• 제목/요약/키워드: Heating tank

검색결과 206건 처리시간 0.029초

온실 난방을 위한 모세관형 태양열 집열기의 성능에 미치는 유량의 효과에 관한 연구 (The Effects of Water Flow Rates on the Performance of a Capillary Tube Solar Collector for Greenhouse Heating)

  • 유영선;장유섭;홍성기;윤진하;정두호;강영덕
    • 생물환경조절학회지
    • /
    • 제5권1호
    • /
    • pp.57-64
    • /
    • 1996
  • To use effectively the solar energy in greenhouse heating, a high performance solar collector should be developed. And then the size of the solar collector and thermal storage tank should be determined through the calculation of heating load. The solar collector must be set in the optimum tilt angle and direction to take daily solar radiation maximally, and the flow rate of heat transfer fluid through the solar collector should be kept in the optimum range. In this research, the performance tests of a capillary tube solar collector were performed to determine the optimum water flow rate and the results summarized as follows. 1. The regressive equations for efficiency estimations of the capillary tube solar collector in the open loop were modeled in the water flow rate of 700-l,000 $\ell$/hr. 2. The optimum water flow rate of the solar collector was estimated by the second order polynomial regression and the maximum efficiency was 80% at the water flow rate of 850 $\ell$/hr. 3. The solar thermal storage system consisted of a capillary tube solar collector and a water storage tank was tested at the water flow rate of 850 $\ell$/hr in the closed loop, and obtained the solar thermal storage efficiency of 55.2%. 4. As the capillary tube solar collector engaged in this experiment was made of non-corrosive polyolefin tubes, its weight was as light as 1/30 of the flat plate solar collector made of copper tubes. Therefore it was considered to be suitable for the greenhouse heating system.

  • PDF

예인수조시험의 계측정도 향상에 관한 연구 (I) (수조수온, 기포와 난류촉진장치에 대하여) (A Study on the Improvement of Measuring Accuracy of the Experiments in Towing Tank (I) (Water Temperature, Air Bubbles and Turbulence Stimulator))

  • 박용제
    • 대한조선학회논문집
    • /
    • 제34권2호
    • /
    • pp.1-10
    • /
    • 1997
  • 예인수조에서 저항추진 성능을 추정하기 위한 선형시험을 수행한 때는 계측정도에 나쁜 영향을 주는 불안정현상에 유의하여야 한다. 불안정현상을 일으키는 큰 원인인 수조수 수심에 따른 수온의 불균일, 연중 수온의 변화, 난류촉진장치, 저항시험 사의 이복현상에 대해 검토하였다. 그리고 수조수 순환, 수조동 난방, 탈기장지 및 난류촉진장치의 개선 등을 그 해결 방안으로 제시하였다.

  • PDF

온실 태양잉여열을 이용한 히트펌프시스템의 난방 성능평가에 관한 실증 연구 (Empirical evaluation of the heating performance by a heat pump system with surplus heat from a greenhouse)

  • 전병용;박윤철;고광수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권1호
    • /
    • pp.99-104
    • /
    • 2017
  • 본 연구는 태양일사에 의하여 가열되는 온실상단에 고온의 태양잉여열을 축열조에 축열한 후 이를 이용하여 온실을 난방하는 히트펌프시스템의 실증연구에 관한 것으로 히트펌프시스템은 축열조를 구비하고, 각종 열교환을 위한 판형열교환기, 팬코일유닛 그리고 부가적인 에너지원으로 태양일사를 직접 집열할 수 있는 태양집열기로 구성되어 있다. 히트펌프시스템은 R410a냉매를 사용하며 일반적인 히트펌프시스템과 마찬가지로 외기열원만으로도 운전될 수 있으며, 온실내부의 설정온도에 따른 제어로직에 따라 외부조작없이 온실상단열의 축열운전, 외기공기에 의한 외기열원 및 축열조의 온수를 히트펌프의 작동 없이 난방하는 다수의 운전방식이 자동적으로 운전되도록 하였다. 개발된 축열식 히트펌프의 현장평가 성능실험을 위하여 제주시 조천리에 있는 $100m^2$ 크기의 온실에 설치하고 10월부터 12월까지 운전하였다. 실증연구 실험을 수행한 결과로써 외기열원을 이용하여 난방 할 경우 난방열량은 19.9 kW의 용량을 얻을 수 있었으며, 온실상단의 잉여열에 의하여 축열조의 온수로 히트펌프운전 없이 직접 난방 할 경우에 난방열량은 21.4 kW로 외기난방과 비슷한 난방용량을 나타내는 것을 알 수 있었다.

제주지역 지하공기를 이용한 농업시설용 히트펌프시스템의 난방 성능 분석 - 제주지역을 중심으로 - (The Analysis of heating performance of heat pump system for agricultural facility using underground air in Jeju area - Focused on the Jeju Area -)

  • 강연구;임태섭
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.109-114
    • /
    • 2016
  • Purpose: The underground air is the warm air discharged from the porous volcano bedrock 30-50m underground in Jeju, including excessive humidity. The temperature of the underground air is $15-20^{\circ}C$ throughout the year. In Jeju, the underground air was used for heating greenhouses by supplying into greenhouses directly. This heating method by supplying the underground air into greenhouses directly had several problems. The study was conducted to develop the heat pump system using underground air as heat source for resolving excessive humidity problem of the underground air, adopting the underground air as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) and saving heating cost for agricultural facilities. Method: 35kW scale(10 RT) heat pump system using underground air installed in a greenhouse of area $330m^2$ in Jeju-Special Self-Governing Province Agricultural Research & Extension Services, Seogwipo-si, Jeju. The inlet and outlet water temperature of the condenser, the evaporator and the thermal storage tank and the underground air temperature and the air temperature in the greenhouse were measured by T type thermocouples. The data were collected and saved in a data logger(MV200, Yokogawa, Japan). Flow rates of water flowing in the condenser, the evaporator and the thermal storage tank were measured by an ultrasonic flow meter(PT868, Panametrics, Norway). The total electric power that consumed by the system was measured by a wattmeter(CW240, Yokogawa, Japan). Heating COP, rejection heat of condenser, extraction heat of evaporator and heating cost were analyzed. Result: The underground air in Jeju was adopted as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) in 2010. From 2011, the heat pump systems using underground air as a heat source were installed in 12 farms(16.3ha) in Jeju.

온수 급탕 및 난방을 위한 히트 펌프 태양열 시스템의 성능 분석 (Performance Analysis of Solar Thermal System with Heat Pump for Domestic Hot Water and Space Heating)

  • 손진국
    • 한국태양에너지학회 논문집
    • /
    • 제38권5호
    • /
    • pp.49-62
    • /
    • 2018
  • This study aims to analyze the performance of solar thermal system with heat pump for domestic hot water and heat supply. There are four types of system. Systems are categorized based on the existence of a heat pump and the ways of controlling the working fluid circulating from the collector. Working fluid is controlled by either temperature level (categorized as system 1 and 2) or sequential flow (system 3 and 4). Heat balance of the system, the solar fraction, hot water and heating supply rates, and performance of heat pump are analyzed using TRNSYS and TESS component programs. Technical specifications of the main facilities are as follow; the area of the collector to $25m^2$, the volumes of the main tank and the buffer tank to $0.5m^3$ and $0.8m^3$, respectively. Heating capacity of the heat pump in the heating mode is set to 30,000 kJ / hr. Hot water supply set 65 liters per person each day, total heat transfer coefficient of the building to 1,500 kJ / kg.K. Indoor temperature is kept steadily around $22^{\circ}C$. The results are as follows; 6 months average solar fraction of system 1 turns out to be 39%, which is 6.7% higher than system 2 without the heat pump, indicating a 25% increase of solar fraction compared to that of system 2. In addition, the solar fraction of system 1 is 2% higher than that of system 3. Hot water and heating supply rate of system 1 are 93% and 35%, respectively. Considering the heat balance of the system, higher heat efficiency, and solar fraction, as whole, it can be concluded that system 1 is the most suitable system for hot water and heat supply.

온수 보일러용 열구동 펌프에 관한 연구 (A Study on the Thermal Pump of the Hot Water Boiler)

  • 염한길;김욱중;김창주
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.15-23
    • /
    • 2000
  • In this study, develop the thermal pump using water evaporation and condensation. Vapor from heating room moves up to pumping room and press the water of pumping room. Consequently water is pumped out to water tank. Then hot vapor direct contact with cold water in condensing room after pumping process. At this time, pressure of condensing room is down to-5kPa and suck in water of tank. This pump executes self ping and good durability because of no mechanical moving parts. Thermal pump is pumped cyclic so that, this pump is not used single. Therefore thermal pump of hot water boiler used to multi-stage for stable pumping rate. As the result of performance test, the developed thermal pump proves pumping action of water evaporation/condensation. And total volume flow rate is 500liter during one hour. If three thermal pump is installed parallel, this pump can use to the hot water boiler in the 300,000kcal/h class.

  • PDF

심야전력을 이용한 Cascade Heat Pump Cycle의 운전결과 분석 (Analysis on Cascade Cycle Heat Pump Application as Night Storage Heater)

  • 정훈;황성욱;이철희
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.113-118
    • /
    • 2011
  • To analyze and verify the effect of replacing thermal storage heater by a cascade cycle heat pump using midnight electricity was installed and tested at a customer's house in Wonju, Korea. The electric night storage heater is consist of 30kW electric heater and 2,700 liters of thermal storage water tank to supply hot water for warming house floor. The power for electric heater was cut off and hot water was only generated by cascade cycle heat pump. Current thermal storage water tank was not eliminated and electric heater wiring was modified. Some operation logic of the heat pump was also modified for proper operation. The required capacity of the heat pump and hot water temperature for given warming condition were estimated. The estimated capacity of heat pump was about 19kW and estimated hot water temperature for proper heating was at least $75^{\circ}C$.

6kW급 태양열 온수급탕 시스템의 실증실험 및 분석(제3보 최적설계 및 경제성평가) (Verification Experiment and Analysis for 6kW Solar Water Heating System(Part 3 : Optimum Design and Economic Evaluation))

  • 최봉수;이봉진;강채동;홍희기
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.16-24
    • /
    • 2005
  • The goal of the present paper is to show the optimum design and operation conditions on 6 kW solar water heating system by using computer simulation with verified modelling. As the object functions, we took not only the amount of acquired and auxiliary heat but LCC, which has a relative importance and decisive role in economy. As expected, the maximum heat is acquired at the slope of collector with the equal degree to the latitude, facing the south. The capacity increase of the circulation pump and the storage tank lead to the increase of acquired heat and the decrease of auxiliary heat, but do not necessarily give economical advantages owing to additional electrical power consumption. In the present system, the minimum LCC can be obtained at the storage tank volume of 450 L and the mass flow rate of 0.344 kg/s.

공동주택 적용 지열 및 우수열원을 이용한 히트펌프의 실험적 연구 (A Experimental Study on the Ground Source and Rain Water Heat Source Heat Pump System in Apartment)

  • 고건혁;김지영;강은철;이의준;현명택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.833-837
    • /
    • 2008
  • GSHP(Ground Source Heat Pump) has been extensively disseminated due to the recent increasing demand over new and renewable energy. In this study, the operating performance of rain water and ground source heat pump system (RW-GSHP) was compared with GSHP during the heating test. Leaving load temperature(LLT) was $50^{\circ}C$, $53^{\circ}C$, $56^{\circ}C$, respectively and rain water tank temperature(RWT) was $13^{\circ}C$, $15^{\circ}C$, $17^{\circ}C$ in this heating test. The experiment was focused on comparison of the system operating performance depending on leaving load temperature (LLT) and rain water tank temperature (RWT). The results showed that rain water and ground source heat pump system (RW-GSHP) was higher heating performance and COPh than those of GSHP.

  • PDF

태양열 온실 난방에 대한 최척 집열 면적과 경제성 평가 (Optimum Collector Area and Economic Evaluation for the Greenhouse Heating)

  • 박이동;김규인
    • 태양에너지
    • /
    • 제2권1호
    • /
    • pp.49-58
    • /
    • 1982
  • Aim of this study was to obtain the heating performance and the economic evaluation on solar heating system for greenhouse which area of floor was $90m^2$. For heating performance effective solar energy for the greenhouse was compared with overall heating loads including coefficient of heat transfer and conduction. And the economic evaluation solar heating system was evaluated by comparison its initial investiment costing with oil saving cost. Initial investiment costing included collector cost, storage cost, piping cost, control system cost and miscellaneous costs which included pumps, motors etc. The contents of this study included the survey of climate conditions for solar heating, long-term collector performance and optimum collector area of solar heating system in existing greenhouse. The results are follows: 1. Average horizontal radiation during winter was $2,434Kcal/m^2$ day which was the highest value in this country, so the climate conditions of Suwon was suitable for solar heating. 2. Resulting calculation of the optimum collector area was $30m^2$ and the solar energy accounted for 30% of the overall heating load. 3. The capacity of storage tank required 60 liter per unit area ($m^2$) of solar collector.

  • PDF