• Title/Summary/Keyword: Heating Unit

검색결과 495건 처리시간 0.032초

YSZ/Ni-Cr 저항 발열 복합용사피막의 특성 (Characteristics of plasma sprayed composite YSZ/Ni-Cr resistant heating coatings)

  • 김병수;박경채;김태형;양병모
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2003년도 춘계학술발표대회 개요집
    • /
    • pp.111-113
    • /
    • 2003
  • The existing heating unit is indirect-heating method that make use or the nichrome wire or halogen lamp. The indirect-heating method has the demerits of long warming time, high power consumption and many organization parts. In this study, the heating unit of direct-heating method manufactured as being the thermal spray coating of conductive heating material on the surface of heating unit in order to improve the demerits of indirect-heating method. And YSZ added Ni-20Cr that had moderate electrical resistivity was chosen of the conductive heating material.

  • PDF

공동주택 단위난방부하 계산을 위한 단위동법 제안 (Proposal of Unit Building Method for Calculating Unit Heating Load of Apartment Houses)

  • 유호선;정주혁;문정환;이재헌
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.68-76
    • /
    • 2007
  • As an alternative approach to evaluate the unit heating load for apartment houses, we newly developed and proposed unit building method. The new method, which calculates the heating load of an apartment building as a whole, conceptually corresponds to integral analysis of building heat loss, while the existing unit apartment method to differential analysis. Four typical building models of Korean-style apartment house and two dynamic load calculation programs were selected to validate the present method under realistically imposed conditions. Eight sets of unit heating load calculated respectively by unit building and unit apartment methods showed excellent agreements regardless of building model and simulation program. It is expected that the unit building method can take the place of the unit apartment method due to fewer modeling assumptions as well as less computational efforts. Additional calculations to investigate the effects of various parameters on unit heating load yield good consistencies with known facts, and re-confirm the validity.

임대아파트 난방방식별 에너지소비와 만족도 조사에 관한 연구 (A Study on the Energy Consumption and the Degree of Satisfaction by Heating System in Rental Apartment)

  • 박민용;장승재
    • 한국주거학회논문집
    • /
    • 제14권3호
    • /
    • pp.85-92
    • /
    • 2003
  • Considering the present development situation of rental apartment since 1982, the supply of homeless housing for low-income dwellers has contributed a amount of quantities, but has been deficient qualities in housing policy. To propose the energy policy for low-income dwellers, this study investigated the energy consumption and the degree of heating satisfaction by heating system through questionaries in permanent rental apartment and 50 year period rental apartment complexes. The results of this study were as follows; The annual energy consumption of heating and hot water supply is 267.2 Mca1/$\textrm{m}^2$ㆍyr in central heating system, is 163.9 Mca1/$\textrm{m}^2$ㆍyr in unit heating system. But from the view of annual energy cost and the degree of heating satisfaction, central heating system were better than unit heating system in rental apartment.

수송용 DPH HVAC 히팅유니트장치의 열유동 시뮤레이션평가연구 (A Study on the Heat Transfer Characteristics of Heating Unit in DPH HVAC)

  • 노홍구;임경빈;노종호;이영기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.605-610
    • /
    • 2008
  • The study aims to analyzed and identify the heat transfer characteristics of heating unit for room using 3-D numerical-analysis in order to design heating unit. The temperature comparison processes were done with various numerical conditions. In addition, the optimal conditions of heating unit design were proposed as inlet temperature, the inlet flow, heater power, and vessel size.

  • PDF

기능성 모듈이 적용된 천장 매립식 냉난방 유닛의 유동특성 평가에 관한 연구 (A Study on the Evaluation of Flow Characteristics of Heating and Cooling Unit Installed within Ceiling with Functional Modules)

  • 이홍철;황인주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1131-1136
    • /
    • 2006
  • In this study, an experimental and numerical analysis on the flow characteristics of heating and cooling unit installed within ceiling with functional modules was carried out. And the flow characteristics of the heating and cooling unit was investigated with the main parameters such as each filter and inside structure. The experimental results show the possibility of medium filter application. And the numerical results show that the effect of improved inside structure of heating-cooling and air-conditioning unit on flow distribution.

  • PDF

한국형 아파트의 난방에너지 분석 2: 난방방식에 따른 차이 (Analysis of Heating Energy in a Korean-Style Apartment Building 2: The Difference according to Heating Type)

  • 이봉진;정동열;이선;홍희기
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.459-466
    • /
    • 2004
  • In order to save the energy in apartment houses, it is essential that the energy amount consumed in heating per household should be surveyed and analyzed according to heating method, which can be classified into unit, central and district methods. As a basis, we selected the household with nominal area of 32 py. because it accounts for the most percentage in Korea. It is estimated that the gas amount for cooking is 90 ㎥ and the energy amount for hot water supply is 11.41 GJ for a year, which is necessary to calculate the heating energy. Through the survey of actual energy consumption in Seoul and Gyeonggi, the energy amount used in heating can be obtained according to the heating type: 26.02 GJ/year for the unit heating, 28.09 GJ/year for the central heating and 40.61 GJ/year for the district heating.

PCM 유닛을 적용한 공기 열원 히트펌프의 연속난방 성능 특성에 관한 실험적 연구 (An Experimental Study on the Heat Transfer Performance of an Air-Source Heat Pump Using a PCM Unit for Continuous Heating)

  • 장민;정동일;정종호;김용찬
    • 설비공학논문집
    • /
    • 제27권10호
    • /
    • pp.537-543
    • /
    • 2015
  • Air-source heat pumps are widely used in winter as heating units due to their higher efficiency compared to electronic heaters or gas fired equipment. However, the air-source heat pump can cause discomfort during periodic defrosting operations. In this study, a PCM unit for continuous heating was adopted to solve this problem. The PCM unit consisted of a PCM, a heat exchanger, and control valves. It was installed between the outdoor and indoor units. The performance of the proposed system was measured during both defrosting and heating operations. The indoor unit showed an average leaving temperature of $26^{\circ}C$ after adopting the PCM unit for continuous heating during the defrosting operation.

가열 롤에서 플라즈마 TiO2-NiCr 용사피막의 특성 (Characteristics of Plasma Sprayed TiO2-NiCr Conductive Heating Roll Coatings)

  • 강태구;진민석;고영봉;김태형;조상흠;박정식;김종철;박경채
    • Journal of Welding and Joining
    • /
    • 제25권4호
    • /
    • pp.28-34
    • /
    • 2007
  • The heating unit of direct heating method manufactured as the plasma spray coating of $TiO_2/NiCr$ conductive heating material on the surface of heating unit in order to improve the disadvantages of indirect heating method. $TiO_2$ and NiCr (80wt.%Ni-20wt.%Cr) that had the properties of conduction and heating was chosen for the conductive heating material. The compositions of the composite powders were studied $TiO_2-30wt.%NiCr\;and\;TiO_2-10wt.%NiCr$. As the heating temperature was increased, the hardness of heating layer was increased because of the fine microstructure and the decrease of porosity. The adhesion strength was decreased for coarsening and connection of voids in the insulation layer, and the electrical resistivity of heating layer was increased for fine crack formation and growth. In this study, the best efficient sprayed coatings with heating unit was concluded as the plasma sprayed $TiO_2-10wt.%NiCr$ coatings that was heat treated at $300^{\circ}C$.

냉방주체 운전모드에서 동시냉난방 열펌프 성능향상에 관한 실험적 연구 (Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Cooling-main Operating Mode)

  • 정현준;주영주;강훈;김용찬;최종민
    • 설비공학논문집
    • /
    • 제20권5호
    • /
    • pp.314-320
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the improved wall insulation. Hence, a multi~heat pump is required to cover heating and cooling simultaneously for each indoor unit. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the cooling-main operating mode were investigated experimentally. The system adopted a variable speed compressor using R410A with four indoor units and one outdoor unit. In the cooling-main mode, the heating capacity decreased due to reduction of flow rate to the indoor unit under heating mode operation. The EEV opening was adjusted to increase flow rate to the indoor unit under heating mode operation. The total capacity and COP in the cooling-main mode increased by 20.5% and 29.2%, respectively, compared with those in the cooling-only mode.

주거용 건물의 난방 방식별 열적성능 및 실내환경 특성 평가를 위한 실험적 연구 (An Experimental Study on Thermal and Environmental Characteristics of Various Heating Systems in the Residential House)

  • 이충국;조성환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.121-128
    • /
    • 2005
  • This is about experimental comparison study between convective heating and radiation heating system to use the design criteria for residential house. Experiment was done in EC(environment chamber) under simultaneous outdoor condition for 4 kinds of heating system such as CRHP(Ceiling Radiant Heating Panel), BEHC( Bottom Electric Heating Coil Mat), EFCU( Electric Fan Coil Unit) and CEHU( Convective Electric Heating Unit). Result show that CRHP ,which is radiation heating system, can consume more 23% energy than convective heating system when it is operated by dry bulb temperature but can save 1 ${\sim}$ 10% when operated by glove temperature and 27% when operated by MRT.

  • PDF