• 제목/요약/키워드: Heavy fuel Oil

검색결과 170건 처리시간 0.029초

오토필터의 감속기 일체형 모터에 관한 유연 다물체 동역학 해석 (Flexible Multi-body Dynamic Analysis for Reducer-integrated Motor of Autofilter)

  • 김진광;김복덕;이계승
    • 열처리공학회지
    • /
    • 제36권5호
    • /
    • pp.311-317
    • /
    • 2023
  • An autofilter is a device that removes impurities contained in heavy fuel oil used in diesel engines of ships or power plants, and also automatically removes impurities accumulated in the filter through a reverse washing function. The reducer-integrated motor serves to rotate the filter at low speed to enable reverse automatic cleaning in the autofilter device. To achieve a low speed of 0.65 to 0.75 rpm in a reducer-integrated motor, a small motor that can operate at 97rpm at a rated voltage of 110 V and 112.5 rpm at 220 V is required. Additionally, a large gear ratio of 1/150 is required. To ensure the durability and reliability of these reducers, the strength of the gear must be evaluated at the design stage. In general, there is a limit to evaluating the stress and strain state according to the vibration characteristics acting on each gear in the driving state of the reducer through quasi-static analysis. Therefore, in this study, the operation characteristics of the auto filter's reducer-integrated motor were first analyzed using the rigid body dynamics analysis method. Then, this rigid body dynamics analysis model was extended to a flexible multibody dynamics analysis model to analyze the stress and strain states acting on each gear and evaluate the design feasibility of the gear.

농촌형 녹색마을에 신재생에너지 보급을 위한 시설재배 및 농업기계의 CO2 배출량 분석 (CO2 Emission Analysis from Horticultural Facilities & Agricultural Machinery for Spread of New and Renewable Energy in Rural-type Green Village)

  • 김종구;유영선;강연구;김영화;장재경;김현태;서광욱;이승기;조희제;강지원
    • 유기물자원화
    • /
    • 제19권1호
    • /
    • pp.86-92
    • /
    • 2011
  • 화석에너지 의존도를 줄이면서 $CO_2$ 배출량을 낮추기 위하여 정부에서는 녹색마을을 선정하고 에너지 자급률을 40% 수준으로 높이려는 계획을 추진 중이다. 본 연구는 각 농업 분야 중에서 농기계의 사용과 재배 시설에 있어서의 에너지 사용량을 파악하고 이를 바이오디젤로 대체하였을 때의 $CO_2$ 저감수준을 분석하고자 하였다. 이를 위하여, 농업 각 분야별 에너지 소비수준의 분석, 그리고 실천 가능한 신재생 에너지원의 선정이 요구된다. 경종재배의 전체 연간온실가스 배출량은 $5,667,258\;t-CO_2$이고, 그 중 시설 부문은 $4,932,607\;t-CO_2$인 것으로 분석되었으며, 농업시설 부문 중 에너지원별로 보면 경유가 $3,105,707\;t-CO_2$, 중유가 $1,370,578\;t-CO_2$를 배출하는 것으로 분석되었다. 우리나라 시설작물의 단위 면적당 온실가스 평균배출량은 $29,418\;t-CO_2/ha$인 것으로 나타났다. 농기계별 2007년 총에너지소비량을 살펴보면 트랙터가 284,763 kL로 가장 높게 나타났으며, 동력 경운기 221,314 kL, 곡물건조기 145,524 kL, 콤바인 72,537 kL 등의 순이었다. 전라북도 G시를 대상으로 이용 중인 시설재배와 농업기계의 이산화탄소 배출량을 비교분석한 결과, 바이오디젤로 전환하면 약 7% 정도의 $CO_2$ 감소효과가 있는 것으로 분석되었다.

열순환식 저온열탈착 정화장치의 개발 및 유류오염 토양 현장 적용 (Development of Low Temperature Thermal Desorption System and Remediation of Soil Contaminated with Petroleum Hydrocarbon)

  • 김국진;이선화;박광진;김치경;이철효;김도선;조석희;장윤영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제13권4호
    • /
    • pp.62-68
    • /
    • 2008
  • 본 연구에서는 토양 이송 장치, 로터리킬른, RTO, 사이클론 및 백필터 등으로 구성되어 있고 이동이 가능한 저온열탈착 장치를 제작하여 현장유류오염토양의 처리시험을 수행하였다. 제작된 열탈착장치는 LPG를 연료로 사용하고 배출되는 가스를 RTO를 통하여 재순환하는 방식을 적용하여 경제적인 운전이 가능하도록 하였다. 장치의 현장시험을 위하여 경유와 $C_30$ 이상의 heavy oil로 혼합 오염된 현장토양(2,690 mg TPH/kg soil) 을 먼저 선별기를 통해 50 mm 이하의 입경을 가진 토양으로 채 분리한 후, LTTD 장치의 로터리킬른에 체류시간 15분 조건에서 시간당 7$m^3$의 양으로 투입하였다. 열탈착장치의 온도를 각각 평균 $567^{\circ}C$$692^{\circ}C$로 조정한 후 오염토양의 정화 운전을 수행한 결과, 배출되는 정화토양의 TPH 농도는 각각 46 mg/kg과 32 mg/kg로서 각각 평균 98.3과 98.9%의 높은 정화 효율을 얻을 수 있었다.

석탄가스화 기술의 최신 개발 동향 및 상업화 현황 (The Newest Technology Development and Commercialization Status of Coal Gasification)

  • 이진욱;윤용승;강원석
    • 에너지공학
    • /
    • 제24권3호
    • /
    • pp.150-163
    • /
    • 2015
  • 가스화 기술은 석탄, 중질잔사유, 펫코크, 등의 저급 화석연료를 고효율 및 고청정으로 활용할 수 있는 대표적인 차세대 화석연료 활용기술로서 관련 시장은 지속적으로 그리고 급속도로 팽창하고 있다. 수년전만 하더라도 기존 미분탄 활용 기술에 비하여 대용량화 및 이용률 등의 한계가 지적되어 왔으나 최근에는 이러한 한계들이 대부분 극복되고 있으며, 미래에는 가스터빈 또는 산소제조를 위한 이온전달 멤브레인 등의 관련 기술의 지속적인 발전으로 인하여 보다 경쟁력이 있는 기술이 될 것으로 예상된다. 초기에는 미국과 유럽에서 기술 개발 및 시장을 주도하여 왔으며 최근에는 중국이 매우 빠른 속도로 대용량화 기술 개발을 완료하여 자국에서 시장 확대 및 외국으로의 진출을 노리고 있다. 특히 석탄가스화 기술은 이산화탄소 포집 기술을 포함할 경우 매우 매력적인 기술이며, 우리나라와 같이 천연가스 가격이 비싼 나라에서는 석탄가스화에 의한 천연가스 생산 플랜트가 지금도 충분한 경제성을 가진다는 점 등을 고려하면 석탄가스화 기술은 지속적으로 관심을 가져야 하는 기술이다. 이에 본고에서는 가스화 기술에 관한 세계 최대의 컨퍼런스인 2014 가스화 기술 컨퍼런스에서의 자료와 최신 자료들을 활용하여 주요 기술 보유 업체들의 최근의 기술개발 및 상업화 동향을 살펴보았다.

산업용 보일러의 질소산화물 제어를 위한 SNCR 적용 연구 (Study of SNCR Application to Industrial Boiler for NOx Control)

  • 신미수;김혜숙;장동순
    • 대한환경공학회지
    • /
    • 제27권3호
    • /
    • pp.286-292
    • /
    • 2005
  • 본 연구는 향후 산업적으로 질소산화물 규제가 중요한 문제로 대두될 만한 산업용 보일러를 대상으로 수행하였다. 일반적으로 SNCR 방법의 산업용 보일러로의 적용은 혼합을 위한 충분한 체류시간을 제공하지 못한다는 점에서 적합하지 않은 것으로 알려져 있다. 본 연구의 목적은 SNCR 장치의 산업용 보일러 적용가능성을 조사하기 위한 것이다. 구체적으로 연료로 중유를 사용하는 시간당 스팀 발생량 40톤 규모의 산업용 보일러를 연구 대상으로 하였다. 사업용 보일러의 수치 해석을 위한 3-D 직교좌표계 프로그램에는 난류 유동, 난류 연소반응, NOx의 생성과 환원제와의 반응을 통한 소멸반응 등을 포함하고 있다. 또한 개발된 코드에는 Lagrangian 방법에 의한 입자궤적 프로그램이 포함되어 있고, 주입구에서 접선방향으로의 선회효과를 계산에 의해 고려하였다. 선회버너 효과를 고려한 결과 단화염이 생성되었으며 NOx 환원반응에 적합한 온도 영역의 증가로 인해 NOx 제거효율도 향상되었다. 실험결과와의 비교를 통하여 프로그램을 검증하였으며, 계산결과 혼합용 공기 주입을 통한 환원제와의 혼합 향상을 통해서 SNCR 방법의 산업용 보일러 적용가능성을 확인하였다.

Air Pollution Trends in Japan between 1970 and 2012 and Impact of Urban Air Pollution Countermeasures

  • Wakamatsu, Shinji;Morikawa, Tazuko;Ito, Akiyoshi
    • Asian Journal of Atmospheric Environment
    • /
    • 제7권4호
    • /
    • pp.177-190
    • /
    • 2013
  • Air pollution trends in Japan between 1970 and 2012 were analyzed, and the impact of air pollution countermeasures was evaluated. Concentrations of CO decreased from 1970 to 2012, and in 2012, the Japanese environmental quality standard (EQS) for CO was satisfied. Concentrations of $SO_2$ dropped markedly in the 1970s, owing to use of desulfurization technologies and low-sulfur heavy oil. Major reductions in the sulfur content of diesel fuel in the 1990s resulted in further decreases of $SO_2$ levels. In 2012, the EQS for $SO_2$ was satisfied at most air quality monitoring stations. Concentrations of $NO_2$ decreased from 1970 to 1985, but increased from 1985 to 1995. After 1995, $NO_2$ concentrations decreased, especially after 2006. In 2012, the EQS for $NO_2$ was satisfied at most air quality monitoring stations, except those alongside roads. The annual mean for the daily maximum concentrations of photochemical oxidants (OX) increased from 1980 to 2010, but after 2006, the $98^{th}$ percentile values of the OX concentrations decreased. In 2012, the EQS for OX was not satisfied at most air quality monitoring stations. Non-methane hydrocarbon (NMHC) concentrations generally decreased from 1976 to 2012. In 2011, NMHC concentrations near roads and in the general environment were nearly the same. The concentration of suspended particulate matter (SPM) generally decreased. In 2011, the EQS for SPM was satisfied at 69.2% of ambient air monitoring stations, and 72.9% of roadside air-monitoring stations. Impacts from mineral dust from continental Asia were especially pronounced in the western part of Japan in spring, and year-round variation was large. The concentration of $PM_{2.5}$ generally decreased, but the EQS for $PM_{2.5}$ is still not satisfied. The air pollution trends were closely synchronized with promulgation of regulations designed to limit pollutant emissions. Trans-boundary OX and $PM_{2.5}$ has become a big issue which contains global warming chemical species such as ozone and black carbon (so called SLCP: Short Lived Climate Pollutants). Cobeneficial reduction approach for these pollutants will be important to improve both in regional and global atmospheric environmental conditions.

습식전기집진기를 활용한 입자상 물질 및 황산화물 저감 성능에 관한 실험적 연구 (Experimental Study on Reduction of Particulate Matter and Sulfur Dioxide Using Wet Electrostatic Precipitator)

  • 김종립;오원철;이원주;최재혁
    • 해양환경안전학회지
    • /
    • 제27권6호
    • /
    • pp.898-904
    • /
    • 2021
  • 본 연구에서는 강화되는 황산화물 및 입자상물질의 배출규제를 만족시키기 위한 후처리장치로 습식전기집진기에 대한 실험적 연구를 수행하였다. 실험을 위해 선박용 중유(HFO, 황함유량 약 2.1%)를 연료로 사용하는 선박용 4행정 디젤엔진(STX-MAN B&W)을 활용하였으며, 연돌에 설치된 습식전기집진기 입/출구에서 측정을 실시하였다. 미세먼지 측정을 위해서는 광학식 계측기(OPA-102) 및 중량농도측정방식(Method 5 Isokinetic Train)을 이용하였으며, 황산화물 계측을 위해서는 FT-IR(DX-4000)을 사용하였다. 엔진부하는 50%, 75%, 100%로 변화시키면서 실험을 실시하였다. 실험 결과로, 엔진부하가 50%에서 100%로 변화함에 따라 미세먼지 저감 효율은 모든 부하 조건에서 94~98% 정도의 높은 저감 효율을 나타내었다. 추가적으로 습식전기집진기 퀜칭존에서 배기가스의 온도를 낮추는 과정 중 세정액에 의한 이산화황(SO2) 저감을 확인할 수 있었으며, 저감율은 엔진부하에 따라 55%~81%로 확인되었다.

실내외 $NO_2$농도 및 $NO_2$개인폭로량과 이들에 영향을 미치는 요인에 관한 연구 -도시지역 주택 및 주부를 대상으로- (A Study on the Indoor-Outdoor $NO_2$ Levels and Personal Exposures to $NO_2$ with Analysis of factors Affecting the $NO_2$ Concentrations - Centering on Urban Homes and Housewives -)

  • 전진호;이채언;김준연;정요한
    • Journal of Preventive Medicine and Public Health
    • /
    • 제21권1호
    • /
    • pp.132-151
    • /
    • 1988
  • This study was conducted to establish the control program for preventing unfavorable health effects of nitrogen dioxide($NO_2$) exposure in homes by preparing the fundamental data for evaluation of relation-ships between $NO_2$ levels and influencing factors through measurements of indoor-outdoor $NO_2$ levels and personal $NO_2$ exposures for housewives with questionnaire survey on 172 homes in Pusan area from April to June, 1987 $NO_2$ measurements were made by using diffusion tube samplers(Palmes tube $NO_2$ sampler) for one week at 4 sites in homes ; kitchen(KIT), bedroom(BED), living room(LIV), outdoor(OUT) and near the collar of housewives(personal exposure livel, PNO). The details of questionnaire were number of household members(FAM), number of regular smokers (SMOKER), daily number of meals eaten(MEAL), type of housing units(HOUSE), location of house with distance from the heavy traffic roads as walking time(DIST), and of kitchen(KAREA), kind of cooking fuels(FUEL), cooking time of each meal(CTIME), usage of kitchen fan for cooking(FAN), type of heating facilities(HEAT) and so on of subject homes. The Obtained results were as fellows : 1) The mean $NO_2$ level was significantly higher at indoors than outdoors(p<0.01) and the kitchen $NO_2$ level was the highest with $33.7{\pm}13.6ppb$(9.5-81.5ppb). The mean personal exposure level of $NO_2$ for housewives was $20.6{\pm}8.8ppb$(3.1-46.9ppb). 2) The mean indoor $NO_2$ level was significantly higher in the group of household members above 5 than below 4(p<0.05), in detached dwellings than apartments(p<0.001), within 5 minutes of distance than over 5 minutes(p<0.001), in the group of unusing fan(p<0.001), in the group of longer cooking time(p<0.001), and it was in order of coal briquette, gas, electricity and oil by kind of cooking fuels(p<0.05). 3) Variables showing significant correlation(p<0.001) with indoor $NO_2$ level were kitchen $NO_2$ level(r=0.8677), cooking time(r=0.5921), outdoor $NO_2$ level(r=0.5192), personal $NO_2$ exposure level(r=0.4615), usage of kitchen fan(r=0.3573) and location of house(r=-0.2988) 4) As a result of multiple regression analysis, the most significant influencing variable to the kitchen $NO_2$ level was cooking time[KIT=$-0.378{\pm}11.772$(CTIME)+0.298(OUT)+3.102(FAN)], it was kitchen $NO_2$ level to the indoor $NO_2$ level[IND=6.996+0.458(KIT)+0.230(OUT)-1.127(KAREA)], and it was indoor $NO_2$ level to the personal $NO_2$ exposure level[PNO=15.562+0.729(IND)-4.542(DIST)-0.200(KIT)] 5) It was recognized that aritificial ventilation in the kitchen, suppression of unnecessary combustion and replacement of cooking fuel, as much as possible, were effective means for decreasing indoor $NO_2$ levels in homes.

  • PDF

선체 부식 및 손상 부재를 고려한 침몰선박의 구조 안전성 평가에 관한 연구 - 제7 해성호를 중심으로 - (Structural Safety Assessment of a Sunken Ship Considering Hull Corrosion and Damaged Members - Focus on the Sunken Ship 'No. 7 HaeSung' -)

  • 이승현;김원돈;서재준
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제19권4호
    • /
    • pp.332-340
    • /
    • 2016
  • 침몰선박은 선체 내에 적재되어 있는 잔존연료 및 유해 화물 등의 유출로 인하여 주변 환경과 선박의 안전 항해에 피해 요인으로 작용할 수 있다. 대부분의 침몰선박은 해저에 침수된 상태로 비교적 안정적인 상태로 놓여있지만 선체 자중, 화물창의 잔존화물에 의한 하중과 해저면과의 접촉상태, 조류 및 해류 등의 영향으로 침몰선박 잔존연료 유출에 영향을 줄 수 있다. 침몰선박은 침몰 이후 부식이 진행되어 선체 구조부재의 두께가 지속적으로 감소하고 있는 상황이다. 따라서 침몰선박의 붕괴 가능성에 대한 구조안전성 평가가 필요하며 그 결과는 침몰선박의 위해도 평가요소 중 '유출가능성' 평가 항목에 반영되어야 한다. 본 연구에서는 침몰선박의 구조 안전성 평가 방법에 대한 단계별 절차를 제시하고, 집중관리대상 침몰선박으로 분류된 '제7해성호'를 대상으로 선체구조의 붕괴 가능성을 추정하기 위한 구조 안전성 평가 방안을 제시한다. 침몰 당시 선체 손상 상태와 침몰 이후 선체구조 부재의 부식량 추정을 바탕으로 대상 침몰선박의 선체구조 붕괴 가능성을 산정한 결과, 현 상태에서는 전체적인 선체구조 붕괴가 일어날 가능성이 낮은 편으로 추정되지만, 향후 시간에 따른 부식량 증가로 인한 선체구조 붕괴가 일어날 가능성은 다소 높은 것으로 판단된다. 따라서 부식 및 해양환경 변화가 침몰선체 구조 안전성에 미치는 영향 등의 연구는 지속적으로 수행 되어져야 할 것으로 사료된다.

온수배관에 의한 온실 내부의 온도변화 (Variation of Indoor Air Temperature by using Hot Water Piping in Greenhouse)

  • 윤용철;신익수;배승범;김현태;최진식;서원명
    • 농업생명과학연구
    • /
    • 제46권2호
    • /
    • pp.179-190
    • /
    • 2012
  • 본 연구는 유가상승에 따른 온실의 경영비 절감과 적설지역의 적설재해를 경감시키기 위하여 온수배관을 이용한 난방효과 및 온실곡부의 온도 상승효과를 구명하고자 수행되었다. 전체적으로 실험구의 온도가 대비구 보다 약 $2.0{\sim}6.0^{\circ}C$정도 높게 나타났다. 천창부직포를 개방한 경우, 최저온도가 약 $3.0{\sim}12.0^{\circ}C$범위로 나타나 적극적인 난방을 하게 되면 적설피해도 어느 정도 예방할 수 있을 것으로 판단되었다. 온실 내부의 높이별 온도 차이는 미미한 것으로 나타났다. 재배작물에 따른 온실의 최대난방부하는 각각 약 $37,000kcal{\cdot}h^{-1}$$41,700kcal{\cdot}h^{-1}$정도이었다. 실험기간동안 최저 외기온 $-11.9{\sim}4.0^{\circ}C$ 범위에서 설정온도별 발열량은 95,000~322,000 kcal 정도로서 시간당 $6,050{\sim}20,900kcal{\cdot}h^{-1}$정도의 범위에 있었고, 최대난방부하와 비교하면 약 15~56%정도의 난방에너지를 공급할 수 있을 것으로 나타났다. 그리고 실험기간동안 전체 발열량과 소비전력량은 각각 2,629,025 kcal 및 677.3 kWh이었다. 화석연료인 경유로 난방 할 경우, 실험기간동안 소요되는 소비량은 291L 정도이었고, 비용은 331,700 won인 것으로 나타났다. 전력사용에 대한 총비용은 24,400 won정도로서 경유 소비 비용의 7.5%정도로 나타났다. 또한 전체 소비전력량을 에너지로 환산하면 약 582,200 kcal이고, 이 에너지는 전체 발열량의 약 22%에 불과하였다.