• Title/Summary/Keyword: Heel Height

Search Result 148, Processing Time 0.031 seconds

Surgical Treatment of Achilles Tendon Rupture with Absorbable Suture Materials Only (흡수성 봉합사만를 이용한 아킬레스건 파열의 수술적 치료)

  • Bae, Su-Young;Park, Jae Gu;Jung, Eui Yub
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.3
    • /
    • pp.196-202
    • /
    • 2013
  • Purpose: To report the clinical results from using absorbable suture materials instead of nonabsorbable materials which have been used more commonly to repair Achilles tendon. Materials and Methods: We retrospectively reviewed 21 cases of acute Achilles tendon rupture, treated surgically from 2004 to 2011. Mean follow-up period is 6 months. We repaired Achilles tendon using size 1 Vicryl (Polyglactin 910, Ethicon) for core suture and size 3-0 Vicryl for epitendinous suture. At three months after surgery, we evaluated clinical results with single heel raise height by centimeters, differences of calf circumference and passive range of motion of ankle joint, compared to contralateral side. Also we recorded clinical results with subjective satisfaction grades. Results: At three months after surgery, 20 of 21 patients were able to perform single heel raise over 5 cm in height. Calf circumference differences were less than 1 cm in 12 cases, between 1 cm to 3 cm in 5 cases, more than 3 cm in 4 cases. There was no difference in range of passive motion in 19 cases. All patients satisfied with daily activity except 2 cases with mild discomfort. There was no complication such as rerupture, elongation or infection. Conclusion: We experienced excellent clinical results from repairing Achilles tendon with using absorbable suture materials in terms of functional outcomes and patient's satisfaction without any complication. So we may consider using absorbable suture materials instead of nonabsorbable materials to repair Achilles tendon.

Stability of the offshore large purseiner in Korea (한국 근해 대형 선망 어선의 복원성)

  • Ham, Sang-Jun;Kang, Il-Kwon;Kim, Hyung-Seok;Jo, Hyo-Jae;Kim, Jung-Chang
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.47 no.3
    • /
    • pp.241-247
    • /
    • 2011
  • Marine casualties of vessel are said to be in most case caused by human error, but it would be valid for the assumption that the ship is built with high quality and then should be acceptable to the safety standards. It means that the inherent characteristics of a ship should be the first consideration on the safety of ship. Therefore it is basically necessary for navigator to grasp the inherent stability of his ship and ensure that the ship complies with the minimum statutory standards of stability. This study is to realize the stability of the Korean offshore large purseiner varying with loading conditions by the inclining data and some calculations. The author compared the stability of the ship with IMO criteria and domestic rule, and proposed some improvement for the safety of the ship. The results are summarized as follows ; The values of GM of the ship according to the loading condition in navigation satisfy both of the IMO criteria and the domestic rule, but in case of the area under the GZ curves between the heel angles of $30^{\circ}$ and $40^{\circ}$, and the heel angle occuring the maximum righting lever not satisfy the IMO rule at the fishing ground departure and arrival conditions in the haul in net situation. The initial metacentric height of the ship is very large, but the range of stability and the occurring angle of the maximum GZ are very small, so even small inclining can bring about the beam end. The best method of improvement for that is to increase the freeboard of the model among the variables.

A Comparative Analysis of the Finger Pressure and Kinematic Variables in the Forehand Hairpin Net Shot According to Proficiency (배드민턴 포핸드 헤어핀 동작 시 숙련 정도에 따른 손가락 압력 및 운동학적 변인 비교 분석)

  • Lee, Haeng-Seob;Chae, Woen-Sik;Jung, Jea-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.4
    • /
    • pp.387-394
    • /
    • 2012
  • The purpose of this study was to compare and analyze the finger pressure and kinematic variables in the forehand hairpin net shot between skilled elite players and less skilled recreational players. Eight elite players(age: $18.1{\pm}0.8yrs$, height: $176.8{\pm}1.5cm$, weight: $640.9{\pm}48.6N$) with minimum of 6 years of experience and eight recreational players(age: $27.9{\pm}1.6yrs$, height: $177.1{\pm}6.1cm$, weight: $820.5{\pm}62.8N$) with less than one year experience were recruited in this study. For each trial being analyzed, four critical instants were identified from the video recordings: Right heel contact1 (E1), Right toe-off (E2), Right heel contact2 (E3), and Shuttlecock Impact (E4). Each hairpin net shot was broken into consecutive phases: E1~E2 (Right Landing Phase: RLP), E2~E3 (Sliding Step Phase: SSP), and E3~E4 (Impact Phase: IP). Temporal parameters, shuttlecock speed, linear and angular kinematics of body segments, and finger pressures were computed for this study. The results showed that The finger pressure of the ring finger and the middle finger for the skilled group during an impact had significantly greater than those of unskilled group. It is possible that all fingers were not used in the same manner when the racket was gripped in forehand hairpin. The result also suggested that the ring finger and the middle finger pushed the racket from top to bottom while having the mid-phalanx and proximal phalanx of index finger as an axis.

A Development of Pendulum Putting Machine for the Experiments of Putting Stroke (퍼팅 스트로크 실험용 진자퍼팅기 개발)

  • Park, Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.4
    • /
    • pp.147-152
    • /
    • 2006
  • The purpose of this study was to develop the experimental machine for the putting strokes. This experimental machine is called Pendulum Putting Machine(PPM). The height of PPM is 75cm and the mass is 10kg. To make the frame of this machine, 24 and 20 diameters of iron pipes were used. Bottom of the frame(bottom girdle) was made with circle shape and top of the frame(top girdle) was made with rectangular shape. Above the top girdle, iron plate($12{\times}17{\times}0.5cm$) was placed to connect the ball bearing. At the top of the frame two ball bearings with axis were placed for the diverse lies of putters and irons. To verify usefulness of this machine, experiments were executed with the PPM. Two major experimental conditions were hitting points(sweet spot, toe side, heel side) and hitting places(bottom, 3cm before bottom, 3cm after bottom). Eleven different cases were tested. The results showed that the diversity of the ball placement(distance and direction) was acceptable(distance range, 2.70-5.87 standard deviation; direction range, 1.71-4.65 standard deviation). Overall the Pendulum Putting Machine is very useful for the study of putting and driving strokes.

The Relationship among Stride Parameters, Joint Angles, and Trajectories of the Body Parts during High-Heeled Walking of Woman

  • Park, Sumin;Lee, Minho;Park, Jaeheung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.3
    • /
    • pp.245-252
    • /
    • 2013
  • Objective: This paper analyzes the changes on stride parameters, joint angles, and trajectories of the body parts due to high heels during walking and explains the causal relationship between the changes and high heels. Background: This study aims to indicate the comprehensive gait changes by high heels on the whole body for women wearing high heels and researchers interested in high-heeled walking. Method: The experiment was designed in which two different shoe heel heights were used for walking (1cm, 9.8cm), and twelve women participated in the test. In the experiment, 35 points on the body were tracked to extract the stride parameters, joint angles, and trajectories of the body parts. Results: Double support time increased, but stride length decreased in high-heeled walking. The knee inflexed more at stance phase and the spine rotation became more severe. The trajectories of the pelvis, the trunk and the head presented outstanding fluctuations in the vertical direction. Conclusion: The double support time and the spine rotation were changed to compensate instability by high heels. Reduced range of motion of the ankle joint influenced on the stride length, the knee flexion, and fluctuations of the body parts. Application: This study can provide an insight of the gait changes by high heels through the entire body.

Relationship between height of heels and quantitative EMG of lower leg, thigh and paralumbarvertebral muscles in young women (젊은여성의 구두굽의 높이와 하퇴근, 대퇴근 및 요추주위근 근전도와의 관계)

  • 최명애;김진호;이은용
    • Journal of Korean Academy of Nursing
    • /
    • v.18 no.1
    • /
    • pp.34-43
    • /
    • 1988
  • The present study has been undertaken to assess the electrical activity of right tibialis anterior, right gastrocnemius, right rectus femoris, right biceps femoris and right paralumbarvertebral muscles quantitatively by EMC while standing erect on the height of 0cm, 3cm, 5cm and 7cm heels. The inclinations of the heels were 0, 6, 11, 17 degrees, respectively. Foully young women ranging from 18 to 24 of age were examined. Electrical activity of various muscles while standing erect on the height of various heels were compared with that of 0cm heel. The results obtained were as follows : 1. Electrical activity of the tibialis anterior increased significantly as the height of heels became higher ; which was thought to be due to the effort to counteract the instability standing with high heels. 2. There was a significant increase in electrical activity of the gastrocnemius as the height of heels increased. It might be due to compensatory activity against shifting of the center of gravity forward. 3. There was a significant increase .in electrical activity of the rectus femoris and biceps femoris at the height of 3cm, 5cm and 7cm heels ; which seemed to be due to the effort to stabilize the knee joint. 4. Electrical activity of the paralumbarvertebral muscles increased significantly at the height of 5cm and 7cm heels ; which was considered to be due to the effort to prevent forward imbalance. From These results, it may be concluded that electrical activities of various postural muscles increase significantly while standing erect on the height of 3cm, 5cm and 7cm heels to counteract an instability of their posture and compensate the forward shifting tendency of the center of gravity.

  • PDF

The Effect of Insole Height on Lumbosacral Angle and Body Function in Male University Students

  • Lee, Young Sin;Yu, Seong Hun;Kim, Seong Su
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.4
    • /
    • pp.303-312
    • /
    • 2015
  • Objective: The aim of this study is to investigate the effect of insole height change in the lumbosacral angle and physical functions in healthy males. Background: In order to release male's dissatisfaction with his height and to increase satisfaction with his body, using insole is generalized. There have been researches on female's body change in accordance with function of insole and heel height, whereas there are few researches on males. Method: Participants were divided into three groups. A control group had 10 participants who wore 0cm insole. Experimental group I had 10 participants who wore 2cm insole. Experimental group II had 10 participants who wore 4cm insole. All participants wore insoles during their daily lives for a trial period of 8 weeks. The results were evaluated before and after comparison, and we measured lumbosacral angle, balance (dynamic balance, agility, quickness) and lumbar pain (LBP). Results: This study showed that insole height affected lumbosacral angle and dynamic balance and pain. In particular, there were significant differences in the 4cm group among the three groups (p<.05). The 2cm group did show a significant difference in lumbosacral angle and pain (p<.05). Furthermore, no significant difference was observed within the control group. Conclusion: The 4cm insole height suggests that the increase of lumbosacral angle contributes to some changes in LBP, balance, pain and physical functions, probably leading to negative effects on variety of activities of daily life. Application: The results of wearing insoles with proper height will help to prevent musculoskeletal disorders.

Comparison of the Effects of Different Crutch Length Measurement Methods on Trunk Muscle Activities in Young Females (젊은 여성의 몸통 근육 활성도 분석을 통한 목발 길이 측정 방법의 효율성 비교)

  • Jeon, Hyun;Oh, Duck-Won
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.1
    • /
    • pp.77-84
    • /
    • 2020
  • PURPOSE: This study compared the activities of the trunk muscles during crutch walking to determine which of the crutch length measurements is most beneficial. METHODS: Twenty young women volunteered to participate in this study. After adjusting crutch length, the participants performed a three-point walking with nondominant leg limited in weight bearing. This study used six crutch length measurements: (1) Height-40.6cm, (2) Height'.77, (3) Olecranon-to-finger length, (4) Axillary-toheel length, (5) Arm-span length-40.6cm, and (6) Arm-span length'.77. The EMG activities of the internal oblique (IO), rectus abdominis (RA), multifidus (MF), and erector spinae (ES), muscles on the weight bearing side were monitored using wireless surface EMG. RESULTS: The EMG activities of the RA and ES appeared to be significantly different among the crutch length measurements (p<.05). The post-hoc test showed that the 'Arm-span length-40.6cm' was significantly greater in the RA activity when compared to the 'Height'.77' and 'Axillary-to-heel length' measurements, and in the ES activity when compared to 'Height'.77' measurements. Furthermore, IO/RA and MF/ES ratios showed significant differences among the crutch length measurements (p<.05). In the post-hoc test, significant difference was observed between 'Olecranon-to-finger length' and 'Arm-span length-40.6cm' for the IO/RA ratio, and between 'Height'.77' and 'Olecranon-to-finger length' and between 'Height'.77' and 'Arm-span length-40.6cm' measurement for the MF/ES ratio. CONCLUSION: These findings suggest that the 'Height'.77' measurement is relatively advantageous to optimize the activities of trunk muscles during the crutch walking, and allow simple measurements of the crutch length.

Analysis of Middle Aged and Elderly Women's Foot Shapes for Shoe Design

  • Lim, Ho-Sun
    • Fashion & Textile Research Journal
    • /
    • v.17 no.5
    • /
    • pp.815-827
    • /
    • 2015
  • This study analyzes the characteristics by age and type for middle aged and elderly women foot shapes aged 40-69 years. ANOVA, factor, and cluster analyzed middle aged and elderly women's foot shapes. The results of the study are as follows. First, higher age groups tended to have smaller foot lengths, ball/instep circumferences, circumferences, and ball heights with larger heel height values and higher degrees of gathering of toe 1 and toe 5 toward the feet reference axis. Second, foot lengths were 220 mm-240 mm and the ball circumference's size symbol in high frequency sections were distributed from E to EEEE in the 40s and 60s groups and from D to EEEE in the 50s group. Third, eight factors were extracted through the factor analyses of middle aged and elderly women's foot measurement items. Fourth, a cluster analyses classified the subjects into four types. Type 1 is a normal foot type with medium foot length and small ball circumference and type 2 is a long and flat foot type with a type with large foot length and ball circumference values as well as small ball height values. Type 3 is a thick foot type with a medium foot length, large ball circumference, large ball height and type 4 is a toe deformation foot type with medium foot length, small ball circumference, and a high degree of toe gathering toward the center.

The Kinematic Patterns of Walking according to Obstacle's Height (장애물 높이에 따른 보행의 운동형상학적 변화에 대한 연구)

  • Chung, Hyung-Kuk
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.3
    • /
    • pp.55-63
    • /
    • 2008
  • Background : The Purposes of this study were to understand difference between free walking and obstacle over walking through the naked eye and motion analysis device, and to review merits of obstacle walking training as item of functional assessment in clinical situations. Methods : All participants were male and performed 3 types of walking methods: free walking, obstacle over walking with low block(height=10cm, width=8cm), and obstacle over walking with high block(height=20cm, width=8cm). All walking were performed 3 trials respectively. Results : In the naked eye, initial contact with toes occurred more than heel strike in obstacle over walking, and the flexion angle of hip and knee were increased in obstacle over walking. On interpretations though motion analysis device, cadence, gait speed and weight accept were significant statistically(p<.05). Cadence and gait speed were decreased, and weight accept duration was increased in obstacle over walking. Rotation among three pelvic motions was significant statistically(p<.05), flexion among three hip motions was significant statistically(p<.05) and flexion among three ankle motions was significant statistically(p<.05). Rotation and flexion among three ankle motions was significant statistically(p<.05). Conclusion : Both the naked eye and interpretations of the device presented many difference between free walking and obstacle over walking. In overcrossing obstacles, many participants appeared walking strategy by perform initial contact with toes. Knee flexion was most significant statistically(p<.05) in obstacle over walking with 20cm block.

  • PDF