) and Body Mass Index(BMI). The public, taekwondo players and judo players groups were composed of fifty persons, taekwondo players and judo players passed through VCI determination, respectively. Their height and weight were examined and analyzed with somatotype evaluation tools. Comparison of somatotype dispersion of RI and VCI showed that most women were determined by VCI as lean type but were determined by RI as normal type. And that women were determined by VCI as fat type but were determined by RI as normal type. Therefore both men and women showed significant differences in VCI and RI. Comparison of somatotype dispersion of VCI and BMI showed that both men and women were overestimated or underestimated by VCI rather than by BMI. Comparison of somatotype dispersion of RI and BMI showed that men were less determined by BMI as lean type compared with women; both men and women less determined by BMI rather than by RI as normal type; and both men and women, in particular, were more determined by BMI as fat type but men were more determined by BMI rather than by RI as fat type. Total somatotype consistency by tools showed that VCI has the greatest possibility of determining the public group, compared with other groups as lean type and that the consistency of the three tools were relatively higher for the taekwondo players and judo players groups, compared with the public.

  • PDF

Directivity Analysis of Ultrasonic Wave Reflected from the Artificial Defect in Simulated Butt Welded Joint (가상 용접부내의 결함으로부터 반사된 초음파의 지향성 해석)

  • Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.2
    • /
    • pp.378-385
    • /
    • 1995
  • The ultrasonic non-destructive testing uses the directivity of the ultrasonic pulse wave which propagates in one direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of ultrasonic wave is closely related to determination of probe arrangement, testing sensitivity, scanning pitch and defect location and characterization. The paper measured the directivity of shear wave, which reflected from artificial defect located in weld metal zone in butt welded joint similar model made of pyrex glass by using visualization method. 2 MHz and 4 MHz angle probes were used to measure the directivity of reflection wave at the artificial defect. The directivity of shear waves reflected from the defect was different according to the probe position and the shape of butt welded joint. The difference of directivity of reflection wave was existed between 2 MHz and 4 MHz angle probes. The angle of reflection wave became equal to angle of incidence as increase of the height of excess metal.

  • PDF

Predicting residual moment capacity of thermally insulated RC beams exposed to fire using artificial neural networks

  • Erdem, Hakan
    • Computers and Concrete
    • /
    • v.19 no.6
    • /
    • pp.711-716
    • /
    • 2017
  • This paper presents a method using artificial neural networks (ANNs) to predict the residual moment capacity of thermally insulated reinforced concrete (RC) beams exposed to fire. The use of heat resistant insulation material protects concrete beams against the harmful effects of fire. If it is desired to calculate the residual moment capacity of the beams in this state, the determination of the moment capacity of thermally insulated beams exposed to fire involves several consecutive calculations, which is significantly easier when ANNs are used. Beam width, beam effective depth, fire duration, concrete compressive and steel tensile strength, steel area, thermal conductivity of insulation material can influence behavior of RC beams exposed to high temperatures. In this study, a finite difference method was used to calculate the temperature distribution in a cross section of the beam, and temperature distribution, reduction mechanical properties of concrete and reinforcing steel and moment capacity were calculated using existing relations in literature. Data was generated for 336 beams with different beam width ($b_w$), beam account height (h), fire duration (t), mechanical properties of concrete ($f_{cd}$) and reinforcing steel ($f_{yd}$), steel area ($A_s$), insulation material thermal conductivity (kinsulation). Five input parameters ($b_w$, h, $f_{cd}$, $f_{yd}$, $A_s$ and $k_{insulation}$) were used in the ANN to estimate the moment capacity ($M_r$). The trained model allowed the investigation of the effects on the moment capacity of the insulation material and the results indicated that the use of insulation materials with the smallest value of the thermal conductivities used in calculations is effective in protecting the RC beam against fire.

Application of Quantitative X-ray Diffraction Analysis for Unburned Coal Content on Coke-Char-Sinter Mixtures (고온에서 발생한 코크스-미연소탄-소결광의 혼합물 중 미연소탄의 정량화를 위한 분말 X-선 회절법 적용)

  • 김재명;정진경;김성만;허완욱;김형순
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.5
    • /
    • pp.481-487
    • /
    • 2003
  • A technique for determination of proportions of char, coal ana coke is needed in order to monitor pulverized coal injection performance in operating blast furnace. Quantitative X-ray powder diffraction analysis can be applied to the problem providing that structural information on carbonaceous materials, coal, char, coke and their mixture are known. Chars were prepared from a coal at different temperatures (1000∼1400$^{\circ}C$) and were characterised by X-Ray powder Diffraction (XRD). The XRD result gave crystallite size (height Lc and diameter, La), aromaticity, number of (002) plane in carbon, and d-spacing. As a result, with increasing heat treat temperature of char, Lc$_{(002)}$, La$_{(10)}$ and number of (002) plane in carbon were increased, and d-spacing and FWHM(Full With Half Maximum) were decreased. Result of prediction of amount of char from the mixtures (char, coke and ore) based on the Lc$_{(002)}$ information of two mixtures (coke and char) showed very close values expected.

A study on the Determination of Trace Se and Bi in the Scalp Hair by Hydride Generation- Inductively Coupled Plasma Atomic Emission Spectrometry (수소화물발생 유도결합플라즈마 원자방출분광법에 의한 머리카락 시료 중 미량의 Se와 Bi의 분석에 관한 연구)

  • Choi, Beom Suk;Lee, Dong Kee
    • Analytical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.26-34
    • /
    • 1996
  • A method to determine the trace amount of Se and Bi in the scalp hair using the hydride generation inductively coupled plasma atomic emmission spectrometry was studied. The optimum operation conditions of ICP for hydride generation are 0.6~0.8L/min for the carrier gas flow rate, and 6mm above the induction coil for the observation height. Hydrochloric acid concentrations for the optimum hydride generation conditions were greater than 1.5M when 2.5% $NaBH_4$ and NaOH were used, and greater than 0.5M when 2.5% $NaBH_4$ and 0.1% NaOH were used. Severe interference effects are observed from transition metals such as Cu and Ni, and they could be circumvented by the coprecipitation with lanthanum hydroxide.

  • PDF

The Analysis of Foot Shape of Elementary School Boys (학령기 남아의 발 형태 분석)

  • Seok, Eun-Yeong;Jeon, Eun-Gyeong;Park, Sun-Ji;Gwon, Suk-Hui
    • Journal of the Ergonomics Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.1-12
    • /
    • 2004
  • The purposes of this study were to investigate the relationship between anthropometric data of foot and other body sizes. to categorize the foot shape of elementary school boys and to find out determinant factors related the foot that enable us to deduce the foot shape and size for the design of more comfortable shoes. Subjects of this study were 249 elementary school boys of age ranged from 6 to 11 residing Seoul and lncheon area. Anthropometric sizes were measured with the direct measurement method using Martin scales and the indirect measurement method using digital photos. Pearson's correlation, factor analysis. cluster analysis. analysis of variance, post-hoc test, and cross tabs were performed for statistical analysis of the data by SPSS program. From the investigation on the relationship between foot-related items and body items, most items of foot measure were significantly related to body size items. However, angle of the foot did not related to other body sizes although other height items and mass items of the foot did have relationships with other body sizes. Results of ANOVA indicated there were significant differences in foot-related items except for items of foot angle and all body anthropometric items by subjects' age. This implicates big toe angle, little toe angle and foot ratio factors are required in sizing shoes besides foot length. On the basis of cluster analysis using factor scores. three different foot shapes were categorized. Type 1 was large and wide foot, Type 2 was small and narrow foot with large toe angle. and Type 3 was medium foot with no deformity on big toe. These three groups show significant differences in almost all measurement items. However, Rorher index and foot angle didn't show any significant differences among groups. This implicates the foot shape can be a determinant of shoe size.