• Title/Summary/Keyword: Heating source

Search Result 897, Processing Time 0.025 seconds

Effect of Operating Parameters on the Physical Properties of Activated Carbon Manufactured with Bead-Type Polymer Resin (구형 고분자수지로 활성탄제조 시 운전인자의 영향)

  • Lee, Gangchoon;Yoon, Taekyung;Shon, Zangho
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.279-286
    • /
    • 2013
  • Using a cation exchange resin of polystyrene-DVB copolymer as a carbon source for the production of activated carbon, the effects of operating parameters on the physical properties of activated carbon such as specific surface area and specific pore volume were experimentally studied. In carbonization process specific surface area and specific pore volume of carbonized product decreased with the increase of carbonization temperature and time. They were proportional to activation temperature and time up to the specific temperature and time in activation process. In carbonization process the increase of heating rate gave negative effect to the properties. The properties of activated product, on the contrary, increased with the heating rate in carbonization process. The properties of activated carbon manufactured with the resin exchanged with divalent cations were lower than those with raw resin.

Analysis on The Production Costs and Energy Balance of Heating Wood-Chip by Yarding Machines (집재기계에 따른 난방용 목재칩의 생산비용 및 에너지 수지분석)

  • Hwang, Jin-Sung;Oh, Jae-Heun;Kim, Joon-Soon;Cha, Du-Song
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.6
    • /
    • pp.799-805
    • /
    • 2009
  • To construct the production system of forest biomass as a small scale heating energy source, energy availability of wood-chip was examined by cost and energy balance analysis in the production process. The costs to produce wood-chip of 1 kg was calculated by yarding machines and their operational gradient conditions. As a result, 195.45~210.54 won/kg were required as production costs of wood-chip. Input energy rate (%) which is output to input energy in wood-chip production process were showed as 26.58~27.38%. Energy input rate by operational gradient was not significantly difference, and scenario B with tower yarder system appeared by more efficient than scenario A with tractor yarding system in opposition to production costs analysis.

Potential Performance Enhancement of Dual Heat Pump Systems through Series Operation (히트펌프 직렬운전에 의한 성능 향상 가능성에 관한 연구)

  • Baik, Young-Jin;Kim, Min-Sung;Chang, Ki-Chang;Lee, Young-Soo;Kim, Hyeon-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.797-802
    • /
    • 2012
  • In this study, the potential performance enhancement in a dual heat pump system through series operation was investigated by a comparison between the performance for parallel and series operation for a heating supply temperature of $60^{\circ}C$. To compare the performance of each configuration fairly, the heat transfer surface area of the heat exchangers was fixed. The inlet temperatures and the flow rates of the heat source and the load were also fixed. In addition, the heat transfer and pressure drop characteristics of the working fluids were considered to achieve a more realistic comparison. The results show that the heating coefficient of performance (COP) of the series configuration is approximately 5% higher than that of the parallel configuration under the simulation conditions considered in the present study.

Performance Investigation of Solar-Heating Ocean Thermal Energy Conversion (SH-OTEC) in Korea (태양열 이용 해양온도차발전시스템의 성능 예측)

  • Nguyen, Van Hap;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.43-49
    • /
    • 2013
  • The use of ocean thermal energy conversion (OTEC) to generate electricity is one of the methods proposed to utilize renewable energy and to protect the environment. In this study, simulations were performed to investigate the effect of weather conditions in the Ulsan region, Korea, on the efficiency of a solar-heating OTEC (SH-OTEC) system. This system utilizes solar thermal energy as the secondary heat source. Various working fluids were also simulated to select one that is suitable for this system. The results showed that R152A, R600, and R600A, in that order, were the most suitable working fluids. The effective area of the solar collector for a $20^{\circ}C$ increase in the collector outlet temperature fluctuated from 50 to $97m^2$ owing to the change in the monthly average solar gain. The annual average efficiency of the SH-OTEC increases to 6.23%, compared to that of a typical conventional OTEC, which is 2-4%.

Effects of Pipe Network Composition and Length on Power Plant Waste Heat Utilization System Performance for Large-scale Horticulture Facilities (발전소 온배수를 적용한 대규모 시설원예단지용 난방시스템의 열원이송 배관 재질 및 거리에 따른 성능평가)

  • Lee, Keum ho;Lee, Jae Ho;Lee, Kwang Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.4
    • /
    • pp.14-21
    • /
    • 2015
  • Korean government plans to establish large-scale horticulture facility complexes using reclaimed land in order to improve the national competitiveness of agriculture at the government level. One of the most significant problems arising from the establishment of those large-scale horticulture facilities is that these facilities still largely depend on a fossil fuel and they require 24 h a day heating during the winter season in order to provide the necessary breeding conditions for greenhouse crops. These facilities show large energy consumption due to the use of coverings with large heat transmission coefficients such as vinyl and glass during heating in the winter season. This study investigated the applicability of waste heat from power plant for large-scale horticulture facilities by evaluating the waste heat water temperature, heat loss and energy saving performance as a function of distance between power plant and greenhouse. As a result, utilizing power plant waste heat can reduce the energy consumption by around 85% compared to the conventional gas boiler, regardless of the distance between power plant and greenhouse.

A STUDY OF LYNDS 1299 DARK CLOUD

  • RYU OK-KYUNGI;LEE YOUNGUNG
    • Journal of The Korean Astronomical Society
    • /
    • v.31 no.2
    • /
    • pp.161-171
    • /
    • 1998
  • We have mapped about 1.5 square degree regions of Lynds 1299, a well isolated dark cloud in the Outer Galaxy (l = $122^{\circ}$, b = $-7^{\circ}$), in the J = 1- 0 transition of $^{12}CO$ and $^{13}CO$ with the 13.7 m radio telescope at Taeduk Radio Astronomy Observatory (TRAO). We found that there are two velocity components in the molecular emission, at $V_{LSR} = -52 km S^{-1}$ (Cloud A) and -8.8 km $s^{-1}$ (Cloud B), respectively. We have derived physical parameters of two molecular clouds and discussed three different mass estimate techniques. We found that there are large discrepancies between the virial and LTE mass estimates for both clouds. The large virial mass estimate reflects the fact that both are not gravitationally bound. We adopt the mass of $5.6 {\times}10^3 \;M{\bigodot}$ for Cloud A and $1.2{\times}10^3 \;M{\bigodot}$) for Cloud B using conversion factor. Cloud A is found to be associated with a localized star forming site, and its morphology is well matching with that of far-infrared (FIR) dust emission. It shows a clear ring structure with an obvious velocity gradient. We suggest that it may be a remnant cloud from a past episode of massive star formation. Cloud B is found to be unrelated to Cloud A (d = 800 pc) and has no specific velocity structure. The average dust color temperature of the uncontaminated portion of Cloud A is estimated to be 24$\~$27.4 K. The low dust temperature may imply that there is no additional internal heating source within the cloud. The heating of the cloud is probably dominated by the interstellar radiation field except the region directly associated with the new-born B5 star. Overall, the dust properties of Cloud A are similar to those of normal dark cloud even though it does have star forming activity.

  • PDF

A study on growing of bulk AlN single crystals grown having a (011) growth face of by PVT method (PVT법을 이용한 (011)면으로 성장된 AlN 단결정 성장에 관한 연구)

  • Kang, Seung-Min
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.1
    • /
    • pp.32-34
    • /
    • 2015
  • AlN Single Crystal were grown by PVT (Physical vapor transport) method on bulk seed. It was performed by high-frequency induction-heating coil. AlN source powder was loaded at bottom side of the carbon crucible and the crystal seed was loaded at the upper side of the crucible. The temperature conditions of the growth was varied $2000{\sim}2100^{\circ}C$ and the surrounding pressure was $1{\times}10^{-1}{\sim}200$ Torr. And the hot-zone of the heating position was controlled elaborately according to growth. The 17 mm-diameter, 7 mm-thickness AlN single crystal is obtained for about 600 hours growing. It was recognized that the growth direction of as grown crystal was R[011] by the Laue X-Ray camera measurement.

The Experimental Research for the Use Characteristics of the Passive and Active type Domestic Solar Hot Water Systems (자연형 및 설비형 태양열 온수기의 이용특성에 대한 실험적 연구)

  • Lee, Dong-Won;Kwak, Hee-You
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.82-88
    • /
    • 2013
  • There are the stirring test and drain test in the daily performance test to determine the thermal performance of a domestic solar hot water system. The drain test is a test that measures the discharge heating rate while drain the hot water from the top of the storage tank and supply the city water to the bottom of the tank. From the perspective of the user, this drain test is more effective than the stirring test. In this study, the thermal performance were compared through the drain test for a passive type and an active type domestic solar hot water systems consisting of the same storage tank and collectors. At this point, a passive type was used the horizontal storage tanks, and an active type was used vertical storage tank. In the drain test, when the hot water drained up to the reference hot water temperature, an active type which have vertical storage tank represents excellent daily performance than a passive type which have horizontal storage tank regardless of weather conditions. The reason for this is because the vertical storage tank is advantageous to thermal stratification in the tank. After the drain test, the residual heat for the horizontal storage tank was much more than the vertical storage tank, but in the next day the amount of discharged heat were less than the those of vertical storage tank neither. Thus, the solar water heating system which have horizontal storage tank should be adopted preheating control method rather than separate using control method when connected with auxiliary heat source device.

Preparation and Characterization of Zn2SiO4:Mn2+ Green Phosphor with Solid State Reaction (고상법에 의한 Zn2SiO4:Mn2+녹색 형광체의 제조와 특성에 관한 연구)

  • Yoo, Hyeon-Hee;Nersisyan, Hayk;Won, Hyung-Il;Won, Chang-Whan
    • Korean Journal of Materials Research
    • /
    • v.21 no.6
    • /
    • pp.352-356
    • /
    • 2011
  • [ $Zn_{2(1-x)}Mn_xSiO_4$ ]$0.07{\leq}x{\leq}0.15$) green phosphor was prepared by solid state reaction. The first heating was at $900^{\circ}C-1250^{\circ}C$ in air for 3 hours and the second heating was at $900^{\circ}C$ in $N_2/H_2$(95%/5%) for 2 hours. The size effect of $SiO_2$ in forming $Zn_2SiO_4$ was investigated. The temperature for obtaining single phase $Zn_2SiO_4$ was lowered from $1100^{\circ}C$ to $1000^{\circ}C$ by decreasing the $SiO_2$ particle size from micro size to submicro size. The effect of the activators for the Photoluminescence (PL) intensity of $Zn_2SiO_4:Mn^{2+}$ was also investigated. The PL intensity properties of the phosphors were investigated under vacuum ultraviolet excitation (147 nm). The emission spectrum peak was between 520 nm and 530 nm, which was involved in green emission area. $MnCl_2{\cdot}4H_2O$, the activator source, was more effective in providing high emission intensity than $MnCO_3$. The optimum conditions for the best optical properties of $Zn_2SiO_4:Mn^{2+}$ were at x = 0.11 and $1100^{\circ}C$. In these conditions, the phosphor particle shape was well dispersed spherical and its size was 200 nm.

Methane-Steam Reforming Simulation for a High Temperature Solar Chemical Reactor (고온 태양열 화학 반응기에서의 메탄-수증기 개질반응 시뮬레이션)

  • Ko, Jo-Han;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.44-49
    • /
    • 2009
  • Steam reforming of methane in the high temperature solar chemical reactor bas advantage in its heating method. Using concentrated solar energy as a heating source of the reforming reaction can reduce the $CO_2$ emission by 20% compared to hydrocarbon fuel. In this paper, the simulation result of methane-steam reforming on a high temperature solar chemical reactor(SCR) using Fluent 6.3.26 is presented. The high temperature SCR is designed for the Inha Dish-1, a Dish type solar concentrator installed in Songdo city. Basic SCR performance factors are referred to the former researches of the same laboratory. Inside the SCR porous metal is used for a receiver/reactor. The porous metal is carved like a dome shape on the incident side to increase the heat transfer. Also, ring-disc set of baffle is inserted in the porous metal region to increase the path length. Numerical and physical models are also used from the former researches. Methane and steam is mixed with the same mole fraction and injected into the SCR. The simulation is performed for a various inlet mass flow rate of the methane-steam mixture gas. The result shows that the average reactor temperature and the conversion rate change appreciably by the inlet mass flow rate of 0.0005 kg/s.