• 제목/요약/키워드: Heater Unit

검색결과 75건 처리시간 0.022초

온풍난방기의 배기열을 이용한 지중 난방용 온수공급시스템의 열회수특성 (Heat Recovery Characteristics of the Hot Water Supply System with Exhaust Heat Recovery Unit Attached to the Hot Air Heater for Plant Bed Heating in the Greenhouse)

  • 김영중;유영선;장진택;강금춘;이건중;신정웅
    • Journal of Biosystems Engineering
    • /
    • 제25권3호
    • /
    • pp.221-226
    • /
    • 2000
  • Hot air heater with light oil burner is the most common heater for greenhouse heating in the winter season in Korea. However, since the thermal efficiency of the heater is about 80∼85%, considerable unused heat amount in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The heat recovery system is made for plant bed or soil heating in the greenhouse. The system consisted of a heat exchanger made of copper pipes, ${\Phi}12.7{\times}0.7t$ located in the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tank. The total heat exchanger area is 1.5$m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to the performance test it could recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690\ell$/hr from the waste heat discharged. The exhaust gas temperature left the heat exchanger dropped to $100^{\circ}C$ from $270^{\circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{\circ}C$ from $21^{\circ}C$ at the water flow rate of $690\ell$/hr. By the feasibility test conducted in the greenhouse, the system did not encounter any difficulty in operations. And, the system could recover 220,235kJ of exhaust gas heat in a day, which is equivalent of 34% of the fuel consumption by the water boiler for plant bed heating of 0.2ha in the greenhouse.

  • PDF

주거용 건물의 난방 방식별 열적성능 및 실내환경 특성 평가를 위한 실험적 연구 (An Experimental Study on Thermal and Environmental Characteristics of Various Heating Systems in the Residential House)

  • 이충국;조성환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.121-128
    • /
    • 2005
  • This is about experimental comparison study between convective heating and radiation heating system to use the design criteria for residential house. Experiment was done in EC(environment chamber) under simultaneous outdoor condition for 4 kinds of heating system such as CRHP(Ceiling Radiant Heating Panel), BEHC( Bottom Electric Heating Coil Mat), EFCU( Electric Fan Coil Unit) and CEHU( Convective Electric Heating Unit). Result show that CRHP ,which is radiation heating system, can consume more 23% energy than convective heating system when it is operated by dry bulb temperature but can save 1 ${\sim}$ 10% when operated by glove temperature and 27% when operated by MRT.

  • PDF

소형 저궤도 위성적용을 위한 전력조절분배기 예비설계 (Preliminary Design of a Power Control and Distribution Unit for a Small LEO Satellite Application)

  • 박성우;박희성;장진백;장성수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1438-1440
    • /
    • 2005
  • A power control and distribution unit(PCDU) plays roles of protection of battery against overcharge by active control of solar array generated power, distribution of unregulated electrical power via controlled outlets to bus and instrument units, distribution of regulated electrical power to selected bus and instrument units, and provision of status monitoring and telecommand interface allowing the system and ground operate the power system, evaluate its performance and initiate appropriate countermeasures in case of abnormal conditions. In this work, we perform the preliminary design of a PCDU scheme for the small LEO Satellite applications. The main constitutes of the PCDU are the battery interface module, the auxiliary supply modules, solar array regulators with maximum power point tracking(MPPT) technology, heater power distribution modules, internal converter modules for regulated bus voltage generation. and instrument power distribution modules.

  • PDF

냉각탑용 직교류형 플라스틱 공기가열기의 열전달 및 압력손실 (Heat Transfer and Pressure Drop Characteristics of Cross-Flow Plastic Air Heater for a Cooling Tower)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6072-6081
    • /
    • 2013
  • 본 연구에서는 냉각탑 출구의 상대습도를 낮춰 백연을 저감하기 위한 목적으로 쉐브론형, 웨이브형 그리고 딤플형 공기가열기 시료에 대한 성능시험을 수행하였다. 실험은 시료의 전방풍속 1~3 m/s, 물 유량 0.19~0.33 kg/s 범위에서 수행되었다. 실험 결과 모든 시료에서 전열량은 전방풍속과 물 유량이 증가할수록 증가하였다. 공기측 압력손실도 풍속이 증가할수록 증가하였다. 동일 풍속에서 전열량은 쉐브론 형상에서 가장 크고 (평판의 1.5~1.7배) 딤플, 웨이브, 평판 순으로 나타났다. 소비동력 대비 전열량도 쉐브론 형상에서 딤플 형상보다 15% 정도 크게 나타났다. 하지만 다른 세 종류의 형상에서는 큰 차이를 보이지 않았다.

5[kW]급 풀-브릿지 고주파 공진형 인버터를 이용한 고효율 유도가열 히터 개발 (Development a High-Efficiency Induction Heating Heater using a 5[kW] Class Full-Bridge High Frequency Resonant Inverter)

  • 권혁민;신대철
    • 전력전자학회논문지
    • /
    • 제10권5호
    • /
    • pp.481-487
    • /
    • 2005
  • 제안한 유도가열 시스템은 증류탑 장치에 사용되는 특수충진체에 의한 열교환기술과 IH(Induction-Heating)전자유도가열용의 특수한 고주파 전력회로 기술을 응용한 차세대 가열방식이다. 특히 일체의 연소과정이 없다는 점에서 작업환경의 개선이 가능하며 본 기술은 IGBT대응의 고주파 인버터를 사용하여 상용교류로부터 수[kHz]의 고주파 교류를 발생시킬 수 있다. 본 논문에서는 절연체 용기 내에 특수 스텐레스 발열체부하를 수납하여 용기 외부의 고주파 공진형 인버터 접속의 워킹코일로부터 비접촉 상태로 전자유도 와전류를 구조체에 흘림으로서 발열하게 되는 새로운 유체가열방식을 제안한다. 그리고 5[kW]급 풀-브릿지 공진형 인버터 시스템과 공진부하의 동작해석, 특성분석 및 본 시스템을 이용한 고효율 스팀 발생장치의 개발과 시스템의 응용에 대해 논하였다.

석유정제산업 공정과 공정장비에 기인한 휘발성 유해 대기오염물질(HAPs)의 배출량 산정기법 (Estimation Technique of Volatile Hazardous Air Pollutants(HAPs) Emitted from Petroleum Industrial Process/Equipment)

  • 조완근;권기동;동종인;강경희
    • 한국환경과학회지
    • /
    • 제13권7호
    • /
    • pp.703-710
    • /
    • 2004
  • Petroleum refineries have been considered as an important emission source for atmospheric volatile hazardous air pollutants(HAPs). The emission source includes petroleum refinery processes and process equipment. The control strategy for volatile HAPs requires emission estimations of these pollutants. However, systematic methods of volatile HAPs emission from petroleum refineries have not yet been established. Accordingly, present study surveyed the estimation method of volatile HAPs emitted from the petroleum refinery processes and process equipment. The emission estimation methods for the petroleum refinery processes are applied for 11 petroleum refining facilities: fluidized catalytic cracking, thermal cracking, moving bed catalytic cracking, compressed engine, blowdown system, vacuum distilled column condensator, natural gas or distilled boiler, natural gas or distilled heater, oil boiler, oil heater and flare. Four emission estimation methods applied for the petroleum refinery process equipment are as follows: average emission factor approach, screening ranges approach, EPA correlation approach and unit-specific correlation approach. The process equipment for which emission factors are available are valves, pump seals, connectors, flanges and open-ended lines.

대규모 생물생산 시설의 환경 영향 연구 (A Study on the Environmental Impact of Biological Production Facilities)

  • 남상운
    • 한국농공학회지
    • /
    • 제38권5호
    • /
    • pp.106-115
    • /
    • 1996
  • This study was carried out to provide fundamental data for reuse of resources and prevention of environmental pollution Actual states of environmental pollution by biological production facilities were investigated. Various pollution loads and quantity of wastes from greenhouse and animal housings estimated. In greenhouse contents of investigation were wastes of plastic cover, noise of heater and fan, air pollutant of heater, and wastes of soilless culture system, etc. In animal housings, those were actual state of livestock waste treatment and reuse, pollutant mass unit discharge, noise pollution, and malodorant, etc. The main pollutants discharged from greenhouses were wastes of plastic cover, rockwool, and waste fluid of nutrient solution. Developments of waste disposal methods for plastic cover and rockwool are required. And recycle technique of nutrient solution for soilless culture should be developed and propagated. With the buildup of legal control, pollutant mass discharged from livestock wastes are, on the decrease. The other side, reuse of livestock excreta increased. Most animal housings are located near the dwelling house. Malodorant and noise from animal housings have bad effects on the rural living conditions. So developments of integrated complex for small scale livestock farms are required.

  • PDF

인테이크 도어 제어를 이용한 고성능 냉난방 시스템 (Air Intake Door Control for the High Air Conditioning Performance)

  • 박동규;김용철
    • 한국자동차공학회논문집
    • /
    • 제22권2호
    • /
    • pp.17-22
    • /
    • 2014
  • Recently, the quick heating performance is an important issue in the car because engine power becomes so high. So car makers have been adapted the additional heating devices as like PTC(Positive Temperature Coefficient) heater. And the quick cooling performance is also important issue because its result is used in the IQS(Initial Quality Study). In this paper, control of the HVAC(Heating, Ventilation and Air Conditioning) intake door has been studied for the quick heating and cooling performance. Heating performance is improved $4.0^{\circ}C$ at $-20^{\circ}C$ ambient temperature after 20 minutes. And cooling performance is improved $1.5^{\circ}C$ at $35^{\circ}C$ ambient temperature after 10 minutes. In addition, intake door control system brings on the cost reduction because the flab door can be eliminated. This intake door control system has been adapted to the new developing cars.

Design and Fabrication of a Dual Cylindrical Microwave and Ohmic Combination Heater for Processing of Particulate Foods

  • Lee, Seung Hyun;Choi, Won;Park, Sung Hee;Jun, Soojin
    • Journal of Biosystems Engineering
    • /
    • 제40권3호
    • /
    • pp.250-260
    • /
    • 2015
  • Purpose: Dual cylindrical microwave chambers equipped with an ohmic heating tube were designed and fabricated to maximize the electric field strength for expeditious heat treatment of particulate foods. Methods: The efficacy of the combination heater was investigated by simulating the electric field distribution by using COMSOL Multiphysics software. Results: All components of the designed microwave heating unit were suitable for transmitting maximal microwave power to the load. The simulated electric field distribution implied that single-mode microwave heating would be sufficient for the steady generation of a highly localized heating zone in the cavity. During impedance matching, the calculated reflection coefficient ($S_{11}$) was small, possibly implying minimal power loss and wave reflection in the designed microwave heating chamber. Conclusions: This study demonstrates the possibility of concentrating the microwave power at the centerline for a single-frequency microwave, for thermal treatment of multiphase foods without attenuating the microwave power.

CAN 통신을 이용한 차량 내 자동 온도조절 시스템 (In-Vehicle Auto temperature control System by CAN Network)

  • 김장주;장종욱
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 추계학술대회
    • /
    • pp.90-93
    • /
    • 2009
  • 최근 차량용 네트워크 시스템으로 사용되고 있는 CAN(Controller Area Network)은 많은 ECU들이 필요한 미래형 스마트차량에 적합한 네트워크 프로토콜로서 안정성과 신뢰성을 보장해주며, 많은 ECU들의 장착으로 Wiring Harness의 공간과 중량이 늘어남으로 인해 발생되는 에너지 소비와 비용의 증가를 대폭 줄일 수 있는 것으로 나타났다. 본 논문에서는 CAN프로토콜을 이용하여 미래형 스마트 자동차에 요구되는 편의주행, 쾌적주행을 위해 Air conditioner 와 Heater를 제어하여 차량 내부 온도를 운전자의 요구에 맞도록 자동으로 제어할 수 있는 시스템을 구현하고자 한다.

  • PDF