• Title/Summary/Keyword: Heavy metal measuring

Search Result 54, Processing Time 0.026 seconds

Detection of Heavy Metal Ions by the Cuvette Assay Measuring Urease Inhibitory Activity (Urease 저해활성 측정 cuvette assay에 의한 중금속 이온 검출)

  • Kim, Dong-Kyung;Park, Kyung-Rim;Kang, Eun-Mi;Park, In-Seon;Kim, Nam-Soo
    • Applied Biological Chemistry
    • /
    • v.46 no.2
    • /
    • pp.74-78
    • /
    • 2003
  • To determine the urease inhibitory activity of various heavy metal ions, a photometric cuvette assay for measuring ammonia production was developed. In this assay, the absorbance values at 630 m were linearly increased according to the ammonia concentrations up to 3.0 mg/l (r : 0.998). The urease inhibitions upon addition of a single species of heavy metal ions were in the decreasing order of Hg(II) > Pb(II) > Cu(II) > Cd(II) > Zn(II) ions. As expected, the urease inhibitions at a fixed concentration of a single species and at varying concentrations of other species occurred in the additive way. The above results show the applicability of the current method to the selective detection on Hg(II) ions as well as the screening of heavy metal ions possibly present at various samples.

Determination of measuring time for decision of heavy metal ion concentration in Square Wave Voltammetry with FPGA (FPGA를 이용한 네모파 전압전류법의 계측시간 분석)

  • Lee, Jaechoon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.4
    • /
    • pp.25-31
    • /
    • 2016
  • In this research, to analyze the concentration of heavy metal ions in water, we tried to find the measuring time at which the faradaic electric currents flowing by the pure oxidation-reduction reaction from the pushing up mercury electrode of the stripping scan square wave voltammetry(SV+SWV) methods system becomes larger than the capacitance electric current. In order to do this, a method for analyzing signals using FPGA has been designed and we conducted 120 experiments using it. As a result, when the frequency of the square wave is 40Hz, The valid potential-current signal was measured from 96.6667% to 96.7155% of the end of the pulse of the forward and reverse, and the optimal signal was measured at 96.6667%. In addition, the experiment was carried out 40 times by changing the pulse height of the square wave from 10Mv to 40Mv. As a result, at a size smaller than 40Mv, there is little change in the magnitude of the potential-current, and an invalid signal was generated when it is out of this size.

Evaporation and stabilization of the heavy metals in EAF dust-clay bodies (EAF 더스트-점토계 소지의 중금속 휘발 및 안정화)

  • Kim, J.H.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.15 no.6
    • /
    • pp.217-221
    • /
    • 2005
  • The evaporation amounts of volatile Cd, Pb and Zn were characterized by measuring their total concentrations in the EAF dust-clay bodies with various mixing ratio and heat treatment temperature. TCLP test was conducted for evaluating the chemical stabilities of the heavy metal elements. Evaporation amounts and leaching concentrations of heavy metal components were strongly dependent on the mixing ratio and heat treatment temperature. The evaporation of the heavy metal components in EAF dust was effectively suppressed by increasing the clay content. The leaching concentrations of heavy metal components were decreased with increasing clay content and temperature. 20 wt% EAF dust-80 wt% clay sample shows nearly zero evaporation and leaching concentrations of heavy metal components. XRD analysis showed that peak intensities of major crystalline phases such as franklinite and quartz were decreased with increasing the heat treatment temperature which means that the stabilization mechanism of the heavy metals was related with the vitrification process of the $SiO_2$ in the clay.

Measurement of Liquid-Metal Flow with a Dynamic Neutron Radiography (중성자 래디오그래피를 이용한 액체금속 유동장 측정)

  • Cha, Jae-Eun;Saito, Yasushi
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.4
    • /
    • pp.63-68
    • /
    • 2011
  • The flow-field of a liquid-metal system is very important for the safety analysis and the design of the steam generator of liquid-metal fast breeder reactor. Dynamic neutron radiography (DNR) is suitable for a visualization and measurement of a liquid metal flow and a two-phase flow in a metallic duct. However, the three dimensional DNR techniques is not enough to obtain the velocity information in the wide channel up to now. In this research, a high speed DNR technique was applied to visualize the heavy liquid-metal flow field in the narrow channel with the HANARO-beam facility. The images were taken with a high frame-rate neutron radiography at 250 fps and analyzed with a Particle Image Velocimetry(PIV) method. The images were compared with the results of the commercial CFX code to study the feasibility of DNR technique for the measuring the heavy liquid-metal flow field. The PIV images could discern the turbulent vortex flow in the two-dimensional narrow channel.

Emission Characteristics of Metal Elements from a MSW Incinerator (도시폐기물 소각시설에서의 금속배출특성 연구)

  • Kim, Ki-Heon;Kim, Sam-Cwan;Song, Geum-Ju;Seo, Yong-Chil
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • The behavior and characteristics of heavy metals at different streams in a MSWI(Municipal Solid Waste Incinerator) with a capacity of 100tonnes/day were investigated by measuring the concentration of heavy metals and gases and analyzing their leaching data from ashes. Metal components of Cr, Cu, Cd and Pb were in higher concentrations in the fly ashes collected after the water spray tower than in the bottom ashes. It was due to condensation by a lower temperature with water spray cooling. Metal contents in the bottom ash became higher for finer particles as expected. The mass balance of heavy metals in different stream was estimated from the analyzed data in bottom ash and collected dusts at different locations. For the lower volatility of metals such as Pb, Cu, Cr, 88-97% of them remained in the bottom ash, while Cd and Hg escaped from the combustor with remaining in bottom ash of 18.4 and 0.8%, respectively. In most cases the leaching rate of fly ash showed higher values than that of bottom ash, with the their average acidities of 9.8 and 11.9 respectively.

  • PDF

Evaluation of Nitrogen Mineralization in Soil Polluted by Zinc and Cadmium

  • Walpola, Buddhi Charana;Arunakumara, K.K.I.U.;Yoon, Min-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.4
    • /
    • pp.559-564
    • /
    • 2011
  • Soil microbial functions are considered to be effective in assessing the severity of heavy metal pollution. Therefore, this study was carried out to examine the effect of heavy metals on nitrogen mineralization by measuring the releasing pattern of inorganic nitrogen ($NH_4^+$-N and $NO_3^-$-N) in a soil treated with heavy metals. A factorial combination of two heavy metals (Zn and Cd) treated with three concentrations (50, 100 and $150{\mu}mol\;g^{-1}$ soils) was used in a laboratory incubation. Nitrogen mineralization was determined at 3, 7, 14, 21, 28, 42 and 56 days after the treatments replicated four times. Soil sample free from heavy metals was served as the control. The amount of nitrogen mineralization from heavy metal treated soils was found to be decreased at an increasing rate during the first 21 days of incubation. However, as the incubation progressed, nitrogen mineralization was found to be decreased at decreasing rates. Furthermore, during this period, nitrogen mineralization in Cd treated soils was significantly lower ($P{\leq}0.05$) than that of the control. Soils treated with Cd at the concentration of $150{\mu}mol\;g^{-1}$ showed the lowest N mineralization throughout the incubation. Nitrogen mineralization in Zn treated soils ($50{\mu}mol\;g^{-1}$) was found to be higher than the other heavy metal treated soils. On the base of present findings, nitrogen mineralization of soil could be considered as a viable assessment of the degree of heavy metal pollution.

Determination of Frequency for decision of heavy metal ion concentration in Square Wave Voltammetry with FPGA SoC (FPGA SoC를 이용한 네모파 전압전류법의 주파수 변화에 따른 계측 분석)

  • Lee, Jaechoon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.4
    • /
    • pp.101-107
    • /
    • 2018
  • In the stripping scan square wave voltammetry (SV+SWV) polarography that is often used to analyze the concentration of heavy metals in water, we must measure the point where the faradic current that flows by the pure oxidation-reduction reaction at the electrode is greater than the capacitive current, the frequency cannot be too high. Therefore we wanted to find the frequency range that can be measured. In order to do this, we came up with a method to analyze the signal using FPGA Soc. With this method, the frequency of the square wave was increased from 10Hz to 400Hz by 10Hz, and the measuring time of the square wave was changed from 96.695% to 96.765% by 0.005% while 1600 experiments were conducted. As a result, the frequency of the square wave maintained a stable area of potential-current within 320Hz and it was possible to measure the potential-current signal when calculating the measuring time within the frequency range of 96.7155%.

The SWSV signal analysis for decision of heavy metal ion concentration using digital signal processing method (디지털신호처리기법을 이용한 중금속이온농도 결정의 SWSV 신호분석)

  • Lee, Jae choon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.4
    • /
    • pp.11-17
    • /
    • 2009
  • Polarography is a subclass of voltammetry where the working electrode is a dropping mercury electrode. More, I developed the experiment for raising up mercury electrode. In Voltammetry, information about an analyte is obtained by measuring the current as the potential is varied at oxidation-reduction reaction. A plot of current vs. potential in a polarography experiment shows the current oscillations correspoding to the drops of Hg falling from the capillary. The drops growth causes capacitive and faradic current. These changing current effects combined with experiments where the potential is continuously changed can result in noisy traces. The raising up type improved upon the method of dropping in hardware. In reduction of the noise, moving average smoothing method have been used. But the other procedure is introduced based on Fourier transformation. So FFT and IFFT engine was implemented and installed in my experiment. However, after experimentation, peak height as the measuring parameter gave a good linear relationship to concentration. The resolution of potential peaks of various kinds, using Zn and Cu as the example, was improved using the smoothing method.

Purification process and reduction of heavy metals from industrial wastewater via synthesized nanoparticle for water supply in swimming/water sport

  • Leiming Fu;Junlong Li;Jianming Yang;Yutao Liu;Chunxia He;Yifei Chen
    • Advances in nano research
    • /
    • v.15 no.5
    • /
    • pp.441-449
    • /
    • 2023
  • Heavy metals, widely present in the environment, have become significant pollutants due to their excessive use in industries and technology. Their non-degradable nature poses a persistent environmental problem, leading to potential acute or chronic poisoning from prolonged exposure. Recent research has focused on separating heavy metals, particularly from industrial and mining sources. Industries such as metal plating, mining operations, tanning, wood and chipboard production, industrial paint and textile manufacturing, as well as oil refining, are major contributors of heavy metals in water sources. Therefore, removing heavy metals from water is crucial, especially for safe water supply in swimming and water sports. Iron oxide nanoparticles have proven to be highly effective adsorbents for water contaminants, and efforts have been made to enhance their efficiency and absorption capabilities through surface modifications. Nanoparticles synthesized using plant extracts can effectively bind with heavy metal ions by modifying the nanoparticle surface with plant components, thereby increasing the efficiency of heavy metal removal. This study focuses on removing lead from industrial wastewater using environmentally friendly, cost-effective iron nanoparticles synthesized with Genovese basil extract. The synthesis of nanoparticles is confirmed through analysis using Transmission Electron Microscope (TEM) and X-ray diffraction, validating their spherical shape and nanometer-scale dimensions. The method used in this study has a low detection limit of 0.031 ppm for measuring lead concentration, making it suitable for ensuring water safety in swimming and water sports.

Leaching and stabilization of the heavy metals with pH in EAF dust-clay system (EAF 더스트-점토계의 중금속 용출 및 안정화에 미치는 pH의 영향)

  • Lee, Jee-Young;Lee, Ki-Gang;Kim, Yoo-Taek;Kang, Seung-Gu;Kim, Jung-Hwan
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.2
    • /
    • pp.88-93
    • /
    • 2006
  • To recycle the electric arc furnace (EAF) dust as a ceramic raw materials, the leaching concentrations of heavy metals (Zn, Pb, Cr, Cd) were analysed with various pH and mixing ratios for EAF dust and EAF dust-clay mixtures. The evaporation amounts of the some heavy metals were evaluated by measuring their total concentrations in the sintered bodies of EAF dust-clay mixtures with various mixing ratio and sintering temperature. Toxicity characteristic leaching procedure (TCLP) test was conducted for evaluating the chemical stabilities of the heavy metal elements. Leaching concentrations of heavy metal ions shows minimum leaching concentration at the pH 10. Evaporation amount of heavy metals in the sintered bodies were evaluated for the mixtures of pH 10 depenidng on mixing ratio and sintering temperature. Evaporation of heavy metal components were increased with increasing the sintering temperature and contents of the EAF dust. The evaporation of the heavy metal components in EAF dust was effectively suppressed by increasing the clay content. The leaching concentrations of heavy metal components were decreased with increasing clay content and temperature.