• Title/Summary/Keyword: Heating methods

Search Result 1,007, Processing Time 0.027 seconds

Characterization of LaCrO$_3$ Powders Synthesized by Combustion Process with Different Heating Methods (가열방법에 따른 LaCrO$_3$ 연소합성분말의 특성)

  • 정층환;박홍규;오석진;박지연
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.10
    • /
    • pp.1078-1084
    • /
    • 1998
  • lanthanum chromite(LaCrO3) powder was synthesized by the combustion of a solution of metal nitrates La(NO3).6H2O and Cr(NO3)3.9H2O and urea. The pH of solution affected a yield of the combustion products but did not influence the morphology of the products. When the pH of the solution was in the range of 0.7-4, the yield of the combustion products was more than 90% The morphology of the combustion products was af-fected by heating methods for the solution. The hot-plate induced heating of the solution yielded powders hav-ing two-dimensionally interconnected agglomerates whereas microwave-induced heating produced a fine and non-agglomerated powders. The specific surface area(BET) of the combustion products using microwave-in-non-agglomerated powders. The specific surface area(BET) of the combustion products using microwave-in-duced heating method were larger(25~32m2/g) than that of hot plate heating method(10-14m2/g)

  • PDF

Evaluating optimal preprocessing method for separation of microalgae colonies into single cells for image quality (미세조류 이미지 품질 성능 향상을 위한 최적 전처리방법 선정 연구)

  • Sang Yeob Kim;Sung Kyu Maeng
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.2
    • /
    • pp.109-117
    • /
    • 2024
  • In this study, various pre-treatment methods were evaluated for microalgae separation. These methods aimed to facilitate safe, rapid, and cost-effective online imaging for real-time observation and cell counting. As pre-treatment techniques, heating, chemical hydrolysis, heating combined with chemical hydrolysis, and sonication were employed. The effectiveness of these methods was evaluated in the context of online imaging quality through experimentation on cultivated microalgae (Chlorella vulgaris and Scenedesmus quadricauda). The chemical treatment method was found to be inappropriate for improving image acquisition. The heating pre-treatment method exhibited a drawback of prolonged cell dispersion time. Additionally, the heating combined with chemical hydrolysis method was confirmed to have the lowest dispersion effect for Chlorella vulgaris. Conversely, ultrasonication emerged as a promising technique for microalgae separation in terms of repeatability and reproducibility. This study suggests the potential for selecting optimal pre-treatment methods to effectively operate real-time online monitoring devices, paving the way for future research and applications in microalgae cultivation and imaging.

A Thermal Performance Analysis on the Operation Modes of Radiant Floor Heating System Using SERI-RES (SERI-RES를 이용한 Radiant Floor Heating System의 열 성능 분석)

  • Chun, Won-Gee;Jeon, Myung-Seok;Auh, P.Chung-Moo
    • Solar Energy
    • /
    • v.11 no.2
    • /
    • pp.29-33
    • /
    • 1991
  • The present paper deals with two types of heating methods widely used for the Radiant Floor heating systems in Korea. Of these, one method circulates hot water according to the predefined schedule ("intermittent heating") while the other runs the system with the aid of thermostats ("continuous heating"). The standard version of SERI-RES has been modified for the numerical simulation of the problem. Preliminary results show relatively large temperature swings in the case of intermittent heating with solar availability. On the other hand, the case of continuous heating would avoid such undesirable temperature fluctuations. These results are also verified by experimental evaluations.

  • PDF

A Study on the Modernization of the Heating Method of Apartment Houses in the 1950s and 1960s Korea - Focusing on Haengchon, Jongam, Mapo Apartments - (1950~60년대 한국 아파트의 난방 방식 근대화에 관한 연구 - 행촌, 종암, 마포아파트를 중심으로 -)

  • Lee, Byoung-Heon;Kim, Hyon-Sob
    • Journal of architectural history
    • /
    • v.30 no.6
    • /
    • pp.33-44
    • /
    • 2021
  • The traditional Korean heating system ondol, one of the most important characteristics of Korean architecture, still remains as hydronic floor heating. Various studies have been conducted on the modernization of ondol, but the process of introducing the hydronic floor heating has not been seriously studied so far. Therefore, this paper aims to demonstrate how the hydronic floor heating had been introduced to Korea, taking the 1950s and 1960s Haengchon, Jongam, and Mapo Apartments for example - these three are regarded as the first Korean apartment houses after the Korean War. While Western advanced construction technology was imported for these apartments, various methods of modernizing ondol were also considered. What was remarkable in these attempts is that hydronic floor heating first appeared in Mapo 1st Apartment in 1962, because this is the universal heating method in the present Korea. This fact signifies that the traditional principle of floor heating has been maintained, and it would also be meaningful in terms of architectural exchanges between East and West, if considered along with Wright's application of the Korean heating principle to his houses since 1930s.

Application of Curing Method Using the Heating Cable for Cold Weather Concreting (매입형 열선에 의한 한중콘크리트의 보양방법 적용에 관한 연구)

  • 김형래;이정철;김찬수;이명진;김봉주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.769-774
    • /
    • 2001
  • The purpose of this study is to analyze the curing effect of heating cable for concreting in cold weather. An experiment was conducted to evaluate the temperature history of concrete structures cured with embedded heating cables. Results are as follows : In comparison with the non-heating case, applying of heating cable resulted in the rise of temperature in the range of $10^{\circ}C$. In order to get successful results, the optimal pitch length for the embedded heating cables ranged from 20cm to 25cm. When working with the existing curing methods, applying this heating cable would be more effective in concrete curing. Finally, a formula and process was suggested to predict the Internal temperature history of concrete structures under the various curing conditions.

  • PDF

Control Characteristics with Flow Rate Control Methods in Central Heating System (중앙난방시스템의 유량제어방식에 따른 제어특성 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.1
    • /
    • pp.32-37
    • /
    • 2011
  • In this study, control characteristics and energy performance with flow rate control methods were reviewed with the simulation. The heating system is classified such as fan coil unit and HVAC system currently used in buildings with valve control and pump inverter control. The simulation analysis program is made by TRNSYS ver. 15 with the actual data. As a result of this study, the central heating system with pump inverter control decreases electricity energy and reduces gas consumption. Inverter control method shows better performance in comparison with valve control one for energy saving.

The Changes in Quality of Sugars Chestnuts by Sugars and Heating Methods (당의 종류 및 가열방법에 따른 당침밤 제품의 품질 변화)

  • 홍순갑;황태영
    • Food Science and Preservation
    • /
    • v.4 no.2
    • /
    • pp.173-180
    • /
    • 1997
  • The effects of sugars and heating methods on the sugar infilteration, hardness, color and organoleptic characteristics were investigated for quality improvement of sugared chestnuts. Among the tested sugars, isomaltooligosugar was the most effective on the rate of sugar infilteration. High temperature increased the rate of sugar infilteration during sugaring process, but color and flavor were deteriorated at 9$0^{\circ}C$. The most suitable temperature for sugaring process was 7$0^{\circ}C$. The product sugared with fructooligosugar recoreded the highest score in hardness, odor and preference than any other sugars tested and increased the rate of sugar infilteration when mixed with sugar at same amount. The changes of soluble solids in chestnuts boiled with microwave oven were ranged from 18。Brix to 32。Brix, while chestnuts heated in general were from 18。Brix to 28。Brix. Chestnuts boiled with microwave heating were sugared rapidly. The hardness of boiled and sugared chestnuts was lower when treated with microwave than with general heating. Hunter's L and b value of sugared chestnut treated with microwave decreased during processing but a value somewhat increased.

  • PDF

A Experimental Study on the Application of GRNN for On-Off Control in Floor Radiant Heating System (바닥복사 난방시스템의 개폐식 제어에 대한 GRNN 적용에 관한 실험적 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.4
    • /
    • pp.16-23
    • /
    • 2020
  • In this study, the control characteristics and effects of control methods on heating performance and energy consumption for the hot water floor radiant heating control system of a residential apartment were research by experiment. As a control method, On-Off control and outdoor reset control methods with GRNN(General Regression Neural Network) and without GRNN are considered. Also, the control performances with regard to improvement of indoor thermal environment and reduction of energy consumption are compared, respectively. Experiment results show that the performance of the control method with GRNN is better than that of conventional on-off control method without GRNN in the responses of room set temperature and energy saving.

The Characteristics of Line Heating Using Hydrox Gas (수산소 혼합가스를 이용한 선상가열 특성)

  • Kim, Hong-Gun;Kwac, Lee-Ku
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.4
    • /
    • pp.407-411
    • /
    • 2011
  • The technology of line heating has evolved in various methods. Among them, fossil fuels like ethylene gas and LPG(Liquid Petroleum Gas) are widely used due to their simple utility. In the meantime, the technology implementing high frequency for line heating has also been developed continually, but its manufacturing technology or application includes lots of problems by now. One of the main characteristics of line heating using conventional technolob'Y is the quenching effect followed by heating process. On the other hand, hydrox gas which is mixed by hydrogen and oxygen is a prominent candidate for an application without above shortcomings. Especially, it is found that line heating using hydrox gas is tremendously effective taking low cost as well as low noise. In this paper, a small cell with high efficiency which can minimize installing space is developed to deal with the problem installing in narrow place. Experiments to prove the validation, efficiency and effectiveness is carried out by characterizing in the line heating of steel. It is found that the energy saving of using hydrox gas for line heating is significant and that the deviation performance is reduced by 78~89%. Furthermore, the noise is also reduced as amount of 18.3% though the heating time is not too different.

Characteristics of Torrefaction with Water Hyacinth

  • Song, Dae Bin;Kim, Min Soo
    • Journal of Biosystems Engineering
    • /
    • v.38 no.3
    • /
    • pp.180-184
    • /
    • 2013
  • Purpose: This study explored the factors influencing heating value in the process of torrefaction of water hyacinth. Methods: Torrefaction was applied with three temperature settings (200, 300, $400^{\circ}C$) and three time settings (1, 2, 3 h) using small electric heaters (11.3L of holding volume). This study investigated the heating values with the washing process and process factors influenced the torrefaction. In addition, this study compared the heating values in washed and unwashed samples and suggested the optimal conditions for increasing heating value. Results: Torrefaction increased the heating value by 8.18 ~ 30.04%. Comparing heating values of each condition, the optimal temperature for torrefaction was $300^{\circ}C$ and holding time was 1 hour. The washing process increased the heating value by 19 ~ 27%. The heating value of the sample treated at $300^{\circ}C$ for three hours was 4310.80 kcal/kg, which was greater than the first class wood pellet of 4300 kcal/kg. Conclusions: This study proved that the torrefaction and washing process increased the heating value of water hyacinth. Therefore, water hyacinth is expected to be an eco-friendly biomass which substitutes for wood pellet.