• Title/Summary/Keyword: Heating source

Search Result 897, Processing Time 0.03 seconds

2D Kinetic Simulation of Partially Magnetized Capacitively Coupled Plasma Sources (2차원 동역학 시뮬레이션을 활용한 부분적으로 자화된 용량성 결합 플라즈마 전산 모사)

  • Sung Hyun Son;Junbeom Park;Kyoung-Jae Chung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.118-123
    • /
    • 2023
  • Partially magnetized capacitively coupled plasma (CCP) sources are investigated using a two-dimensional kinetic simulation code named EDIPIC-2D. A converging numerical solution was obtained for CCP with a 60 MHz power source, while properly capturing the dynamics of electrons and power absorption over a single RF period. The effects of magnetic fields with different orientations were evaluated. Axial magnetic fields caused changes in the spatial distribution of plasma density, affecting the loss channel. Transverse magnetic fields enhanced stochastic heating near the powered electrode, leading to an increase in plasma density while the significant E×B drift loss compensated for this rise.

  • PDF

Development of a diagnostic coronagraph on the ISS: BITSE overview and progress report

  • Kim, Yeon-Han;Choi, Seonghwan;Bong, Su-Chan;Cho, Kyungsuk;Park, Young-Deuk;Newmark, Jeffrey;Gopalswamy, Nat.;Yashiro, Seiji;Reginald, Nelson
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.56.4-56.4
    • /
    • 2019
  • The Korea Astronomy and Space Science Institute (KASI) has been collaborating with the NASA's Goddard Space Flight Center, to install a coronagraph on the International Space Station (ISS). The coronagraph will utilize spectral information to simultaneously measure electron density, temperature, and velocity. As a first step, we developed a new coronagraph and launched it on a stratospheric balloon in 2019 (BITSE) from Fort Sumner, New Mexico in USA. As the next step, the coronagraph will be be further developed, installed and operate on the ISS (CODEX) in 2022 to address a number of important questions (e.g., source and acceleration of solar wind, and coronal heating) in the physics of the solar corona and the heliosphere. Recently, BITSE has been launched at Fort Sumner, New Mexico. In this presentation, we will introduce the BITSE mission and discuss recent progress.

  • PDF

Measuring sub-mm emission from local AGN host galaxies by JCMT SCUBA-2

  • Kim, Changseok;Woo, Jong-Hak;Chung, Aeree;Baek, Junhyun;Jadhav, Yashashree
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.54.1-54.1
    • /
    • 2021
  • Observing sub-mm continuum emission from cold dust can play an important role in measuring star formation rates of galaxies, especially in the case of AGN host ones, since AGNs contaminate FIR fluxes by dust heating. To measure star formation rates, we observed total 49 local AGN host galaxies(z<0.2) by SCUBA-2 camera at James Clerk Maxwell Telescope(JCMT) at 450㎛ and 850㎛. We performed several tests with the observed images to determine whether each source is detected, and adopted 3s as the flux upper limit in non-detection cases. Using these measurements and FIR archival data, we modeled spectral energy distributions of the galaxies to estimate star formation rates. The effect of AGN activity on host galaxy star formation will be discussed.

  • PDF

Biogas Reforming through Microwave Receptor Heating (마이크로웨이브 수용체 가열을 통한 바이오가스 개질)

  • Young Nam Chun;June An
    • New & Renewable Energy
    • /
    • v.20 no.1
    • /
    • pp.126-134
    • /
    • 2024
  • Biogas, composed mainly of methane (CH4) and carbon dioxide (CO2), is a renewable gas that can serve as an alternative energy source. In this study, we developed a new microwave reformer and analyzed its reforming characteristics. We observed that higher temperatures of the microwave receptor led to increased reforming efficiency. By supplying appropriate amounts of methane and steam, we could prevent carbon generated from the thermal decomposition reaction of carbon dioxide from depositing on the catalytic active layer, thus avoiding the inhibition of catalytic activity. Hydrogen generation was enhanced when maintaining the biogas ratio and steam supply at adequate levels. Increasing the SiC ratio in the receptor improved the uniformity of temperature distribution and growth rate, resulting in higher conversion rates of the reforming process.

Evaluation on Heating Effects of Geothermal Heat Pump System in Farrowing House (지열 난방시스템을 이용한 분만돈사의 난방효과 분석)

  • Choi, H.C.;Park, Jae-Hong;Song, J.I.;Na, J.C.;Kim, M.J.;Bang, H.T.;Kang, H.G.;Park, S.B.;Chae, H.S.;Suh, O.S.;Yoo, Y.S.;Kim, T.W.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.205-215
    • /
    • 2010
  • Geothermal heat pump system (GHPS) is an energy-efficient technology that use the relatively constant and renewable energy stored in the earth to provide heating and cooling. With the aim of using GHPS as a heating source, it's possibilities of application in farrowing house were examined by measuring environmental assessment and sow's performance. A total of 96 sows were assigned to 2 pig housings (GHPS and conventional housing) with 48 for four weeks in winter season. During the experimental period, indoor maximum temperature in GHPS-housing was measured up to $26.7^{\circ}C$, average temperature could maintain $21.2^{\circ}C$. The mean value of dust levels and $CO_2$, $NH_3$ and $H_2S$ gas emissions were decreased in GHPS-housing compare with those of conventional housing. Litter size, birth weight, parity and weaning weight did not differ between housings. However, feed intake of sow in GHPS-housing was lower than that of conventional housing. In energy consumption for heating, electric power consumption increased in GHPS-housing than the conventional housing, a 2,250 kwh increase, whereas there is no fuel usage for heater in GHPS-housing. Amount of ground water circulated for heating in cold weather for earth heat exchanger was 8.4-12.9 ton per day. In conclusion, GHPS may have environmental benefits and effectiveness of heating in farrowing housing and affect the performance in sows.

Modeling of Hydrocarbon Generation and Expulsion in the Tyee Basin, Oregon Coast Range, USA (미국 북서부 오레곤주 타이분지 내 탄화수소 생성과 배출에 대한 모델링 연구)

  • Jang, Hee-Jeong;Ryu, In-Chang
    • Economic and Environmental Geology
    • /
    • v.42 no.1
    • /
    • pp.55-72
    • /
    • 2009
  • The timing of hydrocarbon generation and expulsion from source rocks can be evaluated by reconstructing the geohistory of the basin using petroleum system modeling. The Tyee basin is generally considered having a high hydrocarbon generation potential For the southern part of the basin, the basin evolution from a structural and stratigraphic points of view, the thermal history, and the burial history were reconstructed and simulated using numerical tools of basin modeling. An evaluation of organic geochemistry for the potential source rocks and the possible petroleum systems were analysed to improve the understanding of the hydrocarbon charge of the basin. Organic geochemical data indicate that the undifferentiated Umpqua Group, mudstones of the Klamath Mountains, and coals and carbonaceous mudstones in the Remote Member and the Coquille River Member are the most potential gas-prone source rocks in the basin. The relatively high maturity of the southern Tyee basin is related to deep burial resulting from loading by the Coos bay strata. And the heating by intrusion from the western Cascade arc also affects to the high maturity of the basin. The maturation of source rocks, the hydrocarbon generation and expulsion were evaluated by means of basin modeling. The modeling results reveal that the hydrocarbon was generated in all potential source rocks and an expulsion only occurred from the Remote Member.

The Performance Improvement of a Gas Injection Heat Pump with a Flash Tank (기액분리기를 적용한 가스 인젝션 히트펌프의 성능 향상에 관한 실험적 연구)

  • Son, Kilsoo;Kim, Dongwoo;Choi, Sungkyung;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.297-305
    • /
    • 2017
  • Air-source heat pumps are widely used in residential heating systems. However, the decrease in the capacity of the heat pump is unavoidable when operating at very low and high ambient temperatures. The vapor injection technique is considered a promising technology to overcome this problem. Recent research on vapor injection cycles have mainly adopted a scroll compressor with an internal heat exchanger at severe operating conditions. This study measured the COP and EER of a gas injection heat pump using a flash tank with an inverter-driven rotary compressor at severe operating conditions. Compared to non-injection heat pumps, the heating capacity and COP of the gas injection heat pump improved up to 15% and 2.9%, respectively, at outdoor temperatures of $-10^{\circ}C$ to $7^{\circ}C$. The cooling capacity of the gas injection heat pump was 11% higher than the non-injection heat pump at an outdoor temperature of $35^{\circ}C$. At the same time, the EER of the gas injection heat pump was similar to that of the non-injection heat pump.

Synthesizing and Assessing Fire-Resistant Geopolymer from Rejected Fly Ash

  • An, Eung-Mo;Cho, Young-Hoon;Chon, Chul-Min;Lee, Dong-Gyu;Lee, Sujeong
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.4
    • /
    • pp.253-263
    • /
    • 2015
  • Ordinary Portland cement is a widely favored construction material because of its good strength and durability and its reasonable price; however, spalling behaviour during fire exposure can be a serious risk that can lead to strength degradation or collapse of a building. Geopolymers, which can be synthesized by mixing aluminosilicate source materials such as metakaolin and fly ash, and alkali activators, are resistant to fire. Because the chemical composition of geopolymers controls the properties of the geopolyers, geopolymers with various Si:Al ratios were synthesized and evaluated as fire resistant construction materials. Rejected fly ash generated from a power plant was quantitatively analyzed and mixed with alkali activators to produce geopolymers having Si:Al ratios of 1.5, 2.0, and 3.5. Compressive strength of the geopolymers was measured at 28 days before and after heating at $900^{\circ}C$. Geopolymers having an Si:Al ratio of 1.5 presented the best fire resistance, with a 44% increase of strength from 29 MPa to 41 MPa after heating. This material also showed the least expansion-shrinkage characteristics. Geopolymer mortar developed no spalling and presented more than a 2 h fire resistance rating at $1,050^{\circ}C$ during the fire testing, with a cold side temperature of $74^{\circ}C$. Geopolymers have high potential as a fire resistant construction material in terms of their increased strength after exposure to fire.

Effect of Several Cereal Extracts on Enzymatic Browning (수종 곡류추출물의 효소적갈변 억제효과)

  • 이귀주;안선정
    • Korean journal of food and cookery science
    • /
    • v.13 no.4
    • /
    • pp.390-395
    • /
    • 1997
  • The inhibitory effects of cereal extracts and concentrates from barley, waxy rice flours and malt on enzymatic browning were measured using apple polyphenol oxidase (PPO). Malt concentrate showed the largest inhibitory effect on PPO among all. The relationship between the properties of malt concentrate such as browning intensity and reducing power and their inhibitory effect on PPO was also studied. As the heating time increased, the browning intensity and the reducing power of malt concentrates were increased, while PPO activities were decreased. Inhibitory effect of malt concentrates on PPO increased with heating time and their concentration. L-value and compression force of the apple slices dipped in malt concentrate decreased by 6.9% and 14.3%, respectively, showing the smallest changes compared with raw and water-dipped apple slices during cold storage for 9 days. These results suggest that malt concentrate can be a potential source for the control of enzymatic browning.

  • PDF

A Study on the BEMS Installation and performance Evaluation Method for Energy Monitoring(Measuring) of New Building (신축건물 에너지효율관리를 위한 환경 및 에너지모니터링(계측) 방법론)

  • Kwon, Won Jung;Yoon, Ji Hye;Kwon, Dong Myung
    • Journal of Energy Engineering
    • /
    • v.27 no.2
    • /
    • pp.32-48
    • /
    • 2018
  • Monitoring of energy use should be a priority in order to efficiently manage building energy use. Energy use in buildings can be managed by dividing them into energy sources, uses, and ZONE. By energy source, electricity, gas, fuel, and district heating are supplied to run the building's facilities. The purpose can be divided into five main applications, including cooling, heating, lighting, hot water and ventilation, but not many elevators and electric heaters that are difficult to include in the five applications are classified. ZONE Star refers to the comparison or separate management of areas for which the purpose of the building is similar or different. In addition, energy efficiency management requires control of the temperature, humidity, and people who will be measuring energy in the building, and the recent problem of fine dust should directly affect the ventilation of the building.