• 제목/요약/키워드: Heating block

검색결과 109건 처리시간 0.031초

후판의 곡면 가공을 위한 가변성형기술 적용 연구 (Study on Application of Flexible Forming Technology for Curved Plate Forming using Thick Plate)

  • 허성찬;서영호;박중원;이현민;구태완;강범수
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 추계학술대회 논문집
    • /
    • pp.122-125
    • /
    • 2008
  • Generally, in shipbuilding, large curved block components which have large curvature radius along various directions are used for huge ships such as LPG-vessel and oil tanker ships. Lots of the blocks are manufactured by line heating method which uses a heat source to bend the thick plate materials. The conventional forming process is entirely dependent on the experience of experts because it is done by manual method thus the curvatures and qualities are not uniform even for same part. However, it is hard to adopt the press forming process using die tool sets fur the manufacturing because of the characteristics of the industry that based on the small quantity and variety in the products. In this study, flexible forming technology using numbers of punches is investigated based on the simulation to substitute for the conventional forming method. Thick plate material model was applied to the proposed process to verify the feasibility for hull structure block forming process. The press forming processes were simulated by adopting the explicit-to-implicit sequential solution. Moreover, experiment of the flexible forming process was also conducted and its results were compared with that of simulation.

  • PDF

마이크로다공성 코팅된 인접 복수 발열체에 대한 PF5060의 냉각 특성 (Characteristics of Cooling for the Adjacent Double Micro-Porous Coated Surfaces in PE5060)

  • 김태균;김윤호;이규정
    • 대한기계학회논문집B
    • /
    • 제30권7호
    • /
    • pp.646-655
    • /
    • 2006
  • The present research is an experimental study on characteristics of cooling behavior for the adjacent copper blocks with surface roughness or micro-porous coated surface. The experiments were carried out at saturation state or within subcooled states of PF5060. The effects of heater orientation and the intervals between heating surfaces or substrates were investigated under various heat flux conditions. The boiling performance of copper block with micro-porous coated surface was better than that of copper block with surface roughness. It is understood that the bubble sweeping enhances boiling performance for the heaters with inclinations of $\theta=45^{\circ}\;and\;\theta=90^{\circ}$, where as the bubble flattening decreases boiling performance for the heaters with inclinations of $\theta=135^{\circ}\;and\;\theta=180^{\circ}$. In comparison to upper heater and below heater with orientation, the upper heater has lower superheat temperature than the below heater due to the bubble sweeping. It is also found that boiling performance decreases in the case of adjacent double heaters with only 0.2cm substrate interval.

A Study on Remaining Efficiency of Thermal Straightening after Block Lifting

  • Ha, Yunsok;Yi, Myungsu
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제1권3호
    • /
    • pp.148-156
    • /
    • 2015
  • Deck plates of ships or offshore structures would make out-of-plane distortion for their thin thickness. These distortions are usually straightened by thermal straightening such as flame heating method. After thermal straightening, the blocks are lifted and moved by cranes to assemble it at dry-dock stage. After this lifting process, out-of-plane deformation again happens frequently. And then, they continuously cause quality and accuracy problems in the final dry-dock process. So, it takes more time for repair and correction working. According to preceding research, the lifting process by cranes would offset the effect on thermal straightening. The target of this study is to develop a methodology analyzing the remaining efficiency of thermal straightening after block lifting. The development was based on the assumption of yield state at straightening region. Therefore the remaining efficiency was obtained by different stiffness slope while lifting & relieving. The efficiency formula was designed using inherent strain, and we made a table of zero-efficiency by cooling speed and class rule's steels. As a result, if the stress orthogonal to straightened line is calculated during lifting analysis by FEA, the efficiency can be obtained linearly to the values in the table. Finally, even optimized carling position can be designed by considering the regional data from series project and welding region on deck.

고분자 P123와 란탄이 도핑된 알루미나의 특성 연구 (Characterization of Alumina Doped with Lanthanum and Pluronic P123 via Sol-Gel Process)

  • 정미원;이미회
    • 한국세라믹학회지
    • /
    • 제45권5호
    • /
    • pp.297-302
    • /
    • 2008
  • To direct the evolution of nanostructure and immobilize ${\gamma}-Al_2O_3$ catalyst, nanocrystalline La-doped-$Al_2O_3$ powder were prepared by the sol-gel process with addition of an amphiphilic block copolymer template (pluronic P123: $(poly(ethyleneoxide)_{20}-poly(propyleneoxide)_{70}-poly(ethyleneoxide)_{20})$. The dried gel is amorphous, whereas heating at temperature above $700^{\circ}C$ leads to the formation of nanocrystalline ${\gamma}$ and ${\delta}-Al_2O_3$ and these two phases is kept until $1100^{\circ}C$. ${\alpha}-A1_2O_3 $starts to form at $1200^{\circ}C$ with $LaAl_{11}O_{18}$. The surface morphology and crystal structure has been observed by field emission scanning electron microscope (FE-SEM) and X-ray diffraction (XRD). Solid state $^{27}Al$ MAS NMR indicates two types of local environment, i.e. octahedral and tetrahedral sites. The surface area and pore size was compared among these powders using the BET nitrogen adsorption measurements.

An Experimental Study on the Thermal Performance of a Concentric Annular Heat Pipe

  • Boo Joon Hong;Park Soo Yong;Kim Do Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • 제19권4호
    • /
    • pp.1036-1043
    • /
    • 2005
  • Concentric annular heat pipes (CAHP) were fabricated and tested to investigate their thermal characteristics. The CAHPs were 25.4 mm in outer diameter and 200 mm in length. The inner surface of the heat pipes was covered with screen mesh wicks and they were connected by four bridge wicks to provide liquid return path. Three different heat pipes were fabricated to observe the effect of change in diameter ratios between 2.31 and 4.23 while using the same outer tube dimensions. The major concern of this study was the transient response as well as isothermal characteristics of the heat pipe outer surface, considering the application as uniform heating device. A better performance was achieved as the diameter ratio increased. For the thermal load of 180 W, the maximum temperature difference on the outer surface in the axial direction of CAHP was $2.3^{\circ}C$ while that of the copper block of the same outer dimension was $5.9^{\circ}C.$ The minimum thermal resistance of the CAHP was measured to be $0.004^{\circ}C/W.$ In regard to the transient response during start-up, the heat pipe showed almost no time lag to the heat source, while the copper block of the same outer dimensions exhibited about 25 min time lag.

Zig-Zag 결선 및 Open-Delta 방식을 이용한 새로운 고조파 저감장치의 개발 (Development of the New Hormonic Eliminating Device Using Zig-Zag Connection and Open-Delta Mode)

  • 이성호;김기성;유상봉
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.169-174
    • /
    • 2005
  • 지금까지의 고조파 필터는 중성선 리액터와 지그재그결선의 영상 고조파 전류를 제거하였으나, 부하율에 따라 고조파 저감율이 변하여 경부하에서는 고조파 저감율이 낮아지는 특성이 있고, 중성선 리액터 과열로 중성선 단선 위험의 문제가 발생하였다. 본 Zig-Zag 결선 및 Open Delta 방식을 이용한 새로운 고조파 저감장치(HANOS)는 Zig-Zag 결선의 Core Block내에 추가로 Open Delta 방식을 결선하여 중성선에 연결함으로써 중성선에 흐르는 영상 고조파 전류가 과열 없이 안전하게 제거되는 것을 시험 분석한 결과로 증명하였다.

강릉지역 전(田)자형 민가의 주생활 변화에 따른 주거공간의 변형 (The Residential Space Transformation of Vernacular Houses with 田-shaped Floor Plan according to the Housing Life Change at Gangreung Area)

  • 최장순
    • 한국농촌건축학회논문집
    • /
    • 제20권2호
    • /
    • pp.49-56
    • /
    • 2018
  • The vernacular houses with 田-shaped floor plan at Gangreung have been played important roles in tracing the vernacular living cultures including housing life. But due to the adoption of convenient facilities in vernacular housing lives caused by modernization and urbanization, many changes and transformations have happened at residential space of vernacular houses. This thesis targets to extract basic data to prepare and prevent various problems in process of renovation, extension and function change as installing housing life facilities, and to identify the changes and transformations of them to prepare the proper balances between their original form preservation and residents' convenience living. The results are as follows. The inner wall removal of rooms, the fuel change of cooking and heating, the leveling change of kitchen floor made possible the sedentary lifestyles. And its residential rooms were transformed from two row to one row by inner wall removal, the fuel heating change, the heating method change and the heat insulating materials. The residential extension materials were changed from the traditional materials such as soil, wood, etc to the modern materials such as cement block or brick, sandwich panel, etc. And the modern materials were used and attached to widen residential spaces to the vernacular house because of the easiness of execution. So, it is necessary for 田-shaped floor plan vernacular house owners to distribute printed execution guide book to prevent and minimize the various problems to be shown by extension, renovation and function change.

Determination of MTBE, TBA and BTEX in Soil by Headspace Gas Chromatography-Mass Spectrometry

  • Shin, Ho-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권5호
    • /
    • pp.1693-1698
    • /
    • 2012
  • A headspace gas chromatographic mass spectrometric (GC-MS) assay method was developed for the simultaneous determination of methyl tertiary butyl ether (MTBE), $tert$-butyl alcohol (TBA) and benzene, toluene, ethyl benzene and xylene (BTEX) in soil contaminated with gasoline. 2 g of soil sample were placed in a 10 mL headspace vial filled with 5 mL of phosphoric acid solution (pH 3) saturated with NaCl, and the solution was spiked with fluorobenzene as an internal standard and sealed with a cap. The vial was heated in a heating block for 40 min at $80^{\circ}C$. The detection limits of the assay were 0.08-0.12 ${\mu}g$/kg for the analytes. For five independent determinations at 10 and 50 ${\mu}g$/kg, the relative standard deviations were less than 10%. The method was used to analyze fifty six soil samples collected from various regions contaminated with gasoline in Korea. The developed method may be valuable for the monitoring of the analytes in soil.

고농도 Out Gas 정량 분석법 개발

  • 김민주;김종윤;정기호;박창식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.13-13
    • /
    • 2009
  • 본 연구는 MLCC 구성성분의 증발/비등에 의한 저분자물질의 제거가 bar 수축에 미치는 영향도를 평가하기 위해, 압착 bar에서 발생하는 고농도의 out gas를 정량하기 위한 최적 system을 구축하고자 하였다. gas 포집에 범용적으로 사용하는 Purge & Trap sampler 대신 Heating block를 사용하여 gas를 발생시키고 동시에 solvent에 용해시킴으로써 고농도의 시료가 희석될 수 있는 전처리 장치를 디자인하였다. 그 결과 고농도 gas 주입에 의한 장비오염과 peak saturation 문제가 해결되었고, gas phase의 시료를 liquid phase로 상전이 시켜 autosampler를 이용한 정확한 량의 시료 주입이 가능하였다. System의 Gage Linearity와 Bias는 각각 1.7%와 1.3%로 개선이 필요없는 수준의 정확도를 가졌다.

  • PDF

Engineering-scale Test for Validating the T-H-M Behavior of a HLW Repository: Experimental Set-up

  • Lee, Jae-Owan;Baik, Min-Hoon;Cho, Won-Jin
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.194-198
    • /
    • 2004
  • The thermo-hydro-mechanical (T-H-M) process is one of major issues in the performance assessment of a high level waste (HLW) repository. An engineering-scale test was planned and its experimental set-up has being installed, to validate the T-H-M behavior in the buffer of a reference disposal system. The experimental set-up consists of 4 major components: the confining cylinder with its hydration water tank, the bentonite block, the heating system, and the sensors and instruments. The monitoring and data acquisition system is employed to control the heater to maintain the temperature of $95^{\circ}C$ at the interface of the heater and bentonite blocks and to collect signals from sensors and instruments installed in the bentonite blocks.

  • PDF