• Title/Summary/Keyword: Heating methods

Search Result 1,007, Processing Time 0.025 seconds

Rapid Preparation and Quality Control of $^{99m}Tc$-ECD, $MAG_3$ and MIBI using Microwave Heating and Sep-Pak Cartridges (마이크로웨이브와 Sep-Pak 카트리지를 이용한 $^{99m}Tc$-ECD, $MAG_3$, MIBI의 신속한 제조 및 정도관리)

  • Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.430-438
    • /
    • 1999
  • Purpose: We evaluated a rapid preparation procedures for the labeling and quality control of $^{99m}Tc$-ECD, $MAG_3$, and MIBI using microwave heating and Sep-Pak cartridges. Materials and Methods: $^{99m}Tc$ labeling of ECD, $MAG_3$, and MIBI kit preparation was performed according to the package inserts with microwave heating modification. Heating time was 10-15 sec, and heating was performed with 3 mm plastic bottle with screw cap to prevent radiation contamination. Labeling efficiency was obtained with $C_{18}$ or Alumina N Sep-Pak cartridges. Results: The radiochemical purity of $93{\sim}96%$ for $^{99m}Tc$-ECD and $95{\sim}99%$ for $^{99m}Tc$-MIBI was obtained using Alumina N Sep-Pak cartridge. The optimum irradiation time of microwave method for 3 ml $^{99m}Tc$-labeled radiopharmaceutical solution was 10 sec for $^{99m}Tc$-ECD and $^{99m}Tc$-MIBI, and 15 sec for $^{99m}Tc-MAG_3$. The results of quality control data with Sep-Pak cartridges were well correlated with TLC method. The total preparation time of these radiopharmcaeuticals was $5{\sim}6min$ including quality control procedure. Conclusion: This study demonstrates that radiopharmaceuticals preparation by microwave heating and quality control by Sep-Pak cartridges can be efficiently utilized as an alternative to the recommended method by manufacturer's manual.

  • PDF

Studies on the Characteristics of Rubber Vulcanization Exotherm by Differential Scanning Calorimetry. (Differential Scanning Calorimetry에 의(依)한 고무의 가황발열특성(加黃發熱特性)에 관(關)한 연구(硏究))

  • Choi, Sei-Young;Paik, Nam-Chul
    • Elastomers and Composites
    • /
    • v.19 no.1
    • /
    • pp.13-31
    • /
    • 1984
  • The purposes of this dissertation are to demonstrate that DSC theromoanaytical methods of vulcanization can provide useful informations on the vulcanization characteristics of industrial formulations and also provides the potential basis for a rapid and complete method of sulfur and vulcanizing accelerator analysis for quality control. The influences of those factors such as heating rate, scan temperature, vucanizing accelerator's type and concentration upon vulcanization exotherm in NR and NBR compounds in the presence of vulcanizing accelerators such as TMTD,MBTS,DPG,TMTM,CBS, and MBT were evaluated by means of DSC. In order to examine the credibility in the DSC method, the same samples which were used for DSC method were studied to compare the DSC results with the ODR (Oscillating Disk Rheometer) data. The results obtained were as follows 1. In the DSC dynamic experiments, the observed enthalpy results from vulcanization depends upon the heating rate; In the range of 2 to $20^{\circ}C/min$ of heating rate, as the heating rate was increased the enthalpy change was also increased. However, over the heating rate of $30^{\circ}C/min$ it was observed that the enthalpy change was decreased as the heating rate was further increased. Without regard to the change of enthalpy, tremendous instantaneous heat evolving was observed in the range of high heating rates. 2. For the samples which are added with various vulcanizing accelerators, the activation energies of vulcanization were as follows; 3. Regarding to the influences of vulcanizining accelerator's types upon the characteristics of vulcanization exotherm, NR and NBR compounds in the presence of thiuramsulphide compounds type accelerators such as TMTD, TMTM, were exhibited sharper and higher vulclanization exotherm than others. From the resuts of DSC thermograms which was distributed in even shape in the broad temperature range, it was clearly shown that the guanidine compounds type accelerator such as DPG acts as a delayed acting accelerator. 4. In the comparison of DSC and ODR results, the dependency of temperature in the cure rate and the observed conversions show good agreements between two results. 5. In the same curatives, by the comparison of glass transition temperatures, it was possible to predict relative values of maximum torques. Consequently, from the present studies, it is shown that the DSC thermoanalytical method can provide an alternate new method for rapid and complete quality control analysis of rubber industry.

  • PDF

Development of a Method for Producing Liposome Ascorbic acid with Increased Bio-absorption (생체 흡수율이 증가된 liposomal ascorbic acid 제조법 개발)

  • Cha, Ji Hyun;Woo, Young Min;Jo, Eun Sol;Cha, Jae Young;Lee, Sang Hyeon;Lee, Keun Woo;Kim, Andre
    • Journal of Life Science
    • /
    • v.32 no.3
    • /
    • pp.232-240
    • /
    • 2022
  • Various methods are known for preparing liposomes, the simplest being the Bangham method which has been widely used. Although it is possible to produce liposomes effectively on a small experimental level with this approach, large-scale production cannot be easily performed due to difficulties in removing the organic solvent and the size of the reactor required to form the lipid film. On the other hand, emulsion can mass produce tons of liposomes with uniform particles but has the disadvantage of a significantly low capture rate. This study therefore developed an optimal liposome processing method using heat with improved capture rate and stability, and bio-absorption experiments were performed by oral administration to SD rat alongside capture rate, particle size, and zeta potential. Through the heating method, a small and uniform liposome of about 214 nm was formed and the capture rate was 38.67%, confirming that the liposome prepared by heating has a higher capture rate than the 26.46% achieved through emulsion. Comparing blood concentrations, it showed a 1.5 to 2 fold increase in all groups, gradually decreasing until 4-12 hr. The highest blood concentration of ascorbic acid powder was about 12.017 ㎍/ml, the emulsion liposome 13.871 ㎍/ml, and the heating liposome 16.322 ㎍/ml, thereby showing an improved absorption rate.

The Study to Suggest a Methods to Evaluate Heating and Cooling Energy Performance based on Daily Life (실생활기반 냉난방에너지 성능평가 방법 제안 연구)

  • Jeon, Gangmin;Lee, Heangwoo;Kim, Yongseong
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.5 no.3
    • /
    • pp.291-299
    • /
    • 2015
  • With recent surge of attention to heating and air conditioning energy consumption, the need for evaluating performance of heating and air conditioning energy is also on the rise. This research aims to propose daily-life based evaluation method as an alternative to existing one, as well as to apply the method in real life to prove its validity. The results are as following. 1) I studied temperatures preferred by persons indoors and appropriate level of temperature, and the results show that properties of such persons such as age is directly linked with pleasantness of the room, but the issue lies with the fact that such properties are not considered in existing performance evaluation of heating and air conditioning. 2) Daily life based evaluation proposed herein reflects such properties of persons indoors. It controls heating / air conditioning devices installed in the test bed with the same size as a real life room to get quantitative and visual performances in our daily life as well as simple temperature information. 3) To verify validity of daily life based evaluation, I conducted different evaluation sessions with and without a blind and also based on ages of persons indoors. Results based on properties of persons showed difference of 77.6%, leading to effective analysis of energy consumption pattern by heating / air conditioning devices. This research takes significance in that it comes with a new performance evaluation method based on real life, and I gather that further studies are required to develop more multilateral performance evaluation in order to verify and improve technology for reduction of energy consumption.

Conservation Properties of Chalk Added Functional Lining Papers (기능성 배접지의 보존 특성 분석 -호분지-)

  • Choi, Kyoung-Hwa;Park, Ji-Hee;Seo, Jin-Ho
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.79-88
    • /
    • 2010
  • Paper cultural heritages experience chemical and physical deterioration due to various factors including preservation environments and the property of paper materials1). Thus, it is important to develop optimal preservation and restoration methods for the damaged paper cultural heritages. Currently, lining is a popular treatment for the restoration of paper cultural heritages in Korea. Since lining paper is a layer of paper directly attached to the inside of cultural heritages for protection, understanding of the preservation properties of lining paper is primarily needed in order to devise the better preservation methods. The main material of lining paper is the paper mulberry, but additives such as chalk and white clay is sometimes used to enhance the preservation properties of lining paper. To date, the properties of the functional lining paper containing these additives have been not fully understood yet. In this study, dry heating aging at $105^{\circ}C$ and biological aging by the Aspergillus versicolor and Penicillium polonicum for the lining paper, which is made from paper mulberry and the chalk, are carried out to evaluate changes in their preservation properties by these aging factors. As a result, it is found that the functional lining paper containing 25.1% of chalk can control the growth of fungi, while the paper containing 32.7% of chalk do not show any protection effect. However, the functional lining paper added by chalk is more aged than the lining paper made from paper mulberry by dry heating accelerated aging.

  • PDF

Optimal Conditions for the Wet Funnel Extraction of Enchytraeidae from Peat Soils of Moorlands in England (영국 고원지대(Moorland)의 이탄 토양에서 애지렁이 추출을 위한 수분깔때기의 최적조건)

  • ;H.I.J.Black;P.Ineson
    • The Korean Journal of Soil Zoology
    • /
    • v.5 no.2
    • /
    • pp.63-70
    • /
    • 2000
  • The effect of combinations of temperature, water column height and extraction time onthe efficiency of wet funnel extraction methods for enumerating Enchytraeids in a blanket bog peat soil from Moor House, Cumbria, England were investigated. The optimal conditions for extracting enchytraeids from this study were found to be a water surface temperature of 35$^{\circ}C$, with an extraction time of 6 hours, regardless of initial water temperature and water level in the extraction funnel. The original O'Connor method (40-45$^{\circ}C$ for 3 hours extraction and gradually increasing heating) yielding a high variation in the extraction efficiency, largely due to the comparatively higher temperature and shorter extraction time than this method. Attempts to extract without heat over longer periods showed very low extraction efficiencies for this highly organic blanket bog soil when compared with any of the heating wet funnel methods.

  • PDF

Characterization on Co-Combustion of Coal and Paper Mill Sludge (석탄과 제지슬러지 혼소에 따른 연소특성에 관한 연구)

  • Lee, Kamp-Du;Ryu, Tae-Uk;Park, Sang-Won
    • Journal of Environmental Science International
    • /
    • v.22 no.3
    • /
    • pp.331-339
    • /
    • 2013
  • Efforts were made to determine the activation energy and the reaction order by adopting Kissinger and Flynn-Wall-Ozawa analysis methods. All the data were acquired from TGA thermograms for the mixed fuels with different temperature heating rates. It could be known that both the coal and the mixed fuels decomposed thermally at temperature ranges of $300{\sim}700^{\circ}C$. The temperature at the maximum reaction rate, Tp, could be determined by DTG method, which could be obtained by differentiation of TGA thermogram. Kissinger analysis showed the linear relationship with experimental data, showing the activation energy of $319.64{\pm}4$ kJ/mol. From Flynn-Wall-Ozawa analysis, it was shown that the activation energies and the reaction orders did not undergo any significant changes with both the conversions and the heating rates. It was considered from this facts that the combustion mechanism of the mixed fuels could not be affected by the extent of conversion and heating rate. In the present study, the activation energies showed different values according to the different analysis methods. The difference might be originated from the inconsistency of the mathematical data treatment method. In other words, while the activation energies obtained from the Kissinger method indicated the average values for overall reaction, that from Flynn-Wall-Ozawa method showed the average values for the each conversion around Tp.

Actual Energy Consumption Analysis on Temperature Control Strategies (Set-point Control, Outdoor Temperature Reset Control and Outdoor Temperature Predictive Control) of Secondary Side Hot Water of District Heating System (지역난방 2차측 공급수 온도 제어방안(설정온도 제어, 외기온 보상제어, 외기온 예측제어)에 따른 에너지사용량 실증 비교)

  • Cho, Sung-Hwan;Hong, Seong-Ki;Lee, Sang-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.137-145
    • /
    • 2015
  • In this study, the actual energy consumption of the secondary side of District Heating System (DHS) with different hot water supply temperature control methods are compared. Three methods are Set-point Control, Outdoor Temperature Reset Control and Outdoor Temperature Prediction Control. While Outdoor Temperature Reset Control has been widely used for energy savings of the secondary side of the system, the results show that Outdoor Temperature Prediction Control method saves more energy. In general, Outdoor Temperature Prediction Control method lowers the supply temperature of hot water, and it reduces standby losses and increases overall heat transfer value of heated spaces due to more flow into the space. During actual energy consumption monitoring, Outdoor Temperature Prediction Control method saves about 7.1% in comparison to Outdoor Temperature Reset Control method and about 15.7% in comparison to Set-point Control method. Also, it is found that at when partial load condition, such as daytime, the fluctuation of hot water supply temperature with Set-point Control is more severe than Outdoor Temperature Prediction Control. Therefore, it proves that Outdoor Temperature Prediction Control is more stable even at the partial load conditions.

A Study on Residual Stress Measurements by Using Laser Speckle Interferometry (레이저 간섭법을 이용한 잔류응력 측정 방법에 대한 연구)

  • Rho, Kyung-Wan;Kang, Young-June;Hong, Seong-Jin;Kang, Hyung-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.1
    • /
    • pp.16-24
    • /
    • 1999
  • Residual stress is one of the causes which make defects in engineering components and materials. And interest in the measurement of residual stress exists in many industries. There are commonly used methods by which residual stresses are currently measured. But these methods have a little demerits. time consumption and other problems. Therefore we devised a new experimental technique to measure residual stress in materials with a combination of laser speckle pattern interferometry, finite element method and spot heating. The speckle pattern interferometer measures in-plane deformations while the heating provides for very localized stress relief. FEM is used for determining heat temperature and other parameters. The residual stresses are determined by the amount of strain that is measured subsequent to the heating and cool-down of the region being interrogated. A simple model is presented to provide a description of the method. In this paper, the ambiguity problem for the fringe patterns has solved by a phase shifting method.

  • PDF

Innovative Transient Thermal Gradient Control to Prevent Early Aged Cracking of Massive Concrete (매스콘크리트의 열경사 조절에 의한 수화열과 온도균열의 방지)

  • Kim, Seong-Soo;Cho, Tae-Jun;Lee, Jeong-Bae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.164-172
    • /
    • 2008
  • The heat of hydration for early aged mass concrete induces high temperature with the hydration. Control of the temperature difference across a section is an effective strategy to minimize the hydration heat induced cracks for the structures where internal restraint is dominant. The current prevention methods for hydration cracking show some limitations for the control of thermal gradients, and these limitations could make micro and macro cracks in surface and core of concrete. Especially cooling methods can decrease the increasing hydration temperature, but it can not prevent the problem while decreasing temperature. Consequently heating pipes are added simultaneously with the cooling pipes in order to control the temperature gradients between core and surface of the concrete, followed by the finite element analysis (FEA). Based on the FEA, the proposed method using cooling pipe and heating pipes together has been found to be an effective alternative in thermal gradient control, in terms of controlling temperature induced cracks significantly.