• Title/Summary/Keyword: Heater System

검색결과 657건 처리시간 0.037초

The influence of temperature gradient and rotation rate on Bi4Ge3O12 crystal growth by czochralski method (쵸크랄스키법에 의한 $Bi_4Ge_3O_{12}$ 단결정 육성에서 온도구배와 회전속도가 미치는 영향)

  • 배인국;황진명
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • 제9권6호
    • /
    • pp.585-589
    • /
    • 1999
  • In order to grow $Bi_4Ge_3O_{12}$ crystals by the Czochralski method equipped with the auto-diameter control system, we used the resistance heater of our own design. We measure the temperature gradients under-arious thermal configurations. The relation between the critical rotation rate corresponding to the flat interface and the temperature gadient was investigated, and the importance of the axial temperature gradient was pointed out. The results from this work were compared with those obtained by other authors when RF heating was used. The optimal conditions for the crystal growth were determined as follows; under $O_2$ atmosphere with the pulling rate fixed at 2 mm/hr, rotation rate changed from 30 to 23 rpm as the crystal growth proceeded, radial and axial temperature gradients were 50 and $40^{\circ}C$/cm near melts respectively, and the composition was chemically stoichiometric.

  • PDF

Thermal Design and Analysis for Two-Axis Gimbal-Type X-Band Antenna of Compact Advanced Satellite (차세대 중형위성용 2축 짐벌식 X-밴드 안테나의 열설계 및 궤도 열해석)

  • Chae, Bong-Geon;You, Chang-Mok;Chang, Su-Young;Kang, Eun-Su;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • 제46권4호
    • /
    • pp.306-314
    • /
    • 2018
  • A two-axis gimbal-type X-band antenna for CAS(Compact Advanced Satellite) transmits large amount of image data to ground station regardless of satellite attitude and orbital motion. This antenna mounted on the external surface of the satellite is directly exposed to the extreme space with thermal environment during the orbital operation. Therefore, a proper thermal design is needed to maintain the antenna itself as well as other main components within allowable temperature range. In this study, the thermal design effectiveness of two-axis gimbal X-band antenna was verified through the thermal analysis. In addition, required power and duty cycle of heater were estimated through the thermal analysis under conditions of system level thermal vacuum test and on-orbit thermal environment. The thermal analysis results indicated that all the main components of X-band antenna satisfy the allowable temperature requirement.

투명 면상 발열체 응용을 위한 하이브리드 스퍼터 GZO/Ag/GZO 박막의 물성평가

  • Kim, Jae-Yeon;Song, Pung-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.182.2-182.2
    • /
    • 2015
  • 최근 학계나 산업계에서 투명 전자 소자에 대하여 활발한 연구가 진행되면서, 투명 전 도성 산화물(TCO: transparent conductive oxide)에 대한 관심이 높아지고 있다. 대표적인 TCO 물질인 Indium Tin Oxide (ITO)는 가시 광 영역에서의 높은 투과 및 높은 도전성을 가져 전압을 인가하면 발열이 가능하므로 이를 투명 면상 발열체에 적용시키는 연구가 활발히 진행되고 있다. 하지만, ITO는 발열 테스트 결과 온도가 상승함에 따라 발열이 일부분에 집중되는 현상이 있으며, 전도성을 높이기 위하여 추가공정이 필요하다. 또한, 글라스의 곡면 부분에서 ITO를 사용하면 유연성이 부족하므로 크랙이 발생한다는 단점이 있다. 따라서, 최근 Silver nanowire (AgNW), Single-walled Carbon nanotube (SWCNT), ITO를 기반으로 한 AgNW에 ITO를 증착 하거나 SWCNT를 코팅하여 우수한 전기적, 광학적 특성을 지닌 하이브리드 전극이 투명 면상 발열체 재료로서 사용되고 있다. 하지만 대체된 재료들도 다양한 문제점을 가지고 있다. 예를 들어 고온에서 발열을 유지하지 못하고 끊어지거나 가시광영역의 투과율이 낮은 점 등이 있다. 이런 다양한 문제점들을 보완 할 수 있는 새로운 투명 면상 발열체에 적용한 연구가 요구되고 있다. 본 연구에서는 GZO/Ag/GZO 하이브리드 구조의 투명 면상 발열체를 제작하여 전기적, 광학적 특성을 비교하고 발열량, 온도 균일 성, 발열 유지 안정도를 확인하였다. 본 연구에서는 $50{\times}50mm$ 크기의 Non-alkali glass (삼성코닝 E2000) 기판 상에 DC마그네트론 스퍼터링 공정을 이용하여 상온에서 GZO, Ag, GZO 박막을 연속적으로 증착 하여 다층구조의 하이브리드형 투명 면상 발열체를 제조하였다. 박막 증착 파워는 DC (Ag) power 50 W, RF (GZO) power 200 W로 하였으며 GZO박막두께는 45 nm로 고정 시키고 Ag박막 두께는 5~20 nm로 변화를 주었다. 증착원은 3인치 GZO 세라믹 타깃 (2.27 wt. % Ga2O3) 과 Ag 금속 타깃 (순도 99.99%)을 사용하였으며, Ar을 40 sccm 주입 후 Working pressure는 고 순도 Ar을 사용하여 1.0 Pa로 고정하며 10분간 Pre-sputtering을하고 증착을 진행하였다. 앞선 실험을 통해 증착한 박막의 전기적, 광학적 특성은 각각 Hall-effect measurements system (ECOPIA, HMS3000), UV-Vis spectrophotometer (UV-1800, Shimadzu)를 사용해 측정 되었으며, 하이브리드 표면의 구조 및 형상은 FESEM으로 관찰하였다. 또한 표면온도 측정기infrared camera (IR camera)를 이용하여 4~12 V/cm의 전압을 인가 시 시간에 따른 투명 면상 발열체의 표면 온도변화를 관찰하였다.

  • PDF

Assessments of RELAP5/MOD3.2 and RELAP5/CANDU in a Reactor Inlet Header Break Experiment B9401 of RD-14M

  • Cho Yong Jin;Jeun Gyoo Dong
    • Nuclear Engineering and Technology
    • /
    • 제35권5호
    • /
    • pp.426-441
    • /
    • 2003
  • A reactor inlet header break experiment, B9401, performed in the RD-14M multi channel test facility was analyzed using RELAP5/MOD3.2 and RELAP5/CANDU[1]. The RELAP5 has been developed for the use in the analysis of the transient behavior of the pressurized water reactor. A recent study showed that the RELAP5 could be feasible even for the simulation of the thermal hydraulic behavior of CANDU reactors. However, some deficiencies in the prediction of fuel sheath temperature and transient behavior in athe headers were identified in the RELAP5 assessments. The RELAP5/CANDU has been developing to resolve the deficiencies in the RELAP5 and to improve the predictability of the thermal-hydraulic behaviors of the CANDU reactors. In the RELAP5/CANDU, critical heat flux model, horizontal flow regime map, heat transfer model in horizontal channel, etc. were modified or added to the RELAP5/MOD3.2. This study aims to identify the applicability of both codes, in particular, in the multi-channel simulation of the CANDU reactors. The RELAP5/MOD3.2 and the RELAP5/CANDU analyses demonstrate the code's capability to predict reasonably the major phenomena occurred during the transient. The thermal-hydraulic behaviors of both codes are almost identical, however, the RELAP5/CANDU predicts better the heater sheath temperature than the RELAP5/MOD3.2. Pressure differences between headers govern the flow characteristics through the heated sections, particularly after the ECI. In determining header pressure, there are many uncertainties arisen from the complicated effects including steady state pressure distribution. Therefore, it would be concluded that further works are required to reduce these uncertainties, and consequently predict appropriately thermal-hydraulic behaviors in the reactor coolant system during LOCA analyses.

An Experimental Study on Heat Transfer and Pressure Drop Characteristics of Carbon Dioxide During Gas Cooling Process in a Hellically Coiled Tube

  • Oh, Hoo-Kyu;Son, Chang-Hyo;Yu, Tae-Geun;Kim, Dae-Hui
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권3호
    • /
    • pp.263-271
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during 9as cooling process of $CO_2$ (R744) in a helically coiled copper tube with the inner diameter of 4.55 mm and outer diameter of 6.35 mm were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter a pre-heater and a helically coiled type gas cooler (test section). The refrigerant mass fluxes are varied from 200 to $800kg/m^2s$ and the inlet pressures of gas cooler are 7.5 to 10.0 MPa. The heat transfer coefficients of $CO_2$ in a helically coiled tube are higher than those in a horizontal tube. The Pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with those predicted by Ito's correlation developed for single-phase in a helically coiled tube. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Pitla et al. However. at the region near pseudo-critical temperature. the experiments indicate higher values than the Pitla et al correlation. Therefore, various experiments in helically coiled tubes have to be conducted and it is necessary to develop the reliable and accurate prediction determining the heat transfer and pressure drop of $CO_2$ in a helically coiled tube.

Development of a Portable ELF Electric Field Meter (휴대용 극저주파 전장측정기 개발)

  • Kil, Gyung-Suk;Song, Jae-Yong;Kim, Il-Kwon
    • Journal of Sensor Science and Technology
    • /
    • 제9권2호
    • /
    • pp.120-126
    • /
    • 2000
  • This paper dealt with the developed portable electric field meter which consisted of planar-type sensor, analog amplifier with gain controller, A/D convertor, and display unit. The principle of the planar-type sensor for detecting time-varying electric field of extremely low frequency (ELF) bandwidth was described, and a calibration system using cylindrical guard electrodes and parallel-plate electrodes was proposed. From the calibration experiment, the frequency bandwidth and the sensitivity of the developed electric field meter was $17[Hz]{\sim}7[kHz]$, and 4.45[mV/V/m], respectively. Also it can measure the electric field strength up to 10[kV/m], and the measured result was displayed on the liquid crystal display in digit. The electric field meter can be widely applied to measure electric field strength radiated from power lines, computers, and home appliances such as hair dryer, heater, etc.

  • PDF

Far Infrared Rays Drying Characteristics of Tissue Cultured Mountain Ginseng Roots (산삼배양근의 원적외선 건조특성)

  • Li, H.;Kwang, T.H.;Ning, X.F.;Cho, S.C.;Han, C.S.
    • Journal of Biosystems Engineering
    • /
    • 제34권3호
    • /
    • pp.175-182
    • /
    • 2009
  • This study was conducted to investigate the drying characteristics of tissue cultured mountain ginseng roots. The far infrared rays dryer of a double blast system used for this experiment can control the drying parameters such as far infrared heater temperature and air velocity. The far infrared rays drying tests of tissue cultured mountain ginseng roots were performed at air velocity of 0.4, 0.6, 0.8 m/s, under drying air temperature of 50, 60, and $70^{circ}C$, respectively. The results were compared with one obtained by the heated air drying method. The drying characteristics such as drying rate, color, energy consumption, saponin components and antioxidant activities were analyzed. The results showed that the drying rate of far infrared rays drying was faster than that of heated air drying and due to high temperature of drying air and fast air velocity, the far infrared rays drying of double blast type was superior to the heated air drying. The value of the color difference for heated air drying was 10.11${\sim}$12.99 and that of far infrared rays drying was in the range of 7.05${\sim}$7.54, which was in the same drying condition, also energy consumption of far infrared rays drying was in the range of 3575${\sim}$6898 kJ/kg-water. At the same time, the antioxidant activities using far infrared rays drying were higher than those using heated air drying.

A Study on Optimization of Vacuum Glazing Encapsulating Process using Frit inside a Vacuum Chamber (진공챔버 내 프리트 이용 진공유리 봉지공정 최적화에 관한 연구)

  • Park, Sang Jun;Lee, Young Lim
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제14권2호
    • /
    • pp.567-572
    • /
    • 2013
  • In houses that use heating and cooling system, most of heat loss occurs through the windows, so that low-E glass, double-layered glass, and vacuum glazing are used to minimize the heat loss. In this paper, an encapsulating process that is a final process in manufacturing the vacuum glazing has been studied, and bonding in a vacuum chamber rather than atmospheric bonding was considered. For the efficiency of the encapsulating process, frit-melting temperature and bonding time were optimized with heater temperature, and the glass preheating temperature was optimized to prevent glass breakage due to thermal stress. Thus the vacuum glass was successfully manufactured based on these results and heat transmission coefficient measured was about $5.7W/m^2K$ which indicates that the internal pressure of the vacuum glazing is $10^{-2}$ torr.

Terahertz Transmission Imaging with Antenna-Coupled Bolometer Sensor (안테나 결합형 볼로미터 방식 테라헤르츠 센서를 이용한 이차원 주사 방식의 투과형 테라헤르츠 영상 취득에 관한 연구)

  • Lee, Kyoung Il;Lim, Byung Jik;Won, Jongsuk;Hong, Sung Min;Park, Jae Hyoun;Lee, Dae Sung
    • Journal of Sensor Science and Technology
    • /
    • 제27권5호
    • /
    • pp.311-316
    • /
    • 2018
  • An antenna-coupled bolometer-type terahertz sensor was designed, fabricated, evaluated, and utilized to obtain terahertz transmission images. The sensor consists of a thin film bowtie antenna that resonates accordingly in response to an incident terahertz beam, a heater that converts the applied current in the antenna into heat, and a microbolometer that converts the rise in temperature into a change in resistance. The device is fabricated by a bulk micromachining process on a 4-inch silicon wafer. The fabricated sensor chip has a size of $2{\times}2mm$ and an active area of $0.1{\times}0.1mm^2$. The temperature coefficient of resistance (TCR) of the bolometer film (VOx) is 2.0%, which is acceptable for bolometer applications. The output sensor signal is proportional to the power of the incident terahertz beam. Transmission images were obtained with a 2-axis scanning imaging system that contained the sensor. The small active area of the sensor will enable the development of highly sensitive focal plane array sensors in terahertz imaging cameras in the future.

Numerical Investigation of the Urea Melting and Heat Transfer Characteristics with Three Different Types of Coolant Heaters (냉각수 순환 방식 가열원 형상에 따른 요소수 해동 특성에 관한 수치적 연구)

  • Lee, Seung-Yeop;Kim, Man-Young;Lee, Chun-Hwan;Park, Yun-Beom
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제20권4호
    • /
    • pp.125-132
    • /
    • 2012
  • Urea-SCR system, which converts nitrogen oxides to nitrogen and water in the presence of a reducing agent, usually AdBlue urea solution, is known as one of the powerful NOx reduction systems for mobile as well as stationary applications. For its consistent and reliable operation in mobile applications, such various problems as transient injection, ammonia slip, and freezing in cold weather have to be resolved. In this work, therefore, numerical study on three-dimensional unsteady heating problems were analyzed to understand the melting and heat transfer characteristics such as urea liquid volume fraction, temperature profiles and generated natural convection behavior in urea solution by using the commercial software Fluent 6.3. After validating by comparing numerical and experimental data with pure gallium melting phenomena, numerical experiment for urea melting is conducted with three different coolant heating models named CH1, 2, and 3, respectively. Finally, it can be found that the CH3 model, in which more coolant is concentrated on the lower part of the urea tank, has relatively better melting capability than others in terms of urea quantity of $1{\ell}$ for start-up schedule.