• Title/Summary/Keyword: Heating methods

Search Result 1,007, Processing Time 0.025 seconds

A comparative study of ultra-trace-level uranium by thermal ionization mass spectrometry with continuous heating: Static and peak-jumping modes

  • Lee, Chi-Gyu;Park, Ranhee;Park, Jinkyu;Lim, Sang Ho
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1532-1536
    • /
    • 2020
  • For ensuring nuclear safeguards, we report the analytical signal-detection performance of thermal ionization mass spectrometry (TIMS) with continuous heating for the measurement of isotopic ratios in samples containing ultra-trace amounts of uranium. As methods for detecting uranium signals, peak-jumping mode using a single detector and static mode using multiple detectors were examined with U100 (10% 235U-enriched) uranium standard samples in the femtogram-to-picogram range. Uranium isotope ratios, n(235U)/n(238U), were measured down to levels of 1 fg and 3 fg in static and peak-jumping modes, respectively, while n(234U)/n(238U) and n(236U)/n(238U) values were measured down to levels of 100 fg in both modes. In addition, the dependency of the 238U signal intensity on sample quantity exhibited similar tendencies in both modes. The precisions of the isotope ratios obtained in the static mode over all sample ranges used in this study were overall slightly higher than those obtained in peak-jumping mode. These results indicate that isotope ratio measurements by TIMS with continuous heating are almost independent of the detection method, i.e., peak-jumping mode or static mode, which is characteristic of isotope-ratio measurements using the TIMS method with continuous heating. TIMS with continuous heating is advantageous as it exhibits the properties of multiple detectors within a single detector, and is expected to be used in various fields in addition to ensuring nuclear safeguards.

The Analgesic Effects of Automatically Controlled Heating Acupuncture (자동가열침의 진통 효과)

  • Park, Jung-Hyuk;Kim, Sun-Kwang;Ryu, Un-Young;Min, Byung-Il;Kim, Ki-Hong;Rhim, Sung-Soo;Lee, Soon-Geul;Lee, Sang-Hoon
    • Journal of Acupuncture Research
    • /
    • v.23 no.6
    • /
    • pp.199-205
    • /
    • 2006
  • Objectives : The present study was conducted to evaluate the analgesic effects of automatically controlled heating acupuncture(ACHA) using 2 different pain models(acute pain and neuropathic pain) and 2 different stimulation conditions (heating $41.5^{\cdot}C$ and heating $44.5^{\cdot}C$) in Sprague-Dawley rats. Methods : Tail flick latency(TFL) to a noxious radiant heat stimulus in lightly anesthetized rats was measured before and after ACHA stimulation for 5-min at the Zusanli(ST36) acupoint. For the neuropathic surgery, the right superior caudal trunk was resected at the level between S1 and S2 spinal nerves innervating the tail. Two weeks after the nerve injury, ACHA stimulation($41.5^{\cdot}C$ or $44.5^{\cdot}C$) was delivered to Zusanli(ST36) for 5 min. The behavioral signs of warm allodynia were evaluated by the tail immersion test (i.e. immersing the tail in warm $water(40^{\cdot}C)$ and measuring the latency to an abrupt tail movement) before and after the ACHA stimulation. Results : In the TFL test, ACHA stimulations under both the conditions above produced more potent analgesic effects than plain acupuncture(PA, acupuncture needle insertion only) and control(no treatment). In the tail immersion test, ACHA stimulations under all of the conditions had markedly relieved the warm allodynia signs. Conclusion : Automatically controlled heating acupul1cture produced analgesic effecs in acute and neuropathic pains.

  • PDF

Compressive Behavior of Concrete with Loading and Heating (가열 및 재하에 의한 콘크리트의 압축거동)

  • Kim, Gyu-Yong;Jung, Sang-Hwa;Lee, Tae-Gyu;Kim, Young-Sun;Nam, Jeong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.119-125
    • /
    • 2010
  • The performance deformation of concrete can be caused by many factors such as load, thermal strain and creep at high temperature. Japan, Europe and America have been doing various experimental studies to solve these problems about thermal properties of concrete at high temperature, each study has generated different results due to a heating methods, heating hours, size of specimens and performance of a the loading, heating method, size of specimen and heating machine. There has been no unified experimental method so far. Therefore, this study reviewed experimental studies on the strength performance of concrete subject to heating and loading method. As a result, compressive strength of specimen prestressed increase in the temperature range of between $100^{\circ}C$ and about $400^{\circ}C$. Also, results can be analyzed as compare equation of compressive strength at elevated temperature with CEN and CEB code.

The Clinical Effects of Heating-conduction Acupuncture Therapy with General Acupuncture Therapy for Lateral Ligament Injury Induced by Ankle Sprain Grade II (전열침(傳熱鍼)과 일반 침의 병행치료가 발목 염좌로 인한 외측인대 2도 손상에 미치는 임상적 효과)

  • Jahng, Sun-Jeong;Jang, Hyo-Kil;Heo, Dong-Seok
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.21 no.4
    • /
    • pp.191-203
    • /
    • 2011
  • Objectives: The purpose of this study is to investigate the clinical effects of heating-conduction therapy on lateral ligament injury induced by ankle sprain grade II. Methods: The 67 outpatients who were diagnosed as ankle sprain grade II were performed heating-conduction acupuncture therapy on lateral ligament injury. To evaluate the efficiency of heating-conduction acupuncture therapy, pain threshold with pressure algometer and visual analogue scale(VAS) were applied pretreatment and after 1st, 2nd treatment. Results: 1. The pain threshold and VAS score after 1st and 2nd treatment with an isolated injury of the anterior talofibular ligament showed statistically significant improvement compared with pretreatment. 2. The VAS score after 1st and 2nd treatment with an combined injury to the anterior talofibular and the calcaneofibular ligament showed statistically significant improvement compared with pretreatment. 3. The VAS score after 1st and 2nd treatment with an combined injury to the anterior talofibular, calcaneofibular and posterior talofibular ligament showed statistically significant improvement compared with pretreatment. 4. After 1st and 2nd treatment on the posterior talofibular ligament and after 2nd treatment on the anterior taofibular and calcaneofibular ligament with an combined injury to the anterior talofibular, calcaneofibular and posterior talofibular ligament the pain threshold showed statistically significant improvement compared with pretreatment. 5. Between isolated injury and combined injury of lateral ligament, the difference in pain threshold and VAS score was not statistically significant. Conclusions: Heating-conduction acupuncture therapy has clinical effects of pain reduction on patient with an isolated injury and combined injury of lateral ligament induced by ankle sprain grade II.

The Clinical Effects of Heating-Conduction Acupuncture Therapy for Anterior Talofibular and Calcaneofibular Ligament Injury Induced by Acute Ankle Sprain (전열침(傳熱鍼)이 급성 족관절 염좌로 인한 전거비·종비 인대 손상에 미치는 임상적 효과)

  • An, Soon-Sun;Heo, Dong-Seok
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.3
    • /
    • pp.119-129
    • /
    • 2010
  • Objectives : The purpose of this study is to investigate the clinical effects of heating-conduction acupuncture therapy on ligament injury induced by acute ankle sprain. Methods : From september 16, 2008 to April 17, 2010, the 28 outpatients who had admitted to department of oriental rehabilitation medicine, Dae-Jeon oriental Medical hospital, Dae-Jeon university with acute ankle sprain were performed heating-conduction acupuncture therapy on anterior talofibular and calcaneofibular ligament injury. To evaluate the efficiency of heating-conduction acupuncture therapy, pain threshold with pressure algometer and visual analogue scale(VAS) were applied before treatment and after 1st, 2nd treatment. Results : 1. The pain threshold and the VAS score showed statistical significant improvement after 1st treatment on calcaneofibular and anterior talofibular ligament injury. 2. The VAS score after 2nd treatment on calcaneofibular and anterior talofibular ligament injury showed statistical significant improvement compared with that after 1st treatment. 3. The pain threshold after 2nd treatment on calcaneofibular and anterior talofibular ligament injury did not show statistical significant improvement compared with that after 1st treatment. 4. The difference between anterior talofibular and calcaneofibular ligament injury was not statistical significant in pain threshold and VAS score. Conclusions : Heating-conduction acupuncture therapy has clinical effects of pain reduction on patient with calcaneofibular ligament injury as well as anterior talofibular ligament induced by acute ankle sprain.

Study on the Changes of Ophthalmic Plastic Lens due to Heating (가열에 의한 플라스틱 렌즈의 변화 연구)

  • Cho, Hyun Gug;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.247-253
    • /
    • 2011
  • Purpose: The changes in properties of plastic lens due to heating was investigated. Methods: Plastic lenses of -2.00 diopter were heated at 60-100$^{\circ}C$, and then changes of refractive power, surface condition and transmittance were examined. Results: It was shown that the changes of lens surface due to heating happened at 70$^{\circ}C$ for 1h, 75$^{\circ}C$ for 10 min and 100$^{\circ}C$ 10 sec, respectively. More serious crack was occurred in high index lens and at higher heating temperature, respectively, and transmittance decreased depending on the extent of the damage on the surface of lens. Conclusions: Heating at temperatures above 70$^{\circ}C$ drives cracks on the surface of lens. Optician should recommend an appropriate lens considering the wearer's working conditions and guide for paying attention when they use eyeglasses.

Effect of Applying Pretreatment Methods before cooking for decreasing the Microbiological Hazard of Cooked Dried fish in Foodservice establishments (건어물을 이용한 조리음식의 미생물학적 위해 감소를 위한 조리 전처리 적용 효과)

  • 배현주;이재학;오세인
    • Korean journal of food and cookery science
    • /
    • v.19 no.5
    • /
    • pp.555-561
    • /
    • 2003
  • The purpose of this study was to analyze the microbiological hazards of dried fish (Jwieochae, Ojingeochae and Bugeochae), and to apply pretreatment methods to increase the safety of cooked dried fish within foodservice establishments. Microbiological inspections were conducted on Total Plate Count, Coliforms, E. coli, E. coli O157:H7, Staphylococcus aureus, Salmonella spp. and Listeria monocytogenes. The study results are summarized as follows. According to the Hazard analysis, there are many problems showing high numbers in terms of Total Plate Count and Coliforms, which were both well over acceptable standard levels. E. coli and Staphylococcus aureus were detected at certain foodservice establishments, while E. coli O157:H7, Salmonella spp. and Listeria monocytogenes were not detected at all. By applying various pretreatment methods, such as washing, blanching, pan frying and microwave heating, the levels of microbiological hazards were able to be controlled and lowered. Blanching was the most effective method, followed by panfrying, microwave heating and washing. The Total Plate Counts gradually decreased with increasing number of times washed and seconds panfried. From these results, it is concluded that to guarantee food safety, cooked dried fish raw materials should be kept hygienically and appropriate pretreatment methods applied before cooking.

Effect of Heating by Nano-Carbon Fiber Infrared Lamps on Growth and Vase Life of Cut Roses and Heating Cost (나노탄소섬유 적외선등 난방이 절화장미의 생육과 수명 및 난방비에 미치는 영향)

  • Lim, Mi-Young;Ko, Chung-Ho;Son, Moon-Sook;Lee, Sang-Bok;Kim, Gil-Ju;Kim, Byung-Soo;Kim, Young-Bok;Jeong, Byoung-Ryong
    • Journal of Bio-Environment Control
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • The greatest and major cost for cut rose production during winter seasons in Korea is cost of heating the greenhouse. A study was conducted on a cost-efficient heating system to reduce expenses of cut rose growers in times of high energy prices. An infrared heating system utilizing radiant energy has an obvious advantage over other heating methods in that the energy is first used to raise temperatures of plants and other objects and subsequently that of the atmosphere, resulting in faster reaching to desired plant temperatures at a reduced heating cost. In this study the heating effect and heating cost saving of a nano-carbon fiber infrared heating system (NCFIHS) installed in cut rose greenhouses in Gimhae, Gyeongnam Province were analyzed comparatively. In addition growth, quality, and vase life of 'Orange Fresh' roses grown in greenhouses heated by NCFIHS against those grown in greenhouses heated by so called an electrical heating system. In greenhouses with a NCFlHS with a set point air temperature of $20^{\circ}C$, plant temperature was maintained at $1{\sim}2^{\circ}C$ higher than the air temperature, and temperatures of growing bed surface and root zone were maintained at $17{\sim}19^{\circ}C$ throughout cold winter nights. The cost for heating in NCFIHS was about 25 and 51% of that of an electrical heating system and a hot water heating system heated by petroleum, respectively. Growth of roses harvested in greenhouses with a NCFIHS was similar to those grown in greenhouses with an electrical heating system. However, cut roses with more intense petal and leaf colors and a longer vase life (fresh weight and amount of water uptake) were harvested in greenhouses with a NCFIHS as compared to those harvested in greenhouses with an electrical heating system.

Energy Simulation for Conventional and Thermal-Load Controls in District Heating (지역난방의 일반제어 및 열량제어 에너지 시뮬레이션)

  • Lee, Sung-Wook;Hong, Hiki;Cho, Sung-Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.50-56
    • /
    • 2015
  • Korea district heating systems have mainly used setting temperature control and outdoor reset control. Different from such conventional normal methods, a thermal-load control proposed in Sweden can decrease the return temperature and reduce pump power consumptions because the control is able to provide the appropriate amount of required heat. In this study, further improved predictive optimal control in addition to the conventional controls were simulated in order to verify its effect in district heating system using TRNSYS 17. $200m^2$ apartment housing which accounts for 25% in Korea and is used as a calculation model;. the number of households in the simulation was 9. As a result, a higher temperature difference and decreasing flow rate at primary loop were shown when using thermal-load control.

The Optimal Design and Leakage Flux Analysis of the Induction Heating Cooker (유도가열조리기의 최적설계 및 누설자속 해석)

  • Byun, Jin-Kyu;Park, Il-Han;Choi, Kyung;Jung, Hyun-Kyo;Hahn, Song-Yop;Roh, Hee-Succ;Kwon, Kyoung-An;Yang, Woo-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.157-159
    • /
    • 1996
  • For the optimal design of the induction heating cooker, precise and accurate analysis of the magnetic field inside the jar must be achieved first. Until now, design methods based on experience has been used in industry field. But this takes a lot of trial and error, high cost and also long development time. So the analysis of the magnetic field distribution is very important. In this paper the magnetic field inside the induction heating cooker is analyzed by using axisymmetrical FEM(finite element method). And the method of the coil location design for the optimal heat source distribution using sensitivity analysis is developed. In addition, the shielding effect of the non-axisymmetrical 3-D ferrite structure used in induction heating cooker is also analyzed by the integral method.

  • PDF