• 제목/요약/키워드: Heating Apparatus

검색결과 170건 처리시간 0.027초

erratum : 전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구 (erratum : A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus)

  • 장한솔;정우령;문정현;최성경;성원석;황민섭;이승덕;김경호;윤종화;김은정
    • 대한한의학회지
    • /
    • 제44권1호
    • /
    • pp.128-128
    • /
    • 2023
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

고분자물질 및 계면활성제의 유동마찰 저감 특성 비교 연구 (A Comparison Study on Flow-Friction Characteristic of Polymer Solution and Surfactant as Drag Reduction Additive)

  • 하재순;유재성;김성수;조성환;윤석만;엄재식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.863-868
    • /
    • 2009
  • The drag reduction(DR) for Betaine+Amin and Xantan Gum as kinds of surfactant and Polyacrylamide as kinds of polymer solution according to the fluid velocity, temperature and surfactant concentration were compared experimentally. For this study, two kinds of experimental apparatus for short time and long time measurement were established. Each experimental appratus was equipped with hot water storage tanks, pumps, testing pipe network, flowmeter, two pressure gauges and data logging system was built for them. Results showed that Betaine+Amin and Xanthan Gum as kinds of surfactant had appeared optimal DR around 200-500 ppm and their DR tended to be decreased when flow velocity increased but Polyacrylamide as kinds of polymer solution showed the opposite trend to be increased when flow velocity increased. The both of them showed above 40% DR in the case of better condition by the short term measurement. But Polyacrylamide as kinds of polymer solution showed more degradation than Betaine+Amin and Xanthan Gum as kinds of surfactant by the long term measurement. As a result, Betaine+Amin and Xanthan Gum as kinds of surfactant showed better materials to use to the district heating system.

  • PDF

생양파와 부패된 양파의 휘발성 유기성분 분석 (Analysis of Volatile Organic Components from Fresh and Decayed Onions)

  • 박은령;고춘남;김성호;김경수
    • 한국식품영양과학회지
    • /
    • 제30권6호
    • /
    • pp.1011-1020
    • /
    • 2001
  • SDE 추출방법 과 GC-FID와 GC/MS 분석에 의하여 서로 다른 저장조건에서 부패된 양파의 휘발성 유기성분을 분석하였다. 생양파, 비가열부패양파, 반부패양파, 완전부패양파에서 각각 115, 143, 123, 137종의 화합물이 확인되었으며, 이들은 ester류, aldehyde류, ketone류, alcohol류, 황함유 화합물류들이었다. Dimethyl trisulfide, dimethyl disulfide, diprnpyl trisulfide, 3,5-diethyl-1,2,4-trithiolane는 생양파와 비가열부패양파에서 다량 확인되었으며, 양파가 부패도에 따라 휘발성 유기성분들 중 황함유 화합물류는 유의적으로 감소하였다. 황함유 화합물류를 제외한, 가열 후 반부패와 완전부패양파의 휘발성 유기성분은 주로 ester류, ketone류, alcohol류들이었으며, 특히 ketone류는 가열 후 완전부패 양파의 휘발성 유기성분의 구성에 큰 비중을 차지하고 있었다. 각각의 시료에는 170.3 mg/kg, 155.4 mg/kg, 121.2 mg/kg, 187.0 mg/kg 휘발성 유기 성분이 각각 함유되어 있었으며, 효소 불활성화에 의해 가열 후 반부패된 양파에서 휘발성 유기성분의 생성이 저하되었음을 알 수 있었으며,이를 계속하여 부패시킨 완전부패양파에서는 소량으로 함유되어 있던 휘발성 유기성분이 다시 증가되었음을 확인할 수 있었다.

  • PDF

화목보일러 화재위험성에 관한 실험적 연구 (An Experimental Study on the Fire Risk of a Firewood Boiler)

  • 이성룡
    • 한국화재소방학회논문지
    • /
    • 제29권3호
    • /
    • pp.37-42
    • /
    • 2015
  • 본 연구에서는 농촌지역을 중심으로 대표적인 겨울철 난방기구인 화목보일러 화재위험성을 평가하였다. 화목보일러 연료투입구 주변 및 연통의 온도를 측정하였으며, 연통 내부에 축적되는 타르의 화재 위험성을 평가하였다. 연료 투입구개방 상태에서 전방의 온도를 측정한 결과 화목 투입구로부터 40 cm 이상 떨어진 영역에서는 온도가 약 $40^{\circ}C$ 이하를 유지하였다. 본 연구에서는 연료 투입구 외부로 비산되는 불티가 60 cm 이내의 범위에 비산되었다. 연통 내부에서는 온도가 $600^{\circ}C$ 이상까지 상승하였으며, 화목보일러 본체로부터 2 m 떨어진 위치의 연통 내부에서 온도가 $420^{\circ}C$ 이상 도달하였다. 연통 내부의 타르를 수거하여 발화온도를 측정한 결과 약 $398^{\circ}C$를 기록하였다. 화목보일러 본체 및 연통 표면에서 온도가 약 $300^{\circ}C$ 이상 도달하였으며 가연물이 접촉될 경우 착화되었다.

수열원 펌프에서의 R-22 대체냉매의 응축열전달특성에 관한 연구 (Condensing Heat Transfer Charactristics of R-22 Alternative Refrigerants on Water Sources Heat Pump)

  • 김기수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권3호
    • /
    • pp.285-293
    • /
    • 1998
  • This paper presents an experimental study on condensing heat transfer characteristics of R-22 alternative refrigerants, R-290 and R-410a on water sources heat pump. The apparatus mainly consisted of vapor pump condenser used to the test section evaporator manual expansion valve and measuring device. Test section constructed a smoothed tube of 10.07 mm ID and 12.7mm OD with a total length 6,300 mm was horizontal double pipe counterflow condenser. The refrigerants R-22, R-290 and R-410a were cooled by a coolant circulated in a surrounding annulus. Experimental range of mass velocities was changed from about 100 to 300 kg/($m^2$.s) and inlet quality 1.0 The credibility of experimental apparatus was 6 percent between heating capacity and cooling capacity added to compressor shaft power. The condensing heat transfer coefficients were increased with increasing mass velocity. However in case of R-290 they were more increasing than those of R-410a and R-22 Comparing the heat transfer coefficient between the experimental data and other's data the Cavallini-Zecchin's data was revealed to more similar prediction of author's experimental results on the average heat transfer coefficients.

  • PDF

축사 전기설비 화재위험성 실태조사 (A research on the actual condition fire dangerousness for electric installation of stables)

  • 이영수;김명수;김만건;김혁수
    • 한국화재조사학회지
    • /
    • 제9권1호
    • /
    • pp.65-77
    • /
    • 2006
  • 축사에서 발생하는 화재건수가 높은 수준은 아니지만 화재가 발생하면 많은 재산피해가 발생하여 국가나 개인적으로 막대한 피해가 발생한다. 축사에서 발생하는 화재를 예방하기 위하여 전국 축사에 대한 전기설비 설문조사를 실시하여 축사 관리자의 안전 의식을 파악하였고, 축사에서 많이 사용하는 전기설비 중 전기화재위험성이 높은 난방장치, 환기장치, 분전반, 배선기구 등 전기기구의 사용실태를 파악하였다. 축사에서 전기로 인한 화재가 발생하지 않도록 이 자료가 축사의 전기화재 예방자료로 활용되었으면 하는 바람이다.

  • PDF

가열기구에 따른 조리방법이 돼지고기의 품질특성에 미치는 영향 (Effect of Cooking Methods with Various Heating Apparatus on the Quality Characteristics of Pork)

  • 전기홍;권기현;김은미;김영붕;최윤상;손동인;최진영
    • 한국조리학회지
    • /
    • 제21권1호
    • /
    • pp.1-14
    • /
    • 2015
  • 본 연구에서는 돼지고기 삼겹살과 목살의 가열처리방법에 따른 새로 개발된 PCM 처리와 이중팬을 제작하여 사용하였으며, 기존의 가열조리방법과 비교하여 이화학적 특성과 관능특성을 비교하였다. 돼지고기 삼겹살과 목살의 수분함량은 찌기처리구에서 60.2%, 67.2%로 높게 나타났으며, 조지방은 삼겹살은 숯불처리구에서 33.2%, 목살은 전기그릴처리구에서 16.0%로 가장 높았다(p<0.05). 조단백질의 경우, 삼겹살은 스팀처리구가 18.4%로 높았고, 삶기처리구는 15.4%로 유의적으로 낮았다. 또한, 목살은 전기그릴처리구에서 25.2%로 유의적으로 높게 나타났다(p<0.05). 보수력과 가장 관계가 깊은 가열감량은 삼겹살과 목살 모두에서 숯불구이처리구 40.18%, 36.98%로 유의적으로 높았고, 전단력에서 삼겹살은 오븐처리구에서 $2.76kg/cm^2$으로 목살은 이중 팬처리구에서 $3.67kg/cm^2$으로 가장 낮았다(p<0.05). 육색 시험결과 L값은 삶기처리구에서 65.16, 59.72로 가장 높았고(p<0.05) b 값의 경우, 삼겹살은 삶기처리구에서 2.32로 가장 낮았다(p<0.05). 관능평가 결과 전체적인 기호도 항목에서 삼겹살의 경우, 전기그릴처리구에서 7.56점으로 높았다. 목살은 팬구이처리구에서 7.22점으로 가장 높았으며, 반면, 삶기처리구에서 5.88점으로 가장 낮았다(p<0.05).

다중공 평판형 셀기기에서 하이드레이트 생산실험 분석연구 (An Experimental Analysis of Hydrate Production using Multi-Well, Plate-Type Cell Apparatus)

  • 배재유;성원모;권순일
    • Korean Chemical Engineering Research
    • /
    • 제45권3호
    • /
    • pp.304-309
    • /
    • 2007
  • 본 연구에서는 감압법 및 열자극법에 의한 메탄하이드레이트 생산실험을 수행하기 위해 고압의 다중공 평판형 셀기기를 설계 제작하였다. 이 실험장비를 이용하여 고투과성 미고결 시료 공극시스템에서 감압법과 열자극법에 의한 생산실험을 수행하여 생산메카니즘을 분석하였다. 감압법에 의한 생산실험 결과, 일반 가스전과는 달리 하이드레이트 해리에 의한 공극내에서의 소스효과로 인해 일시적으로 압력이 상승하고 또한 흡열반응으로 인해 온도가 하강함을 확인 하였으며, 열자극 생산실험을 수행한 결과에서는 감압법의 경우 열자극법에 비해 해리속도가 느리게 진행되어 가스생산이 낮은 상태로 지속되는 것으로 나타났다. 한편, 열자극법 중 열을 가한 후 곧바로 생산하는 경우, 주입지점 주변에서만 해리되고 또한 그 지역에서만 투과도가 커지는 것으로 나타났으며, 생산초반 이후 해리속도는 soaking까지 시행한 경우에 비해 해리가 느리게 진행됨을 알 수 있다. 한편, 본 연구의 낮은 하이드레이트 포화도를 갖는 미고 결시료 공극시스템에서 열자극법의 적정 soaking 시간 규명실험을 통해 압력과 생산거동을 고찰하였다. 그 결과, 6분간 soaking 한 경우, 온도 하강에 의한 하이드레이트의 재형성으로 2분 및 4분간 soaking한 경우보다 낮은 회수율을 보였다. 본 연구의 실험결과는 향후 높은 하이드레이트 포화도를 갖는 고결 시료 공극시스템에서의 실험을 통해 더욱 확연히 드러날 것으로 예상된다.

천연섬유분진의 연소특성에 관한 연구 (A Study on Combusiton Properties of Natural Fiber Dust)

  • 이창우;김정환;현성호
    • 한국화재소방학회논문지
    • /
    • 제13권1호
    • /
    • pp.3-10
    • /
    • 1999
  • 천연섬유분진의 연소특성을 조사하고자 국내 방적공장의 집진기에서 직접 포집된 천연섬유분진을 열시차 및 열중량 분석기를 이용하여 온도에 따른 분해 특성을 조사하였고, 자연발화 시험기를 이용하여 시료의 입도분포 및 시료량에 따른 천연섬유의 연소특성을 시간에 따른 온도의 변화로 측정하였다. 또한 자연발화 시험기 내부의 공기흐름에 따른 연소특성을 조사하고자 송풍과 무풍 상태에서의 자연발화 또는 훈소특성을 조사하였다. 열분석 결과 승온속도가 증가할수록 발열개시온도가 현저히 낮았고 발열량도 크게 증가하였다. 또한, 천연섬유 분진은 시료량과 입도가 증가할수록 발열개시온도가 낮아지고 있으며, 연소형태는 모두 훈소 상태를 보였다. 시험기 내부가 송풍상태일 때 보다 무풍상태로 실험하였을 때 발열개시온도가 약간 낮으며, 발열량도 크게 나타났다.

  • PDF

폐 CPU 칩의 해체장치 제작 및 성능 평가 (Manufacture of Dismantling Apparatus for Waste CPU Chip and Performance Evaluation)

  • 조아람;박승수;김보람;박재구
    • 자원리싸이클링
    • /
    • 제25권6호
    • /
    • pp.3-12
    • /
    • 2016
  • 본 연구에서는 F-PGA 타입의 CPU 칩과 W-BGA 타입의 CPU 칩을 대상으로 금(Au)의 함량 및 분포 상태를 확인하였다. 그 결과 F-PGA 칩의 경우, 금의 80.8%가 칩 터미널(terminal)부분에, W-BGA 칩의 경우에는 베어다이(bare die)에 금이 89.8% 편재되어 있는 것을 확인하였다. 이와 같이 대부분의 금이 칩의 특정 부분에 존재하는 사실로부터 CPU 칩의 해체장치를 고안하게 되었다. CPU 칩 해체실험의 조작변수는 롤러 회전속도, IR 히터의 가열 온도, 가열 시간으로 하였다. F-PGA 칩의 경우에는 가열 온도 $300^{\circ}C$, 가열 시간 90초 조건, 그리고 W-BGA 칩의 경우에는 롤러속도 90 rpm, 가열온도 $300^{\circ}C$, 가열 시간 180초 조건에서 칩 터미널과 베어다이를 각각 완전하게 분리/회수할 수 있었다.