• 제목/요약/키워드: Heavy floor impact sound

검색결과 123건 처리시간 0.026초

공동주택의 중량충격음 저감을 위한 제진재의 활용 (Use of Damping Materials for Reducing Heavyweight Floor Impact Noise in Apartment Buildings)

  • 정영;유승엽;김민배;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.96-99
    • /
    • 2005
  • Noise and vibration generated by heavy-weight floor impact in apartment buildings were studied. The resonance frequency increased in the floor structures where damping materials were used in the living room and the bedroom. Both the acceleration wavelength and the acceleration level decreased. The results showed that the resonance frequency increased and vibration acceleration level decreased when the damping materials were used. Heavy-weight impact sound levels of the structure decreased substantially below 80Hz.

  • PDF

실충격음과 표준충격원으로 발생된 바닥충격음의 비교 (Selection of the standard impact sounds similar to the human impact sounds in reinforced concrete floors)

  • 사토신이치;이평직;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1167-1172
    • /
    • 2007
  • This study investigates human floor impact sounds; not only the children's jumping and running represented by heavy-weight impact source such as bang machine and impact ball but also the high-heel walking and the light weight object dropping represented by tapping machine in the standard measurements. However, due to reliability problems as a standard impactor, bang machine has not been included in the new draft of ISO 10140 Part 3: Measurement of impact sound insulation. Therefore, the procedure to convert the floor impact sound level of the bang machine into that of the impact ball has been demanded because the bang machine has been only the standard heavy-weight standard impact source and much of its data has been collected, This study indicates that the use of impact ball is reliable and that the bang machine data can be successfully converted into the impact ball data in case of box-frame type reinforced concrete structures.

  • PDF

임팩트 볼에 의한 바닥충격음 측정 및 평가 간편법 (Simplified method on measurement and evaluation of floor impact sound using impact ball)

  • 김용희;이신영;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.631-635
    • /
    • 2006
  • In this study, simplified methods on measurement and evaluation of heavy-wight impact sound was proposed due to provide easy quality control method to construction engineers. The simplified methods include using of rubber impact ball instead of bang machine, reduced number of measuring and impact positions which is prescribed as over 4 points, using of hand-held sound level meter as a frequency analyser and prediction equation for $L_{i.Fmax.AW}$, single number rating, using $L_{Amax}$, and $L_{Lmax}$ at each frequency band. The results showed that a method of boundary driving and boundary measuring is the most similar to the current rating method.

  • PDF

기존 건축물 층간소음 저감공법 적용 효과 분석 (A Effects of applying the noise reduction method between existing buildings)

  • 송태협;전찬수;김지훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.249-250
    • /
    • 2018
  • To control the floor noise generated in the apartment building, a method of reinforcing the floor at the floor is applied. However, since existing buildings are difficult to reinforce upper generations, the ceilings of lower generations should be reinforced. The purpose of this study is to analyze the reduction effect by measuring the impact noise after reinforcing the floor soundproofing material on the ceiling of the existing building. In order to ensure the economical efficiency and flame retardancy of the products used as building interior materials, the existing polyurethane foam was impregnated with mineral to prepare test specimens and attached to the concrete slab surface. As a result, it was shown that heavy impact sound can reduce 2dB~5dB and light impact sound can reduce 4~8dB.

  • PDF

바닥충격음 완충재의 동적특성과 소음저감 성능 비교 (Comparison Between the Dynamic Properties and Noise Isolation Performances for a Floor Impact Isolation Pad)

  • 양수영;이동훈;홍병국;송화영;이주원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.275-278
    • /
    • 2005
  • In this study, the dynamic properties of a floor impact sound isolation pad expressed in terms of the natural frequency, the dynamic stiffness per unit area and the loss factor are measured by the resonant method. By using the measured dynamic properties, the vibration transmissibility diagram is obtained for each isolation pad, which is compared with the values tested by the impact sound sources at the room in an apartment. From the comparative results, it is found that the noise reduction Performances. of isolation pads are closely connected with the natural frequency and the dynamic stiffness per unit area.

  • PDF

뜬바닥구조의 균열강도 평가 (Evaluation of Cracking Strength of Floating Floor System)

  • 이정윤;이범식;전명훈;김종문
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.53-61
    • /
    • 2015
  • 이 연구에서는 층간소음을 억제하기 위하여 사용되는 뜬바닥구조의 구조거동을 실험을 통하여 평가하였다. 최근 층간소음을 억제하기 위하여 연질의 완충재가 사용되며, 이로 인하여 마감모르타르나 기포콘크리트에 균열이 발생할 가능성이 높아지고 있다. 이 연구에서는 완충재의 강성, 하중가력 위치, 바닥 구성층을 변수로 하는 16개의 2방향 뜬바닥구조를 실험하였다. 실험에 의하면 완충재의 강성은 뜬바닥구조의 균열강도에 큰 영향을 미치며 완충재의 할선계수가 0.2MPa인 경우에 낮은 강도에서 균열이 발생하였다. 또한 슬래브의 단부나 모서리에 하중이 가력될 경우에 균열강도가 감소하였다. 뜬바닥구조를 이루고 있는 마감모르타르는 균열강도에 영향을 주었지만 기포콘크리트는 균열강도에 영향을 주지 않았다.

바닥충격음의 평가등급 설정에 관한 연구 (A Study on the Rate Classification of Floor Impact Noise)

  • 류종관;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.486-491
    • /
    • 2002
  • Auditory experiments based on subjective responses were undertaken for the standard heavy and light weight impact noise. Relations between noise levels and subjective evaluations were also investigated. As a result, it was shown that the noise class was rated with the range of sensible satisfaction by investigating the various social responses for the floor impact noise. The rate classification for the heavy weight impact noise is suggested as a design guide for concrete slabs which satisfy the residents' requirements in various sound insulation capacities of multistory residential buildings.

  • PDF

능동소음제어 기술을 이용한 층간소음 저감효과 분석 (Analysis of Reduction Effect of Inter-Floor Noise Using Active Noise Control (ANC) Technique)

  • 김호진;김중관;김준환;김현석;위혁
    • 한국방재안전학회논문집
    • /
    • 제16권3호
    • /
    • pp.45-56
    • /
    • 2023
  • 본 연구에서는 능동소음제어(ANC) 기술을 층간소음 분야에 적용하기 위하여 40~500 Hz 대역의 중량충격음을 제어하기 위한 ANC 시스템을 구성하였다. ANC 시스템에는 Fx-LMS 알고리즘 기반의 적응형 필터를 활용한 피드포워드 방식의 제어기술을 도입하였다. ANC 시스템 설정을 위해 가상 시뮬레이션을 통해 ANC를 구성하는 변수 연구를 실시하였고, 이를 통해 최적 필터와 시스템 배치 방법을 정립하였다. 또한 본 연구에는 개발된 ANC 시스템을 한국건설생활시험연구원(KCL)의 층간소음 시험실에 설치한 후 표준시험방법에 따라 ANC 시스템 구동 전후 4 dB의 층간소음 저감효과를 확인하였다. 시험결과를 통해 본 연구에서 개발한 ANC 시스템이 중량충격음에 대한 등급 기준을 한 단계를 상향시킬 수 있는 수준의 효과가 있음을 확인하였다.

음향모드를 고려한 공동주택 중량충격음 소음해석 (Numerical Analysis of Heavy-weight Impact Noise for Apartment Units Considering Acoustic Mode)

  • 문대호;박홍근;황재승;홍건호;임주혁
    • 한국소음진동공학회논문집
    • /
    • 제22권7호
    • /
    • pp.676-684
    • /
    • 2012
  • Numerical analysis was performed to investigate the heavy-weight impact noise of apartment houses. The FEM is practical method for prediction of low-frequency indoor noise. The results of numerical analysis, the shape of the acoustic modes in room-2 are similar to that of acoustic pressure field at the fundamental frequency of acoustic modes. And the acoustic pressure was amplified at the natural frequency of the acoustic modes and structural modes. The numerical analysis result of sound pressure level at 63 Hz and 125 Hz octave-band center frequency are similar to the test results, but at 250 Hz and 500 Hz have some errors. Considering most of bang-machine force spectrum exists below 100 Hz, the noise at 250 Hz and 500 Hz are not important for heavy-weight impact noise. Thus, the FEM numerical analysis method for heavy-weight impact noise can apply to estimate heavy-weight impact noise for various building systems.