• 제목/요약/키워드: Heavy-ion beam

검색결과 70건 처리시간 0.026초

Development of Membrane Type Liquid Variable Compensator

  • Takahashi, Seiji;Ochiai, Makoto;Hayakawa, Yoshinori
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.183-185
    • /
    • 2002
  • Heavy ion and proton therapy necessitate range weeks, which are time consuming. Three types of variable compensator, membrane type liquid variable compensator, are proposed by some of the authors to overcome the difficulties, by those arbitrarily thickness distribution of compensator obtained from treatment planning is created at the site of treatment. None of the ideas, however, is yet realized. In this research, we are trying to construct prototype membrane-type liquid variable compensator. This variable compensator partitions air and liquid with elasticity membrane and changes the surface of the elasticity membrane with the thread. The air and oil move through holes to and from the out of beam side of two boxes in which they are contained. The boxes are made of Plexiglas(PMMA), the thread which is made of nylon, the elasticity film which is made from latex for the moment.

  • PDF

전자선 조사를 이용한 아크릴산이 그라프트된 폴리프로필렌의 제조 및 중금속 이온 흡착 특성 (Preparation of Acrylic Acid Grafted Polypropylene by Electron Beam Irradiation and Heavy Metal Ion Adsorption Property)

  • 천자영;전준표
    • Composites Research
    • /
    • 제32권6호
    • /
    • pp.335-341
    • /
    • 2019
  • 본 연구는 전자선 조사를 이용하여 폴리프로필렌(polypropylene, PP) 부직포에 아크릴산(acrylic acid, AAc)을 그라프트 한 후 납 이온에 대한 흡착성능을 평가하였다. 다양한 조건에서 그라프트를 실시하여 조사량 100 kGy, 단량체 농도 60%에서 약 50%의 그라프트율을 갖는 아크릴산이 그라프트 된 폴리프로필렌(PP-g-AAc) 부직포를 제조하였다. 제조된 PP-g-AAc 부직포의 물리/화학적 특성을 SEM, ATRIR, 열분석, 인장강도 등의 분석을 통해 평가하였다. SEM으로 확인한 PP와 PP-g-AAc 부직포의 형태에는 큰 변화가 없었으며, ATR-FTIR 결과로부터 PP 부직포에 AAc가 도입되었다고 판단하였다. PP-g-AAc 부직포는 PP 부직포와 비교하여 인장강도는 증가하고 인장변형률은 감소하였다. 하지만 그 변화의 값이 크지 않아 물리적 특성에 큰 영향력은 없을 것이라 판단된다. 다양한 이온들에 대한 PP-g-AAc 부직포의 흡착특성을 평가한 결과 납에 대해 선택적 흡착 거동을 보였다. 결론적으로, 본 연구에서 제조된 PP-g-AAc는 납 이온 흡착을 위한 흡착제로서 응용이 기대된다.

XAS Studies of Ion Irradaited MgO Thin Films

  • Suk, Jae-Kwon;Gautam, Sanjeev;Song, Jin-Ho;Lee, Jae-Yong;Kim, Jae-Yeoul;Kim, Joon-Kon;Song, Jong-Han;Chae, Keun-Hwa
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.312-312
    • /
    • 2012
  • Magnesium oxide has become focus for research activities due to its use in magnetic tunnel junctions and for understanding of do ferromagnetism. Theoretical investigations on such type of system indicate that the presence of defects greater than a threshold value is responsible for the magnetic behaviour. It has also been shown experimentally that by decreasing the film thickness and size of nanoparticles, enhancement/increase in magnetization can be achieved. Apart from the change in dimension, swift heavy ions (SHI) are well known for creating defects and modifying the properties of the materials. In the present work, we have studied the irradiation induced effects in magnesium oxide thin film deposited on quartz substrate via X-ray absorption spectroscopy (XAS). Magnesium oxide thin films of thickness 50nm were deposited on quartz substrate by using e-beam evaporation method. These films were irradiated by 200 MeV Ag15+ ion beam at fluence of $1{\times}10^{11}$, $5{\times}10^{11}$, $1{\times}10^{12}$, $3{\times}10^{12}$ and $5{\times}10^{12}ions/cm^2$ at Nuclear Science Centre, IUAC, New Delhi (India). The grain size was observed (as studied by AFM) to be decreased from 37 nm (pristine film) to 23 nm ($1{\times}10^{12}ions/cm^2$) and thereafter it increases upto a fluence of $5{\times}10^{12}ions/cm^2$. The electronic structure of the system has been investigated by X-ray absorption spectroscopy (XAS) measurements performed at the high energy spherical grating monochromator 20A1 XAS (HSGM) beamline in the National Synchrotron Radiation Research Center (NSRRC), Taiwan. Oxides of light elements like MgO/ZnO possess many unique physical properties with potentials for novel application in various fields. These irradiated thin films are also studied with different polarization (left and right circularly polarized) of incident x-ray beam at 05B3 EPU- Soft x-ray scattering beamline of NSRRC. The detailed analysis of observed results in the wake of existing theories is discussed.

  • PDF

Growth Retardation and Death of Rice Plants Irradiated with Carbon Ion Beams Is Preceded by Very Early Dose- and Time-dependent Gene Expression Changes

  • Rakwal, Randeep;Kimura, Shinzo;Shibato, Junko;Nojima, Kumie;Kim, Yeon-Ki;Nahm, Baek Hie;Jwa, Nam-Soo;Endo, Satoru;Tanaka, Kenichi;Iwahashi, Hitoshi
    • Molecules and Cells
    • /
    • 제25권2호
    • /
    • pp.272-278
    • /
    • 2008
  • The carbon-ion beam (CIB) generated by the heavy-ion medical accelerator in Chiba (HIMAC) was targeted to 7-day-old rice. Physiological parameters such as growth, and gene expression profiles were examined immediately after CIB irradiation. Dose-dependent growth suppression was seen three days post-irradiation (PI), and all the irradiated plants died by 15 days PI. Microarray (Agilent rice 22K) analysis of the plants immediately after irradiation (iai) revealed effects on gene expression at 270 Gy; 353 genes were up-regulated and 87 down-regulated. Exactly the same set of genes was affected at 90 Gy. Among the highly induced genes were genes involved in information storage and processing, cellular processes and signaling, and metabolism. RT-PCR analysis confirmed the microarray data.

Digital PLL을 이용한 초음파진동 측정용 레이저 도플러 진동계의 개발 (The development of laser doppler vibrometer using DPLL for the detection of ultrasonic vibration)

  • 김호성
    • 한국광학회지
    • /
    • 제11권5호
    • /
    • pp.306-311
    • /
    • 2000
  • 본 논문에서는 초음파영역에서 진동하는 물체의 진동주파수와 크기를 측정할 수 있는 레이저 도플러 진동계(Laser Doppler Vibrometer, 이하 LDV)를 설계, 제작하였다. LDV의 광원으로는 파장이 632.8 nm인 He-Ne 레이저를 사용하였으며 Bragg셀에 의해 주파수가 천이되도록 한 마이켈슨형 간섭게 (Michelson interferometer)로 구성하였다. PIN다이오드의 출력은 중심주파수가 40 MHz인 주파수 변조된 신호이며, 이 신호를 증폭하고 주파수를 2.5MHz로 낮춘 후 디지털로 변환하였다. Digital Phase Locked Loop(이하 DPLL)를 사용하여 진동하는 표면의 속도에 비례하는 전압출력을 얻었으며, 이 신호로부터 진동주파수와 크기를 추출하고 주파수특성을 보상하기 위하여 마이크로프로세서를 사용하였다. 그 결과 300 kHz까지의 진동을 측정할 수 있었으며 300 kHz로 진동하는 경우 측정 가능한 최소진폭은 1 nm이었다. 본 연구에서 개발된 LDV는 대용량 전기기기의 부분방전에 의해 발생되는 초음파진동으로부터 최소형 전기 기기의 미세진동까지 측정하는 비접촉식 진동 측정에 사용할 수 있다고 사료된다.

  • PDF

Line Image Correction of the Positron Camera in the Secondary Beam Course of HIMAC

  • Iseki, Yasushi;Mizuno, Hideyuki;Kanai, Tatsuaki;Kanazawa, Mitsutaka;Kitagawa, Atsushi;Suda, Mitsuru;Tomitani, Takehiro;Urakabe, Eriko
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.195-198
    • /
    • 2002
  • A positron camera, consisting of a pair of Anger-type scintillation detectors, has been developed for verifying the ranges of irradiation beams in heavy-ion radiotherapy. Images obtained by a centroid calculation of photomultiplier outputs exhibit a distortion near the edge of the crystal plane in an Anger-type scintillation detector. The images of a $\^$68/Ge line source were detected and look-up tables were prepared for the position correction parameters. Asymmetry of the position distribution detected by the positron camera was prevented with this correction. As a result, a linear position response and a position resolution of 8.6 mm were obtained over a wide measurement field.

  • PDF

400 MeV/nucleon 12C 이온의 MCNPX 와 핵자료를 이용한 차폐 벤치마킹 계산 (400 MeV/nucleon 12C Ions Shielding Benchmark Calculations using MCNPX with Different Nuclear Data Libraries)

  • 신윤성;김용민;김동현;정남석;이희석
    • 한국방사선학회논문지
    • /
    • 제9권5호
    • /
    • pp.295-300
    • /
    • 2015
  • 현재 우리나라는 포항방사광가속기와 국립암센터의 양성자 치료용 가속기와 경주 양성자 가속기가 운영되고 있고 중이온 가속기, 4세대 방사광가속기 등 대형가속기 시설이 건설 중에 있다. 이들 시설에서 고에너지로 가속된 입사입자는 표적물질과 상호작용 후 2차 중성자를 발생시키고, 이 중성자는 가속기 구조물 및 주변 콘크리트, 토양, 지하수 등을 방사화 시킨다. 따라서 이러한 가속기 시설의 안전적 측면을 고려할 때 방사화를 일으키는 중성자의 차폐가 중요하다. 본 연구는 차폐해석에 사용되는 몬테카를로 코드 중 MCNPX를 이용하여 $^{12}C$ beam빔과 표적물질(Cu)과의 상호작용 후 생성되는 중성자를 계산하고, 그 중성자의 철 차폐체와 콘크리트 차폐체의 두께별 투과 후 스펙트럼을 MCNPX의 JENDL/HE 07과 la150을 이용해 비교하여 계산하였다. 빔의 방향과 차폐체의 종류 및 두께에 따라 그 결과를 실험값과 비교하여 검증함으로써 핵자료의 특성을 확인하였으며 향후 대형가속기시설의 선량평가용 기반기술로 활용하고자 하였다.

방사선 치료에서 3D 프린터로 제작된 금속 필라멘트의 투과율에 관한 유용성 평가 (Evaluation of the Usefulness of the Transmittance of Metal Filaments Fabricated by 3D Printers in Radiation Therapy)

  • 권경태;장희민;윤명성
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.965-973
    • /
    • 2021
  • 방사선 치료는 고에너지 X선을 최소 20 Gy에서 80 Gy까지 다양하게 조사되기 때문에 종양이 위치하는 국소부위에 고선량을 투여하며 일부 정상조직의 여러 부작용이 예상 된다. 현재 임상에서는 정상조직의 차폐를 위한 노력으로 대표적인 재료인 납을 사용하고 있지만 납은 인체에 유해한 중금속으로 분류되고 있으며 다량의 피부접촉은 중독을 유발할 수 있다. 따라서 본 연구는 FDM(Fused Deposition Modeling)방식의 3차원 프린터의 재료 Tungsten, Brass, Copper을 이용하여 납의 한계점을 보완 할 수 있는 측정시트를 제작하고 투과성능을 알아보고자 한다. 3D 프린터를 이용해 Tungsten 혼합 필라멘트 투과측정 시트 크기는 70 × 70 mm, 두께는 1, 2, 4 mm로 제작하였으며 제작한 측정시트의 투과성능을 확인하기 위해 선형가속기 (TrueBeam STx, S/N: 1187)에서 발생된 6, 15 MV을 Water Phantom과 Ion chamber (FC-65G), elcetrometer (PTW UNIDOSE)을 사용하여 SSD 100 cm, 물 속 5 cm에서 100 MU를 조사하여 측정하고 투과성능을 평가하였다. 각 소재의 측정시트를 1 mm씩 증가시킨 결과 6 MV에서는 Tungsten 시트의 경우 3.8~3.9 cm일때의 시트는 기존 납의 차폐체 두께 6.5 cm 보다 얇으며, 15 MV에서는 Tungsten 시트의 경우 4.5~4.6 cm일 때 시트는 기존 납의 차폐체 두께 7 cm 보다 얇으며 동등한 성능을 확인할 수 있었다. 본 연구를 통하여 Tungsten 합금 필라멘트을 이용하여 제작한 투과측정 시트는 고에너지 영역에서의 투과 차폐 가능성을 확인하였으며. 대체품으로써의 사용가능성 또한 우수함을 확인하였다, 향후 3D 프린팅 기술로 차폐제 제작을 위한 기초자료로 제공할 수 있을 것으로 사료 된다.

Study on Concrete Activation Reduction in a PET Cyclotron Vault

  • Bakhtiari, Mahdi;Oranj, Leila Mokhtari;Jung, Nam-Suk;Lee, Arim;Lee, Hee-Seock
    • Journal of Radiation Protection and Research
    • /
    • 제45권3호
    • /
    • pp.130-141
    • /
    • 2020
  • Background: Concrete activation in cyclotron vaults is a major concern associated with their decommissioning because a considerable amount of activated concrete is generated by secondary neutrons during the operation of cyclotrons. Reducing the amount of activated concrete is important because of the high cost associated with radioactive waste management. This study aims to investigate the capability of the neutron absorbing materials to reduce concrete activation. Materials and Methods: The Particle and Heavy Ion Transport code System (PHITS) code was used to simulate a cyclotron target and room. The dimensions of the room were 457 cm (length), 470 cm (width), and 320 cm (height). Gd2O3, B4C, polyethylene (PE), and borated (5 wt% natB) PE with thicknesses of 5, 10, and 15 cm and their different combinations were selected as neutron absorbing materials. They were placed on the concrete walls to determine their effects on thermal neutrons. Thin B4C and Gd2O3 were placed between the concrete wall and additional PE shield separately to decrease the required thickness of the additional shield, and the thermal neutron flux at certain depths inside the concrete was calculated for each condition. Subsequently, the optimum combination was determined with respect to radioactive waste reduction, price, and availability, and the total reduced radioactive concrete waste was estimated. Results and Discussion: In the specific conditions considered in this study, the front wall with respect to the proton beam contained radioactive waste with a depth of up to 64 cm without any additional shield. A single layer of additional shield was inefficient because a thick shield was required. Two-layer combinations comprising 0.1- or 0.4-cm-thick B4C or Gd2O3 behind 10 cm-thick PE were studied to verify whether the appropriate thickness of the additional shield could be maintained. The number of transmitted thermal neutrons reduced to 30% in case of 0.1 cm-thick Gd2O3+10 cm-thick PE or 0.1 cm-thick B4C+10 cm-thick PE. Thus, the thickness of the radioactive waste in the front wall was reduced from 64 to 48 cm. Conclusion: Based on price and availability, the combination of the 10 cm-thick PE+0.1 cmthick B4C was reasonable and could effectively reduce the number of thermal neutrons. The amount of radioactive concrete waste was reduced by factor of two when considering whole concrete walls of the PET cyclotron vault.

양성자 빔 선량 분포 검증을 위한 감마 꼭지점 영상 장치의 양면 실리콘 스트립 검출기 신호처리 모듈 개발 (Development of Signal Processing Modules for Double-sided Silicon Strip Detector of Gamma Vertex Imaging for Proton Beam Dose Verification)

  • 이한림;박종훈;김재현;정원균;김찬형
    • Journal of Radiation Protection and Research
    • /
    • 제39권2호
    • /
    • pp.81-88
    • /
    • 2014
  • 최근, 인체 내 양성자 빔의 선량 분포를 검증하기 위해 새로운 개념의 영상기법인 감마 꼭지점 영상(gamma vertex imaging, GVI)이 제안되었다. GVI는 양성자 빔과 매질과의 핵반응으로 인해 발생하는 즉발감마선의 발생 위치를 결정하기 위해 입사한 감마선을 전자 변환기에서 전자로 변환한 후 전자의 궤적을 추적하는 방법을 사용한다. GVI 영상장치는 감마선을 전자로 변환하기 위한 전자 변환기, 전자 궤적을 추적하기 위한 2대의 양면 실리콘 스트립 검출기(double-sided silicon strip detector, DSSD)와 전자의 에너지 결정을 위한 섬광체 흡수부 검출기로 이루어진다. 본 연구에서는 GVI 영상 장치를 구성하는 DSSD 전용의 신호처리 장치를 구성하는 핵심 장치인 전하 민감형 전치증폭기(charge sensitive preamplifier, CSP) 모듈과 성형 증폭기 모듈을 개발하였으며, 상용 제품과 성능을 비교해 보았다. 감마선원의 에너지 스펙트럼 측정 결과, 자체제작 CSP 모듈이 상용 제품보다 에너지 분해능이 약간 낮은 것을 확인하였으며, 성형 증폭기의 경우 거의 동일한 성능을 보여주는 것을 확인할 수 있었다. 개발된 신호처리 장치의 노이즈의 크기를 나타내는 $V_{rms}$ 값은 6.48 keV으로 평가되었으며, 이는 145 ${\mu}m$의 DSSD에 전달되는 전자의 에너지( > ~51 keV)를 고려할 때 본 장치를 이용하여 전자의 궤적을 충분히 정확하게 결정할 수 있음을 확인할 수 있음을 보여준다.