• 제목/요약/키워드: Heating ratio

검색결과 951건 처리시간 0.036초

반응표면분석법에 의한 맥문동 열수추출 조건의 최적화 (Optimization for Hot water Extraction Condition of Liriope spicata Tuber Using Response Surface Methodology)

  • 김순동;구연수;이인자;박인경;윤광섭
    • 한국식품저장유통학회지
    • /
    • 제8권2호
    • /
    • pp.157-163
    • /
    • 2001
  • Optimal conditions for hot water extraction of Liriope spicata tuber were investigated with changes in solvent ratio(2∼6 fold) and heating time(1∼5 hr) by response surface methodology. The content of extractable solids increased with an increased in solvent ratio, and the highest content showed at heating time of 3 hr. The content of total steroid saponin increased with a decrease in solvent ratio, and increased with an increase in heating time at increasing the solvent ratio. The content of non-reducing sugar containing oligosaccharides at a lower solvent ratio didn’t show changes depending on heating time, while that at a higher ration decreased with an increase in heating time. Optimal extraction conditions using hot water as the limited conditions of 15∼18% extractable solids, 1.5∼2.0% total steroid saponin, 6∼8% reducing sugar, 6∼7% non-reducing sugar and 13∼15 brix were 3 hrs of heating time and 4 fold of solvent ratio.

  • PDF

시설원예의 지열냉·난방시스템 경제성 분석 (Economic Analysis of Cooling-Heating System Using Ground Source Heat in Horticultural Greenhouse)

  • 류연수;주혜진;김진욱;박미란
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.60-67
    • /
    • 2012
  • Government Geothermal Cooling-Heating Projects has made efforts to reduce GHG(Greenhouse Gas) emissions and to manage cost of greenhouse farm households. This study evaluated the economic benefits of heating load rate of change by comparing Geothermal Cooling-Heating System with the existing system(greenhouse diesel heating) in the Government Geothermal Cooling-Heating Projects. Economic analysis results shows that, 1) When installing the Cooling-Heating system according to the ratio of 70% heating load in policy standards, the geothermal cooling-heating system has economic efficiency with greenhouse type or scale independent because the investment cost is recovered within 7 years. And It was more economic efficiency the ratio of 50% heating load than70% heating load. 2) When installing the Cooling-Heating system according to the glass greenhouse of the ratio of 90% heating load, pay period of investment cost is recovered within 5 years. Therefore it is necessary to apply flexible heating sharing according to greenhouse type or scale.

로타리 킬른의 장입 특성이 온도분포에 미치는 영향 (The Effect of Feeding Characteristics on the Temperature Distribution of Rotary Kiln)

  • 박종석;전철균
    • 한국연소학회지
    • /
    • 제12권3호
    • /
    • pp.24-32
    • /
    • 2007
  • A theoretical model was developed for rotary kiln and computational study was conducted to find the effect of feeding characteristics. One dimensional model with the variations of heating distribution, length of heating zone, excess air ratio and revolution was considered. The comparison of parallel-flow rotary kiln with that of counter-flow was conducted. For parallel-flow type, it is found that the variation of temperature of solid is not great for the zone that is following flame-heating zone. This zone is good to take the special treatment because thermal deviation is small and contacting time is enough for another treatment. Increase of excess air ratio have the effect of decreasing solid temperature. But this effect of decreasing solid temperature goes small for the great excess air ratio. The heating is efficient for the flame which has the maximum heating at the central region of the full length.

  • PDF

Enhanced ICRF Heating of H-mode Plasmas in KSTAR

  • Kim, Sun-Ho;Wang, Son-Jong;Ahn, Chan-Yong;Kim, Sung-Kyew
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.317-317
    • /
    • 2011
  • Enhanced ICRF (Ion Cyclotron Range of Frequency) ion heating of H-mode D(H) plasma will be tried in 2011 KSTAR experimental campaign. Minority heating is a main ion heating scheme in the ICRF. Its efficiency increases as the hydrogen minority ratio increases in deuterium plasmas. And it should be sustained at a lower level than the critical minority ratio. Consequently, it is important to elevate the critical ratio to maximize ion heating and it is possible by increasing the ion temperature or parallel wave number (k${\parallel}$) of the antenna. Increasing the k${\parallel}$ is not a good approach since the coupling efficiency decreases exponentially with regard to k${\parallel}$ as well. So the remaining method is to increase ion temperature by using NB (Neutral Beam). Ion heating fraction of NB increases as the electron temperature increases. Therefore, we will try to heat electron by using ECH together with NB ion heating before ICRF power injection. The ICRF heating efficiency will be compared with respect to several NB+ECH+ICRF heating combinations through several diagnostics such as XICS (Xray Imaging Crystal Spectroscopy), CES (Charge Exchange Spectroscopy) and neutron measurement. The theoretical background and the experimental results will be presented in more detail in the conference.

  • PDF

액체식 태양열난방계통에 관한 연구 (A Study on the liquid Type Solar Heating System)

  • 남평우
    • 대한설비공학회지:설비저널
    • /
    • 제8권4호
    • /
    • pp.221-236
    • /
    • 1979
  • The three years Performance of a liquid type solar heating system has been determined for a system which has been determined for a system which has been operating continuously since 1976 in Seoul with no serious maintenance. A flat plate collector is used to transform incident solar radiation into thermal energy. This energy is stored if the form of sensible energy and used as needed to supply the space heating loads. An electric auxiliary heaters are provided to supply energy for space heating load when the energy in the storage tank is depleted. The ratio of useful collected solar heat divided by the total solar radiation on the collector was obtained about 84 per cent. It is also obtained the relation between ratio of solar collector area to the heating area and the ratio of useful collected solar energy to the heating load for the useful design data. A comparison between the measured and simulated results with the solar space heating system is described. Hour by hour simulation is made on unsteady state basis using the system parameters and meteorological data at the experiment site. The result of comparison turned out satisfactory for the solar heating system, though the simulation was formed somewhat higher than by experimental.

  • PDF

스탬퍼 가열/냉각을 이용한 고세장비 나노 구조물 성형 (Injection Molding of High Aspect Ratio Nano Features Using Stamper Heating/Cooling Process)

  • 유영은;최성주;김선경;최두선;황경현
    • 소성∙가공
    • /
    • 제16권1호
    • /
    • pp.20-24
    • /
    • 2007
  • Polypropylene substrate with hair-like nano features(aspect $ratio{\sim}10$) on the surface is fabricated by injection molding process. Pure aluminum plate is anodized to have nano pore array on the surface and used as a stamper for molding nano features, The size and the thickness of the stamper is $30mm{\times}30mm$ and 1mm. The fabricated pore is about 120nm in diameter and 1.5 um deep. For molding of a substrate with nano-hair type of surface features, the stamper is heated up over $150^{\circ}C$ before the filling stage and cooled down below $70^{\circ}C$ after filling to release the molded part. For heating the stamper, stamper itself is used as a heating element by applying electrical power directly to each end of the stamper. The stamper becomes cooled down without circulation of coolant such as water or oil. With this new stamper heating method, nano hairs with aspect ratio of about 10 was successfully injection molded. We also found the heating & cooling process of the stamper is good for releasing of molded nano-hairs.

열원 및 부하조건에 따른 물-공기 히트펌프 시스템의 성능분석 (Performance Analysis of Water-to-Air Heat Pump System under Water Temperature and Load Ratio)

  • 조용;이동근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.194.2-194.2
    • /
    • 2011
  • Heating and cooling performance has been analyzed for the water-source heat pump system using raw water from Daechung reservoir. During heating operation from March to May, water temperature is not good condition for a heat source due to the higher atmospheric temperature. Avearged heating load ratio is only 14.3%, and the averaged unit COP and system COP are estimated to be 2.46 and 2.15 respectively. The COP is affected considerably by the water temperature, and the unit COP is increased from 2.16 at $5^{\circ}C$ to 2.95 at $11^{\circ}C$. Cooling performance is analyzed with the measured data from June to August. During cooling operation, raw water has lower temperature by 4. $5^{\circ}C{\sim}4.7^{\circ}C$ than the atmosphere. The load ratio is 39.2%, and the averaged unit COP and system COP are estimated to be 7.25 and 6.13 respectively. The heating COP is affected by the load ratio rather than water temperature. The COP is increased for 20%~40% load ratio, while is decreased for 40%~60% load ratio. It is estimated that the compressor operation combination for 3 (two constant speed and one inverter) compressors is changed for the load ratio.

  • PDF

난류발생기를 가지는 원형 파이프내에서의 마찰저감 및 열전달율에 관한 실험적 연구 (Experimental Study on the Drag Reduction & Heat Transfer Ratio in the Circular Pipe with Swirl Generater)

  • 김성수;조성환;윤석만
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.430-435
    • /
    • 2008
  • Total lengths of domestic pipe network for district heating system are above about 2,500Km. A lots of pumping power for heat transportation through long pipe are required by the flow friction of pipe surface. Until now there have been considered about various methods to reduce the flow friction for district heating system such as using surfactants and turbulence promoters by swirl flow and baffles etc. At this study, swirl flow generator was tested about the possibility to increase the heat transfer ratio at the heat exchanger in the case which the suppling water temperature increased from $50^{\circ}C$ until $120^{\circ}C$. Experimental results showed that the heat transfer ratio increased and also pressure increase ratio increased simultaneously in the case which swirl flow generator installed. The amount of the increasing ratio for heat transfer and pressure were reached until 4.33% and 11% at the case of $120^{\circ}C$ suppling temperature which domestic district heating system were using.

  • PDF

가공조건에 따른 전지대두분 두부의 품질 및 관능평가 (Quality and Sensory Evaluation of Whole Soybean Flour Tofu Prepared from various Processing Conditons)

  • 김주영;김준하;김종국;문광덕
    • 한국식품영양과학회지
    • /
    • 제30권3호
    • /
    • pp.455-459
    • /
    • 2001
  • Tofu (soybean curd) was made with whole soybean flour (WSF, 420 mesh) by various processing conditions of water addition ratio, heating time, coagulation temperature, molding pressure and 0.3% of mixed coagulant (CaSO₄:GDL=50:50(w/w)). Yield content of WSF-tofu was the highest in processing condition of 85℃ coagulation temperature, 10 times water addition, 5min. heating time and 25.00 g/㎠ molding pressure. As the increase of the water addition ratio from 8 to 14 times (water:WSF, v/w), Hunter's L and a values were increased. Raising of heating time (100℃, 1, 5, 10 and 15 min), a and b value were increased. Textural properties of WSF-tofu were significantly affected by coagulation temperature (75, 80, 85 and 90℃). Hardness was increased, but adhesiveness and cohesiveness were decreased. heating time was influenced on harness of WSF-tofu, but water addition ratio was not affected on hardness of WSF-tofu. Increasing of molding pressure (16.83, 25.00, 33.22 and 41.67 g/㎠, 1 hr) was resulted from a increased hardness, gumminess and chewingss of tofu, but adhesiveness was addition ratio, 5 min heating time and 25.00 g/㎠ molding pressure recorded the highest score in sensory evaluation test.

  • PDF

가스인젝션을 적용한 이산화탄소 열펌프의 난방성능에 관한 실험적 연구 (Experimental Study on the Heating Performance of a $CO_2$ Heat Pump with Gas Injeciton)

  • 백창현;이응찬;강훈;김용찬;조성욱
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.358-363
    • /
    • 2007
  • In this study, experimental study on the heating performance of a $CO_2$ heat pump with gas injection was performed varying gas injection ratio and outdoor temperature to improve the heating performance of $CO_2$ heat pump. The twin rotary compressor having volume ratio of 0.7 was adopted in the $CO_2$ heat pump. From the test results, the heating capacity and COP were increased and the compressor discharge temperature was decreased with the increase of injection ratio. At the outdoor temperature of $-8^{\circ}C$, the heating capacity and COP with the injection were increased by 45% and 24%, respectively, compared with non-injection condition.

  • PDF