• Title/Summary/Keyword: Heating Apparatus

Search Result 170, Processing Time 0.023 seconds

Experimental analysis of pultrusion process for phenolic foam composites (발포 복합재료 Pultrusion 공정의 실험적 해석)

  • Lee WooIl;Yun MyungSeok
    • Composites Research
    • /
    • v.18 no.3
    • /
    • pp.47-52
    • /
    • 2005
  • Pultrusion process of phenolic foam composite is investigated. Phenolic foam composites provide heat and flame resistance with less weight. When made into foam, a variety of properties can be obtained with different bubble size and number density. In this study, effect of process variables on the foaming characteristics of phenolic resin composites during pultrusion process has been studied experimentally. The process variables considered are the heating temperature and the pulling speed as well as the mass fraction of blowing agent. Experiments were performed using a laboratory scale pultrusion apparatus. Optimal process condition was found by observing the micro-morphology.

Capacity Modulation of a Heat Pump System by Changing the Composition of Refrigerant Mixtures (혼합냉매의 성분비 조절을 통한 열펌프의 용량조절)

  • 김민성;김민수;김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.258-266
    • /
    • 2000
  • Experimental investigation and cycle simulation of a capacity modulation of a heat pump system using a hydrofluorocarbon (HFC) refrigerant mixture, R32/134a as an alternative to R22, have been done. In the cycle simulation, the refrigeration system was operated by assigning the temperatures of the external heat transfer fluids with the heat exchangers generalized by an average effective temperature difference. Heating capacity, cooling capacity, and coefficient of performance (COP) of the system were investigated at several operating conditions. Experimental apparatus which had a refrigeration part and a composition changing part was built, and the performance of the heat pump system filled with R32/134a mixture was investigated. A gas-liquid separator was used in the experiment to change the composition by collecting the vapor and the liquid Phase separately, The mass fraction of the charged refrigerant in the heat pump system was 40/60 and 70/30 by weight percentage. The composition of the refrigerant with initial composition of 40/60 varied from 29/71 to 41/59 in the refrigeration cycle. For the refrigerant with initial composition of 70/30, the composition varied from 65/35 to 75/25.

  • PDF

Measurement of The Thermal Contact Conductance in Nuclear Fuel Element (핵 연료 요소내의 접촉 열전도도 측정)

  • Sung-Deok Hong;;Goon-Cherl Park
    • Nuclear Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.75-81
    • /
    • 1990
  • Experiments to predict the thermal contact conductance between the fuel pellet and cladding have been performed, which is important to determine the temperature distibution within the fuel rod. UO$_2$and Zircaloy-2 are used in these experiments. The measuring apparatus is composed of a presser which controls the contact pressure, a thermometer with 5.5 sheathed thermocouples, a vacuum pump, pellet and cladding rods, and two heating devices, etc. The thermal contact conductances were measured with varying the contact pressure and surface roughnesses of UO$_2$and Zircaloy-2 bars. The results show that an increase in the contact pressure and a decrease of surface roughness resulted in increase of the thermal contact conductance. Finally, a fitting correlation has been established and compared with widely-used correlations.

  • PDF

The study of developing the freezing seal isolation method for the pre insulated heat transfer pipe (이중보온 열수송관에 대한 동결차수공법개발에 관한 연구)

  • You, Byounghee;Ahn, Changkoo;Kim, Woocheol;Shin, Ikho
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.105-112
    • /
    • 2017
  • A lot of piping systems have been used from nuclear power systems to water supply systems. The maintenance of the piping systems is needed to ensure proper operation of the piping systems. Failure of the large pipe systems especially such as KDHC(Korea District Heating Corporation) can be a matter directly related to the enterprise productivity and profitability. It can also lead to very important issues in promoting public safety and convenience. Therefore a method of quick and safety repairs have been emerged as the most important problem. In this study, freezing seal isolation method using liquid nitrogen cryogenic refrigerant was developed for the maintenance of a pre insulated heat transport pipe of KDHC with a diameter of 300 mm. In this study, by employing computational analysis techniques we performed the flow and heat transfer analysis for the targeted pre insulated heat transfer pipe and freezing seal jacket(ice-Plug) and have selected for optimal system. The detailed design model based on the results of the computational analysis finally was produced. A laboratory-scale test apparatus were designed and the freezing seal isolation self-test carried out. Also the performance assessment tests in the test bed of KDHC were carried out for on-site application.

Feasibility test for Solidified Fuel with Cow Manure (고체연료화 방법을 적용한 우분 처리 가능성 평가)

  • Jeong, Kwang-Hwa;Kim, Jung-Kon;Lee, Dong-Jun
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.6
    • /
    • pp.112-119
    • /
    • 2017
  • In this study, the availability of cow manure as raw material for solid fuel production was investigated. Since the water content of the cow manure was too high, it was dewatered using a laboratory hydraulic compressure ($11.3kg/cm^2$). The moisture content of the cow manure decreased from 82.01% to 73.36 wt.%. The dewatered cow manure was homogenized by the experimental apparatus and then put into the rotating cylindrical apparatus. From the consecutive processes, the cow ball-shaped pellet which size ranged from 3.0 to 25.0 mm was produced. The major factor for making palletized fuel from cow manure was the moisture content. Based on the experimental data, the moisture content of cow manure for pelletizing cow manure was identified as 65~75 wt.%. When the moisture content of the cow manure was lower than 30 wt.%, the diameter of the pellets maded from cow manure was smaller than 3 mm. On the other hand, when the water content of the cow manure was higher than 75 wt/%, the diameter of the processed pellets tended to be larger than 25 mm. The characteristics of the processed cow manure pellets was analyzed to be in accordance with the livestock solid fuel quality standard. The pyrolysis characteristic of the pellet was analyzed by raising the heating temperature of the experimental equipment from 200 to $900^{\circ}C$. The mass change between of 20 and $130^{\circ}C$ corresponds to the amount of moisture contained in the cow manure. The amount of moisture was about 15% of the total weight of cow manure samples. The cow manure pellet was thermally stable up to $280^{\circ}C$. It can be interpreted that combustion of cow manure pellet does not occur until the surface temperature reaches $280^{\circ}C$. The mass change of pellet between of 280 and $450^{\circ}C$ was considered to be due to the vaporization of volatile organic compounds (VOCs) present in the cow manure pellet. The maximum production of VOCs was showed near $330^{\circ}C$.

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Control of Inverter Frequency (인버터 주파수 제어에 따른 CO2용 수냉식 열펌프의 성능 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4721-4726
    • /
    • 2010
  • The performance characteristics of water-chilling heat pump using CO2 for the control of inverter frequency was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter flow type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4m length. The experimental results summarize as the following: for constant inlet temperature of evaporator and gas cooler, as mass flow rate, compression ratio and discharge pressure increases with the inverter frequency. And heating capacity and compressor work increases, but coefficient of performance(COP) decreases with the inverter frequency of compressor. As inlet temperature of secondary fluid in the evaporator increases from $15^{\circ}C$ to $25^{\circ}C$, compression ratio and compressor work decreases, but mass flow rate, heating capacity and COP increases with the inverter frequency of compressor. The above tendency is similar with performance variation with respect to the variation of inverter frequency in the conventional vapor compression refrigeration cycle.

Survey of asbestos containing material in laboratory equipment at a university (대학 실험실 장비 중 석면 함유 조사)

  • Ham, Seung hon;Kim, Sung ho;Yeom, Jong soo;Chung, Jin ho;Lee, Ik mo;Yoon, Chung sik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.2
    • /
    • pp.110-115
    • /
    • 2011
  • Objectives: The aim of this study is to survey for finding asbestos containing equipment at the laboratories using picture based questionnaire and polarized light microscopic analysis. Methods: This study was conducted from 2009 to 2010 at a university in Seoul. In 2009, picture based questionnaire was distributed to 100 laboratories during the regular laboratory air quality monitoring. In 2010, we emailed all professors of the same university who have laboratories to participate voluntarily this survey. For the laboratories consented to participate survey, picture based questionnaire was distributed and collected. Suspected asbestos containing material and apparatus were collected at the laboratories which replied they have suspected material and equipment. Collected samples were analyzed with polarized light microscope at the laboratory accredited by ministry of employment and labor in Korea. Results: Total of 18 out of 100 laboratories reported that they had suspected asbestos containing equipment in 2009. Twenty-three samples were collected and three samples (13%), one heating mantle and two pairs of insulation gloves, contained asbestos. Thirty four laboratories reported they had suspected asbestos containing material or equipment in 2010. Sixty samples were collected and four of them (6%), two pairs of insulation gloves, one packing rope in dry oven and, one pair of tongs, contained asbestos. All founded asbestos was chrysotile and the content of chrysotile was more than 90% for all equipment except heating mantle which has less than 1%. Conclusions: We confirmed that asbestos was still used at the laboratories though strict regulations on asbestos use in Korea. The method of picture based questionnaire invented in this study could be applied for asbestos survey to other research institute or university where there are many laboratories because of its simplicity and accessibility without huge man power, cost and time.

Flow properties of thermoplasticized Gutta Percha obturation materials (열가소성 가타퍼차 근관충전재료의 흐름성 특성)

  • Baek, Myong-Hyun;Song, Bu-Seok;Choi, Eun-Mi
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.311-320
    • /
    • 2018
  • The purpose of this study is to evaluate the flow ability of the thermoplasticized Gutta Percha in different temperatures. Four Gutta Percha products were classified by its hardness (soft, medium, and hard) and were experimented by the Rheometer (Melt flow indexer MFI-10, DAVENPORT, England) measuring apparatus, in $(23{\pm}2)^{\circ}C$, and in a relative humidity of ($50{\pm}5$) %, following the guidelines of ISO 1133-1:2011. The heating temperature ranged from $108^{\circ}C$, $160^{\circ}C$ to $200^{\circ}C$, and the load at 2.16 kg and 3.8 kg. The Gutta Percha was cut in 5 mm to be suitable for the rheometer pressurization process. After the experiment was conducted with a preheating time of 5 minutes, a cutting time of 5-240 seconds, and a sample of 10 grams, the Gutta Percha did not show any changes in fluidity for $108^{\circ}C$, $160^{\circ}C$, but showed a change in its flow ability in $200^{\circ}C$. Also, the Gutta Percha did not show any changes in its fluidity when it was pressurized by 2.16 and 3.8 kilograms. Therefore, this experiment shows that the heating temperature and the cut-off time showed a significance while measuring the melt flow rate.

A Study on the Field Application of Superior Recycled Pavement of the Waste Asphalt (고품질 재활용 아스팔트 혼합물의 현장적용성에 대한 연구)

  • Kim, Jiwon;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.2
    • /
    • pp.67-73
    • /
    • 2012
  • Asphalt pavement waste can be recycled by crushing and heating methods with additional virgin materials and additives. In this study, a new additive using Sasol wax and Polyolefin elastomer was used for improving the quality of the Superior recycled asphalt pavement(SRP). Additive was added into the recycled mixture by 1.5% and 3% of binder content in order to have PG 70-22 and PG 76-22. Both mixtures were tested by Marshall apparatus, indirect strength testing methods, toughness testing methods, moisture susceptibility testing methods and wheel tracking testing methods. Test results met the standards of KS F 2349 and GR F 4005. Through research, it was found that these special recycled mixtures could be applied for the surface and base course of heavy traffic roads or equivalents. About 13,000 tons of the recycled mixture has been applied on Seoul Olympic road to provide new road to Hangang park for Seoul citizens.

Establishment of Analytical Method of Prochloraz in Cabbage, Apple, Mandarin, Pepper and Hulled rice with GC-ECD (GC-ECD를 이용한 배추, 사과, 감귤, 고추, 현미 중 살균제 Prochloraz의 분석법 확립)

  • Lee, Eun-Mi;Lee, Hye-Ri;Riu, Myoung-Joo;Park, Hee-Won;Na, Ye-Rim;Song, Hyuk-Hwan;Keum, Young-Soo;Zhu, Youngzhe;Kim, Jeong-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.28 no.4
    • /
    • pp.427-434
    • /
    • 2009
  • Analytical method for prochloraz in cabbage, apple, pepper, mandarin, and hulled rice was established by conversion it to 2,4,6-trichlorophenol (TCP). Crop samples were extracted with acetonitrile, and partitioned with dichloromethane. The sample extracts were hydrolyzed with pyridine hydrochloride in a vial by heating for 1 hour, and analyzed with GC-ECD after partitioning with dichloromethane. Method quantification limit (MQL) of prochloraz was 0.01 mg/kg. Recoveries at 0.1 mg/kg level was 105-113% while at 0.5 mg/kg level was 82-87%. In both of the cases CV was less than 10%. Through this procedure soxhlet extraction and refluxing apparatus of conventional method were discarded and simple solvent extraction and small vial were successfully employed, resulting in simple, rapid, economic and more precise method.