• Title/Summary/Keyword: Heating period

Search Result 539, Processing Time 0.03 seconds

Influence of Cooking, Storage Period, and Re-heating on Production of Cholesterol Oxides in Chicken Meat

  • Choe, Juhui;Min, Joong-Seok;Lee, Sang-Ok;Khan, Muhammad Issa;Yim, Dong Gyun;Lee, Mooha;Jo, Cheorun
    • Food Science of Animal Resources
    • /
    • v.38 no.3
    • /
    • pp.433-441
    • /
    • 2018
  • The objective of present study was to investigate the effect of cooking and their combinations with re-heating methods on the formation of cholesterol oxidation products (COPs) in stored chicken thigh meat. Pan roasting, steaming, oven grilling, charcoal grilling, and microwaving were used for cooking. Re-heating of samples was done using the same cooking methods or microwaving after 3 and 6 d of refrigerated storage. Cooking and re-heating resulted in reduction of crude fat and cholesterol contents of chicken thigh meat depending on storage period before re-heating. Cooking and storage period had no influence on the total amount of COPs. The highest total amount of COPs was observed in meat samples cooked by steaming and reheated by microwaving after 6 d of storage, which showed similar value to raw chicken meat stored for 6 days. However, different re-heating methods formed different types of COPs depending on storage period before re-heating. The high amount (p<0.05) of 25-hydroxycholesterol or ${\alpha}-epoxide$ was detected in meat samples reheated by steaming or microwaving at 3 or 6 d of storage after steamed cooking, respectively. As a result, the combination of steaming and re-heating with microwaving could increase the total amount of COPs in chicken thigh meat and different cooking/re-heating methods could form different types of COPs, even though no significant difference in the total amount of COPs depending on storage period.

Effects of Winter Heating on the Treatment Characteristics and Performance of Absorbent Biofilter System (흡수성 Biofilter System에서 동절기 가온이 처리 특성과 성능에 미치는 영향)

  • Kwun, Soon-Kuk;Cheon, Gi-Seol;Kim, Song-Bae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.6
    • /
    • pp.73-82
    • /
    • 2005
  • This study was performed to evaluate the need for heating wastewater to enhance treatment efficiency of organic matter (BOD, SS) during cold winter in newly developed Absorbent Biofilter System (ABS) which was established in the Suwon Campus of the Seoul National University. Treatments consisted of non-heating (2000 year) and heating(2001, 2002 year), and sampled data were analyzed during cold winter period as well as post winter period to investigate the influence of heating after winter season. Even the average air temperature showed only $0.4^{\circ}C$ difference between two experimental years, the difference in the average effluent temperature during cold winter period between heating and non-heating experiment was approximately $11^{\circ}C$. The average effluent concentration of organic matter in non-heating treatment exceeded the Korean standards for water quality of discharged effluent in riparian area (BOD and SS 10 mg/L); however, the standards were met in case of heating treatment during both winter and post winter period. Therefore, the need fur heating wastewater during cold winter season in ABS was justified. On the other hand, there was no improvement of treatment efficiency in T-N and T-p, but we observed the more activated nitrification as increasing the wastewater temperature. Because the average underground temperature was $5^{\circ}C$ higher than the average air temperature during cold winter period, we recommend that the ABS can be established in the underground rather than on-ground for saving the heating cost.

An Experimental Study of Moxa-Combustion Time by the Density of Moxa Material -On the point of time in the combustion stage- (애구(艾灸)의 연소(燃燒) 시간(時間)에 대한 실험적(實驗的) 연구(硏究) -구간별(區間別) 발현(發現) 시점(時點)을 중심(中心)으로-)

  • Park, Young-Bae;Kang, Sung-Keel;Koh, Hyung-Kyun;Oh, Hwan-Sup
    • The Journal of Korean Medicine
    • /
    • v.15 no.2 s.28
    • /
    • pp.241-252
    • /
    • 1994
  • It is known that the pattern of combustion temperature can be classified into preheating, heating. retaining and cooling periods. In this experiment. the authors have studied the heating mechanism by the density of moxa material during the heating and retaining periods. The starting point. the point at which it begins to reach the maximum gradient temperature. the ending point of the heating period. and the ending point of the retaining period were measured in order to get effective stmulation by repetition of moxa-combustion. For the experiment. samples of 300mg. 400mg, and 500mg of moxa material were molded into conical molds with each 10mm in diameter and height resulting in the volume of $0.26cm^3$. The following results were obtained: The $300mg/0.26cm^3$ denstiy sample reached al1 points tested faster than the samples of $400mg/0.26cm^3$ and $500mg/0.26cm^3$ It dose not reveal any statistical differences between $400mg/0.26cm^3$ and $500mg/0.26cm^3$ in the ending point. the point at which it begins to reach the maximum gradient temperature of the heating period or the ending point of the reataining period The only difference shown was in the starting point of the heating period. According to the above results. it is concluded that the lower density moxa material reached each point of the the respective period faster than the high density moxa material.

  • PDF

Effect of Measuring Period on Predicting the Annual Heating Energy Consumption for Building (연간 건물난방 에너지사용량의 예측에 미치는 측정기간의 영향)

  • 조성환;태춘섭;김진호;방기영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.287-293
    • /
    • 2003
  • This study examined the temperature-dependent regression model of energy consumption based on various measuring period. The methodology employed was to construct temperature-dependent linear regression model of daily energy consumption from one day to three months data-sets and to compare the annual heating energy consumption predicted by these models with actual annual heating energy consumption. Heating energy consumption from a building in Daejon was examined experimentally. From the results, predicted value based on one day experimental data can have error over 100%. But predicted value based on one week experimental data showed error over 30%. And predicted value based on over three months experimental data provides accurate prediction within 6% but it will be required very expensive.

The Experimental Study of Various Salts on the Characteristics of Heat Transfer in Indirect Moxibustion with Salt (염(鹽)의 종류(種類)에 따른 격염구(隔鹽灸)의 열전달(熱傳達) 특성(特性)에 관한 실험적(實驗的) 연구(硏究))

  • Lee, Geon-mok;Lee, Gun-hyee;Seo, Eun-mi
    • Journal of Acupuncture Research
    • /
    • v.21 no.1
    • /
    • pp.119-135
    • /
    • 2004
  • Objective: The purpose of this study is to investigate the mechanism and effect of moxibustion with salt objectively, to be used as the quantitative data through the measurement of temperature, and to grasp the thermodynamic characteristics of moxibustion with salt. Methods: We have selected of the moxibustion with salt of indirect moxibustion. We make a comparative study of the thermodynamic characteristics of moxibustion with salt as a kind of the 4 salt. We examined combustion times, temperatures, temperature gradients in each period during a combustion of moxa. Results: 1. We make out that it is not significantly change the time of thermal conduction of moxibustion with salt as a kind of 4 salt. 2. The heating period of Refined Salt was long and that of Sun-dried Salt was a short time respectively. The heating period of maximum tamperature is high Sun-dried Salt, Mechanical Salt and Refined Salt orderly. Maximun heating speed in the heating period was $0.151{\sim}0.184^{\circ}C/sec$ and at the same tendency of the maximum temperature in the heating period. 3. The retaining period was shorter than the heating period respectively, that is 15~24% of the combustion time of in the heating period. We make out that it is not significantly different the time of the retaining period as a kind of 4 salt. The mean temperature of retaining period was $43.2{\sim}48.1^{\circ}C$, that was extraordinarily high temperature. 4. We make out that it is not significantly different the time of the cooling period as a kind of 4 salt. The cooling period was measured 223~233sec. Beacuse the same density and size of moxa combustion was made an experiment. 5. The effective combustion time of Refined Salt is longer(259sec) than that of Sun-dried Salt(173sec). It is significantly different the time of the combustion time as a kind of 4 salt. 6. It is significantly different the Sample deviation of the combustion time as a kind of 4 salt because of the water content of the 4 salt individually. Conclusions: As the base on this study, we obtained the conclusion as the follows. The salt of moxibustion with salt was fitted for Sun-dried Salt due to making to Mechanical Salt recently. The Refined Salt is composition rate to another and small size comparatively. So It was fitted for the salt of moxibustion with salt. It is necessary to study continuously about the more suitable moxibustion with salt and quantitative analysis about the moxibustion with salt.

  • PDF

Analysis for the Economic efficiency of District Heating and Gas Engine Co-generation System comparing with Central Heating System (중앙난방방식을 지역난방.소형열병합난방방식으로 전환시의 경제성 비교 분석)

  • Kim, Kyu-Saeng;Lee, Sang-Hyeok;Hong, Kyung-Pyo;Won, Young-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.459-465
    • /
    • 2007
  • This study was conducted to calculate the LCC of a apartment complex with a type of heating system, district heating and cogeneration system. For the purpose of analyzing LCC according to size of apartment complex, 500, 1,500 and 4,000 houses of model apartment selected. This research performs design of heating system and the life cycle cost analysis including an initial cost, energy cost, maintenance and operation cost, replacement cost and renovation cost during the project period(15years). According to the calculated results, 1) Initial cost of cogeneration system with 500, 1500 and 4000 houses is higher than district heating system each of 20%, 13%, 12%. 2) In case of cogeneration system, the payback period by electric generation is 5.21, 4.92 and 4.47 years and saving cost was calculated 29 billion won, 94 billion won and 262 billion won after payback period. 3) Cogeneration system LCC was 1.12, 1.07 and 1.06 times larger than district system with the size of apartment complex. According to the case of this study district heating system is more efficient than cogeneration system in terms of the reduction of LCC. 4) Gas Engine Co-generation System is more efficient than other systems because it can collect progressive part from electric charge progressive stage system. However, the efficiency is decreasing because of raising of fuel bills(LNG) and lowering of power rate for house use. Especially the engine is foreign-made so the cost of maintenance and repair is high and the technical expert is short. 5) District heating is also affected by fuel bills so we should improve energy efficiency through recovering of waste heat(incineration heat, etc.). Also, we should supply district cooling on the pattern of heat using of let the temperature high in winter and low in summer.

  • PDF

Analysis of the Economic Efficiency of the District Heating and Gas Engine Co-Generation System Compared with the Central Heating System (중앙난방방식을 지역난방과 소형열병합난방 방식으로 전환 시 경제성 비교 분석)

  • Kim, Kyu Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.544-551
    • /
    • 2015
  • This study was conducted to determine the LCC of apartment complexes with district heating and a cogeneration system. For the purpose of analyzing LCC according to the size of the apartment complex, 500, 1,500, and 4,000-unit model apartments were selected. Analysis was performed on the design of the heating system and the life cycle cost including total construction cost, maintenance and operation cost for the duration of the project period (15 years). According to the calculated results, 1) The initial cost of the cogeneration system for 500, 1,500, and 4,000-unit apartments is higher than that of the district heating system by 20%, 13%, and 12%, respectively. 2) In the case of the cogeneration system, the payback period by electric generation was found to be 5.21, 4.92 and 4.47 years, and saving cost was calculated to be 29 billion won, 94 billion won and 262 billion won after the payback period for 500, 1,500, and 4,000-unit apartments, respectively. 3) The LCC values of the cogeneration system were 1.12, 1.07 and 1.06 times larger than those of the district system according to the size of the apartment complex. In this study, the district heating system was found to be more efficient than the cogeneration system in terms of LCC reduction. 4) District heating is affected by fuel bills, so energy efficiency should be improved through recovering waste heat (incineration heat, etc.). Also, district cooling should be provided according to heat use to keep the temperature high in winter and low in summer.

Economic evaluation on heating systems of apartment complex (공동주택단지 난방시스템들에 대한 경제성 평가)

  • 조금남;윤승호;김원배
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.773-783
    • /
    • 1998
  • The heating system for apartment complex may be classified as old systems including central system with steam boiler(S1), gas engine driven heat pump system(S2), system using waste heat(S3) and new systems including mechanical vapor re-compression system with flashing heat exchangers(S4), system using methanol(S5), system using metal hydride (S6). The purpose of the present study is to suggest optimal heating system by technically, economically and environmentally evaluating old and new heating systems of apartment complex from 500 to 3,000 households. Economic evaluation based on the technical evaluation results which estimated heat transfer area of heat exchangers and capacity of equipments was estimated initial investment cost, annual operating cost and relative payback period by considering annual increasing rates of energy cost and interest. Environmental evaluation provided annual generation rate of carbon dioxide. Initial investment cost was cheap in the order of S6, S5, S3, S2, S4, S1, annual operating cost was cheap in the order of S1, S2, S4, S5 and relative payback period was short in the order of S6, S5, S2, S3 and S4. Relative payback period was within 8 years for all scenarios of 3,000 households, and was increased as annual increasing rates of energy cost and interest were increased. As transportation pipe length was increased twice, payback period was increased by 1.4~2.6 time. The effect of temperatures of waste gas and waste water on the relative payback period was small within 0.8 years. The annual generation rate of carbon dioxide was big in the order of S4, S2 and S1. S4 was the most economic system among whole scenarios when S1 was replaced with other scenarios.

  • PDF

A Study on thermal performance of box type double skin facade and curtain wall in heating period (박스형 이중외피와 커튼월 창호의 난방기 열적성능 비교)

  • Park, Chang-Young;Choi, Chang-Ho;Lee, Keon-Ho;Yoon, Yong-Sang
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.909-914
    • /
    • 2006
  • The purpose of this study is to analyze the thermal of DFS(double Facade System) and curtain wall in the heating period. The physical difference between curtain wall and double facade on thermal performance has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. This study divide on 'ventilated, airtight' and 'heated or unheated' conditions from the CASE 1, 2, 3, 4. The results showed thermal performance of double facade system which has been better than curtain wall. The heating energy of DFS reduced $8%{\sim}10%$ of energy consumption. comparable to SFS in experemted results. In view of the researching results so far achieved, the research came to a conclusion, that the curtain wall can save the energy in the heating period than a curtain wall.

  • PDF

Experimental Study on the Stimulating Effect of Commercial Moxa Combustion through the Measurement of Temperature -Focused on Combustion time and temperature- (온도 측정을 통한 상용 쑥뜸의 자극효과에 대한 실험적 연구 -연소시간 및 연소온도를 중심으로-)

  • Lee, Geon-Mok;Yang, Yoo-Sun;Lee, Gun-Hyee
    • Journal of Acupuncture Research
    • /
    • v.19 no.2
    • /
    • pp.114-127
    • /
    • 2002
  • Objective : The purpose of this study is to investigate the mechanism and effect of moxibustion objectively and to be used as the quantitative data for developing the new thermal stimulating treatment by observing the combustion time and temperature of commercial moxaes. Methods : We have selected two types(large-size moxa A(LMA), large-size moxa B (LMB)) among large moxaes used widely in the clinic. We examined combustion times, temperatures in each period during a combustion of moxa. Results : 1. The combustion time in the preheating period was about 30sec in both moxaes on the non-contact heated surface. 2. The combustion time in the heating period was about 345sec in LMA and about 1391 sec in LMB, about 4 times longer in LMB on the non-contact surface. 3. The maximum temperature in the heating period was $44.5^{\circ}C$ in LMA and $45.4^{\circ}C$ in LMB respectively, higher by $0.9^{\circ}C$ in LMB. The average temperature in the heating period was $35.5{\sim}37.6^{\circ}C$ in LMA and $36.0{\sim}39.8^{\circ}C$ in LMB, a little higher in LMB. 4. The combustion time in the retaining period in LMA was 45.4sec and 13% of that in the heating period, and in LMB 594.7sec and 43% of that in the heating period on the non-contact surface. 5. On the point(PH) measured maximum temperature, the average temperature during the retaining period was $44.0^{\circ}C$, $42.9^{\circ}C$ respectively and the temperature at an end of the retaining period was $43.0^{\circ}C$, $40.2^{\circ}C$ respectively. 6. The time at a beginning of the cooling period was about 418 sec from ignition in LMA and 2021sec in LMB, and the temperature at that time was $36.9{\sim}39.1^{\circ}C$ on the non-contact surface. Conclusion : It was thought that not only the figure of moxicombustion device, but also the form and size of moxa had influence on the combustion characteristics deciding the performance of stimulus seriously.

  • PDF