냉.온열 동시 제조시스템의 성능분석(I)-Simulation (Performance Analysis of Simultaneous Heating & Cooling Water Making System(I)-Simulation)

  • 박성룡;박준택;안영훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.266-271
    • /
    • 2001
  • In this study, the performance of the simultaneous heating & cooling water making system using R134a was investigated by simulation. The most important effect upon heating COP was intermediate pressure depending on input water temperature. With the input water temperature of $10^{\circ}C\;and\;20^{\circ}C$, optimum intermediate pressure were 923 and 1040kPa, respectively. At that optimum intermediate pressure, the maximum heating COP of the system operated between $0^{\circ}C$ evaporating temperature and $70^{\circ}C$ condensing temperature were 4.15 and 3.83. With installation of the subcoolers in high or low pressure section, the system COP was increased by reducing the refrigerant mass flow rate. Under the optimum pressure and $10^{\circ}C$ input water temperature, it was found that heating COP was maximized when the low-subcooler and high-subcooler capacity rate were taken by 14% and 13%, respectively.

  • PDF

맴브레인 구조를 이용한 미세발열체형 유량센서의 제작과 그 특성 (Fabrication on Microheater Flow Sensors Using Membrane Structure and Its Characteristics)

  • 정귀상;노상수
    • 한국전기전자재료학회논문지
    • /
    • 제11권11호
    • /
    • pp.996-1000
    • /
    • 1998
  • This paper describes the characteristics of Pt microheater using aluminum oxide films as medium layer and its application to flow sensors. Pt microheater have heating temperature of $390^{\circ}C$ at heating power of 1.2 W. Output voltages of flow sensors which were fabricated by integrating sensing-part with heating-part increase as gas flow rate and its conductivity increase. At $O_2$ flow rate of 2000 sccm, heating power of 0.8 W, output voltage of flow sensor is 101 mV under bridge-applied voltage of 5 V.

  • PDF

미세기공 알루미늄 소재의 기계적 성질 (Mechanical Properties of Aluminium Alloy with Cellular Structure.)

  • 윤성원;이승후;강충길
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.695-698
    • /
    • 2002
  • Induction heating process is one of the most efficient heating process in terms of temperature control accuracy and heating time saving. In the past study, fabrication process of cellular 6061 alloys by powder metallurgical route and induction heating process was studied. To supplement the framing conditions that studied in past study, effect of induction heating capacity and holding time at foaming temperature were investigated. Under the achieved framing conditions, teamed 6061 alloys were fabricated for variation of foaming temperature, and porosities(%)-foaming temperature curves were obtained by try-error experimental method. Uniaxial compression tests were performed to investigate the relationship between porosities(%) and stress-strain curves of framed 6061 alloy. Also, energy absorption capacity and efficiency were calculated from stress-strain curves to investigated. Moreover, dependence of plateau stress on strain rate was investigated in case of cellular 6061 alloy with low porosities(%)

  • PDF

Ni-Al계 금속간화합물 코팅에 미치는 고주파유도 가열 조건의 영향 (Effects of Induction Heating Conditions on Ni-Al Based Intermetallic Compound Coating)

  • 이한영;김태준;조용재
    • 대한금속재료학회지
    • /
    • 제48권2호
    • /
    • pp.141-147
    • /
    • 2010
  • An Ni-Al intermetallic coating has been produced by induction heating on mild steel. The effect of the induction heating conditions on the microstructure of the coating has been investigated. The reaction synthesis of the intermetallic compounds was promoted while increasing the heating rate and the holding time at reaction temperature. Especially, an NiAl phase corresponding to the initial composition of mixed powder was predominantly formed. However, the synthesis at low reaction temperatures occurred by solid state diffusion during the holding time and an Fe-Al reaction layer was formed at the interface with the substrate, regardless of the heating rate. The combustion synthesis of the intermetallic compound occurred at a temperature higher than 1023 K and resulted in an almost single phase NiAl structure.

Defrosting Behavior of Fin-Tube Heat Exchanger with PTC Heating Sheet

  • Jhee, Sung;Lee, Kwan-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권1호
    • /
    • pp.29-38
    • /
    • 2001
  • In this paper, the defrosting characteristics of a PTC heating sheet is investigated by means of a defrosting heat source for the fin-tube heat exchanger in a refrigerator The defrosting characteristics of the PTC heating sheet are examined and compared with those of a conventional electric heater experimentally. It is found that the characteristics of the water draining rate with the defrosting time show a smoothly oscillating pattern when the PTC heating sheet Is used, and the drained water is completely melted. The defrosting efficiency of the PTC heating sheet is found to be about 75%, which is about 25% higher than that of the electric heater. Also, the reduction of the defrosting time and the increment of the defrosting efficiency may be obtained by improving the arrangement of the heating elements of the healing sheet. It is shown that the defrosting time of the PTC heating sheet increases linearly with the amount of frost, whereas the defrosting efficiency is nearly constant. When applying the PTC heating sheet to the refrigerating system, one should notice the fact that the defrosting performance of the PTC heating sheet may be degraded due to the repetitive operations.

  • PDF

지역난방 2차측 유량변화가 내부 열유속 및 에너지소비량에 미치는 영향에 관한 실험적 연구 (The Experimental Study of the Heat Flux and Energy Consumption on Variable Flow Rate for Secondary Side of DHS)

  • 홍성기;조성환
    • 설비공학논문집
    • /
    • 제27권5호
    • /
    • pp.247-253
    • /
    • 2015
  • The presented work demonstrates the effects of flow rate on the secondary side of DHS (District Heating System). Increasing flow rate at the secondary side of DHS decreases energy consumption and time to reach the set-point of the heated room while increasing heat flux on the floor in the heating space. When flow rate increases, the overall heat transfer rate of radiant floor also increases. However, the results also show overall heat transfer rateto not increased linearly and thus the existence of an optimal flow rate for the secondary side of DHS. Control of the radiant floor with hot water may be more effectively accomplished with a combined control strategy that includes heat flux and a temperature set-point. This experimental analysis has been performed using a lab-scaled DHS pilot plant located at Jeonju University in Korea.

마이크로파 가열에 의한 도금슬러지 건조특성 (Drying Characteristics of Plating Sludge by Microwave)

  • 문경환;손종렬;김덕찬
    • 환경위생공학
    • /
    • 제13권1호
    • /
    • pp.9-15
    • /
    • 1998
  • Microwave heating and drying processes have been well established in various industrial applications. Feasibilities of successful application of microwave drying to many material have been shown on the laboratory or pilot-plant scale. The microwave drying behavior of plating sludge are considered in this paper. The plating sludge containing 70%, 80% and 90% water exposed to microwave power at 2,450 MHz, 700W. An experimental microwave drying apparatus was designed and constructed to monitor weight loss during drying. By studying the drying characteristic curve, the moisture in sludge was almost classified into two categories : free moisture and intestinal moisture. And the critical moisture contents at which the drying rate ceases to be constant were from 10.1 to 10.5%. A simple drying model is proposed which may be used to describe drying behavior of plating sludge. The constant rate and the falling rate periods in microwave drying were addressed separately. From the eqation of constant rate period the drying rate constants decreased exponentially with increasing depth. Microwave heating compared with conventional heating offered higher heating rates from 9 to 16 times. Therefore, microwave drying process can be effective in removing moisture from plating sludge.

  • PDF

줄 가열 변화에 따른 박막 트랜지스터 내 포논 열 흐름에 대한 수치적 연구 (Effect of Joule Heating Variation on Phonon Heat Flow in Thin Film Transistor)

  • 진재식;이준식
    • 대한기계학회논문집B
    • /
    • 제33권10호
    • /
    • pp.820-826
    • /
    • 2009
  • The anisotropic phonon conductions with varying Joule heating rate of the silicon film in Silicon-on-Insulator devices are examined using the electron-phonon interaction model. It is found that the phonon heat transfer rate at each boundary of Si-layer has a strong dependence on the heating power rate. And the phonon flow decreases when the temperature gradient has a sharp change within extremely short length scales such as phonon mean free path. Thus the heat generated in the hot spot region is removed primarily by heat conduction through Si-layer at the higher Joule heating level and the phonon nonlocality is mainly attributed to lower group velocity phonons as remarkably dissimilar to the case of electrons in laser heated plasmas. To validate these observations the modified phonon nonlocal model considering complete phonon dispersion relations is introduced as a correct form of the conventional theory. We also reveal that the relation between the phonon heat deposition time from the hot spot region and the relaxation time in Si-layer can be used to estimate the intrinsic thermal resistance in the parallel heat flow direction as Joule heating level varies.

Surimi Quality from Mechanically Deboned Chicken Meat as Affected by Washing Cycle, Salt Concentration, Heating Temperature and Rate

  • Min, Byung-Jin;Lee, Sung-Ki
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제17권1호
    • /
    • pp.131-136
    • /
    • 2004
  • The effects of salt concentration and heating conditions on the thermal gelation properties of surimi produced from mechanically deboned chicken meat (MDCM) were investigated. Chicken surimi was manufactured by washing (MDCM: 0.5% NaCl=1:4), standing, straining and centrifuging. The fat, water-soluble protein and heme pigment in the MDCM were removed by increasing washing cycles. The compressive force of the chicken surimi increased as the concentration of salt was increased from 0% to 5%. Total gel strength of the surimi measured by texture profile analysis showed a maximum in the range 3-5% NaCl. Microstructural analysis showed that the unfolding network structure of the surimi gel began to appear at NaCl concentrations>2%. The optimum heating condition for gelation was $90^{\circ}C$ for 40 min as this resulted in maximum values for measures of gel strength including compressive force, hardness, fracturability, adhesiveness, springiness, gumminess, chewiness and resilience. Chicken surimi gel formed by cooking at a heating rate of $1^{\circ}C/min$ to $90^{\circ}C$ showed better a texture than gels produced at $1.85^{\circ}C/min$. Our result show that a lower rate of heating improves chicken surimi gelation.

지열 히트펌프에서 운전변수가 냉난방 성능에 미치는 영향에 대한 실험연구 (An Experimental Study on the Effects of Operating Variables on the Cooling and Heating Performance of Geothermal Heat Pump)

  • 장근선;강희정
    • 설비공학논문집
    • /
    • 제23권8호
    • /
    • pp.562-570
    • /
    • 2011
  • In this research, an experimental study is performed to investigate the effects of system operating variables on the cooling and heating characteristics of heat pump system using geothermal heat source and carbon dioxide as a refrigerant. System variables analyzed include compressor frequency, electronic expansion valve opening, refrigerant charge, secondary fluid temperature and flow rate. Results show that optimum refrigerant charge and electronic expansion valve opening position exist at the maximum point of COP curve, and both cooling and heating capacity increase but COPs decrease with the increase of compressor frequency. The change of a secondary fluid temperature leads to variation of overheat area and enthalpy difference in the evaporator and gas cooler. which again results in considerable variations of cooling and heating capacity and COP. In the case of effects of secondary water fluid flow rate, both cooling capacity and COP increase with the increase of secondary flow in evaporator or gas cooler, whereas heating capacity and COP decrease with the increase of flow rate in gas cooler.