• Title/Summary/Keyword: Heating Curve

Search Result 220, Processing Time 0.032 seconds

Spalling Prevention of High Strength concrete Corresponding to the Various Heating Curves (가열온도곡선 변화에 따른 고강도 콘크리트의 폭렬방지특성)

  • Han, Cheon-Goo;Pei, Chang-Chun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.3 s.55
    • /
    • pp.127-134
    • /
    • 2009
  • This study investigated their properties of spalling resistance and residual compressive strength after fire test corresponding to various ISO, RABT heating curves, and contents of hybrid organic fiber of high strength concrete. The results were summarized as following. As fundamental characters of concrete with hybrid organic fiber, the flowability was directly declined as the increase of fiber contents, and air contents were decreased or increased a little bit, but there was not big difference. The compressive strength was gradually declined sluggishly at 28 days. As properties of fire resistance, in case of RABT heating curves, compare with ISO heating curves a spalling aspect showed till range that has much contents of hybrid organic fiber, but they are mostly peeling spalling, which means spalling aspect didn't happen to inside. In conclusion, in case of W/B 25% high strength concrete, the spalling was prevented over 0.04% of contents of fiber at ISO heating curve and over 0.10% of contents of fiber at the RABT heating curve. In case of spalling was prevented, mass reduction rate according to the change of heating temperature curves showed around 7% at ISO heating curves and around 9% at RABT heating curves. The residual compressive strength rate corresponding to the change of heating temperature curves showed 50%~60% at ISO heating temperature curves and 30%~35% at RABT heating temperature curves in case of spalling was prevented.

Pressure-Temperature Limit Curve of Reactor Vessel by ASME Code Section III and Section XI

  • M.J. Jhung;Kim, S.H.;Lee, T.J.
    • Nuclear Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.498-513
    • /
    • 2001
  • Performed here is a comparative assessment study for the generation of the pressure- temperature (P/T) limit curve of the reactor vessel. Using the cooling or heating rate and vessel material properties, the stress distribution is obtained to calculate stress intensity factors, which are compared with the material fracture toughness to determine the relations between operating pressure and temperature during cool-down and heat-up. P/T limit curves are generated with respect to crack direction, clad thickness, toughness curve, cooling or heating rate and neutron fluence, and their results are compared.

  • PDF

Pressure-temperature limit curve for reactor vessel evaluated by ASME code

  • Jhung, Myung Jo;Kim, Seok Hun;Jung, Sung Gyu
    • Structural Engineering and Mechanics
    • /
    • v.14 no.2
    • /
    • pp.191-208
    • /
    • 2002
  • A comparative assessment study for a generation of the pressure-temperature (P-T) limit curve of a reactor vessel is performed in accordance with ASME code. Using cooling or heating rate and vessel material properties, stress distribution is obtained to calculate stress intensity factors, which are compared with the material fracture toughness to determine the relations between operating pressure and temperature during reactor cool-down and heat-up. P-T limit curves are analyzed with respect to defect orientation, clad thickness, toughness curve, cooling or heating rate and neutron fluence. The resulting P-T curves are compared each other.

Production of Retort Food using Soybean Curd Residue (비지를 이용한 Retort Food의 제조)

  • Chun, Kie-Hwan;Kim, Byung-Yong;Hahm, Young-Tae
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.1327-1332
    • /
    • 1998
  • The optimum thermal condition of retort Biji product was determined by heat penetration curve, aerobic bacteria count and sensory test. Retort Biji showed a simple logarithmic heating curve regardless of solid content. Heating time was a $26{\sim}27$ min until Fo value reached 9 min and the amount of microorganism in the Biji product sterilized for 26 min at $121^{\circ}C$ were decreased to $10^{-4}\;CFU/g$, indicating the safe range for retort product. The rate of heat penetration was reduced as solid content and size of product were increased, whereas sterilization temperature and initial temperature of product influenced the heat penetration curve. Sensory scare indicated that there was no significant difference in color, flavor, and appearance among different thermal processes. However, Biji product sterilized at $121^{\circ}C$ showed the highest score in overall preference value.

  • PDF

The combustion test of assuming in parking space for fire resistance (지하주차장의 내화성능 평가를 위한 차량연소실험)

  • Kang, Seung Goo;Kim, Dong Jun;Lee, Jae Young;Harada, Kazunori;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.48-50
    • /
    • 2013
  • In this study, Car fire for test using ISO 9705 10MW Large Scale Calorimeter. Especially, study on the underground parking for the fire resistance performance. The underground parking lot of the fire resistance regulations in according to with the standard heating curve in Korea. Because of this burning car through experiments to the propose a new heating curve.

  • PDF

Fire Resistance of the Concrete Corresponding to the Various Fiber Contents and Heating Curves (섬유의 종류 및 온도가열곡선 변화에 따른 콘크리트의 내화특성)

  • Han, Cheon-Goo;Pei, Chang-Chun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.5
    • /
    • pp.101-107
    • /
    • 2008
  • This study investigated fundamental characters of the concrete according to various fiber types and contents and their properties of spatting resistance and residual compressive strength after fire test corresponding to ISO and RABT heating corves. The results were summarized as following. The Flowability was gradually declined as the increase of fiber contents, and it was the most favorable with nylon(NY) fibers. The decrease of air contents due to increasing fiber contents was in order by polypropylene(PP), polyvinyl alcohol(PVA) and NY fibers. The compressive strengths were over 40 MPa at 7 days and 50 MPa at 28 days. It was in order by PVA, PP and NY fibers. For the spatting properties, all specimens were prevented at ISO heating curve. In the other hand, the partial spatting at the surface occurred on the plain without fibers, but it was prevented over 0.10 % of PVA and 0.05 % of PP and NY fibers at the RABT heating curve.

Thermomechanical Characteristics for Structural Material of Supersonic Vehicle (초음속 비행체 구조재료에 대한 열기계적 특성)

  • Kim, Jong-Hwan;Lee, Kee-Bhum;Lee, Kuong-Yong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.2 s.21
    • /
    • pp.77-87
    • /
    • 2005
  • The thermomechanical characteristics were evaluated for 17-4PH stainless steel widely used in supersonic airframe subjected to both aerodynamic loading and heating. The thermomechanical tests were conducted under both elevated temperature and rapid heating condition from $1^{\circ}C/sec\;to\;28^{\circ}C/sec$. The thermomechanical behaviors under rapid heating were compared with those of elevated temperature after 1/2 hour exposure in terms of yield stress to investigate the influence of heating rates. A heating rate-yield temperature parameter was suggested for rapid heating based on time-temperature parameters, and master yield stress curve was obtained by using these parameters. The experimental results and methodology from this study can be used as basic engineering data when designing supersonic vehicle structures subjected to aerodynamic loading and severe heating environment.

Computer Curve-Fitting of Crystallization Peak of Amorphous $Pb(Fe_{2/3}W_{1/3})O_3$ Ceramics (비정질 $Pb(Fe_{2/3}W_{1/3})O_3$ 결정화 피크의 컴퓨터 합성)

  • 김남경
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.10
    • /
    • pp.1202-1208
    • /
    • 1994
  • On heating amorphous Pb(Fe2/3W1/3)O3 ceramics, glass transition occurred at 35$0^{\circ}C$, crystallization at 394~420, 485~550 and 540~571$^{\circ}C$ (depending on the heating rates of 2.5~8$0^{\circ}C$/min), phase transformation at 680 and 73$0^{\circ}C$, and melting at 935$^{\circ}C$. A curve-fitting computer program was made using FORTRAN, based on a kinetic equation. Reconstructed thermograms (using the program) turned out to be very close to the measured DSC results for all the heating rates, with average deviation of only 4% at maximum.

  • PDF

The Study of Analytical Chemistry of the Modification of Manganese Dioxide (Report Two). Quantitative Determination of ${\gamma}$-Manganese Dioxide by Differential Heating Curves (變態二酸化 망간의 分析化學的 硏究 (第二報). 示差熱曲線에 依한 ${\gamma}-MnO_2$의 定量法)

  • Chan Ho Kim
    • Journal of the Korean Chemical Society
    • /
    • v.15 no.5
    • /
    • pp.241-245
    • /
    • 1971
  • Endothermic peak of transformation of ${\gamma}-MnO_2$ was obviously shown by differential heating curve in the present study, and the transformation temperature was different from other modification. ${\gamma}-MnO_2$ carried out to analyze exclusively, by means of the half area method in corresponding endothermic peak of differential heating curve. ${\alpha}-\;and\;{$beta}-MnO_2$ (Pyrolusite) containing in sample about 75% is interfered about ${\pm}$10% of the relative error, and while those of below 50% is interfered about ${\pm}$5%.

  • PDF

Investgating Effects of Peak Load of Korean Power System from Electric Heating appliances except House (비주택용 전기난방기구가 우리나라 첨두부하에 미치는 영향 검토)

  • Kim, Yong-Ha;Lee, Kwang-Sung;Heo, Dong-Ryeul;Lee, Sung-Jun;Lee, Yong-Suk;Woo, Sung-Min;Son, Seung-Kee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.442-447
    • /
    • 2006
  • This paper investigates the shadow amount of edifice and according to time zone used by its Electric heating appliances, it is analyzed that Electric Heating Power Load affects Heal power load variation curve. Also, in case that the far infrared ray heating system, which are used as new electric heating system, occupies some of the existing Electric heating appliances, it is analyzed that the Electric heating power load affects the Peak load power in Korea.

  • PDF