• Title/Summary/Keyword: Heating Characteristic

Search Result 435, Processing Time 0.026 seconds

Analysis of Control Error Factors of a Thermal Output Experiment for Radiant Heating Panels (복사난방패널 방열량실험의 제어오차요인 분석)

  • Shin, Dae-Uk
    • Land and Housing Review
    • /
    • v.9 no.4
    • /
    • pp.33-42
    • /
    • 2018
  • As a radiant heating panel gets more popularity, the need to study on evaluation method of thermal output of the panel also becomes increasing. Generally, the chamber using method is applied to evaluate the thermal output through an experiment. However, the chamber using method cannot be used due to the limitations on space and cost. EN1264 addresses the test equipment to evaluate the thermal output by using simpler experimental setup, and introduces application method in detail. However, there is not enough description of control methods to meet the experiment condition, and it is difficult to meet this when practical experiment. Therefore, this paper analysed the control error factors of when the thermal output experiment is performed. When EN1264 method is applied to evaluate the thermal output of the radiant floor heating panel, the error factor which is caused by the characteristic of test equipment cannot be removed by the control methods of chamber using method. In addition, the error factor can be occurred at the element which is located out of the control system. These possible error factors are defined as the characteristic error factors.

Eddy Current and Thermal Analysis of Induction Heating Roll (유도가열 히팅롤의 와전류 및 열해석)

  • Jang, S.M.;Cho, S.K.;Yoon, I.K.;Jeong, S.S.;Park, H.C.;Son, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.709-711
    • /
    • 2002
  • The Induction heating is used in various industry and ever-increasing number of applications. The heating roll, which is a kind of induction heating, widely used in curing of coatings and fiber industry. In this papaer, we analized thermal characteristic of induction heating roll by threedimensional eddy-current analysis. Using this analytic results, We could predict the thermal distribution of induction heating roll

  • PDF

Method and Analysis of Dynamic Simulation for Ondol Heating (온돌 난방에 대한 동적 시뮬레이션 및 분석)

  • Hong, Hi-Ki;Kim, Si-Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.375-382
    • /
    • 2010
  • Ondol heating, a kind of radiant floor heating, is a main method used in housing units in Korea. Building energy simulation including ondol and relevant facilities has not been performed due to its complexity. For evaluating energy consumption and indoor temperature variation, a new method should be proposed. At the present work, a dynamic simulation on ondol heating was tried by combining TRNSYS and EES. Characteristic functions for a pump, hot water coils and a gas boiler were simultaneously solved by EES, and calculated flow rates and supply temperature of hot water were provided as inputs of the active layer of TYPE 56 in TRNSYS. The results by the simulation on a typical housing unit in Korea shows a good trend in a viewpoint of actual behavior of ondol heating.

Effect of Ohmic Heating on Characteristics of Heating Denaturation of Soybean Protein (옴 가열이 대두 단백질의 열변성에 미치는 영향)

  • Cha, Yun-Hwan
    • The Korean Journal of Food And Nutrition
    • /
    • v.24 no.4
    • /
    • pp.740-745
    • /
    • 2011
  • Ohmic heating uses electric resistance heat which occurs equally and rapidly inside food when an electrical current is passed throught. In this study, we observed the physical & chemical characteristics changes which occurs in soybean protein during heating denaturation by using ohmic and conventional heating. After the ohmic heating process, we could not find any change of the primary protein structure in the denaturated soy protein samples. However, the rate of imbibed water(RIW) of the ohmic samples was 2 times faster than that of the conventional samples. Also the ANS-surface hydrophobicity was decreased, which is very closely related to RIW. In the differential scanning calorimeter(DSC) analysis result, all 7S soyprotein fraction samples were completely denaturated by ohmic and conventional heating. However, the 11S samples were completely denatured only by ohmic heating. According to the DSC result, we decided that soyprotein was damaged by temperature and electrical current during ohmic heating. The damage of electrical current was a cause of the characteristic changes.

Measurement and Simulation of Heating Energy for Apartments with District Heating (지역난방 아파트에 대한 난방에너지 실측 및 시뮬레이션)

  • Lee, Eun Ju;Lee, Doo Young;Hong, Hiki;Kim, Young Kyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.572-578
    • /
    • 2014
  • Heating energy was measured in an apartment housing unit with a district heating system, varying the kind of hot water distributors. Ondol coils passing through a living room raised the temperature of the room where the heating was turned off. Including this characteristic of Ondol heating into the modeling, we performed simulations and showed a verification by comparison with the results of measurements. As a result, a main flow control method, which changes hot water flow rate supplied to a housing unit according to the thermal load, can reduce the supplied flow rate and lower the return temperature, compared with a constant flow method. That can result in decreased heat loss in utility-pipe conduits even though the heating energy supplied is almost the same. An outdoor reset control that raises the temperature of the supplied hot water if the outdoor temperature falls has the effect of a quicker response in heating than the reduced flow rate and return temperature.

The Effectiveness of Weaving Motion and Determination of Optimal Heating Condition in Line-heating (선상가열시 위빙방식의 효율성과 최적 가열조건 결정에 관한 연구)

  • 하윤석;장창두
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.41 no.4
    • /
    • pp.68-76
    • /
    • 2004
  • Inherent strain method for analyzing deformation of line-heating is substituting experiments of high cost, because of its high accuracy and quickness. Nowadays, the progressing forms of line-heating are not straight moving motions used to traditional studies, but weaving motions which can diversely input heat source. In shipyard, reasons of weaving motions are induction of a special characteristic by water cooling, maximum temperature limitation for keeping plates from melting, and rhythm for workman's maintaining velocity. On this study, a method which can obtain optimal weaving heating condition was presented, some examples were introduced, and the results corresponded to works of shipyard. Lastly, what the specifications of plates on efficiency are is presented, through the quality standard of shipyard and FEM heat transfer simulation. The ultimate purpose of line heating is the automation, so in case of plates which need weaving heating, the optimal heating condition suggested by this study can be used well in designing coil specifications of induction heaters which are heat input sources of new generation.

Study on control system design for washer fluid heating system (워셔액 가열시스템의 제어시스템 설계에 관한 연구)

  • Lee, Je-Sung;Kim, Jung-Hyun;Won, Jong-Seob;Lee, Seon-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2441-2451
    • /
    • 2012
  • This paper presents the design of a control system for improving performance of a washer fluid heating system (WFHS) which is capable of removing frost, ice, snow and/or other debris from windshield. First, for the WFHS, a modeling process is described, and the extraction of characteristic parameters of the model are made by experimental studies. Design variables that affect on performance of the WFHS are also presented. Secondly, a control system is proposed for improving heating performance of the WFHS, and its performance is verified through experiments. The key feature of the proposed control system is to regulate the current of a booster converter input to the WFHS up to the target value that is set to guarantee heating performance. Target current is calculated by using initial temperature value and employing the mathematical model derived in the paper. Computer simulation and experimental results show that the proposed control system can perform heating operations in a way to satisfy per-determined target performance of the WFHS.

A Study on Characteristic of High Frequency Induction Heating for Local Heating (국부가열용 고주파 유도가열 특성에 관한 연구)

  • Jin, Hyung-Kook;Lee, Dong-Ju;Shin, Sang-Beom
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.60-60
    • /
    • 2010
  • Since the curved hull plate was made by a series of manufacturing process including cold bending, manual local heating and correction work, the accuracy of curved plate strongly depends on the proficiency of worker. So the demands on the automatic local heating system for curved hull plate have continuously increased and the various researches relevant to it have been performed. Generally, the heat sources used for local heating were flame and induction heat. In terms of initial cost, flame heating is in a better favorable position than induction heating. However, from the viewpoint of the control of heat, induction heating has more advantage. So the various researches related to apply the induction heating to the automatic forming system has been performed. The purpose of this study is to establish the proper capacity of high frequency induction heating system for forming the curved hull plate. In order to do it, the proper coil shape for local heating was designed and the efficiency of induction heating system was determined by comparing of temperature results obtained by FEA and experiment. With the results, the extensive FEA was performed to identify the effect of heated plate dimension, cooling method and the capacity of induction heating system on the amount of heat loss introduced by induction heating. Based on the results, the proper capacity of high frequency induction heating system was proposed.

  • PDF

A Study on Application of Radiant Floor Heating in Large Space (대공간의 바닥 복사 난방 적용에 관한 연구)

  • Ahn, Min-Hee;Choi, Chang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.79-85
    • /
    • 2007
  • This paper addresses the indoor air quality when radiant floor heating is applied in large space. Radiant heat exchange between surfaces depends on the orientation and the temperature of the surfaces. Also, the temperature and the radiant characteristic of the wall and the roof that face the floor have great influence on the indoor air environment due to the largeness of the wall and the roof in large spaces. In this study, we simulate a test-cell(25X20X10) using a ies YE And using a CFD(microflo in VE), an indoor air environment was investigated to establish the optimum temperature of floor. At the first time of the heating, high floor temperature is demanded. At the middle of the heating, however, the temperature of the residential space was formed appropriately, although the temperature of the floor was set low.

A Study on the Thermal and Electrical Characteristics with Manufacture of the Heating Element by Using Carbon with Bar Type (봉상 카본 발열체의 제조와 열 및 전기적 특성에 관한 연구)

  • 배강열;이광성;정한식;정희택;정효민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.430-437
    • /
    • 2004
  • This paper is intended as an investigation of study on the thermal and electrical characteristics of the carbon heating element. In this experimentation, the electric material used is the crystalline graphite a kind of natural graphite. The bentonite is used to solidify the heating element and the vacuum furnace is used for sintering it. It is noted that the natural drying time should be at least 58 hours. The plating of the electric pole with the electroless nickel showed the lowest contact resistance among others. The resistance shows linear variation with regard to length. For the insulation and resolution, the glaze coating is best with 80% of water content. The temperature rising characteristic of the heating element is better than sheath heater saving 43% of rising time. The correlation equation for temperature was obtained with the electric power.