• 제목/요약/키워드: Heating Temperature

검색결과 5,259건 처리시간 0.032초

다출력 유도가열 공정을 이용한 다공질 6061 알루미늄 합금의 기공 제어 공정 (A Process for the Control of Cell Size of 6061 Al foams by Multi-step Induction Heating Method)

  • 윤성원;강충길
    • 소성∙가공
    • /
    • 제12권5호
    • /
    • pp.449-456
    • /
    • 2003
  • Multi-step induction heating process was applied to the powder compact melting technique as a new heating process to achieve pinpoint accuracy, faster cycle time, repeatability, non-contact and energy-efficient heat in a minimal amount of time. The objective of this study is the establishment of the input data diagram of multi step induction heating process for automation of the fabrication process of 6061 Al foams with desired density. At first, proper induction coil was designed to obtain a uniform temperature distribution over the entire cross sectional area of specimen. By using this coil, foaming experiments were performed to investigate the multi-step induction heating conditions such as capacity, temperature and time conditions of each heating and holding step. On the basis of the obtained multi-step induction heating conditions, relationship between final heating temperature and fraction of porosity was investigated.

Effects of Local Heating on Whole Body Skin Temperature - Centered on the Comparison of Old Women & Female Collegians -

  • Shim, Boo-Ja
    • 패션비즈니스
    • /
    • 제6권3호
    • /
    • pp.84-93
    • /
    • 2002
  • The purpose of this study was to design functional clothing based on the physical characteristics of old women. The subjects of this experiment were 5 healthy old women and 5 college women. While the subjects were exposed to the circumstances of $28{\pm}0.5^{\circ}C$ and local heating at 7 areas (chest, abdomen, back, loin, hand, thigh and instep), their skin temperature, physiological reaction and psychological reaction were determined. The conclusions about the effects of local heating are as follows : 1. Skin temperature before heating was in the order of head-neck> trunk> upper limbs> lower limbs (Group A: old subjects) and head-neck> trunk> lower limbs> upper limbs (Group B: young subjects). 2. The heating pad was attached and detached for 30 minutes each. The sharpest rise and fall were recorded at 5 minutes with the pad on and off. Both groups had great changes in the body parts near trunk. 3. With the pad on and off, both groups showed no change in body temperature, blood pressure, and pulse rate. 4. Concerning the pervasive effects of local heating on whole body skin temperature, loin heating greatly increased other body parts in Group A. In Group B, the effects were large in heating chest, abdomen, back, loin, and thigh. 5. The loin part of old women has the greatest pervasive effect of local body heating.

열선 매입과 열선 및 버블시트 조합의 개량형 버블시트를 포설한 슬래브 콘크리트의 온도이력 특성 (Temperature History of the Slab Concrete applying Revised Bubble Sheet with Heating Cable)

  • 정은봉;안상구;정상현;고경택;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.23-25
    • /
    • 2013
  • In this study, the results are compared with the case of the concrete with embedded heating wire to verify the performance of the IB made in order to improve the workability and affordability, and to determine the effectiveness of early frost damage prevention. The IB was made using the 5W heating wire and layed on the upper surface of the concrete. The temperature was reduced to below 0℃ approximately within 24 hours, then approached the external temperature thereafter. On the other hand, when the 20W heating wire was used to make the IB and applied the same way, the temperature remained around -2 to 3℃ on the average even through the temperature was reduced to below 0℃, due to the heating wire with relatively large heating capacity. It appeared to reach 85% of the direct heating by embedding the heating wire relatively deeper in the concrete. However, it was determined that using the IB made with the 20W heating wire will prevent the early frost damage to some degree in -10℃.

  • PDF

EM시험에서의 Joule Heating 영향 및 초기저항값 (Joule Heating Effects and Initial Resistance in Electromigration Test)

  • 주철원;강형곤;한병성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권6호
    • /
    • pp.436-441
    • /
    • 1999
  • Joule heating effect in EM(Electromigration) test were performed on a bend test structure. EM test is done under high current densities(1.0-2.5MA/cm2), which leads to joule heating. Since joule heating is added to the controlled oven(stress) temperature, themetal line temperature is higher than the stress temperature. The increase in the stress temperature due to joule heating is important because EM phenomena and metal line failure are related to the stress temperature. In this paper, metal line was stressed with a current density of 1.0 MA/$cm^2$, 1.5MA/$cm^2$, 2.0MA/$cm^2$, 2.5MA/$cm^2$, for 1200 sec and temperature increase due to joule heating was less than $10^{\circ}C$. Also it took 30 minutes for the metal line to equalized with oven temperature. Recommendations are given for the EM test to determine the initial resistance of EM test structure under stress temperature and current density.

  • PDF

선상가열시 이동열원 조건에 따른 가열 판재의 온도분포에 관한 연구 (Study on Temperature Distribution for Various Conditions of Moving Heating Source During Line Heating Process)

  • 최윤환;이연원;최광
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권5호
    • /
    • pp.617-624
    • /
    • 2010
  • 선박 건조공정에서 외피의 곡면 가공에 많이 사용하는 가공법을 선상가열법이라고 한다. 선상가열법은 엔지니어의 숙련도에 따라 품질의 차이가 커지기 때문에 현재에는 엔지니어의 숙련도에 의존하지 않는 자동화기기를 사용하여 선상가열을 수행하는 경우가 많다. 본 연구에서는 자동화기기를 사용한 선상가열에 의한 가열판재의 온도분포를 조사하고자 한다. 선상가열시 적용되는 주요한 변수는 가열원의 이동속도, 강도 및 가열 방식 등이 있으며, 본 연구에서는 세 가지 변수를 중심으로 가열판재의 표면 및 내부온도가 어떻게 변화하는지를 조사하였다. 해석결과 가열원의 이동속도가 빨라질수록 판재의 피크온도는 낮게 형성되는 것을 확인하였고, 또한 열원의 크기에 따른 피크온도 및 온도분포가 선형적으로 변화하는 것을 정량적으로 계산할 수 있었다.

연소합성에 의한 NiTi 형상기억 합금의 제조 (A Manufacturing of NiTi Shape Memory Alloy by Combustion Synthesis)

  • 손인진;김학신
    • 열처리공학회지
    • /
    • 제8권2호
    • /
    • pp.120-126
    • /
    • 1995
  • The effects of heating rate on the combustion temperature, the ignition temperature, the microstrurcture and the shape memory ability of products formed by combustion were investigated. The ignition temperature decreased with increasing heating rate. Combustion temperature and ${\Delta}T$(difference temperature between the ignition temperature and the combustion temperature) increased with increasing heating rate. The grain size of the product increased with increasing heating rate. Combustion synthesis did not completely occur below the heating rate of $10^{\circ}C/min$. NiTi intermetallic compound was completely formed at the heating rate of $600^{\circ}C/min$ and the product by combustion method had a good shape memory effect.

  • PDF

저온온수 모세유관 바닥복사 난방시스템의 성능에 관한 실험적 연구 (Experimental Study on a Low-Temperature Hot Water Capillary Radiant Floor Heating System)

  • 조진균;박병용;이용준;정원호
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.68-82
    • /
    • 2018
  • Radiant floor heating systems with capillary tubes are energy saving systems in which hot water is circulated into capillary tube with a small diameter. In this study, the heating performance of capillary tube system is investigated in an experimental study and a simulation model. The results of the study showed that, the capillary tube radiant floor heating system maintains a more stable floor surface temperature in comparison a PB pipe system. In terms of energy consumption, the capillary tube radiant floor heating system proved to be more efficient than the PB pipe heating system at $40^{\circ}C$ of low temperature hot water supply. The difference between water temperature and room temperature can be held low for heating which saves energy. Low temperature radiant floor heating system with capillary tubes have significant advantages such as health improvement, low energy cost, optimum use of heat source(boiler) and higher operational efficiency.

열펌프에 의한 그린하우스 난방시스템의 열특성과 시뮬레이션 모델개발 (Thermal Characteristics and Simulation Model Development for Greenhouse Heating System with Heat Pump)

  • 노정근;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제26권2호
    • /
    • pp.155-162
    • /
    • 2001
  • The greenhouse heating system with heat pump was built for development of simulation model and validation. The computer simulation model for the system to predict temperature of air and soil and moisture content of soil in the greenhouse were developed, and its validity was justified by actual data. From the analysis of experimentally measured data and the simulation output, following results were obtained. 1. The expected values of inside air temperature for the heating system with heat pump were very much close to the experimental values. 2. In the heating system with heat pump, the expected values of day time surface temperature of soil by computer simulation were very much similar to the measured values, but those of night time were higher than the measured value by at most 2.0$\^{C}$. 3. The simulation model predicted temperature of greenhouse film as of 1$\^{C}$ below than the mean value of ambient air and greenhouse air temperature. 4. Heat loss value of daytime was found to be larger than that of nigh as much as 1.3 to 2.3 times for the heating system with heat pump. 5. In the heating system with heat pump, when the lowest ambient temperature was -8$\^{C}$∼-7$\^{C}$ the air temperature of greenhouse was 5$\^{C}$∼6$\^{C}$, thus the heat pump heating system contributed in greenhouse heating by 13$\^{C}$.

  • PDF

핫팩을 이용한 인체의 부위별 가온과 제거가 사지부 피부 열화상도에 미치는 영향 (Effects of local body heating and cooling on thermogram analysis of the extremity with hot pack)

  • 김소영;홍경희
    • 한국생활과학회지
    • /
    • 제23권6호
    • /
    • pp.1205-1215
    • /
    • 2014
  • The purpose of this study was to investigate the effect of local heating and cooling of various body parts on the skin temperature of the exposed extremities including neck. Hot pack was used to warm up the body of seven participants for 15 minutes and it was removed as the temperature of the hot pack decreased after 15minutes of warming. Thermograms of body surface with and without hot pack were analyzed intensively to observe the efficiency of the local heating of shoulder, abdomen, back waist, and foot on the skin temperature of ten area of the subjects' body. The results indicated that the absolute skin temperature of front upper arm and thigh was significantly higher depending on the area of heating, especially, in case of abdomen and foot heating, which was not observed at the back of the body. The rate of skin temperature of extremities such as finger, palm and foot was significantly different depending on the body area of local heating. Generally, it was found that back waist heating was not efficient to warm up and maintain the skin temperature of the body after removing the hot pack.

공동주택 세대별 난방 성능 개선 연구 (A Study on Improved Heating Performance of an Apartment Housing Unit)

  • 서정아;신영기;김용기;이태원
    • 설비공학논문집
    • /
    • 제28권2호
    • /
    • pp.69-74
    • /
    • 2016
  • Most hot water heating valves for apartments are constant-flow types, which limit the flow rate through an individual household for even distribution of heating water to other households. The constant-flow type is implemented by an on-off control. As a result, heating water is supplied intermittently and hence, indoor air temperature also fluctuates. Returning water temperature is also high, which reduces energy efficiency. To implement continuous feedback control, the indoor temperature dynamics was simulated to fit a measured temperature history by a state-of-the-art physical model. From the model, it was found that the most important disturbance is outdoor temperature and its effect on indoor temperature lasts about an hour. To cope with the slow response and the significant disturbance, a prediction control with proportional feedback is proposed. The control was found to be successful in implementing continuous heating water flow and improved indoor temperature control.