• 제목/요약/키워드: Heating experiment

검색결과 869건 처리시간 0.032초

바닥난방시스템의 외기온도 변화특성을 고려한 운전방안에 관한 연구 (A Study on the Operational Strategies for Outdoor Air Temperature Change Characteristics in a Radiant Floor Heating System)

  • 안병천;송재엽
    • 설비공학논문집
    • /
    • 제25권12호
    • /
    • pp.685-692
    • /
    • 2013
  • In this study, the control characteristics and effects of heating control methods on the heating performance and energy consumption of a hot-water heating control system of a residential apartment were researched by simulation and experiment. The purpose of this study is to evaluate operational strategies for improving an indoor thermal environment and reducing f energy consumption in the radiant floor heating system of a residential apartment.

Electrical Transport and Joule Heating of ZrB2 Network in SiC Matrix

  • Kim, Jung-Hun;Kim, Chang-Yeoul;Choi, Sung-Churl
    • 한국세라믹학회지
    • /
    • 제55권5호
    • /
    • pp.440-445
    • /
    • 2018
  • To control the electrical properties of a SiC heating element, we sintered $SiC-ZrB_2$composites by using the spark plasma sintering method. The addition of $ZrB_2$ particles with lower electrical conductivity to the SiC matrices with comparatively higher electrical resistivity lowers the electrical resistivities of the composite material. The $ZrB_2$ particles aggregate to form large particles and 3-1, 3-2, and 3-3 networks, i.e., conduction paths. In our study, about $1-{\mu}m$-sized $ZrB_2$ powders start to form the conduction path at about 10 vol.% of addition, namely the threshold volume. The Joule heating experiment shows that 20 vol.% $ZrB_2$-added SiC heating element has outstanding heating efficiency.

광발열소재와 버블시트를 조합한 양생시트가 모르타르의 표면온도 이력에 미치는 영향 (Effect of Curing Sheet Conbined with Bubble Sheet and Heat generating Materias under Light Source on Surface Temperature of Cement Mortar)

  • 김수호;후윈야오;백성진;한준희;김종;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.160-161
    • /
    • 2022
  • This study is to investigate the temperature history over time of the cement mortar to confirm the bubble sheet insulation effect using the heat generat sheet. As a result of the experiment, it was confirmed that the heating effect was 6℃ higher on average than other types of sheets when the heating sheet is attached on the bottom of the double layered bubble sheet. For future research, it is planned to verify the heating performance by using the heating sheet under the same environmental conditions as the heating performance will be verified.

  • PDF

애구(艾灸)의 연소(燃燒) 시간(時間)에 대한 실험적(實驗的) 연구(硏究) -구간별(區間別) 발현(發現) 시점(時點)을 중심(中心)으로- (An Experimental Study of Moxa-Combustion Time by the Density of Moxa Material -On the point of time in the combustion stage-)

  • 박영배;강성길;고형균;오환섭
    • 대한한의학회지
    • /
    • 제15권2호
    • /
    • pp.241-252
    • /
    • 1994
  • It is known that the pattern of combustion temperature can be classified into preheating, heating. retaining and cooling periods. In this experiment. the authors have studied the heating mechanism by the density of moxa material during the heating and retaining periods. The starting point. the point at which it begins to reach the maximum gradient temperature. the ending point of the heating period. and the ending point of the retaining period were measured in order to get effective stmulation by repetition of moxa-combustion. For the experiment. samples of 300mg. 400mg, and 500mg of moxa material were molded into conical molds with each 10mm in diameter and height resulting in the volume of $0.26cm^3$. The following results were obtained: The $300mg/0.26cm^3$ denstiy sample reached al1 points tested faster than the samples of $400mg/0.26cm^3$ and $500mg/0.26cm^3$ It dose not reveal any statistical differences between $400mg/0.26cm^3$ and $500mg/0.26cm^3$ in the ending point. the point at which it begins to reach the maximum gradient temperature of the heating period or the ending point of the reataining period The only difference shown was in the starting point of the heating period. According to the above results. it is concluded that the lower density moxa material reached each point of the the respective period faster than the high density moxa material.

  • PDF

지역난방 적용 태양열시스템의 장기 열성능 분석 (Analysis of Long-term Thermal Performance of Solar Thermal System Connected to District Heating System)

  • 백남춘;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.167-173
    • /
    • 2007
  • This study analyzed by simulation using TRNSYS as well as by experiment on the solar district heating system installed for the first time for the district heating system in Bundang. Simulation analysis using TRNSYS focused on the thermal behavior and long-term thermal efficiency of solar system. Experiment carried out for the reliability of simulation system. This solar system where the circuits of two different collectors, flat plate and vacuum tube collector, are connected in series by a collector heat exchanger, and the collection characteristics of each circuit varies. Therefore, these differences must be considered for the system's control. This system uses variable flow rate control in order to obtain always setting temperature of hot water by solar system. Specifically, this is a system that heats returning district heating water (DHW) at approximately $60^{\circ}C$ using a solar collector without a storage tank, up to the setting temperature of approximately $85{\sim}95^{\circ}C$ To realize this, a flat plate collector and a vacuum tube collector are used as separate collector loops. The first heating is performed by a flat plate collector loop and the second by a vacuum tube collector loop. In a gross collector area basis, the mean system efficiency, for 4 years, of a flat plate collector is 33.4% and a vacuum tube collector is 41.2%. The yearly total collection energy is 2,342GJ and really collection energy per unit area ($m^2$) is 1.92GJ and 2.37GJ respectively for the flat plate vacuum tube collector. This result is very important on the share of each collector area in this type of solar district heating system.

열 차단 필름의 적용에 따른 냉난방 부하 분석에 관한 연구 (A Study on the Analysis of Heating and Cooling Load through Applying Window Film Insulation)

  • 김석현;조영흠
    • 한국태양에너지학회 논문집
    • /
    • 제33권6호
    • /
    • pp.47-53
    • /
    • 2013
  • In order to reduce the energy consumption of the building, much effort is being made. The problems are that excessive solar radiation in summer and the heat loss in winter by the increase of window area. To prevent this problems, government limited the window area ratio or the performance of windows in new buildings. In order to reduce energy consumption of the existing buildings, the window film insulation is spotlight because the window film insulation was simple to installation. This study confirmed the performance of the window film insulation and affect to heating & cooling load of buildings. The impact of the window film insulation coating was confirmed by experiment. And this study confirmed the annual heating & cooling load by simulation. As a results, the surface temperature of coated window was higher than the surface temperature of existing window. The window film insulation was increased surface temperature of window. And this study confirmed that the increased surface temperature was slightly affected the room air temperature through experiment of the insulation box. The results of the heating and cooling load by simulation, this study confirmed that the case of coated window film insulation decreased cooling load in summer and increased heating load in winter. Also the annual total heating & cooling load was increased a little in the case of coated the window film insulation.

전기자동차 충전기의 누전차단기 감도 전류 Trip 방지를 위한 Joule Heating 시뮬레이션 방안연구 (A Study on Joule Heating Simulation Method to Prevent Sensitivity Current Trip of Electric Vehicle Charger)

  • 이병국;어익수
    • 한국산학기술학회논문지
    • /
    • 제22권4호
    • /
    • pp.150-159
    • /
    • 2021
  • 본 논문에서는 충전 시 발생하는 누전차단기 Trip으로 충전 중단에 의한 전기자동차 사용자의 불편함을 방지하기 위한 것이다. 현장 사례연구로 충전기 고장(failure) 유형, 차종별 누설전류 측정실험, 누전차단기 동작 실험 시 여름철 충전기 내부 온도가 60 ℃이상까지 상승하여 누전차단기가 정격 감도 전류의 80%에서 Trip으로 충전 중단됨을 확인하였다. Joule Heating 모델링을 통하여 32A 전류를 초기 시간 t=0 (s)의 기준온도 30℃에서 통전하여 t=3000 (s)경과 후에는 누전차단기 충전부 주위에서 발열이 32.4℃까지 증가함을 시뮬레이션으로 확인하였으며, 통계 검증 tool을 활용하여 온도 및 시간(s) 요인이 발생 열량에 상관관계 0.97로 검증되었다. 본 논문의 연구 실험 결과는 충전기 기구 물 개발 시 충전케이스의 재질, 내부 배선의 배치, 유전 매질에 따른 Joule Heating 시뮬레이션 수행으로 여름철 충전기 내부 온도 상승에 의한 누전차단기 감도 전류 Trip을 방지할 수 있음을 알 수 있었다.

A NOVEL ZERO CURRENT SWITCHING HIGH FREQUENCY INVERTER FOR INDUCTION HEATING

  • Satoru, Shimajiri;Yoshihior, Hatanaka
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.1056-1061
    • /
    • 1998
  • In this paper, a novel zero current switching (ZCS) high frequency inverter for induction heating is proposed. The ZCS characteristics are investigated from both the numerical analysis and the experiment.

  • PDF

온도 민감 형광을 이용한 마이크로 스케일 표면온도 측정 (Surface Temperature Measurement in Microscale with Temperature Sensitive Fluorescence)

  • 정운섭;김성욱;김호영;유정열
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.153-160
    • /
    • 2006
  • A technique for measuring surface temperature field in micro scale is newly proposed, which uses temperature-sensitive fluorescent (TSF) dye coated on the surface and is easily implemented with a fluorescence microscope and a CCD camera. The TSF dye is chosen among mixtures of various chemical compositions including rhodamine B as the fluorescent dye to be most sensitive to temperature change. In order to examine the effectiveness of this temperature measurement technique, numerical analysis and experiment on transient conduction heat transfer for two different substrate materials, i. e., silicon and glass, are performed. In the experiment, to accurately measure the temperature with high resolution temperature calibration curves were obtained with very fine spatial units. The experimental results agree qualitatively well with the numerical data in the silicon and glass substrate cases so that the present temperature measurement method proves to be quite reliable. In addition, it is noteworthy that the glass substrate is more appropriate to be used as thermally-insulating locally-heating heater in micro thermal devices. This fact is identified in the temperature measuring experiment on the locally-heating heaters made on the wafer of silicon and glass substrates. Accordingly, this technique is capable of accurate and non-intrusive high-resolution measurement of temperature field in microscale.

Performance of a 2 Room Multi-Heat Pump with a Constant Speed Compressor

  • Kwan Young Chul;Kwon Jeong-Tae;Jeong Ji Hwan;Lee Sang Jae;Kim Dae Hun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.184-191
    • /
    • 2004
  • In order to improve the performance of a 2 room heat pump with a constant speed compressor, the optimum refrigeration circuit of the heat pump with different cooling and heating capacities is developed by applying capillary tubes. The refrigeration circuit is composed of four parts; a heating circuit, a cooling circuit, a by-pass circuit and a balance circuit. The performance of the 2 room heat pump are investigated from a rating experiment and a reliability experiment, using the calorimeter. Results of the rating experiment show that the capacity of heat pump is about $93\%$ of the design value. In particular, the capacity of the cooling single operation is about $13\%$ higher than the design value, and the capacity of the heating multi operation is about $5\%$ higher than the design value. From the reliability experi-ment, it is found that the lowest driving voltage of the compressor is about $75\%$ of the rating voltage. Also the compressor is reoperated normally under the flood back and the over load.