• Title/Summary/Keyword: Heating Zone

Search Result 301, Processing Time 0.023 seconds

Spot Heating Technology Development for Strawberry Cultivated in a Greenhouse by Using Hot Water Pipe (온수배관을 이용한 시설딸기 부분난방기술 개발)

  • Moon, Jongpil;Kang, Geum-Choon;Kwon, Jin-Kyung;Paek, Yee;Lee, Tae Seok;Oh, Sung-Sik;Nam, Myeong-Hyeon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.5
    • /
    • pp.71-79
    • /
    • 2016
  • The effects of spot heating for growing the strawberry cultivated in a plastic greenhouse during the winter that were estimated in Nonsan strawberry experiment station located in Chungnam. The temperature of water for heating was controlled by a electric hot water boiler and kept at the range of $22{\sim}24^{\circ}C$. Heating pipes were set up in root zone for root zone heating and very close to crown for crown heating. Spot heating effects were estimated by applying spot heating system in three test factors of heating root zone, crown only and crown plus root zone. The material for crown heating pipe was white low density polyethylene and the nominal diameter of that pipe was 16 mm. The material for root zone heating pipe was flexible stainless steel and the nominal diameter of that pipe was 15A. The flow rate of heating water circulation was 480 L/h and water circulation lasted for all day long. Temperatures, harvest yield by test beds were surveyed from Nov. 10, 2013 to Apr. 29, 2014. The temperature of crown spot for crown heating bed was at the range of $13.0{\sim}17.0^{\circ}C$ during the night and that of crown spot in control bed was at the range of $8.0{\sim}14.0^{\circ}C$. Also, the temperature of root zone for root zone heating bed was at the range of $18{\sim}21.0^{\circ}C$ and that of root zone in control bed was at the range of $13.0{\sim}15.0^{\circ}C$. The cumulative yield growth rate in earlier harvest period (from Dec. 20 to Mar. 15) of crown heating bed was 43% compared with that of control bed and the cumulative yield of crown plus root zone heating bed was 39 % and that of root zone heating bed was 39 %.

Analysis of Heating Energy in a Korean-Style Apartment Building 3 : The Effect of Room Condition Settings (한국형 아파트의 난방에너지 분석 3 :실내설정조건의 영향)

  • Park, Yoo-Won;Yoo, Ho-Seon;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.722-728
    • /
    • 2005
  • The present paper deals with heating energy estimation in Korean-style apartments, paying special attention to the effect of room condition settings. Two types of heating modes are considered: continuous single-zone and scheduled multi-zone. In the latter, zones during unoccupied periods remain unconditioned. Also analyzed are sensitivities in heating energy with respect to the air change rate and the set temperature. The energy use is estimated with TRNSYS 15, a dynamic load calculation program. Heating energy for the actual residential condition (1.0 ACH and $24^{\circ}C$) appears to be nearly the same as that for a typical design standard (1.5 ACH and $20^{\circ}C$). The air change rate affects heating energy as sensitive]y as the set temperature. For all the simulated cases, the scheduled multi-zone heating mode is more energy-efficient than the continuous single-zone. Heating energy depends appreciably on the shading factor. It is expected that considerable heating energy for apartment houses can be saved by employing a multi-zone mode along with appropriate control devices.

The Effect of Feeding Characteristics on the Temperature Distribution of Rotary Kiln (로타리 킬른의 장입 특성이 온도분포에 미치는 영향)

  • Park, Jong-Seok;Chun, Chul-Kyun
    • Journal of the Korean Society of Combustion
    • /
    • v.12 no.3
    • /
    • pp.24-32
    • /
    • 2007
  • A theoretical model was developed for rotary kiln and computational study was conducted to find the effect of feeding characteristics. One dimensional model with the variations of heating distribution, length of heating zone, excess air ratio and revolution was considered. The comparison of parallel-flow rotary kiln with that of counter-flow was conducted. For parallel-flow type, it is found that the variation of temperature of solid is not great for the zone that is following flame-heating zone. This zone is good to take the special treatment because thermal deviation is small and contacting time is enough for another treatment. Increase of excess air ratio have the effect of decreasing solid temperature. But this effect of decreasing solid temperature goes small for the great excess air ratio. The heating is efficient for the flame which has the maximum heating at the central region of the full length.

  • PDF

Characteristics of Electric Resistance Dual Spot Welding Process of AZ31 Magnesium Alloy Sheets (AZ31 마그네슘 합금 판재의 전기저항 이중 스폿용접 특성)

  • Sun, Xiao-Guang;Jin, In-Tai
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.3
    • /
    • pp.1-11
    • /
    • 2022
  • In this study, an electric resistance dual-spot welding process using a copper electrode inserted in a heating electrode is suggested for the spot welding of AZ31 magnesium sheets. This spot-welding process involves two heating methods for welding at the interfacial zone between the magnesium sheets, one of which is the heating method by thermal conduction from the heating electrode heated by the welding current induced to the steel electrode, and the other heating method uses the electric resistance between the contacted surfaces of the two sheets by the welding current induced to the copper electrode. This welding process includes the welding variables, such as the current induced in the heating electrode and the copper electrode, and the outer diameters of the heating electrode. This is because the heat conducted from the heating electrode can be maintained at a higher temperature in the welding zone, which has a slow cooling effect on the nugget of the melted metal after the welding step. The pressure exerted during the pressing of the magnesium sheets by the heating electrode can be increased around the nugget zone at the spot-welding zone. Thus, it not only reduces the warping effect of the elastoplastic deformation of sheets, but also the corona bond can make it less prone to cracking at the welded zone, thereby reducing the number of nuggets expelled out of the corona bond. In conclusion, it was known that an electric resistance dual spot welding process using the copper electrode inserted in the heating electrode can improve the welding properties in the electric resistance spot welding process of AZ31 magnesium sheets.

Growth and Yield of Hydroponic Rose "Little Marble" as Affected by Root Zone Temperature and Heating Method in Winter Season (동계 근권 온도 및 가온방법이 양액재배 장미 "리틀마블"의 생육과 수량에 미치는 영향)

  • Lee, Mi-Young;Hwang, Seung-Jae;Jeong, Byung-Ryong
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.39-40
    • /
    • 2001
  • This experiment was conducted to investigate the effect of root zone heating on the growth of cut minirose Rosa hybrida L. ′Little Marble′ in winter season. Effects of four different root zone temperatures of 16, 20, 24$^{\circ}C$ and non-heating control on the growth and productivity were compared. Harvested cut-flowers were measured for stem length, stem diameter, fresh and dry weights, numbers of leaves, stems and flowers, days to flower, and chlorophyll concentration. The results showed that mean height was the greatest at 16$^{\circ}C$. Days to flower was the shortest at 24$^{\circ}C$. Fresh and dry weights of top (shoot+leaf+flower), shoot and leaf were the greatest at 2$0^{\circ}C$. Stem and flower numbers were the greatest at 16$^{\circ}C$, but leaf number was the greatest at 2$0^{\circ}C$. Mean cut flower yield was the greatest at 16$^{\circ}C$. Chlorophyll concentration was slightly higher at 16$^{\circ}C$, but was not significantly different among the treatments. Stem diameter was the greatest at 2$0^{\circ}C$. Dry matter was the greatest at 24$^{\circ}C$. Total yield of cut rose stems increased with increasing temperature. Combined heating could save 24% in fuel cost as compared to the air heating alone. The results obtained suggested that optimal root zone temperature for the growth of cut rose "Little Marble" was 2$0^{\circ}C$, and the greenhouse heating energy can be saved by minimal air heating combined with root zone heating to 2$0^{\circ}C$.

  • PDF

A Study on an Optimal Design of Electric Snow Melting Mat for Vulnerable Walk Zone (제설기반 취약지역 보행자의 전기안전발판(융설용) 최적설계에 관한 연구)

  • Kwon, Jin Wook;Jang, Chul;Hwang, Myung Whan
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.12-18
    • /
    • 2016
  • This paper describes an optimal design of electric snow melting mat on vulnerable walk zone. In order to design an optimal electric power of snow melting mat and protect pedestrians with a nonslip mat, with considering protection of environmental pollution from abusing of the de-icing salts added calcium chloride. We analyzed nine snow melting mats through verification experiment in the condition of $-5^{\circ}C$, depending on three different kinds of heating material, electric heating cable, carbon heating film and carbon textile film. As a consequence, the $150W/m^2$ carbon textile film mat for snow melting was identified as an optimal power input and functional performance for pedestrians' safety on vulnerable walk zone. It is expected that the $150W/m^2$ carbon textile film mat would be useful to reduce slip down accidents by human error.

Development and Evaluation of the Upper & Lower side Ondol System in Apartment Houses (공동주택의 윗목/아랫목 온돌 제어시스템 개발 및 평가)

  • Cho, D.W.;Yu, K.H.;Yu, J.Y.;Jung, H.K.;Kim, Y.H.;Kim, S.H.;U., M.;Yang, I.H.
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.627-636
    • /
    • 2008
  • The purpose of this study is to develop the new korean district heating system for apartment houses. The upper & lower side ondol system with multi sensing control system was developed as a new korean district heating system and evaluated in 2 mock-up laboratories last winter. As a result of field measurement, when the load differences between perimeter zone and central zone are increased, the ondol system divided in the upper and lower side can be evaluated as the new ondol system with a capability for suppling proper heating energy for each zone. The user can have the freedom for changing an upper zone and a lower zone and controlling each temperature according to their needs.

  • PDF

Coarsening Behavior of Fine Precipitates in Rapidly Quenched Al-Fe Based Alloy Ribbons by In-situ Heat Treatment (급랭응고한 Al-Fe 합금계 리본을 고온에 노출시킴에 따른 미세석출물의 성장거동)

  • Baik, Nam-Ik
    • Journal of Korea Foundry Society
    • /
    • v.15 no.3
    • /
    • pp.252-261
    • /
    • 1995
  • The purposes of this study were to investigate the microstructural changes in alloy ribbons of Al-Fe-Mo-Si quarternary system at $450{\sim}500^{\circ}C$, and to study the coarsening mechanism of fine precipitates. Using the hot stage in TEM, in situ microstructural changes in Al-4Fe-0.5Mo-1.5Si alloy ribbon and Al-8Fe-2Mo-1.5Si alloy ribbon have been examined successively up to 60 hours at $450^{\circ}C$ and $500^{\circ}C$. Cell structure in zone B of Al-4Fe-0.5Mo-1.5Si alloy ribbon was observed to collapse even in 10 minutes by in-situ heating at $450^{\circ}C$ and the size of precipitates in zone B increased twice in 60 hours. The precipitates in zone A of Al-4Fe-0.5Mo-1.5Si alloy ribbon showed slower coarsening rate than those in zone B by in-situ heating at $450^{\circ}C$. The precipitates in zone A of Al-8Fe-2Mo-1.5Si alloy ribbon increased 50% by in-situ heating at $500^{\circ}C$ in 50 hours compared to the initial precipitates while any microstructual change in zone B was not observed by in-situ heating at $500^{\circ}C$ up to 50 hours. Only the precipitates in zone A of Al-4Fe-0.5Mo-1.5Si alloy ribbon satisfied $r^3{\propto}t$ relationship of coarsening mechanism.

  • PDF

A study on mechanical properties of friction weld interface in metal bearing (Metal Bearing 마찰용접면의 기계적 성질에 관한 연구)

  • 오세욱;이영호;민택기
    • Journal of Welding and Joining
    • /
    • v.8 no.4
    • /
    • pp.20-26
    • /
    • 1990
  • In this study, to make research on its optimum condition in friction weld when the heating pressure is change during 1.6 to 3.0 $kgf/mm^2$, the experiment was performed with metal bearing under various condition; 1600 r.p.m spindile speed, 0.6 $kgf/mm^2$ preheating pressure, upset pressure 2.6 $kgf/mm^2$, 0.5 seconds preheating time, 1.7 seconds heating time, water and air was ejected 6 $kgf/mm^2$ into the bushing. On the basis of the experimental results, the following conclusion are drawn; 1) At the area of weld interface, the heardness is shown the maximum value and heat-affected zone about 0.5mm both sides. 2) Bending strength is shown the optimum heating pressure 2.4 kgf/mm. 3) With the approach of the flash, Sn is increased only 2 mm in A-alloy structure.

  • PDF

A study for detection of melt flow zone about polyethylene butt fusion joints (폴리에틸렌 배관 버트융착부 열용융거리 측정에 대한 연구)

  • Kil, Seonghee;Kim, Younggu;Jo, NYoungdo;Lee, Yeonjae
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2016
  • Polyethylene pipes has useful benefits which are anti-corrosive and flexible material, so it is used to gas pipes but also class 3 water pipes of nuclear power plant, process pipes of petrochemical plant and chemical plant. So the usage of polyethylene pipes is widely increased. But it has been limited for the usage of polyethylene, because it can not be directly detected to fusion joints by using non destructive evaluation. Polyethylene pipes are connected by two methods, one is butt fusion and the other is electrofusion. Butt fusion is widely used to connecting the pipes. It is proposed to method for determining the reliability of joints in this study that is detection of the melt flow zone at fusion joints. In this study, middle density polyethylene is used, outside diameter of the test specimen is 225mm and thickness is 20.5mm. Speed of ultrasonic of this test specimen is 2,200m/s. Test specimens were fabricated by varying the heating time which means from 0% to 130% applying time through heating plate to polyethylene for detecting melt flow zone. Also 4 additional test specimens were made, one was made that not scrapping attached surface of pipes but applying 100% of the proper heating time and the others were made to include of soil, gravel and vinly tape paper at fusion joints, that were also applied 100% of proper heating time. Ultrasonic testing to measure the melt flow zone of 20 test specimens was conducted by using 3.5MHz and 5.0MHz ultrasonic probes and melt flow zone measuring was conducted to three times at different point to one specimen. To differentiate the melt flow zone signal, post image processing was equally conducted to all test results and image levels, contrast, sharpen, threshold were adopted to all teat results and the test results were displayed gray scale. From the results, for the shorter heating times the reflection area of multiple echo have been increased, so the data was obtained from the position where it can be eliminated as much as possible. At 80% of proper heating time(168 sec.), the signal of melt flow zone was obtained clearly, so measuring could be conducted. From 7% of proper heating time(15 sec.) to shorter heating times. we could not obtain the signal because test specimen was not fused. From the result, we can verify that measuring of melt flow zone by using phased array ultrasonic imaging method is possible. And we can verify to complete and incomplete butt fusion by measuring the melt flow zone.